Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38375861

RESUMEN

Background: The Omnipod® 5 Automated Insulin Delivery System was associated with favorable glycemic outcomes for people with type 1 diabetes (T1D) in two pivotal clinical trials. Real-world evidence is needed to explore effectiveness in nonstudy conditions. Methods: A retrospective analysis of the United States Omnipod 5 System users (aged ≥2 years) with T1D and sufficient data (≥90 days of data; ≥75% of days with ≥220 continuous glucose monitor readings/day) available in Insulet Corporation's device and person-reported datasets as of July 2023 was performed. Target glucose setting usage (i.e., 110-150 mg/dL in 10 mg/dL increments) was summarized and glycemic outcomes were examined. Subgroup analyses of those using the lowest average glucose target (110 mg/dL) and stratification by baseline characteristics (e.g., age, prior therapy, health insurance coverage) were conducted. Results: In total, 69,902 users were included. Multiple and higher glucose targets were more commonly used in younger age groups. Median percentage of time in range (TIR; 70-180 mg/dL) was 68.8%, 61.3%, and 53.6% for users with average glucose targets of 110, 120, and 130-150 mg/dL, respectively, with minimal time <70 mg/dL (all median <1.13%). Among those with an average glucose target of 110 mg/dL (n = 37,640), median TIR was 65.0% in children and adolescents (2-17 years) and 69.9% in adults (≥18 years). Subgroup analyses of users transitioning from Omnipod DASH or multiple daily injections and of Medicaid/Medicare users demonstrated favorable glycemic outcomes among these groups. Conclusion: These glycemic outcomes from a large and diverse sample of nearly 70,000 children and adults demonstrate effective use of the Omnipod 5 System under real-world conditions.

2.
Diabetes Ther ; 14(3): 593-610, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36763329

RESUMEN

INTRODUCTION: Despite recent advances in diabetes technology, most people living with type 1 diabetes mellitus (T1D) are unable to meet glycemic targets. Real-world evidence can provide insight into outcomes achieved with specific treatment devices when used in clinical practice. The aim of this study was to analyze real-world outcomes collected from a large cohort of people living with T1D and initiating treatment with the Omnipod DASH System. METHODS: In this retrospective observational study, real-world outcomes were analyzed from a database of information collected from people with T1D initiating the Omnipod DASH System. Information in the database was either taken directly from the patient's medical record or self-reported if medical records were unavailable. The primary outcome was change in glycated hemoglobin (HbA1c) from baseline (before initiation) to 3 months after initiation. Secondary outcomes were changes in total daily dose of insulin (TDD) and self-reported frequency of hypoglycemic events (< 70 mg/dL). Results are separated for the adult (≥ 18 years, N = 3341) and pediatric (< 18 years, N = 1397) cohorts. RESULTS: The change in HbA1c from baseline was - 0.9 ± 1.6% ( - 10 ± 18 mmol/mol; p < 0.0001) in adults and - 0.9 ± 2.0% ( - 10 ± 22 mmol/mol; p < 0.0001) in the pediatric cohort. For those previously using multiple daily injections, HbA1c decreased by - 1.0 ± 1.7% ( - 11 ± 19 mmol/mol) in adults and - 1.0 ± 2.1% ( - 11 ± 23 mmol/mol) in the pediatric cohort (both p < 0.0001). Hypoglycemic events decreased in adults from 2.9 to 1.3 episodes per week ( - 1.6 ± 3.2 events/week; p < 0.0001), and in the pediatric cohort from 2.8 to 1.5 episodes per week ( - 1.3 ± 2.7 events/week; p < 0.0001). In adults, TDD decreased by 19.9% (p < 0.0001), and it remained stable in the pediatric cohort (p > 0.05). CONCLUSIONS: Real-world outcomes from this large cohort of people initiating therapy with the Omnipod DASH System showed significant improvement in HbA1c and a substantial reduction in hypoglycemic events after 3 months of use.

3.
Diabetes Care ; 46(4): 742-750, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36787903

RESUMEN

OBJECTIVE: Automated insulin delivery (AID) has rarely been studied in adults with type 2 diabetes. We tested the feasibility of using AID for type 2 diabetes with the Omnipod 5 System in a multicenter outpatient trial. RESEARCH DESIGN AND METHODS: Participants previously were using either basal-only or basal-bolus insulin injections, with or without the use of a continuous glucose monitor (CGM), and had a baseline HbA1c ≥8% (≥64 mmol/mol). Participants completed 2 weeks of CGM sensor data collection (blinded for those not previously using CGM) with their standard therapy (ST), then transitioned to 8 weeks of AID. Participants who previously used basal-only injections used the AID system in manual mode for 2 weeks before starting AID. Antihyperglycemic agents were continued at clinician discretion. Primary safety outcomes were percentage of time with sensor glucose ≥250 mg/dL and <54 mg/dL during AID. Additional outcomes included HbA1c and time in target range (TIR) (70-180 mg/dL). RESULTS: Participants (N = 24) had a mean (± SD) age of 61 ± 8 years, baseline HbA1c of 9.4% ± 0.9% (79 ± 10 mmol/mol), and diabetes duration of 19 ± 9 years. Percentage of time with sensor glucose ≥250 mg/dL decreased with AID by 16.9% ± 16.2% (P < 0.0001), whereas percentage of time at <54 mg/dL remained low during both ST and AID (median [interquartile range] 0.0% [0.00%, 0.06%] vs. 0.00% [0.00%, 0.03%]; P = 0.4543). HbA1c (± SD) decreased by 1.3% ± 0.7% (14 ± 8 mmol/mol; P < 0.0001) and TIR increased by 21.9% ± 15.2% (P < 0.0001) without a significant change in total daily insulin or BMI with AID. CONCLUSIONS: Findings from this feasibility trial of AID in adults with type 2 diabetes with suboptimal glycemic outcomes justify further evaluation of this technology in this population.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Adulto , Humanos , Persona de Mediana Edad , Anciano , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hemoglobina Glucada , Automonitorización de la Glucosa Sanguínea , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Glucemia , Insulina Regular Humana/uso terapéutico , Sistemas de Infusión de Insulina
4.
Diabetes Res Clin Pract ; 190: 109998, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35853530

RESUMEN

AIMS: To evaluate psychosocial outcomes for adults with type 1 diabetes (T1D) using the tubeless Omnipod® 5 Automated Insulin Delivery (AID) System. METHODS: A single-arm, multicenter (across the United States), prospective safety and efficacy study of the tubeless AID system included 115 adults with T1D. Participants aged 18-70 years completed questionnaires assessing psychosocial outcomes - diabetes distress (T1-DDS), hypoglycemic confidence (HCS), well-being (WHO-5), sleep quality (PSQI), insulin delivery satisfaction (IDSS), diabetes treatment satisfaction (DTSQ), and system usability (SUS) - before and after 3 months of AID use. Associations among participant characteristics, psychosocial measures and glycemic outcomes were evaluated using linear regression analyses. RESULTS: Adults using the tubeless AID system demonstrated improvements in diabetes-specific psychosocial measures, including diabetes distress, hypoglycemic confidence, insulin delivery satisfaction, diabetes treatment satisfaction, and system usability after 3 months (all P < 0.001). No changes in general well-being or sleep quality were observed. The psychosocial outcomes assessed were not consistently associated with baseline participant characteristics (i.e., age, sex, diabetes duration, glycemic outcomes including percent time in range 70-180 mg/dL, percent time below range < 70 mg/dL, hemoglobin A1c, or insulin regimen). CONCLUSIONS: Use of the Omnipod 5 AID system was associated with significant improvements in diabetes-related psychosocial outcomes for adults with T1D. CLINICAL TRIALS REGISTRATION NUMBER: NCT04196140.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Insulina Regular Humana/uso terapéutico , Estudios Prospectivos
5.
Diabetes Technol Ther ; 24(1): 18-25, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34491825

RESUMEN

Background: Expert opinion guidelines and limited data from clinical trials recommend adjustment to bolus insulin doses based on continuous glucose monitor (CGM) trend data, yet minimal evidence exists to support this approach. We performed a clinical evaluation of a novel CGM-informed bolus calculator (CIBC) with automatic insulin bolus dose adjustment based on CGM trend used with sensor-augmented pump therapy. Materials and Methods: In this multicenter, outpatient study, participants 6-70 years of age with type 1 diabetes (T1D) used the Omnipod® 5 System in Manual Mode, first for 7 days without a connected CGM (standard bolus calculator, SBC, phase 1) and then for 7 days with a connected CGM using the CIBC (CIBC phase 2). The integrated bolus calculator used stored pump settings plus user-estimated meal size and/or either a manually entered capillary glucose value (SBC phase) or an imported current CGM value and trend (CIBC phase) to recommend a bolus amount. The CIBC automatically increased or decreased the suggested bolus amount based on the CGM trend. Results: Twenty-five participants, (mean ± standard deviation) 27 ± 15 years of age, with T1D duration 12 ± 9 years and A1C 7.0% ± 0.9% completed the study. There were significantly fewer sensor readings <70 mg/dL 4 h postbolus with the CIBC compared to the SBC (2.1% ± 2.0% vs. 2.8 ± 2.7, P = 0.03), while percent of sensor readings >180 and 70-180 mg/dL remained the same. There was no difference in insulin use or number of boluses given between the two phases. Conclusion: The CIBC was safe when used with the Omnipod 5 System in Manual Mode, with fewer hypoglycemic readings in the postbolus period compared to the SBC. This trial was registered at ClinicalTrials.gov (NCT04320069).


Asunto(s)
Diabetes Mellitus Tipo 1 , Glucosa , Adolescente , Adulto , Glucemia , Automonitorización de la Glucosa Sanguínea , Niño , Preescolar , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/análisis , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Adulto Joven
6.
Diabetes Res Clin Pract ; 174: 108735, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33711396

RESUMEN

AIMS: To compare glycemic outcomes in adults with type 2 diabetes mellitus (T2DM) before and 90 days after initiating Omnipod® or Omnipod DASH® Insulin Management Systems. METHODS: In this retrospective observational study (N = 3,592) change in HbA1c level, total daily dose (TDD) of insulin (n = 3,053), and frequency of self-reported hypoglycemic events (HE, <70 mg/dL, n = 2,922) were assessed overall and by prior treatment modality (multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII)), age group, and baseline HbA1c category. RESULTS: Change (mean ± SD) in HbA1c was -1.3 ± 1.7% [-14 ± 19 mmol/mol] overall, -1.4 ± 1.7% [-15 ± 19 mmol/mol] for prior MDI users, and -0.9 ± 1.5% [-10 ± 16 mmol/mol] for prior CSII users (p<0.0001). The percentage of patients with HbA1c ≥9% [≥75 mmol/mol] decreased (49% to 19%), and with HbA1c <7% [<53 mmol/mol] increased (10% to 22%) (p<0.0001). Prior therapy, age, and baseline HbA1c category were factors affecting change in HbA1c (p<0.05). Reductions in TDD (overall, -33 ± 52U, p<0.0001) and HE per week (overall, -0.5 ± 2.0, p<0.0001), were seen regardless of prior treatment, age, or baseline HbA1c. CONCLUSIONS: Omnipod System use was associated with statistically and clinically meaningful reductions in HbA1c, TDD, and HE compared to prior treatments in T2DM.


Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Control Glucémico/métodos , Insulina/uso terapéutico , Adolescente , Adulto , Anciano , Femenino , Humanos , Insulina/farmacología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
7.
Clin Diabetes ; 39(1): 72-79, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33551556

RESUMEN

Continuous subcutaneous insulin infusion (CSII) treatment may improve long-term glycemic outcomes and enhance quality of life compared with a multiple daily injection (MDI) insulin regimen for people with type 1 diabetes. As the number of people treated with CSII via a tubeless insulin pump is increasing, there is growing interest in the long-term glycemic outcomes of this treatment option across diverse populations. This multicenter, retrospective study evaluated glycemic control in 156 adults with type 1 diabetes initiating tubeless insulin pump therapy following transition from either MDI or CSII with a tubed insulin pump. In this study, use of the tubeless insulin pump over 12 months was associated with significant improvement in A1C in adults with type 1 diabetes, most notably in those with an A1C ≥9.0% and those previously treated with MDI.

8.
Diabetes Technol Ther ; 23(6): 410-424, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33325779

RESUMEN

Background: The objective of this study was to assess the safety and effectiveness of the first commercial configuration of a tubeless automated insulin delivery system, Omnipod® 5, in children (6-13.9 years) and adults (14-70 years) with type 1 diabetes (T1D) in an outpatient setting. Materials and Methods: This was a single-arm, multicenter, prospective clinical study. Data were collected over a 14-day standard therapy (ST) phase followed by a 14-day hybrid closed-loop (HCL) phase, where participants (n = 36) spent 72 h at each of three prespecified glucose targets (130, 140, and 150 mg/dL, 9 days total) then 5 days with free choice of glucose targets (110-150 mg/dL) using the Omnipod 5. Remote safety monitoring alerts were enabled during the HCL phase. Primary endpoints were difference in time in range (TIR) (70-180 mg/dL) between ST and HCL phases and proportion of participants reporting serious device-related adverse events. Results: Mean TIR was significantly higher among children in the free-choice period overall (64.9% ± 12.2%, P < 0.01) and when using a 110 mg/dL target (71.2% ± 10.2%, P < 0.01), a 130 mg/dL target (61.5% ± 7.7%, P < 0.01), and a 140 mg/dL target (64.8% ± 11.6%, P < 0.01), and among adults using a 130 mg/dL target (75.1% ± 11.6%, P < 0.05), compared to the ST phase (children: 51.0% ± 13.3% and adults: 65.6% ± 15.7%). There were no serious device-related adverse events reported during the HCL phase, nor were there episodes of severe hypoglycemia or diabetic ketoacidosis. Conclusion: The Omnipod 5 System was safe and effective when used at glucose targets from 110 to 150 mg/dL for 14 days at home in children and adults with T1D.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Glucemia , Niño , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucosa , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Pacientes Ambulatorios , Estudios Prospectivos
9.
Diabetes Technol Ther ; 22(3): 174-184, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31596130

RESUMEN

Background: The objective of this study was to assess the safety and performance of the Omnipod® personalized model predictive control (MPC) algorithm in adults, adolescents, and children aged ≥6 years with type 1 diabetes (T1D) under free-living conditions using an investigational device. Materials and Methods: A 96-h hybrid closed-loop (HCL) study was conducted in a supervised hotel/rental home setting following a 7-day outpatient standard therapy (ST) phase. Eligible participants were aged 6-65 years with A1C <10.0% using insulin pump therapy or multiple daily injections. Meals during HCL were unrestricted, with boluses administered per usual routine. There was daily physical activity. The primary endpoints were percentage of time with sensor glucose <70 and ≥250 mg/dL. Results: Participants were 11 adults, 10 adolescents, and 15 children aged (mean ± standard deviation) 28.8 ± 7.9, 14.3 ± 1.3, and 9.9 ± 1.0 years, respectively. Percentage time ≥250 mg/dL during HCL was 4.5% ± 4.2%, 3.5% ± 5.0%, and 8.6% ± 8.8% per respective age group, a 1.6-, 3.4-, and 2.0-fold reduction compared to ST (P = 0.1, P = 0.02, and P = 0.03). Percentage time <70 mg/dL during HCL was 1.9% ± 1.3%, 2.5% ± 2.0%, and 2.2% ± 1.9%, a statistically significant decrease in adults when compared to ST (P = 0.005, P = 0.3, and P = 0.3). Percentage time 70-180 mg/dL increased during HCL compared to ST, reaching significance for adolescents and children: HCL 73.7% ± 7.5% vs. ST 68.0% ± 15.6% for adults (P = 0.08), HCL 79.0% ± 12.6% vs. ST 60.6% ± 13.4% for adolescents (P = 0.01), and HCL 69.2% ± 13.5% vs. ST 54.9% ± 12.9% for children (P = 0.003). Conclusions: The Omnipod personalized MPC algorithm was safe and performed well over 5 days and 4 nights of use by a cohort of participants ranging from youth aged ≥6 years to adults with T1D under supervised free-living conditions with challenges, including daily physical activity and unrestricted meals.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Sistemas de Infusión de Insulina , Adolescente , Adulto , Anciano , Algoritmos , Niño , Ejercicio Físico , Femenino , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Masculino , Comidas , Persona de Mediana Edad , Condiciones Sociales , Resultado del Tratamiento , Adulto Joven
11.
Diabetes Technol Ther ; 21(5): 265-272, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30925077

RESUMEN

Background: The objective of this study was to assess the safety and performance of the Omnipod® personalized model predictive control (MPC) algorithm with variable glucose setpoints and moderate intensity exercise using an investigational device in adults with type 1 diabetes (T1D). Materials and Methods: A supervised 54-h hybrid closed-loop (HCL) study was conducted in a hotel setting after a 7-day outpatient standard treatment phase. Adults aged 18-65 years with T1D and HbA1c between 6.0% and 10.0% were eligible. Subjects completed two moderate intensity exercise sessions of >30 min duration on consecutive days: the first with the glucose set point increased from 130 to 150 mg/dL and the second with a temporary basal rate of 50%, both started 90 min pre-exercise. Primary endpoints were percentage time in hypoglycemia <70 mg/dL and hyperglycemia ≥250 mg/dL. Results: Twelve subjects participated in the study, with (mean ± standard deviation) age 36.5 ± 14.4 years, diabetes duration 21.7 ± 15.7 years, HbA1c 7.6% ± 1.1%, and total daily dose 0.60 ± 0.22 U/kg. Outcomes for the 54-h HCL period were mean glucose: 136 ± 14 mg/dL, percentage time <70 mg/dL: 1.4% ± 1.3%, 70-180 mg/dL: 85.1% ± 9.3%, and ≥250 mg/dL: 1.8% ± 2.4%. In the 12-h period after exercise start, percentage time <70 mg/dL was 1.4% ± 2.7% with the raised glucose set point and 1.6% ± 3.0% with reduced basal rate. The percentage time <70 mg/dL overnight was 0% ± 0% on both study nights. Conclusions: The Omnipod personalized MPC algorithm performed well and was safe during day and night use in response to variable glucose set points and with temporarily raised glucose set point or reduced basal rate 90 min in advance of moderate intensity exercise in adults with T1D.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/análisis , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Sistemas de Infusión de Insulina , Insulina/uso terapéutico , Adolescente , Adulto , Anciano , Algoritmos , Diabetes Mellitus Tipo 1/sangre , Ejercicio Físico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
12.
J Diabetes Sci Technol ; 13(1): 20-26, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30239214

RESUMEN

The Omnipod DASH™ Insulin Management System (Insulet Corp, Billerica, MA) is a discreet, tubeless, wearable insulin pump that holds up to 200 units of U-100 insulin and delivers therapy through customizable basal rates and bolus amounts. This recently FDA-cleared system consists of the insulin pump ("Pod"), which is worn on body and delivers insulin, and the Personal Diabetes Manager (PDM), which is a handheld device used to wirelessly control and monitor the Pod functionality. The PDM can also be paired with the CONTOUR® NEXT ONE blood glucose (BG) meter (Ascensia Diabetes Care, Basel, Switzerland) to wirelessly receive BG readings. This review provides a detailed description of the Pod and PDM. Key features of the Pod are described, including the novel pump delivery mechanism, waterproof (IP28) housing design, and automated cannula insertion. The technology introduced in the new system, such as touchscreen PDM interface, Bluetooth® wireless technology, and wireless internet connectivity, is also presented. Last, Omnipod® Insulin Management System clinical data are reviewed, including early feasibility results for the Omnipod Horizon™ Automated Glucose Control hybrid closed-loop system.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/instrumentación , Diseño de Equipo , Hemoglobina Glucada/análisis , Humanos , Hipoglucemiantes/administración & dosificación , Internet , Cumplimiento de la Medicación , Tecnología Inalámbrica
13.
J Diabetes Sci Technol ; 12(6): 1132-1142, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30304951

RESUMEN

BACKGROUND: Medical device technology is evolving at a rapid pace, with increasing patient expectations to use modern technologies for diabetes management. With the significant expansion of the use of wireless technology and complex, securely connected digital platforms in medical devices, end user needs and behaviors have become essential areas of focus. METHODS: This article provides a detailed description of the user-centered design approach implemented in developing the Omnipod DASH™ Insulin Management System (Insulet Corp., Billerica, MA) Bluetooth®-enabled locked-down Android device handheld controller (Personal Diabetes Manager, PDM). Key methodologies used in the PDM design are described, including how the science of user experience (UX) was integrated into new agile product development. UX methods employed included heuristic evaluations of insulin pumps, iterative formative usability testing, information architecture studies, in-home ethnographic visits, participatory design activities, and interviews. RESULTS: Over 343 users participated in UX research and testing. Key design choices informed by UX research included updating the layout of critical data on the PDM home page, providing access to requested contextual information while a bolus is in progress, and creating an easy-to-understand visual of a 24-hour basal program. Task completion rates for comprehending information on the PDM home page were 87% or greater. The System Usability Scale result for the design prior to limited market release was 84.4 ± 13.4 (out of 100; n = 37). CONCLUSIONS: The UX process described in this article can serve as a blueprint for medical device manufacturers seeking to enhance product development. Adopting UX research methodologies will help ensure that new diabetes devices are safe, easy-to-use, and meet the needs of users.


Asunto(s)
Diabetes Mellitus/terapia , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Telemedicina/instrumentación , Dispositivos Electrónicos Vestibles , Adolescente , Adulto , Anciano , Niño , Preescolar , Nube Computacional , Computadoras de Mano , Diabetes Mellitus/sangre , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Redes Neurales de la Computación , Atención Dirigida al Paciente/métodos , Teléfono Inteligente/instrumentación , Interfaz Usuario-Computador , Tecnología Inalámbrica/instrumentación , Adulto Joven
14.
Diabetes Technol Ther ; 20(9): 585-595, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30070928

RESUMEN

BACKGROUND: This study assessed the safety and performance of the Omnipod® personalized model predictive control (MPC) algorithm using an investigational device in adults with type 1 diabetes in response to overestimated and missed meal boluses and extended boluses for high-fat meals. MATERIALS AND METHODS: A supervised 54-h hybrid closed-loop (HCL) study was conducted in a hotel setting after a 7-day outpatient open-loop run-in phase. Adults aged 18-65 years with type 1 diabetes and HbA1c 6.0%-10.0% were eligible. Primary endpoints were percentage time in hypoglycemia <70 mg/dL and hyperglycemia ≥250 mg/dL. Glycemic responses for 4 h to a 130% overestimated bolus and a missed meal bolus were compared with a 100% bolus for identical meals, respectively. The 12-h postprandial responses to a high-fat meal were compared using either a standard or extended bolus. RESULTS: Twelve subjects participated in the study, with (mean ± standard deviation): age 35.4 ± 14.1 years, diabetes duration 16.5 ± 9.3 years, HbA1c 7.7 ± 0.9%, and total daily dose 0.58 ± 0.19 U/kg. Outcomes for the 54-h HCL period were mean glucose 153 ± 15 mg/dL, percentage time <70 mg/dL [median (interquartile range)]: 0.0% (0.0-1.2%), 70-180 mg/dL: 76.1% ± 8.0%, and ≥250 mg/dL: 4.5% ± 3.6%. After both the 100% and 130% boluses, postprandial percentage time <70 mg/dL was 0.0% (0.0-0.0%) (P = 0.50). After the 100% and missed boluses, postprandial percentage time ≥250 mg/dL was 0.2% ± 0.6% and 10.3% ± 16.5%, respectively (P = 0.06). Postprandial percentages time ≥250 mg/dL and <70 mg/dL were similar with standard or extended boluses for a high-fat meal. CONCLUSIONS: The Omnipod personalized MPC algorithm performed well and was safe during day and night use in response to overestimated, missed, and extended meal boluses in adults with type 1 diabetes.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Adulto , Algoritmos , Glucemia , Conducta Alimentaria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Páncreas Artificial , Periodo Posprandial , Adulto Joven
15.
J Diabetes Sci Technol ; 12(3): 599-607, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29390915

RESUMEN

BACKGROUND: As evidence emerges that artificial pancreas systems improve clinical outcomes for patients with type 1 diabetes, the burden of this disease will hopefully begin to be alleviated for many patients and caregivers. However, reliance on automated insulin delivery potentially means patients will be slower to act when devices stop functioning appropriately. One such scenario involves an insulin infusion site failure, where the insulin that is recorded as delivered fails to affect the patient's glucose as expected. Alerting patients to these events in real time would potentially reduce hyperglycemia and ketosis associated with infusion site failures. METHODS: An infusion site failure detection algorithm was deployed in a randomized crossover study with artificial pancreas and sensor-augmented pump arms in an outpatient setting. Each arm lasted two weeks. Nineteen participants wore infusion sets for up to 7 days. Clinicians contacted patients to confirm infusion site failures detected by the algorithm and instructed on set replacement if failure was confirmed. RESULTS: In real time and under zone model predictive control, the infusion site failure detection algorithm achieved a sensitivity of 88.0% (n = 25) while issuing only 0.22 false positives per day, compared with a sensitivity of 73.3% (n = 15) and 0.27 false positives per day in the SAP arm (as indicated by retrospective analysis). No association between intervention strategy and duration of infusion sets was observed ( P = .58). CONCLUSIONS: As patient burden is reduced by each generation of advanced diabetes technology, fault detection algorithms will help ensure that patients are alerted when they need to manually intervene. Clinical Trial Identifier: www.clinicaltrials.gov,NCT02773875.


Asunto(s)
Algoritmos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Páncreas Artificial/efectos adversos , Adulto , Estudios Cruzados , Cetoacidosis Diabética/etiología , Cetoacidosis Diabética/prevención & control , Falla de Equipo , Femenino , Humanos , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Sistemas de Infusión de Insulina/efectos adversos , Masculino , Persona de Mediana Edad
16.
Diabetes Care ; 40(12): 1719-1726, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-29030383

RESUMEN

OBJECTIVE: Artificial pancreas (AP) systems are best positioned for optimal treatment of type 1 diabetes (T1D) and are currently being tested in outpatient clinical trials. Our consortium developed and tested a novel adaptive AP in an outpatient, single-arm, uncontrolled multicenter clinical trial lasting 12 weeks. RESEARCH DESIGN AND METHODS: Thirty adults with T1D completed a continuous glucose monitor (CGM)-augmented 1-week sensor-augmented pump (SAP) period. After the AP was started, basal insulin delivery settings used by the AP for initialization were adapted weekly, and carbohydrate ratios were adapted every 4 weeks by an algorithm running on a cloud-based server, with automatic data upload from devices. Adaptations were reviewed by expert study clinicians and patients. The primary end point was change in hemoglobin A1c (HbA1c). Outcomes are reported adhering to consensus recommendations on reporting of AP trials. RESULTS: Twenty-nine patients completed the trial. HbA1c, 7.0 ± 0.8% at the start of AP use, improved to 6.7 ± 0.6% after 12 weeks (-0.3, 95% CI -0.5 to -0.2, P < 0.001). Compared with the SAP run-in, CGM time spent in the hypoglycemic range improved during the day from 5.0 to 1.9% (-3.1, 95% CI -4.1 to -2.1, P < 0.001) and overnight from 4.1 to 1.1% (-3.1, 95% CI -4.2 to -1.9, P < 0.001). Whereas carbohydrate ratios were adapted to a larger extent initially with minimal changes thereafter, basal insulin was adapted throughout. Approximately 10% of adaptation recommendations were manually overridden. There were no protocol-related serious adverse events. CONCLUSIONS: Use of our novel adaptive AP yielded significant reductions in HbA1c and hypoglycemia.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/metabolismo , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Adulto , Glucemia , Automonitorización de la Glucosa Sanguínea , Femenino , Humanos , Hipoglucemia/tratamiento farmacológico , Sistemas de Infusión de Insulina , Masculino , Persona de Mediana Edad , Páncreas Artificial
18.
BMC Genomics ; 18(1): 639, 2017 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-28826405

RESUMEN

BACKGROUND: The metabolism of archaeal methanogens drives methane release into the environment and is critical to understanding global carbon cycling. Methanogenesis operates at a very low reducing potential compared to other forms of respiration and is therefore critical to many anaerobic environments. Harnessing or altering methanogen metabolism has the potential to mitigate global warming and even be utilized for energy applications. RESULTS: Here, we report draft genome sequences for the isolated methanogens Methanobacterium bryantii, Methanosarcina spelaei, Methanosphaera cuniculi, and Methanocorpusculum parvum. These anaerobic, methane-producing archaea represent a diverse set of isolates, capable of methylotrophic, acetoclastic, and hydrogenotrophic methanogenesis. Assembly and analysis of the genomes allowed for simple and rapid reconstruction of metabolism in the four methanogens. Comparison of the distribution of Clusters of Orthologous Groups (COG) proteins to a sample of genomes from the RefSeq database revealed a trend towards energy conservation in genome composition of all methanogens sequenced. Further analysis of the predicted membrane proteins and transporters distinguished differing energy conservation methods utilized during methanogenesis, such as chemiosmotic coupling in Msar. spelaei and electron bifurcation linked to chemiosmotic coupling in Mbac. bryantii and Msph. cuniculi. CONCLUSIONS: Methanogens occupy a unique ecological niche, acting as the terminal electron acceptors in anaerobic environments, and their genomes display a significant shift towards energy conservation. The genome-enabled reconstructed metabolisms reported here have significance to diverse anaerobic communities and have led to proposed substrate utilization not previously reported in isolation, such as formate and methanol metabolism in Mbac. bryantii and CO2 metabolism in Msph. cuniculi. The newly proposed substrates establish an important foundation with which to decipher how methanogens behave in native communities, as CO2 and formate are common electron carriers in microbial communities.


Asunto(s)
Metabolismo Energético/genética , Genómica , Metano/biosíntesis , Methanobacterium/genética , Methanobacterium/metabolismo , Anaerobiosis , Proteínas Arqueales/metabolismo
19.
Diabetes Care ; 40(8): 1096-1102, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28584075

RESUMEN

OBJECTIVE: As artificial pancreas (AP) becomes standard of care, consideration of extended use of insulin infusion sets (IIS) and continuous glucose monitors (CGMs) becomes vital. We conducted an outpatient randomized crossover study to test the safety and efficacy of a zone model predictive control (zone-MPC)-based AP system versus sensor augmented pump (SAP) therapy in which IIS and CGM failures were provoked via extended wear to 7 and 21 days, respectively. RESEARCH DESIGN AND METHODS: A smartphone-based AP system was used by 19 adults (median age 23 years [IQR 10], mean 8.0 ± 1.7% HbA1c) over 2 weeks and compared with SAP therapy for 2 weeks in a crossover, unblinded outpatient study with remote monitoring in both study arms. RESULTS: AP improved percent time 70-140 mg/dL (48.1 vs. 39.2%; P = 0.016) and time 70-180 mg/dL (71.6 vs. 65.2%; P = 0.008) and decreased median glucose (141 vs. 153 mg/dL; P = 0.036) and glycemic variability (SD 52 vs. 55 mg/dL; P = 0.044) while decreasing percent time <70 mg/dL (1.3 vs. 2.7%; P = 0.001). AP also improved overnight control, as measured by mean glucose at 0600 h (140 vs. 158 mg/dL; P = 0.02). IIS failures (1.26 ± 1.44 vs. 0.78 ± 0.78 events; P = 0.13) and sensor failures (0.84 ± 0.6 vs. 1.1 ± 0.73 events; P = 0.25) were similar between AP and SAP arms. Higher percent time in closed loop was associated with better glycemic outcomes. CONCLUSIONS: Zone-MPC significantly and safely improved glycemic control in a home-use environment despite prolonged CGM and IIS wear. This project represents the first home-use AP study attempting to provoke and detect component failure while successfully maintaining safety and effective glucose control.


Asunto(s)
Diabetes Mellitus Tipo 1/terapia , Páncreas Artificial , Adolescente , Adulto , Glucemia/metabolismo , Estudios Cruzados , Femenino , Hemoglobina Glucada/metabolismo , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Masculino , Pacientes Ambulatorios , Teléfono Inteligente , Adulto Joven
20.
Diabetes Obes Metab ; 19(12): 1698-1705, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28474383

RESUMEN

AIMS: To compare intraperitoneal (IP) to subcutaneous (SC) insulin delivery in an artificial pancreas (AP). RESEARCH DESIGN AND METHODS: Ten adults with type 1 diabetes participated in a non-randomized, non-blinded sequential AP study using the same SC glucose sensing and Zone Model Predictive Control (ZMPC) algorithm adjusted for insulin clearance. On first admission, subjects underwent closed-loop control with SC delivery of a fast-acting insulin analogue for 24 hours. Following implantation of a DiaPort IP insulin delivery system, the identical 24-hour trial was performed with IP regular insulin delivery. The clinical protocol included 3 unannounced meals with 70, 40 and 70 g carbohydrate, respectively. Primary endpoint was time spent with blood glucose (BG) in the range of 80 to 140 mg/dL (4.4-7.7 mmol/L). RESULTS: Percent of time spent within the 80 to 140 mg/dL range was significantly higher for IP delivery than for SC delivery: 39.8 ± 7.6 vs 25.6 ± 13.1 ( P = .03). Mean BG (mg/dL) and percent of time spent within the broader 70 to 180 mg/dL range were also significantly better for IP insulin: 151.0 ± 11.0 vs 190.0 ± 31.0 ( P = .004) and 65.7 ± 9.2 vs 43.9 ± 14.7 ( P = .001), respectively. Superiority of glucose control with IP insulin came from the reduced time spent in hyperglycaemia (>180 mg/dL: 32.4 ± 8.9 vs 53.5 ± 17.4, P = .014; >250 mg/dL: 5.9 ± 5.6 vs 23.0 ± 11.3, P = .0004). Higher daily doses of insulin (IU) were delivered with the IP route (43.7 ± 0.1 vs 32.3 ± 0.1, P < .001) with no increased percent time spent <70 mg/dL (IP: 2.5 ± 2.9 vs SC: 4.1 ± 5.3, P = .42). CONCLUSIONS: Glycaemic regulation with fully-automated AP delivering IP insulin was superior to that with SC insulin delivery. This pilot study provides proof-of-concept for an AP system combining a ZMPC algorithm with IP insulin delivery.


Asunto(s)
Diabetes Mellitus Tipo 1/terapia , Hiperglucemia/prevención & control , Hipoglucemia/prevención & control , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina Lispro/administración & dosificación , Páncreas Artificial , Adulto , Algoritmos , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Femenino , Francia , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/uso terapéutico , Infusiones Parenterales , Infusiones Subcutáneas , Sistemas de Infusión de Insulina/efectos adversos , Insulina Lispro/efectos adversos , Insulina Lispro/uso terapéutico , Insulina Regular Humana/administración & dosificación , Insulina Regular Humana/efectos adversos , Insulina Regular Humana/uso terapéutico , Masculino , Persona de Mediana Edad , Páncreas Artificial/efectos adversos , Proyectos Piloto , Prueba de Estudio Conceptual
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...