Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Adv Orthop ; 2023: 3158206, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37635747

RESUMEN

Background: Osteoarthritis (OA) is the most common disease of the hip in adults, and its etiology is divided into two groups: primary and secondary. Although acetabular dysplasia is the most frequent reason for total hip arthroplasty (THA) in Japan, primary OA has increased recently. Although there are two types of femoral head migration in primary OA: superior and medial, there are some patients with prominent femoral head lateralization. This study aimed at evaluating the relationship between femoral head lateralization and bone morphology of the acetabulum and proximal femur using radiographic factors in primary OA of the hip. Methods: A retrospective study was conducted between 2008 and 2017 to assess 1308 hips with OA who underwent primary THAs at our institute. The diagnostic criteria for primary OA were Crowe type 1, Sharp's angle <45°, and center-edge (CE) angle >25°. We classified patients with primary OA into two groups based on femoral head lateralization: group L with lateralization or group N without. Radiographic factors included Sharp's angle, CE angle, acetabular inclination, acetabular depth ratio (ADR), acetabular head index (AHI), and femoral neck-shaft angle (FNA), all examined on an anteroposterior pelvic radiograph. Femoral neck anteversion was calculated using computerized axial tomography. Results: Primary OA was diagnosed in 210/1308 hips (16.1%) (group L: 112 hips (8.6%); group N: 98 (7.5%)). Patient demographics were not significantly different. Radiographic factors with observed significant differences between group L and group N were the average CE angle (33.0° vs. 35.1°, respectively, p = 0.009), ADR (251.6 vs. 273.4, p < 0.001), AHI (77.2 vs. 80.4, p < 0.001), and FNA (136.9° vs. 134.8°, p = 0.012). Conclusions: This investigation suggests that primary OA with femoral head lateralization demonstrated specific identifiable radiographic characteristics in the acetabulum and proximal femur that might contribute to hip joint instability such as the dysplastic hip.

3.
J Arthroplasty ; 37(11): 2214-2224, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35588903

RESUMEN

BACKGROUND: The Trilliance stem (B. Braun-Aesculap, Tuttlingen, Germany), a novel collarless triple-tapered polished stem, was introduced in 2009. The aim of this study is to evaluate the long-term clinical and radiological results of the Trilliance stem with line-to-line implantation in primary total hip arthroplasty using a direct anterior approach. METHODS: A consecutive retrospective series of 130 patients (151 hips) who underwent total hip arthroplasty between February 2009 and August 2011 were evaluated for a minimum of 10 years. Of these, 87.4% had a diagnosis of secondary osteoarthritis based on developmental hip dysplasia. Clinical and radiological results, complications were evaluated and survival analysis was performed. RESULTS: The mean follow-up was 10.7 years (range, 10.0-12.1). Thirteen hips (13 patients, 6.8%) were lost to follow-up. Adequate cementation (Barrack grade A) was achieved in 136 hips (93.8%) 1 week post-operatively. Nearly all (144 hips, 99.3%) had been inserted within the range of 3°. No significant differences were identified between high- (≥30 procedures/year) and low- (<30 procedures/year) volume surgeons. The Kaplan-Meier survival analysis with revision of the femoral component for aseptic loosening, revision of the femoral component for any reason and revision of either component for any reason as the end points, cumulative survivorship was 100.0%, 97.6% (95% confidence interval (CI) 95.4-100.0) and 96.5% (95% CI 93.8-99.3) at 10 years, respectively. CONCLUSION: The Trilliance stem with line-to-line implantation using a direct anterior approach has an excellent clinical and radiological outcome at a minimum of 10 years' follow-up. LEVEL OF EVIDENCE: Level IV, Retrospective cohort study.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Estudios de Seguimiento , Humanos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
4.
Injury ; 53(6): 2247-2258, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35292157

RESUMEN

INTRODUCTION: Cemented femoral component design including its mechanical behavior in total hip arthroplasty (THA) has influenced the occurrence of postoperative periprosthetic femoral fracture (PPFF). The main aim of this study was to investigate the influence of the calcar collar and surface finish in the cemented femoral component on the risk of PPFF. MATERIALS AND METHODS: This retrospective review was undertaken of 1082 primary THAs in 912 patients using cemented femoral components followed for a minimum of five years (mean, 9.4 years; range, 5-24 years). The incidence of PPFF, patients' demographics and surgical details were evaluated. Kaplan-Meier survivorship analysis was performed for four different outcomes: any PPFF, revision of the femoral component for PPFF, aseptic loosening, and for any reason. RESULTS: The overall incidence of PPFFs was 1.0% (n = 11): 1.4% (n = 10) in the collarless polished (CLP) group, none in the collared polished (CP) group and 0.6% (n = 1) in the collared non-polished (CNP) group (p > 0.05). Kaplan-Meier survival analysis for the femoral component at 12 years with PPFF as the end point was 97.4% (95% confidence interval [CI], 94.9 to 99.8) in the collarless group and 99.7% (95% CI, 99.1 to 100) in the collared group (p = 0.048). With revision of the femoral component for aseptic loosening as the end point, survivorship was 100.0% in the CLP and CP groups, and 98.1% (95% CI, 95.9 to 100) in the CNP group (CLP vs CP, p > 0.999; CLP vs CNP, p = 0.001; CP vs CNP, p = 0.112). CONCLUSION: This study demonstrated that the calcar collar in the cemented femoral component could play an important role to reduce the incidence of PPFF. The surface finish in the cemented femoral components influenced the incidence of femoral component revision for aseptic loosening over 5-12 years. Surgeons should consider not only the geometry and the mechanical function of the femoral components based on different design philosophies, but also potential complications associated with different designs that may require revision arthroplasty.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas del Fémur/epidemiología , Fracturas del Fémur/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Incidencia , Fracturas Periprotésicas/epidemiología , Fracturas Periprotésicas/cirugía , Diseño de Prótesis , Falla de Prótesis , Reoperación
5.
Clin J Pain ; 38(2): 77-87, 2021 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-34803154

RESUMEN

OBJECTIVES: The pain of hip osteoarthritis (OA) is generally recognized as nociceptive in origin because of the local pathology. However, some patients with OA experience a neuropathic pain component as an essential part of some nociplastic pain subtype. Here, we sought to examine the mechanism of chronic pain of symptomatic hip OA by the association of its distribution, complex pain mechanism screening, and the prevalence of lumbar spinal stenosis. MATERIALS AND METHODS: We conducted a prospective cross-sectional study of 100 hips in 100 patients with symptomatic hip OA in a chronic state. We examined all baseline clinical characteristics including clinical and functional score, location of pain and numbness, and pain score (PainDETECT questionnaire and the Leeds Assessment of Neuropathic Symptoms and Signs), and magnetic resonance imaging of the hip and lumbar spine. RESULTS: The PainDETECT questionnaire and Leeds Assessment of Neuropathic Symptoms and Signs revealed that 23% of the patients had a neuropathic pain component. There were 24 variations of the pain pattern. By contrast, the pain localized around the hip joint was only 15%. Pain distal to the thigh and any numbness was significantly more frequent in the group with neuropathic pain (P<0.001). Lumbar spinal stenosis grade was not significantly different between patients with nociceptive pain and those with neuropathic pain. Pain score was significantly correlated with the pain in clinical and functional scores. DISCUSSION: Among patients with symptomatic hip OA, the distribution of pain was various, and about 23% of patients had neuropathic, nociplastic, or mixed pain as a possibility for somatosensory system disturbances.


Asunto(s)
Dolor Crónico , Osteoartritis de la Cadera , Estenosis Espinal , Dolor Crónico/epidemiología , Estudios Transversales , Humanos , Nocicepción , Osteoartritis de la Cadera/complicaciones , Osteoartritis de la Cadera/diagnóstico por imagen , Osteoartritis de la Cadera/epidemiología , Prevalencia , Estudios Prospectivos , Estenosis Espinal/complicaciones , Estenosis Espinal/epidemiología
6.
BMC Musculoskelet Disord ; 22(1): 601, 2021 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-34193115

RESUMEN

BACKGROUND: A triple-tapered polished femoral stem was implanted with line-to-line cementing technique. The purpose of this study was to determine the survivorship, loosening rate, stem subsidence, radiologic changes and clinical outcomes in the minimum 10-year follow-up. METHODS: This was a retrospective study done in three institutes. Finally, 118 hips in 97 patients could be followed-up at the mean follow-up period of 126.3 months. The survivorship, radiological and clinical outcomes were investigated. RESULTS: Radiologically, 107 hips (90.7%) were categorized to Barrack cementing grade A, and 108 stems (91.5%) were inserted in neutral position. All hips were not loose and were not revised due to any reason. Survival with revision for any reason as the endpoint was 100% after 10 years. At the last follow-up, the mean subsidence was 0.43 mm, and the subsidence was less than 1 mm in 110 hips (93.2%). JOA hip score improved from 42.7 ± 8.9 points preoperatively to 92.8 ± 6.8 points at the last follow-up. No patient complained thigh pain. CONCLUSIONS: Line-to-line cementing technique with use of a triple-tapered polished stem was effective to achieve good cementation quality and centralization of the stem. The subsidence was small, and the minimum 10-year results were excellent without any failures related to the stem. TRIAL REGISTRATION: Retrospectively registered.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Seguimiento , Humanos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
7.
Bone Jt Open ; 2(5): 278-292, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33940938

RESUMEN

AIMS: The main aims were to identify risk factors predictive of a radiolucent line (RLL) around the acetabular component with an interface bioactive bone cement (IBBC) technique in the first year after THA, and evaluate whether these risk factors influence the development of RLLs at five and ten years after THA. METHODS: A retrospective review was undertaken of 980 primary cemented THAs in 876 patients using cemented acetabular components with the IBBC technique. The outcome variable was any RLLs that could be observed around the acetabular component at the first year after THA. Univariate analyses with univariate logistic regression and multivariate analyses with exact logistic regression were performed to identify risk factors for any RLLs based on radiological classification of hip osteoarthritis. RESULTS: RLLs were detected in 27.2% of patients one year postoperatively. In multivariate regression analysis controlling for confounders, atrophic osteoarthritis (odds ratio (OR) 2.17 (95% confidence interval (CI), 1.04 to 4.49); p = 0.038) and 26 mm (OR 3.23 (95% CI 1.85 to 5.66); p < 0.001) or 28 mm head diameter (OR 3.64 (95% CI 2.07 to 6.41); p < 0.001) had a significantly greater risk for any RLLs one year after surgery. Structural bone graft (OR 0.19 (95% CI 0.13 to 0.29) p < 0.001) and location of the hip centre within the true acetabular region (OR 0.15 (95% CI 0.09 to 0.24); p < 0.001) were significantly less prognostic. Improvement of the cement-bone interface including complete disappearance and poorly defined RLLs was identified in 15.1% of patients. Kaplan-Meier survival analysis for the acetabular component at ten years with revision of the acetabular component for aseptic loosening as the end point was 100.0% with a RLL and 99.1% without a RLL (95% CI 97.9 to 100). With revision of the acetabular component for any reason as the end point, the survival rate was 99.2% with a RLL (95% CI 97.6 to 100) and 96.5% without a RLL (95% CI 93.4 to 99.7). CONCLUSION: This study demonstrates that acetabular bone quality, head diameter, structural bone graft, and hip centre position may influence the presence of the any RLL. Cite this article: Bone Joint Open 2021;2(5):278-292.

8.
Mol Cell Endocrinol ; 527: 111240, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33676985

RESUMEN

Chronic hyperglycemia causes pancreatic ß-cell dysfunction, impaired insulin secretion and the suppression of insulin gene expression. This phenomenon is referred to as glucotoxicity, and is a critical component of the pathogenesis of type 2 diabetes. We previously reported that the expression of candidate plasticity gene 16 (CPG16) was higher in rat pancreatic INS-1 ß-cells under glucotoxic conditions and CPG16 suppressed insulin promoter activity. However, the molecular mechanisms of the CPG16-mediated suppression of insulin gene expression are unclear. In this study, we found that CPG16 directly bound and phosphorylated jun dimerization protein 2 (JDP2), an AP-1 family transcription factor. CPG16 co-localized with JDP2 in the nucleus of INS-1 cells. JDP2 bound to the G1 element of the insulin promoter and up-regulated promoter activity. Finally, CPG16 suppressed the up-regulation of insulin promoter activity by JDP2 in a kinase activity-dependent manner. These results suggest that CPG16 suppresses insulin promoter activity by phosphorylating JDP2.


Asunto(s)
Regulación de la Expresión Génica , Células Secretoras de Insulina/metabolismo , Insulina/biosíntesis , Proteínas Serina-Treonina Quinasas/metabolismo , Proteínas Represoras/metabolismo , Elementos de Respuesta , Animales , Línea Celular , Quinasas Similares a Doblecortina , Femenino , Insulina/genética , Masculino , Ratones , Ratones Endogámicos BALB C , Fosforilación , Proteínas Serina-Treonina Quinasas/genética , Ratas Wistar , Proteínas Represoras/genética
9.
Arch Orthop Trauma Surg ; 141(1): 139-147, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33123811

RESUMEN

INTRODUCTION: A well-fixed cement-bone interface is a crucial factor for acetabular and femoral components in cemented total hip arthroplasty (THA). The aim of the present study was to evaluate the middle-term clinical and radiological results of fixing the acetabular component with an interface bioactive bone cement (IBBC) technique in primary cemented THA. MATERIALS AND METHODS: We undertook a retrospective review was undertaken of 193 primary cemented THAs in 174 patients using acetabular components cemented with an IBBC technique and followed for a minimum of 5 years (mean 8.3 years; range 5-17 years). Baseline data, clinical and radiological outcomes were evaluated. RESULTS: Japanese Orthopedic Association hip score and modified Harris hip scores demonstrated significant clinical improvement in all patients (p < 0.001). Radiolucent lines were detected in 15 hips (7.8%) at the first year and 24 hips (12.4%) at the final post-operative follow-up. The Kaplan-Meier survivorship with radiographic loosening as the end point was 97.8% [95% confidence interval (CI) 95.2-100]. With revision of the acetabular component for aseptic loosening as the end point, component survival was 99.0% (95% CI 97.5-100). With revision of the acetabular component for any reason as the end point, component survival was 97.0% (95% CI 93.9-100). CONCLUSIONS: Clinical and radiological results of the acetabular component with the IBBC technique in primary cemented THA were excellent.


Asunto(s)
Acetábulo , Artroplastia de Reemplazo de Cadera , Cementos para Huesos , Prótesis de Cadera , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Radiografía , Estudios Retrospectivos
11.
J Orthop ; 21: 544-549, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33029042

RESUMEN

INTRODUCTION: Ceramic-on-ceramic (COC) total hip arthroplasty (THA) was developed to reduce wear debris, and consequently the occurrence of osteolysis and aseptic loosening. The purpose of the present study was to determine the incidence and natural history of noise including squeaking after COC THA, and to clarify whether clinical outcomes and any demographic and implant-related factors are associated with noise from these ceramic bearings. METHODS: This was a retrospective observational study of 137 primary COC THAs between 2004 and 2009 at our institute. The Mean follow-up was for 10.5 years. All patients were followed up with an office visit to obtain information regarding noise, pain, and function. The correlations between the noise, and patient demographic, radiographic, and implant-related factors were evaluated. RESULTS: Noise developed in 30 hips (21.9%), specifically squeaking in 2 (1.5%) of the 137 hips during the follow-up period. Noise including squeaking was not associated with pain or functional outcomes. There was significant correlation between noise and cup anteversion, in that cup anteversion of patients with noise was smaller than that in those without noise. No significant correlation was found between noise and any other patient demographic including age, sex, height, body weight, or body mass index. Kaplan-Meier survivorship analysis with revision for any reason and an aseptic loosening of either component as the end point, revealed a cumulative survival rate at 10 years of 98.4% and 99.1% respectively. CONCLUSION: The long-term clinical and radiographic outcome of cementless COC THA is excellent, but we should be vigilant for noise from COC bearings.

12.
Trauma Case Rep ; 28: 100326, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32642536

RESUMEN

AO/OTA type 31-A1.2 intertrochanteric femoral fractures generally are considered stable intertrochanteric fractures. We report a case of an unstable AO/OTA type 31-A1.2 intertrochanteric femoral fracture. Primary internal fixation was performed with a long cephalomedullary nail taking instability into account. Postoperative X-rays showed an acceptable reduction with a slight fracture gap in extension on the lateral trochanteric side. However, additional salvage surgery was required because the long cephalomedullary nail broke as a result of the instability caused by non-union and varus deformity of the proximal femur. More attention should be directed to strategies of primary internal fixation including choice of fixation instrumentation in terms of mechanical stability because this type of fracture can be remarkably unstable despite radiographic diagnosis of a usually stable AO/OTA classification type 31-A1.2 fracture.

13.
Gan To Kagaku Ryoho ; 47(1): 180-182, 2020 Jan.
Artículo en Japonés | MEDLINE | ID: mdl-32381898

RESUMEN

A 71-year-old male presented with abdominal distension and fever to our hospital. Abdominal CT revealed a huge tumor in abdomen, and non-curative surgery was performed. Peritoneal dissemination was widespread and the tumor invaded the bladder and sigmoid-colon mesenterium. Two months after the initial surgery, CT showed liver metastasis, and oral administration of imatinib mesylate was started. The peritoneal dissemination and liver metastasis showed a decrease, and this was well controlled for 45 months without severe side effects. Abdominal CT revealed peritoneal dissemination in the ileocecum after 43 months since the administration of imatinib. Therefore, sunitinib treatment was initiated. After 3 months of sunitinib administration, the tumor perforated. Emergency operation was performed to resect the ileocecum, and sunitinib was continued for 1 year. In GIST with liver metastasis and peritoneal dissemination, repeated surgical resection combined with chemotherapy is important to improve the patient's survival.


Asunto(s)
Antineoplásicos/uso terapéutico , Tumores del Estroma Gastrointestinal/tratamiento farmacológico , Mesilato de Imatinib/uso terapéutico , Neoplasias del Yeyuno/tratamiento farmacológico , Neoplasias Hepáticas , Anciano , Tumores del Estroma Gastrointestinal/secundario , Humanos , Yeyuno , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/secundario , Masculino
14.
Eur J Orthop Surg Traumatol ; 30(6): 1067-1074, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32314066

RESUMEN

INTRODUCTION: Little is known about the association between well-fixed polished tapered cemented stems (PTCS) implanted by the line-to-line technique and changes of stem migration, or the change of functional anteversion of the femur after total hip arthroplasty (THA). MATERIALS AND METHODS: This retrospective study included 422 two-stage bilateral primary THAs performed using PTCS implanted by the line-to-line technique. CT scans were made on both the target side (first postoperative CT) and on the contralateral side (second postoperative CT) 1 week postoperatively. The mean follow-up was 7.8 months. CT data for each scan were transferred to 3D template software (Zed hip, Lexi, Japan). The postoperative changes of anatomical stem anteversion (ASA), functional femoral anteversion (FFA), and stem subsidence were evaluated. RESULTS: A total of 20 THAs with CT scans were available on 3D template software. The ASA and the FFA had migrated - 0.68° ± 0.62° and - 5.5° ± 9.7°, respectively, over the follow-up period. A significant positive correlation was observed between the change of subsidence and ASA (r2 = 0.34, p = 0.007), between the FFA on the second postoperative CT and ASA on the first postoperative CT (r2 = 0.26, p = 0.02) and between the FFA on the second postoperative CT and FFA on the first postoperative CT (r2 = 0.52, p = 0.0003). CONCLUSION: This study indicates that the change in axial rotation of a PTCS implanted by the line-to-line technique was less than that reported by other studies and the preoperative external rotation contracture was substantially improved after THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procesamiento de Imagen Asistido por Computador/métodos , Posicionamiento del Paciente/métodos , Complicaciones Posoperatorias/prevención & control , Falla de Prótesis/etiología , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Fémur/diagnóstico por imagen , Fémur/fisiopatología , Prótesis de Cadera/efectos adversos , Humanos , Imagenología Tridimensional , Japón , Masculino , Persona de Mediana Edad , Cuidados Posoperatorios/métodos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/fisiopatología , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
15.
Sci Rep ; 8(1): 14290, 2018 09 24.
Artículo en Inglés | MEDLINE | ID: mdl-30250231

RESUMEN

Glucagon-mediated gene transcription in the liver is critical for maintaining glucose homeostasis. Promoting the induction of gluconeogenic genes and blocking that of insulin receptor substrate (Irs)2 in hepatocytes contributes to the pathogenesis of type 2 diabetes. However, the molecular mechanism by which glucagon signalling regulates hepatocyte metabolism is not fully understood. We previously showed that a fasting-inducible signalling module consisting of general control non-repressed protein 5, co-regulator cAMP response element-binding protein binding protein/p300-interacting transactivator with Glu/Asp-rich carboxy-terminal domain 2, and protein kinase A is required for glucagon-induced transcription of gluconeogenic genes. The present study aimed to identify the downstream effectors of this module in hepatocytes by examining glucagon-induced potential target genes. One of these genes was prolyl hydroxylase domain (PHD)3, which suppressed stress signalling through inhibition of the IκB kinase-nuclear factor-κB pathway in a proline hydroxylase-independent manner to maintain insulin signalling. PHD3 was also required for peroxisome proliferator-activated receptor γ coactivator 1α-induced gluconeogenesis, which was dependent on proline hydroxylase activity, suggesting that PHD3 regulates metabolism in response to glucagon as well as insulin. These findings demonstrate that glucagon-inducible PHD3 regulates glucose metabolism by suppressing stress signalling and optimising gluconeogenesis and insulin signalling in hepatocytes.


Asunto(s)
Gluconeogénesis , Glucosa/metabolismo , Hepatocitos/metabolismo , Insulina/metabolismo , Procolágeno-Prolina Dioxigenasa/metabolismo , Transducción de Señal , Estrés Fisiológico , Animales , AMP Cíclico/metabolismo , Proteínas Quinasas Dependientes de AMP Cíclico/metabolismo , Activación Enzimática , Regulación de la Expresión Génica , Glucagón/metabolismo , Humanos , Inflamación/genética , Inflamación/patología , Interleucina-6/metabolismo , Proteínas Quinasas JNK Activadas por Mitógenos/metabolismo , Masculino , Ratones Endogámicos C57BL , Modelos Biológicos , FN-kappa B/metabolismo , Coactivador 1-alfa del Receptor Activado por Proliferadores de Peroxisomas gamma/metabolismo , Procolágeno-Prolina Dioxigenasa/genética , Prolil Hidroxilasas/metabolismo , Proteínas Represoras/metabolismo , Factor de Transcripción STAT3/metabolismo , Factor de Transcripción STAT6/metabolismo , Transactivadores/metabolismo , Respuesta de Proteína Desplegada , Factores de Transcripción p300-CBP/metabolismo
16.
Orthop Traumatol Surg Res ; 104(5): 687-694, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29783039

RESUMEN

BACKGROUND: Little is known about how bone cement and American Society of Anesthesiologists (ASA) classification influence the cardiovascular system in elderly patients with femoral-neck fractures treated with cemented hemiarthroplasty. Therefore, we performed a case-control study to investigate these questions and compared the following:≥ASA III with≤ASA II patients who underwent cemented hemiarthroplasty; and cemented with cementless hemiarthroplasty in≥ASA III patients. HYPOTHESIS: ASA classification influences the cardiovascular system during cemented hemiarthroplasty and bone cement influences intraoperative blood pressure [IBP] in patients rated≥ASA III. MATERIALS AND METHODS: This multicenter, prospective study included patients with acute displaced femoral-neck fractures. Baseline data, medical history, anesthesia, FiO2, vasopressor use, femoral component, IBP, SpO2, and complications were evaluated. Of 200 patients, 100 were cemented (mean age, 77±10 years), and 100 were cementless (mean age, 78±9 years). Cemented hemiarthroplasty employed a third-generation technique (plugging, irrigating, drying and filling the canal with cement under pressurization). RESULTS: Systolic blood pressure (SBP) decreased significantly during cementing, versus pre-rasping in≤ASA II patients (from 117.9±24.5 [range, 65-199] to 106.9±20.3 [range, 59-172]; p=0.007), in≥ASA III patients (from 129.5±21.0 [range, 90-169] to 110.4±17.9 [range, 79-157]; p=0.006), and post-stem-insertion, versus pre-rasping in≤ASA II patients (from 117.9±24.5 [range, 65-199] to 103.9±20.7 [range, 53-178]; p=0.0004), and in≥ASA III patients (from 129.5±21.0 [range, 90-169] to 111.2±24.6 [range, 70-156]; p=0.009). In≥ASA III patients, SBP decreased significantly during cementing or rasping, versus pre-rasping in cemented patients (from 129.5±21.0 [range, 90-169] to 110.4±17.9 [range, 79-157]; p=0.006), in cementless patients (from 115.0±17.7 [range, 85-150] to 100.7±15.7 [range, 75-142]; p=0.004), and post-stem-insertion, versus pre-rasping in cemented patients (from 129.5±21.0 [range, 90-169] to 111.2±SD [range]; p=0.009), and in cementless patients (from 115.0±17.7 [range, 85-150] to 89.4±17.5 [range, 58-140]; p<0.0001). There were no lethal complications. CONCLUSIONS: This study indicate a similar hemodynamic change intraoperatively between≤ASA II patients and≥ASA III patients in the cemented group, and between patients with cemented and cementless hemiarthroplasty in the≥ASA III patients. With modern hemiarthroplasty techniques, bone cement might be as safe as cementless techniques in elderly,≥ASA III patients. LEVEL OF EVIDENCE: III, multicenter case-control cohort study.


Asunto(s)
Presión Sanguínea , Cementos para Huesos , Fracturas del Cuello Femoral/cirugía , Estado de Salud , Hemiartroplastia/métodos , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Humanos , Periodo Intraoperatorio , Masculino , Estudios Prospectivos , Sístole , Estados Unidos
17.
Asian Spine J ; 12(2): 325-334, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29713415

RESUMEN

STUDY DESIGN: Retrospective observational study. PURPOSE: We examined change in lumbrosacral spine alignment and low back pain (LBP) following total hip arthroplasty (THA) in patients with severe hip osteoarthritis (OA). OVERVIEW OF LITERATURE: Severe hip osteoarthritis has been reported to cause spine alignment abnormalities and low back pain, and it has been reported that low back pain is improved following THA. METHODS: Our target population included 30 patients (29 female, mean age 63.5 years) with hip OA who underwent direct anterior approach THA. There were 12 cases with bilateral hip disease and 18 cases with unilateral osteoarthritis. Visual analogue scale (VAS) scores for LBP and coxalgia, the Roland-Morris Disability Questionnaire (RDQ), and the Japanese Orthopaedic Association Back Pain Evaluation Questionnaire (JOABPEQ) were assessed before and after surgery. Spinal alignment metrics were measured before and after surgery. RESULTS: VAS for LBP change from preoperative to final postoperative observation was significantly improved (p <0.05), as was VAS for hip pain (p<0.001). RDQ improved significantly (p<0.01). All five domains of JOABPEQ were significantly improved (p<0.05). In terms of coronal alignment, lumbar scoliosis change from preoperative to last observation was significantly reduced (p<0.05). There were no significant changes in the sagittal alignment metrics. In addition, there was a correlation between before and after RDQ difference and before and after lumbar scoliosis difference (p<0.05). VAS for LBP (p<0.05) as well as RDQ (p<0.05) were significantly improved only in unilateral OA. Lumbar scoliosis was significantly improved in cases of unilateral OA (p<0.05), but alignment did not improve in cases of bilateral OA (p=0.29). CONCLUSIONS: The present study demonstrates improvements in VAS for LBP, RDQ, and all domains of JOABPEQ. There were also significant reductions in lumbar scoliosis and an observed correlation of RDQ improvement with lumbar scoliosis improvement. We were able to observe improvements in lumbar scoliosis and low back pain only in cases of unilateral OA. It has been suggested that the mechanism of low back pain improvement following THA is related to compensatory lumbar scoliosis improvement.

18.
Gan To Kagaku Ryoho ; 45(13): 2417-2419, 2018 Dec.
Artículo en Japonés | MEDLINE | ID: mdl-30692483

RESUMEN

We report a case of unresectable pancreas cancer. A 70-year-old woman presented with worsening diabetes and serum CA19-9 elevation. A tumor with portal vein and supra-mesenteric vein invasion was observed by computed tomography. She was diagnosed with unresectable pancreas head cancer that was locally advanced. Chemotherapy was administered with gemcitabine and nab-paclitaxel for 19 courses, followed by gemcitabine alone for 4 courses. After the addition of 6 courses of chemotherapy, a 60%dose of chemotherapy was administered for 13 courses due to severe neutropenia. The patient died 32 months after the first visit. The 60% dose of gemcitabine and nab-paclitaxel also inhibited tumor growth. These findings suggest the effective and safe long-term use of gemcitabine and nab-paclitaxel.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica , Neoplasias Pancreáticas , Anciano , Albúminas , Antígeno CA-19-9/sangre , Desoxicitidina/administración & dosificación , Desoxicitidina/análogos & derivados , Femenino , Humanos , Paclitaxel/administración & dosificación , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/tratamiento farmacológico , Tomografía Computarizada por Rayos X , Gemcitabina
19.
Int Orthop ; 41(12): 2487-2493, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28567577

RESUMEN

PURPOSE: The purpose of this study was to clarify the difference in implant alignment between the direct anterior approach (DAA) and the anterolateral approach in the supine position (ALS). METHODS: A retrospective comparative study consisted of 215 consecutive primary total hip arthroplasties using tapered polished and straight cemented-stems via two different minimally invasive approaches (DAA group in 106 hips and ALS group in 109 hips). RESULTS: The cup radiographic anteversion angle was significantly lower in the ALS group than in the DAA group (12.9° versus 16.9°, p = 0.001). The frequency of the safe zone tended to be more favourable in the ALS group than in the DAA group (95% versus 87%, p = 0.052). Stem alignment in the sagittal plane was significantly better in the ALS group than in the DAA group (84% versus 71%, p = 0.022). CONCLUSIONS: Both cup and stem alignments were better in the ALS group than the DAA group.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Ajuste de Prótesis , Estudios Retrospectivos , Posición Supina
20.
Arch Orthop Trauma Surg ; 137(4): 523-529, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28213848

RESUMEN

INTRODUCTION: The purpose of this study was to compare the cemented bipolar hemiarthroplasty with uncemented about the change of intraoperative blood pressure and the incidence of major complications in elderly patients with femoral neck fracture. MATERIALS AND METHODS: This multiple center prospective cohort study included only patients with acute displaced femoral neck fracture (Garden stage III or IV). All patients were treated with cemented or uncemented bipolar hemiarthroplasty using modified Hardinge or Watson-Jones approach in the lateral decubitus position. Baseline data, medical history, type of anesthesia, FiO2 value, the number of vasopressor using during operation, femoral component, intraoperative blood pressure, SaO2, and major complications were evaluated. RESULTS: Of 164 patients (45 males and 119 females), 86 underwent cemented and 78 underwent uncemented bipolar hemiarthroplasty. Baseline medical histories were similar in both groups. In both the cemented and uncemented groups, intraoperative systolic blood pressure significantly decreased during cementing or rasping (106.3 and 103.6 mmHg) and after femoral component insertion (103.3 and 99.1 mmHg) compared to before rasping (120.7 and 116.4 mmHg) (p < 0.0001, respectively). Donaldson's grade seemed more favorable in uncemented group than in cemented group during cementing or rasping, during stem insertion; however, no patients experienced the lethal complication in both groups. CONCLUSIONS: Intraoperative blood pressure did not change during cemented and uncemented bipolar hemiarthrplasty for displaced femoral neck fracture. If the standard modern cement technique was performed during operation, bone cement is a safe and acceptable for elderly patients who have a lot of medical histories.


Asunto(s)
Presión Sanguínea , Cementos para Huesos/uso terapéutico , Fracturas del Cuello Femoral/cirugía , Hemiartroplastia/métodos , Hipotensión/epidemiología , Complicaciones Intraoperatorias/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Hipotensión/fisiopatología , Incidencia , Complicaciones Intraoperatorias/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...