Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Med Phys ; 34(2): 680-8, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17388186

RESUMEN

The aim of this work was to study the dosimetric potential of the Monte Carlo code MCNPX applied to the protontherapy field. For series of clinical configurations a comparison between simulated and experimental data was carried out, using the proton beam line of the MEDICYC isochronous cyclotron installed in the Centre Antoine Lacassagne in Nice. The dosimetric quantities tested were depth-dose distributions, output factors, and monitor units. For each parameter, the simulation reproduced accurately the experiment, which attests the quality of the choices made both in the geometrical description and in the physics parameters for beam definition. These encouraging results enable us today to consider a simplification of quality control measurements in the future. Monitor Units calculation is planned to be carried out with preestablished Monte Carlo simulation data. The measurement, which was until now our main patient dose calibration system, will be progressively replaced by computation based on the MCNPX code. This determination of Monitor Units will be controlled by an independent semi-empirical calculation.


Asunto(s)
Algoritmos , Método de Montecarlo , Terapia de Protones , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Alta Energía/métodos , Programas Informáticos , Simulación por Computador , Modelos Biológicos , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad , Validación de Programas de Computación
2.
Med Phys ; 32(4): 910-9, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15895573

RESUMEN

Patients with ocular melanoma have been treated since June 1991 at the medical cyclotron of the Centre Antoine Lacassagne (CAL). Positions and sizes of the ocular nozzle elements were initially defined based on experimental work, taking as a pattern functional existing facilities. Nowadays Monte Carlo (MC) calculation offers a tool to refine this geometry by adjusting size and place of beam modeling devices. Moreover, the MC tool is a useful way to calculate the dose and to evaluate the impact of secondary particles in the field of radiotherapy or radiation protection. Both LINAC and cyclotron producing x rays, electrons, protons, and neutrons are available in CAL, which suggests choosing MCNPX for its particle versatility. As a first step, the existing installation was input in MCNPX to check its aptitude to reproduce experimentally measured depth-dose profile, lateral profile, output-factor (OF), and absolute dose. The geometry was defined precisely and described from the last achromatic bending magnet of our proton beam line to the position of treated eyes. Relative comparisons of percentage depth-dose and lateral profiles, performed between measured data and simulations, show an agreement of the order of 2% in dose and 0.1 mm in range accuracy. These comparisons, carried out with and without beam-modifying device, yield results compatible to the required precision in ocular melanoma treatments, as long as adequate choices are made on MCNPX input decks for physics card. Absolute dose and OF issued from calculations and measurements were also compared. Results obtained for these two kinds of data, carried out in the simplified situation of an unmodulated beam, indicate that MC calculation could effectively complement measurements. These encouraging results are a large source of motivation to promote further studies, first in a new design of the ocular nozzle, and second in the analysis of the influence of beam-modifying devices attached to the final patient collimator, such as wedge or compensators, on dose values.


Asunto(s)
Neoplasias del Ojo/radioterapia , Melanoma/radioterapia , Aceleradores de Partículas , Protones , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Alta Energía/métodos , Simulación por Computador , Ciclotrones , Humanos , Modelos Estadísticos , Método de Montecarlo , Fantasmas de Imagen , Radiometría/métodos , Radioterapia de Alta Energía/instrumentación , Programas Informáticos , Rayos X
3.
Int J Radiat Biol ; 76(10): 1297-303, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11057737

RESUMEN

PURPOSE: To determine the relative biological effectiveness (RBE) for initial and delayed inactivation of cells by a modulated proton beam suitable for the treatment of tumours of the eye, within the spread-out Bragg peak and in its distal declining edge. MATERIALS AND METHODS: Human tumour SCC25 cells were irradiated with the 65 MeV proton beam at the Cyclotron Medicyc in Nice. Perspex plates of different thickness were used to simulate five positions along the beam line: 2mm corresponding to the entrance beam; 15.6 and 25 mm in the spread-out Bragg peak; 27.2 and 27.8mm for the distal edge. At each position clonogenic survival of the irradiated cells and of their progeny were determined at various dose values. 60Co gamma-rays were used as reference radiation. RESULTS: RBE values evaluated at the survival level given by 2 Gy of gamma-rays increased with increasing depth from close to 1.0 at the proximal to about 1.2 at the distal part of the peak. Within the declining edge it reached the value of about 1.4 at 27.2 and about 2 at 27.8 mm. For the progeny of irradiated cells, the RBE value ranged from 1.0 to 1.1 within the spread-out Bragg peak and then increased up to a value of 2.0 at the last position. The dose-effect curves for the progeny always had a larger shoulder than for the irradiated progenitors, their alpha parameters being lower by a factor of about 4 and their beta parameters always being higher. The alpha/beta ratio was about 50 Gy for the progenitors and about 6 Gy for their progeny. The incidence of delayed effects increased with dose and with the depth within the beam. CONCLUSIONS: RBE values for the inactivation of cells irradiated in the spread-out Bragg peak are compatible with the value currently assumed in clinical applications. In the distal declining edge of the beam, the RBE values increased significantly to an extent that may be of concern when the region of the treatment volume is close to sensitive tissues. The yield of delayed reproductive cell death was significant at each position along the beam line.


Asunto(s)
Neoplasias/radioterapia , Terapia de Protones , Supervivencia Celular/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Humanos , Efectividad Biológica Relativa , Células Tumorales Cultivadas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...