Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Intervalo de año de publicación
1.
J Wrist Surg ; 8(2): 147-151, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30941256

RESUMEN

Background This article measures the life quality, clinical, and functional outcomes of a patient who had undergone reconstruction of the radioscaphocapitate ligament (RSL), using brachioradialis tendon in the treatment of ulnar translation of the carpus. Case Description We present a 36-year-old man with ulnar translation in his left, nondominant wrist, after fall accident. Reconstruction of the RSL was performed. One year later, the patient experienced good evaluation. Wrist flexion was 70 degrees, extension was 60 degrees, radial deviation was 20 degrees, and ulnar deviation was 30 degrees. Forearm pronation was 85 degrees and supination was 90 degrees and digit motion was full. Disabilities of the Arm, Shoulder and Hand score of 5, Visual Analog Scale of 0, and grip strength of 82% were obtained compared with the unaffected side. Wrist radiographic aspects showed radiocarpal joint congruency. The period of fixator treatment was 8 weeks. Good stability and joint congruency of the radiocarpal joint were obtained. Good radiographic, clinical, and functional results were obtained improving the quality of life of the patient. Literature Review The treatment of ulnar translation is difficult and complicated. There is no consensus to the overall management. As there is still a lack of long-term results, the indications for surgery, various surgical options, and the type of intervention have been a matter of controversy in the literature. Would radiocarpal joint be stable when reconstruction of the RSL using brachioradialis tendon was obtained? Is it possible to reduce an ulnar translation with this technique? Clinical Relevance We would like to suggest that the radiocarpal ligament reconstruction will improve the outcome. We believe that this technique will make the wrist more stable and functional. We agree that the best time to perform the corrections is early. The authors prefer to first reconstruct the RSL and then the radiocarpal ligament suture or radioscapholunate arthrodesis.

2.
Rev. bras. ortop ; 50(6): 666-672, Nov.-Dec. 2015. tab, graf
Artículo en Portugués | LILACS | ID: lil-769990

RESUMEN

To measure the quality of life and clinical-functional results from patients diagnosed with osteoarthrosis of the distal radioulnar joint who underwent surgical treatment using the technique of total arthroplasty of the ulna, with a total or partial Ascension(r) prosthesis of the distal ulna.METHODS:Ten patients were evaluated after 12 months of follow-up subsequent to total or partial arthroplasty of the distal ulna. All of them presented post-traumatic osteoarthrosis and/or chronic symptomatic instability of the distal radioulnar joint. The study was prospective. Seven patients had previously undergone wrist procedures (two cases with Darrach, three with Sauvé-Kapandji and two with ligament reconstruction of the fibrocartilage complex) and three presented fractures of the distal ulna that evolved with pain, instability and osteoarthrosis of the distal radioulnar joint. The following were assessed: quality of life (DASH scale); percentage degree of palm grip strength (kgf) and pronosupination range of motion in relation to the unaffected side; pain (VAS); return to work; subjective evaluation of radiography; and complications...


Mensurar a qualidade de vida e os resultados clínico-funcionais dos pacientes com diagnóstico de osteoartrose da radioulnar distal submetidos ao tratamento cirúrgico pela técnica de artroplastia total da ulna com a prótese total ou parcial Ascension(r)da ulna distal. MÉTODOS: Foram avaliados 10 pacientes com 12 meses de seguimento de artroplastia total ou parcial de ulna distal. Todos apresentavam osteoartrose pós-traumática e ou instabilidade crônica e sintomática da articulação radioulnar distal. O estudo foi prospectivo. Sete pacientes tinham procedimentos prévios no punho (2-darrach, 3-Sauvé-kapandji, 2-reconstruções ligamentares do complexo da fibrocartilagem) e três apresentaram fraturas da ulna distal que evoluíram com dor, instabilidade e osteoartrose da radioulnar distal. Foram analisados a qualidade de vida (DASH), a porcentagem do grau de força de preensão palmar (kgf) e o arco de movimento de pronossupinação em relação ao lado não afetado, a dor (VAS), o retorno ao trabalho e a avaliação subjetiva da radiografia e das complicações...


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto Joven , Persona de Mediana Edad , Prótesis Articulares , Fracturas del Radio , Fracturas del Cúbito
3.
Rev Bras Ortop ; 50(5): 509-14, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26535195

RESUMEN

OBJECTIVE: To compare the mechanical parameters between two methods for stabilization through compression: 1.5 mm axial compression plate versus conical compression screw used as an intramedullary tutor. METHODS: Polyurethane models (Sawbone(®)) that simulated transverse fractures of the proximal phalanx were used. The models were divided into three groups: lateral plate, conical screw and no implant. RESULTS: Greater force was needed to result in fatigue in the synthesis using an intramedullary plate. Thus, this model was proven to be mechanically superior to the model with the lateral plate. CONCLUSION: Stabilization using the Acutrak(®) screw for treating fractures in the model used in this trial presents mechanical results that are statistically significantly superior to those from the axial compression technique using the lateral plate (Aptus Hand(®)).


OBJETIVO: Comparar os parâmetros mecânicos entre dois métodos de estabilização por compressão: placa de compressão axial de 1,5 mm com o parafuso cônico de compressão usado como tutor intramedular. MÉTODOS: Foram usados modelos de poliuretano (Sawbone®) que simulam a fratura da falange proximal transversa, divididos em três grupos (placa lateral, parafuso cônico, sem implante). RESULTADOS: Há necessidade de uma maior força para resultar na fadiga da síntese com parafuso intramedular. Comprova-se, assim, a supremacia mecânica desse sobre o modelo com a placa lateral. CONCLUSÃO: A estabilização com o parafuso Acutrak®, no tratamento das fraturas no modelo adotado neste ensaio, apresenta resultados mecânicos superiores e estatisticamente significativos em comparação com a técnica de compressão axial com o uso da placa lateral (Aptus Hand ®).

4.
Rev. bras. ortop ; 50(5): 509-514, set.-out. 2015. tab, graf
Artículo en Portugués | LILACS | ID: lil-766244

RESUMEN

Comparar os parâmetros mecânicos entre dois métodos de estabilização por com pressão: placa de compressão axial de 1,5 mm com o parafuso cônico de compressão usado como tutor intramedular. Métodos: Foram usados modelos de poliuretano (Sawbone(r)) que simulam a fratura da falange proximal transversa, divididos em três grupos (placa lateral, parafuso cônico, sem implante). Resultados: Há necessidade de uma maior força para resultar na fadiga da síntese com para fuso intramedular. Comprova-se, assim, a supremacia mecânica desse sobre o modelo com a placa lateral. Conclusão: A estabilização com o parafuso Acutrak(r), no tratamento das fraturas no modelo adotado neste ensaio, apresenta resultados mecânicos superiores e estatisticamente sig nificativos em comparacão com a técnica de compressão axial com o uso da placa lateral (Aptus Hand (r)).


To compare the mechanical parameters between two methods for stabilization through compression: 1.5 mm axial compression plate versus conical compression screw used as an intramedullary tutor. METHODS: Polyurethane models (Sawbone(r)) that simulated transverse fractures of the proximal phalanx were used. The models were divided into three groups: lateral plate, conical screw and no implant. RESULTS: Greater force was needed to result in fatigue in the synthesis using an intramedullary plate. Thus, this model was proven to be mechanically superior to the model with the lateral plate. CONCLUSION: Stabilization using the Acutrak(r) screw for treating fractures in the model used in this trial presents mechanical results that are statistically significantly superior to those from the axial compression technique using the lateral plate (Aptus Hand(r)).


Asunto(s)
Traumatismos de los Dedos , Fijación de Fractura , Fijación Interna de Fracturas , Traumatismos de la Mano
5.
Rev Bras Ortop ; 50(6): 666-72, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-27218078

RESUMEN

OBJECTIVE: To measure the quality of life and clinical-functional results from patients diagnosed with osteoarthrosis of the distal radioulnar joint who underwent surgical treatment using the technique of total arthroplasty of the ulna, with a total or partial Ascension(®) prosthesis of the distal ulna. METHODS: Ten patients were evaluated after 12 months of follow-up subsequent to total or partial arthroplasty of the distal ulna. All of them presented post-traumatic osteoarthrosis and/or chronic symptomatic instability of the distal radioulnar joint. The study was prospective. Seven patients had previously undergone wrist procedures (two cases with Darrach, three with Sauvé-Kapandji and two with ligament reconstruction of the fibrocartilage complex) and three presented fractures of the distal ulna that evolved with pain, instability and osteoarthrosis of the distal radioulnar joint. The following were assessed: quality of life (DASH scale); percentage degree of palm grip strength (kgf) and pronosupination range of motion in relation to the unaffected side; pain (VAS); return to work; subjective evaluation of radiography; and complications. RESULTS: The patients presented a mean range of motion of 174.5° (normal side: 180°). Quality of life was analyzed by applying the DASH questionnaire and the mean value found was 5.9. The mean pain score using the VAS was 2.3. The mean degree of palm grip strength (kgf) was 50.7, which represented 90.7% of the strength on the unaffected side. The complication rate was 10%: this patient presented slight dorsal instability of the ulna and persistent pain, and did not return to work. This patient is still being followed up in the outpatient clinic and occupational therapy sector, with little improvement. He does not wish to undergo a new procedure. The mean length of follow-up was 16.8 months, with a minimum of 10 and maximum of 36 months. CONCLUSION: This concept is subject to the test of time. Implantation of a prosthesis is a very interesting addition to the surgical arsenal for those who are specialists in hand surgery. Arthroplasty of the distal ulna is a safe and effective method with clinical-functional and quality-of-life improvements for patients and presents a low complication rate.


OBJETIVO: Mensurar a qualidade de vida e os resultados clínico-funcionais dos pacientes com diagnóstico de osteoartrose da radioulnar distal submetidos ao tratamento cirúrgico pela técnica de artroplastia total da ulna com a prótese total ou parcial Ascension® da ulna distal. MÉTODOS: Foram avaliados 10 pacientes com 12 meses de seguimento de artroplastia total ou parcial de ulna distal. Todos apresentavam osteoartrose pós-traumática e ou instabilidade crônica e sintomática da articulação radioulnar distal. O estudo foi prospectivo. Sete pacientes tinham procedimentos prévios no punho (2-darrach, 3-Sauvé-kapandji, 2-reconstruções ligamentares do complexo da fibrocartilagem) e três apresentaram fraturas da ulna distal que evoluíram com dor, instabilidade e osteoartrose da radioulnar distal. Foram analisados a qualidade de vida (DASH), a porcentagem do grau de força de preensão palmar (kgf) e o arco de movimento de pronossupinação em relação ao lado não afetado, a dor (VAS), o retorno ao trabalho e a avaliação subjetiva da radiografia e das complicações. RESULTADOS: Os pacientes apresentaram, em média, o arco de movimento de 174,5° e o lado normal 180°. A qualidade de vida foi analisada pela aplicação do questionário DASH e o valor médio encontrado foi 5,9. A avaliação da dor, com o uso da escala VAS, foi de 2,3, em média. O grau de força de preensão palmar (kgf) foi de 50,7, em média, o que representa 90,7% da força do lado não acometido. A taxa de complicações foi de 10%. Esse paciente apresentou discreta instabilidade dorsal da ulna, dor persistente e não retornou ao trabalho. Esse paciente segue no ambulatório e no setor de terapia ocupacional, com pouca melhoria. Não deseja fazer novo procedimento. O tempo de seguimento, em média, foi de 16,8 meses, com mínimo de 10 e máximo de 36 meses. CONCLUSÃO: Esse conceito está a teste do tempo. A implantação de uma prótese é uma adição muito interessante ao arsenal cirúrgico para aqueles que são especializados em cirurgia da mão. A artroplastia de ulna distal é um método seguro, eficaz, com melhoria clínico-funcional e da qualidade de vida dos pacientes e apresenta baixo índice de complicações.

6.
Rev. bras. ortop ; 49(3): 218-226, May-June/2014. tab
Artículo en Inglés | LILACS | ID: lil-712780

RESUMEN

OBJECTIVES: the purpose of this study was to compare the postoperative radiological and clinical outcomes with minimally invasive percutaneous osteosynthesis using three implants: volar locking plate, intramedullary nail system and nonbridging external fixator for distal radius fractures. METHODS: forty-eight patients (A group, 16; B group 16; C group 16) underwent minimally invasive percutaneous osteosynthesis of reductible and unstable displaced (Type IIB by Rayhack Classification) distal radius fractures. In B group intramedullary nail system was used, in A group the patients were treated with volar locking plate and in C group the patients were treated by nonbridging external fixator from January 2011 to December 2012. The mean follow-up period was 12 months. Radiologic parameters, range of motion, grip strength, and disability of the arm, shoulder, and hand score were evaluated at each examination (3rd and 6th week, and 12th months). The visual analog scale of wrist pain and complications were assessed at the final follow-up. RESULTS: the groups did not differ significantly in radiological outcomes after 12 months, but the clinical results, VAS scale and dash score in group A (volar locking plate) and B (nail intramedullary) were statistically significantly better than that of C group (nonbridging external fixator). One patient underwent an osteosynthesis with nail intramedullary and another with external fixator (C group) developed persistent pain near the site of the superficial radial nerve because of the distal's screw and pins, respectively. CONCLUSION: in clinical parameters, significant differences in outcomes were found between groups A and B after six weeks versus C group...


OBJETIVOS: comparar o resultado clínico funcional dos pacientes com diagnóstico de fratura com desvio, redutível e instável da extremidade distal do rádio submetidos ao tratamento cirúrgico pela técnica de osteossíntese percutânea e minimamente invasiva com o uso de três tipos de implante: placa volar bloqueada, haste intramedular bloqueada e fixador externo. Comparar os resultados quanto à melhoria da qualidade de vida pelo questionário Dash e ao tempo de retorno ao trabalho. MÉTODOS: divididos em três grupos (A, placa - 16; B, haste - 16; C, fixador externo - 16), 48 pacientes foram submetidos ao tratamento cirúrgico da fratura da extremidade distal do rádio, redutível e instável, classificação Rayhack (Tipo IIB), pelo método minimamente invasivo, com três tipos de implante: haste intramedular bloqueada, placa volar bloqueada e fixador externo radio-radial. Estudo feito de janeiro de 2011 a dezembro de 2012. O tempo de seguimento foi de 12 meses. Parâmetros radiográficos, dor (escala VAS), medida do arco de movimento, força de preensão palmar e o questionário Dash foram avaliados na terceira e sexta semana e no sexto mês de pós-operatório. RESULTADOS: numa análise vertical dos valores apresentados, observamos uma melhoria estatística significativa em todos os parâmetros clínicos analisados no estudo, nos três grupos. Em relação à análise horizontal, ou seja, na comparação dos grupos entre si, não houve diferenças estatísticas significativas quanto aos parâmetros radiográficos após o 12° mês de seguimento. O grau de força de preensão palmar, a medida do arco de movimento, VAS e Dash apresentaram, na terceira e sexta semana de pós-operatório, valores estatísticos...


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto Joven , Persona de Mediana Edad , Placas Óseas , Fijación Interna de Fracturas , Fracturas del Radio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...