Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Clin Lab ; 69(6)2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37307109

RESUMEN

BACKGROUND: Pseudoclavibacter alba isolated from human urine in culture collection was introduced as a new species, but since then, no other reports on P. alba isolated from the environment or organisms have been published. We thus present the first case report of P. alba bacteremia. METHODS: An 85-year-old female patient was admitted with intermittent abdominal pain and chills that had persisted for one week. She was diagnosed cholangitis with common bile duct stones. RESULTS: Gram-positive bacteria were detected in her peripheral blood culture and identified Pseudoclavibacter species by matrix-assisted laser desorption-ionization-time of flight mass spectrometry. Pseudoclavibacter alba was identified by performing the 16S ribosomal RNA gene sequence. CONCLUSIONS: This is the first case report of P. alba bacteremia in a patient with cholangitis.


Asunto(s)
Actinobacteria , Bacteriemia , Colangitis , Humanos , Femenino , Anciano de 80 o más Años , Dolor Abdominal
2.
Artículo en Inglés | MEDLINE | ID: mdl-15358318

RESUMEN

A fully automated semi-microbore high performance liquid chromatographic (HPLC) method with column-switching using UV detection was developed for the determination of glimepiride from human plasma samples. Plasma sample (900 microl) was deproteinated and extracted with ethanol and acetonitrile. The extract (70 microl) was directly injected into a Capcell Pak MF Ph-1 pre-column where the primary separation occurred to remove proteins and retain drugs using a mixture of acetonitrile and 10mM phosphate buffer (pH 2.18) (20:80, v/v). The analytes were transferred from the pre-column to an intermediate column using a switching valve and then subsequently separated on an analytical column and monitored with UV detection at 228 nm. Glimepiride was eluted with retention time 34.9 min without interference of endogenous substance from plasma. The limit of quantification (LOQ) was 10 ng/ml for glimepiride. The calibration curves were linear over the concentration range of 10-400 ng/ml (r(2) = 0.9997). Moreover, inter- and intra-day precisions of the method were less than 15% and accuracies were higher than 99%. The developed method was successfully applied for the quantification of glimepiride in human plasma and was used to support a human pharmacokinetic study following a single oral administration of 2 mg glimepiride.


Asunto(s)
Hipoglucemiantes/sangre , Compuestos de Sulfonilurea/sangre , Adulto , Disponibilidad Biológica , Cromatografía Líquida de Alta Presión , Humanos , Hipoglucemiantes/farmacocinética , Masculino , Estándares de Referencia , Reproducibilidad de los Resultados , Espectrofotometría Ultravioleta , Compuestos de Sulfonilurea/farmacocinética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA