1.
Pharmaceutics ; 16(6)2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38931843

RESUMEN

This review discusses the current progress in the clinical use of magnetic resonance-guided focused ultrasound (MRgFUS) and other ultrasound platforms to transiently permeabilize the blood-brain barrier (BBB) for drug delivery in neurological disorders and neuro-oncology. Safety trials in humans have followed on from extensive pre-clinical studies, demonstrating a reassuring safety profile and paving the way for numerous translational clinical trials in Alzheimer's disease, Parkinson's disease, and primary and metastatic brain tumors. Future directions include improving ultrasound delivery devices, exploring alternative delivery approaches such as nanodroplets, and expanding the application to other neurological conditions.

2.
Int J Hyperthermia ; 41(1): 2365385, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38897584

RESUMEN

INTRODUCTION: Pelvic recurrences from rectal cancer present a challenging clinical scenario. Hyperthermia represents an innovative treatment option in combination with concurrent chemoradiation to enhance therapeutic effect. We provide the initial results of a prospective single center feasibility study (NCT02528175) for patients undergoing rectal cancer retreatment using concurrent chemoradiation and mild hyperthermia with MR-guided high intensity focused ultrasound (MR-HIFU). METHODS: All patients were deemed ineligible for salvage surgery and were evaluated in a multidisciplinary fashion with a surgical oncologist, radiation oncologist and medical oncologist. Radiation was delivered to a dose of 30.6 Gy in 1.8 Gy per fraction with concurrent capecitabine. MR-HIFU was delivered on days 1, 8 and 15 of concurrent chemoradiation. Our primary objective was feasibility and toxicity. RESULTS: Six patients (total 11 screened) were treated with concurrent chemoradiation and mild hyperthermia with MR-HIFU. Tumor size varied between 3.1-16.6 cm. Patients spent an average of 228 min in the MRI suite and sonication with the external transducer lasted an average of 35 min. There were no complications on the day of the MR-HIFU procedure and all acute toxicities (no grade >/=3 toxicities) resolved after completion of treatment. There were no late grade >/=3 toxicities. CONCLUSION: Mild hyperthermia with MR-HIFU, in combination with concurrent chemoradiation for appropriately selected patients, is safe for localized pelvic recurrences from rectal cancer. The potential for MR-HIFU to be applied in the recurrent setting in rectal cancer treatment requires further technical development and prospective evaluation.


Asunto(s)
Quimioradioterapia , Hipertermia Inducida , Neoplasias del Recto , Terapia Recuperativa , Humanos , Neoplasias del Recto/terapia , Neoplasias del Recto/diagnóstico por imagen , Masculino , Terapia Recuperativa/métodos , Persona de Mediana Edad , Femenino , Hipertermia Inducida/métodos , Quimioradioterapia/métodos , Anciano , Imagen por Resonancia Magnética/métodos , Recurrencia Local de Neoplasia/terapia , Recurrencia Local de Neoplasia/diagnóstico por imagen , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Estudios Prospectivos , Adulto
3.
Ultrasonics ; 138: 107223, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38553135

RESUMEN

Thrombotic occlusions of large blood vessels are increasingly treated with catheter based mechanical approaches, one of the most prominent being to employ aspiration to extract clots through a hollow catheter lumen. A central technical challenge for aspiration catheters is to achieve sufficient suction force to overcome the resistance of clot material entering into the distal tip. In this study, we examine the feasibility of inducing cavitation within hollow cylindrical transducers with a view to ultimately using them to degrade the mechanical integrity of thrombus within the tip of an aspiration catheter. Hollow cylindrical radially polarized PZT transducers with 3.3/2.5 mm outer/inner diameters were assessed. Finite element simulations and hydrophone experiments were used to investigate the pressure field distribution as a function of element length and resonant mode (thickness, length). Operating in thickness mode (∼5 MHz) was found to be associated with the highest internal pressures, estimated to exceed 23 MPa. Cavitation was demonstrated to be achievable within the transducer under degassed water (10 %) conditions using hydrophone detection and high-frequency ultrasound imaging (40 MHz). Cavitation clouds occupied a substantial portion of the transducer lumen, in a manner that was dependent on the pulsing scheme employed (10 and 100 µs pulse lengths; 1.1, 11, and 110 ms pulse intervals). Collectively the results support the feasibility of achieving cavitation within a transducer compatible with mounting in the tip of an aspiration format catheter.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Transductores , Succión , Catéteres , Agua
4.
N Engl J Med ; 390(1): 82-85, 2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38169495