Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
J Biomech ; 160: 111824, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37862924

RESUMEN

Model-image registration methods are commonly used in research to measure three-dimensional joint kinematics from single-plane and bi-plane x-ray images. These methods have the potential to be beneficial if used clinically, but current techniques are too slow or expensive to be clinically practical. One technical element of these methods for measuring natural bone motion is the use of digitally reconstructed radiographs (DRRs). DRRs can be very expensive to compute, or require expensive and fast computer hardware. In this technical development, a numerically efficient Siddon-Jacobs algorithm for computing DRRs was implemented on a consumer-grade graphics card using a programming language for parallel architectures. Compared to traditional voxel projection algorithms with a central-processing-unit-only implementation, the parallel computation implementation on the graphics card provided speedups of 650-1546 times faster rendering, while retaining equivalent performance for joint kinematics measurements. The use of consumer grade graphics hardware may contribute to making model-image registration measurements of joint kinematics practical for clinical use.

2.
Front Bioeng Biotechnol ; 10: 1023721, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36466333

RESUMEN

Objectives: The study aimed to elucidate target cup orientation and stem anteversions to avoid impingement between the liner and stem neck even at hip rotation with adduction during the deeply flexed posture. Methods: A computer simulation analysis was performed on 32 total hip arthroplasty patients applying patient-specific orientation of the components and in vivo hip kinematics obtained from three-dimensional analysis of the squatting motion. The anterior/posterior liner-to-neck distance and impingement were evaluated based on a virtual change in internal/external rotation (0°-60°) and adduction/abduction (0°-20°) at actual maximum flexion/extension during squatting. Cutoff values of cup orientations, stem anteversion, and combined anteversion to avoid liner-to-neck impingements were determined. Results: The anterior liner-to-neck distance decreased as internal rotation or adduction increased, and the posterior liner-to-neck distance decreased as external rotation or adduction increased. Negative correlations were found between anterior/posterior liner-to-neck distances at maximum flexion/extension and internal/external rotation. Anterior/posterior liner-to-neck impingements were observed in 6/18 hips (18/56%) at 45° internal/external rotation with 20° adduction. The range of target cup anteversion, stem anteversion, and combined anteversion to avoid both anterior and posterior liner-to-neck impingements during squatting were 15°-18°, 19°-34°, and 41°-56°, respectively. Conclusion: Simulated hip rotations caused prosthetic impingement during squatting. Surgeons could gain valuable insights into target cup orientations and stem anteversion based on postoperative simulations during the deeply flexed posture.

3.
J Arthroplasty ; 37(4): 734-741, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34968648

RESUMEN

BACKGROUND: Squatting is an important function for many daily activities, but has not been well documented after total hip arthroplasty (THA). This study investigated the participation rate of squatting and in vivo kinematics during squatting. METHODS: A survey questionnaire about squatting was mailed to patients who underwent primary THA and 328 patients returned acceptable responses. Additionally, 32 hips were evaluated for dynamic 3-dimensional kinematics of squatting using density-based image-matching techniques. Multivariate analyses were applied to determine which factors were associated with anterior liner-to-neck distance at maximum hip flexion. RESULTS: Patients who could easily squat significantly increased this ability postoperatively (23.5% vs 46%, P < .01). In 29.5% of the patients there was still no ability to squat after THA; the main reason was anxiety of dislocation (34.2%). Kinematic analysis revealed that maximum hip flexion averaged 80.7° ± 12.3° with 12.8° ± 10.7° of posterior pelvic tilt and 9.7 ± 3.0 mm of anterior liner-to-neck distance. Neither liner-to-neck, bone-to-bone, nor bone-to-implant contact was observed in any of the hips. Larger hip flexion and smaller cup anteversion were negatively associated with the anterior liner-to-neck distance at maximum hip flexion (P < .05). CONCLUSION: Postoperatively, approximately 70% of patients squatted easily or with support. Anxiety of dislocation made patients avoid squatting after THA. In vivo squatting kinematics suggest no danger of impingement or subsequent dislocation, but excessively large hip flexion and small cup anteversion remain as risks.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Luxaciones Articulares , Artroplastia de Reemplazo de Cadera/métodos , Fenómenos Biomecánicos , Articulación de la Cadera/cirugía , Humanos , Luxaciones Articulares/cirugía , Medición de Resultados Informados por el Paciente , Rango del Movimiento Articular
4.
Clin Biomech (Bristol, Avon) ; 91: 105537, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34847472

RESUMEN

Background After total hip arthroplasty, dislocation can occur when a patient unexpectedly assumes internal/external limb positions, even during chair-rising, which is a frequently activity of daily life. Therefore, determining the target cup position to avoid impingement in unexpected limb positions using in vivo data of daily life activities is critical. Methods A computer simulation was performed on 21 total hip arthroplasty patients using patient-specific component placements and hip kinematics obtained during chair-rising analysis using image-matching techniques. The liner-to-neck distance and impingement were evaluated by simulating the change in internal/external rotation angle at maximum hip flexion/extension from 0 to 90°. The cutoff values of cup anteversion and combined anteversion at 60° of internal/external rotation were determined. Findings The anterior/posterior liner-to-neck distances were negatively correlated with internal/external rotation angles (r = -0.82 and -0.78, respectively) and decreased by 1.7 and 1.8 mm for every 15° increase, respectively. Three cases (14%) of anterior/posterior impingement were observed at 60° of internal/external rotation angle, respectively. The cutoff values for cup anteversion and combined anteversion to avoid impingement at 60° of internal/external rotation angle were 12°-25°/38°-62°, respectively. The stem anteversion, adjustable by cup anteversion to meet both the target cup anteversion and combined anteversion, was 13°-50°. Interpretation Simulated unintentional internal or external hip rotation, even during chair-rising, caused impingement and posed a dislocation risk. If the stem anteversion is excessively small or large in meeting the target combined anteversion, adjustments to stem anteversion could be recommended in addition to adjustments in cup anteversion.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Luxaciones Articulares , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Fenómenos Biomecánicos , Simulación por Computador , Articulación de la Cadera/cirugía , Humanos , Luxaciones Articulares/cirugía , Rango del Movimiento Articular
5.
J Orthop Sci ; 27(3): 665-671, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-33933328

RESUMEN

BACKGROUND: Mid-flexion instability is the one of the reasons for patient dissatisfaction after total knee arthroplasty (TKA). The purposes of this study were to evaluate in vivo knee kinematics and clinical outcomes using a novel TKA design with a gradual femoral radius component and s-curve post-cam, which are intended to prevent the instability initiated by sudden reductions in the femoral radius observed with conventional components. METHODS: We used radiographic-based, image-matching techniques to analyze femorotibial anteroposterior translation, axial rotation, and anterior/posterior cam-post contact during two dynamic movements, squatting and stair climbing, in 20 knees that had undergone posterior-stabilized fixed-bearing TKA with an improved sagittal profiles of the femoral component and post-cam mechanism. We also evaluated patient-reported outcomes assessed by the 2011 Knee Society Score (KSS 2011). RESULTS: Squatting and stair climbing produced a similar trend in anteroposterior translation and a relatively small standard deviation at mid-flexion. Although the rotation angles varied widely during squatting and stair climbing, the femoral component was consistently externally rotated. Anterior/posterior cam-post contact during squatting and stair climbing were observed in 0/17 knees and 0/0 knees, respectively. The "Symptoms", "Satisfaction", and "Functional activities" subscales of the KSS 2011 were significantly (P < 0.05) improved postoperatively compared to preoperatively ("Symptoms", 10 to 21; "Satisfaction", 15 to 26; "Functional activities", 25 to 71). CONCLUSION: A gradual femoral radius component with an s-curve post-cam provided stable kinematics and favorable clinical results during squatting and stair climbing at 1 year after surgery.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Artroplastia de Reemplazo de Rodilla/métodos , Fenómenos Biomecánicos , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Radio (Anatomía)/cirugía , Rango del Movimiento Articular
6.
J Orthop Sci ; 27(4): 810-814, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34045137

RESUMEN

BACKGROUND: The in vivo kinematic benefit of an asymmetrical polyethylene insert is still unknown in comparison with that of a symmetrical insert with the same femoral component design. The purpose of this study was to analyze the kinematic differences between symmetrical and asymmetrical polyethylene inserts and to detect the kinematic benefit in the asymmetrical polyethylene insert. The hypotheses are that greater axial rotation and more posterior rollback are observed in the asymmetrical polyethylene insert. METHODS: The patients were randomly allocated to the following two groups: total knee arthroplasty with a symmetrical insert and with an asymmetrical insert. In vivo knee kinematics was analyzed in asymmetrical (17 knees) and symmetrical (16 knees) inserts using an image matching technique. The symmetrical polyethylene insert had the same geometry on both sides, whereas the asymmetrical polyethylene insert had a flat surface on the postero-lateral side. The anterior/posterior position and axial rotation were compared between the two polyethylene inserts. RESULTS: The femoral component was significantly positioned posteriorly at 70° (p = 0.016) and 80° (p = 0.040) of knee flexion and externally rotated at 80° of knee flexion (p = 0.040) in the asymmetrical polyethylene insert as compared to the position of the symmetrical polyethylene insert. Femoral rollback and axial rotation from full extension to maximum flexion were greater in the asymmetrical polyethylene insert, although the difference was not significant. CONCLUSIONS: In the asymmetrical polyethylene insert, slight kinematic benefit with greater axial rotation and more posterior rollback was observed in comparison with the symmetrical polyethylene insert. Further research should be required whether the kinematic benefit of an asymmetrical polyethylene insert will lead to better patient satisfaction and function.


Asunto(s)
Prótesis de la Rodilla , Polietileno , Fenómenos Biomecánicos , Humanos , Articulación de la Rodilla/cirugía , Diseño de Prótesis , Rango del Movimiento Articular
7.
BMC Musculoskelet Disord ; 22(1): 772, 2021 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-34511113

RESUMEN

BACKGROUND: No studies have directly evaluated kinematic changes during squatting before and after bicruciate-stabilized total knee arthroplasty (BCS-TKA) with the dual cam-post mechanism and asymmetric surfaces. This study investigated the effect of BCS-TKA on changes to pre- and postoperative skeletal knee kinematics, to identify factors associated with postoperative skeletal kinematic parameters. METHODS: Seventeen knees in 17 patients were prospectively recruited before primary TKA for advanced medial knee osteoarthritis. Subjects underwent BCS-TKA and were evaluated more than 1 year postoperatively. In vivo dynamic skeletal knee kinematics were evaluated using periodic radiographic images collected during squatting to quantify the tibiofemoral functional extension/flexion angle, anteroposterior (AP) translation, and axial rotation angle using image-matching techniques. Rotational alignments of femoral and tibial components were measured postoperatively using computed tomography images. RESULTS: The pre- and postoperative tibiofemoral functional extension/flexion angles during squatting were 12.2° ± 6.7°/100.1° ± 16.8° and 9.6° ± 8.6°/109.4° ± 16.8°, respectively, with a significant difference in flexion angle (p < .05). Total AP translation was significantly larger postoperatively than preoperatively (10.8 mm ± 3.7 mm vs. 14.4 mm ± 4.2 mm, respectively; p < .05). The pre- and postoperative total rotation angles were 6.6° ± 3.0° and 6.4° ± 3.7°, respectively, indicating no significant difference. The pre- and postoperative tibiofemoral functional flexion angles were significantly associated with each other (p = .0434, r = .49). The postoperative total rotation angle was significantly smaller when the total component rotational mismatch angle between the femoral and tibial components was above 5° vs. below 5° (4.6° ± 2.7° vs. 8.3° ± 3.9°, respectively; p < .05). CONCLUSIONS: BCS-TKA significantly increased the tibiofemoral functional flexion angles, with larger AP translation postoperatively. Both preoperative skeletal kinematics and surgical techniques affected the skeletal kinematics of the replaced knee. A total component rotational mismatch angle greater than 5° significantly decreased postoperative total knee rotation during squatting.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Fenómenos Biomecánicos , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Rango del Movimiento Articular , Rotación , Tibia/diagnóstico por imagen , Tibia/cirugía
8.
J Orthop Surg (Hong Kong) ; 28(3): 2309499020981779, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33355033

RESUMEN

INTRODUCTION: Assessment of scapular kinematics and the dynamics of the scapulohumeral rhythm (SHR) would be important for understanding pathologies of the shoulder and to inform treatment. Our aim in this study was to evaluate the SHR and scapular kinematics in patients with a rotator cuff tear (RCT), compared to a control group with healthy shoulders using image-matching techniques. MATERIALS AND METHODS: The shoulder kinematics of large or massive RCT patients were evaluated and compared to a control group with healthy shoulders. Radiographic surveillance was performed throughout the full range of external rotation and scapular plane abduction. Computed tomography imaging of the shoulder complex was performed, with three-dimensional image reconstruction and matching to the radiographs to measure three-dimensional positions and orientations. SHR and angular values of the scapula were measured. RESULTS: Scapular external rotation in the late phase of external rotation movement was greater in the RCT group than in the control group (p < 0.05), but with no difference in the SHR. During scapular plane abduction, there were significant differences in SHR, scapular posterior tilt and scapular upward rotation between the RCT and control group (p < 0.05). CONCLUSIONS: Regarding clinical relevance, this study clarified the differences of SHR and angular values of the scapula between the RCT and control group. These results underline the importance of assessment the SHR and scapular kinematics in individuals with a RCT. RCT is associated with specific compensation in the kinematics of the scapula and SHR during external rotation and scapular plane abduction, which could inform treatment.


Asunto(s)
Imagenología Tridimensional/métodos , Rango del Movimiento Articular/fisiología , Lesiones del Manguito de los Rotadores/cirugía , Escápula/diagnóstico por imagen , Articulación del Hombro/cirugía , Tomografía Computarizada por Rayos X/métodos , Adulto , Femenino , Humanos , Masculino , Lesiones del Manguito de los Rotadores/diagnóstico , Lesiones del Manguito de los Rotadores/fisiopatología , Escápula/cirugía , Hombro , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiopatología
9.
J Orthop ; 21: 370-374, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32904327

RESUMEN

INTRODUCTION: The tension of anterior cruciate ligament (ACL) graft has an important role in antero-posterior (AP) and rotational stability of the knee. The purposes of this study were to analyze the kinematics and kinetics of normal knee models with loose and tight ACL tension, and to evaluate the effect of the tension of ACL on knee kinematics and kinetics. MATERIALS AND METHODS: Slack and tight ACL models were constructed in a musculoskeletal computer simulation. The effect of ACL tension on kinematics, and femorotibial contact force during various activities was analyzed. RESULTS: During stair descent activity in the slack ACL models, the lateral femoral condyles were positioned posterior, and more external rotation of the femur was observed in comparison with the normal model. The contact forces at the lateral compartment in the tight models increased during all activities, and the tension of the medial collateral ligament (MCL) in the slack models increased during the stair descent activity, compared with the normal knee model. CONCLUSION: AP and rotational instability and excessive MCL tension were observed in the ACL slack knees especially during stair descent movement, whereas the tibiofemoral contact force of the lateral compartment increased in the tight ACL knees.

10.
J Orthop ; 21: 213-217, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32273659

RESUMEN

PURPOSE: The purpose of this study was to determine the in vivo kinematics of healthy knees and those with osteoarthritis (OA), during twisting using density-based image-matching techniques. METHODS: Five healthy subjects and 26 patients with medial knee OA performed twisting under periodic X-ray imaging. RESULTS: The tibiofemoral rotation at the ipsilateral/contralateral twist in healthy and OA knees were 11° ± 9.3° externally/9.5° ± 5.6° internally (p < 0.05) and 4.4° ± 7.2° externally/2.7° ± 8° internally (p < 0.05), respectively. CONCLUSIONS: The kinematic analysis of OA knees during twisting revealed significantly smaller tibiofemoral rotation than those of healthy knees.

11.
J Orthop Sci ; 25(2): 247-254, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31000375

RESUMEN

BACKGROUND: We prospectively analyzed the hip kinematics in patients with developmental dysplasia of the hip (DDH) before and after periacetabular osteotomy (PAO) and in healthy subjects while squatting to determine the influence of coverage of the femoral head on hip kinematics. METHODS: 14 hips in 14 patients with DDH and 10 hips in 10 volunteers were included. Continuous radiographs while squatting and computed tomography images were obtained to assess the in vivo kinematics of the hip and the rim-neck distance using density-based 3D-to-2D model-to-image registration techniques. RESULTS: The maximum hip flexion angles were 100.4° and 94.9° before and after PAO (p = 0.0863), respectively. The maximum hip flexion angles after PAO did not significantly differ from those of normal hips (102.2°; p = 0.2552). The hip abduction angles at maximum hip flexion were 31.7° and 26.2° before and after PAO (p = 0.1256), respectively. The rim-neck distance decreased from averaged 12.2 mm-8.9 mm (p = 0.0044) after PAO. The lateral center edge angle (LCEA) and anterior center edge angle (ACEA) significantly improved 14.7°-42.4° and 50.4°-54.0° after PAO (p < 0.0001, p = 0.0347), respectively; in particular, the ACEA after PAO did not significantly differ from that in the normal hips (p = 0.1917). The ACEA was not correlated with hip flexion, or the rim-neck distance (p = 0.9601, 0.8764). The LCEA was also not correlated with hip abduction (p = 0.1683). CONCLUSION: Patients after PAO showed no significant difference in maximum hip flexion while squatting compared to before PAO and normal hips. Horizontalized weight-bearing acetabulum with normalized ACEA could be adequate correction of the acetabular fragment to restore hip RoM without coxalgia that induce the inability to perform squats after PAO.


Asunto(s)
Luxación Congénita de la Cadera/fisiopatología , Luxación Congénita de la Cadera/cirugía , Osteotomía , Adolescente , Adulto , Fenómenos Biomecánicos , Femenino , Luxación Congénita de la Cadera/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Rango del Movimiento Articular , Tomografía Computarizada por Rayos X , Adulto Joven
12.
J Orthop Sci ; 25(3): 452-459, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31178276

RESUMEN

BACKGROUND: There is an interest in quantifying dynamic hip kinematics before and after total hip arthroplasty (THA) during chair-rising: one of daily life activities. METHODS: The study consisted of 21 patients who underwent unilateral total hip arthroplasty for symptomatic osteoarthritis. We obtained continuous radiographs using a flat-panel X-ray detector while the participants rose from chair. We assessed the pre and postoperative hip joint's movements using three-dimensional-to-two-dimensional model-to-image registration techniques. We also measured minimum liner-to-neck distances at maximum hip flexion and extension as anterior and posterior liner-to-neck distances, respectively. Multivariate analyses were applied to determine which factors were associated with liner-to-neck distances. RESULTS: The cup inclination, cup anteversion, and stem anteversion averaged 37.4°, 23.1°, and 30.1°, respectively. Significantly larger maximum hip flexion angle (72°) was found during chair-rising after THA compared to that before THA (63°, P < 0.01). The anterior pelvic tilt at the maximum hip flexion after THA (3° of anterior tilt) was significantly (P < 0.05) anterior compared to that before THA (1° of posterior tilt). The anterior and posterior liner-to-neck distances averaged 12.3 mm and 8.1 mm, respectively, with a significant difference (P < 0.01). No liner-to-neck contact was found in any hips. In multivariate analysis, the hip flexion angle, cup inclination, stem anteversion and head diameter were significantly associated with the anterior liner-to-neck distance (P < 0.05), the hip extension angle, cup anteversion, neck length and with or without elevated rim were significantly associated with the posterior liner-to-neck distance (P < 0.05, 0.01, 0.05, 0.01, respectively). CONCLUSION: This study indicates that well-positioned THA provide increased range of hip flexion with sufficient anterior liner-to-neck clearance during chair-rising. Dynamic hip kinematics, component position, and hardware variables significantly influenced on the liner-to-neck clearance under weight-bearing conditions.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Movimiento , Soporte de Peso , Actividades Cotidianas , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Diseño Asistido por Computadora , Evaluación de la Discapacidad , Femenino , Humanos , Imagenología Tridimensional , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Rango del Movimiento Articular
13.
Clin Biomech (Bristol, Avon) ; 68: 175-181, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31229697

RESUMEN

BACKGROUND: Dynamic hip kinematics during stationary cycling after total hip arthroplasty (THA) have been unclear. Furthermore, no computer simulation of optimal cup position based on in vivo kinematics has yet been assessed. METHODS: This study consisted of 7 patients who underwent unilateral primary THA for symptomatic osteoarthritis. Using a flat-panel X-ray detector, continuous radiographs were obtained during stationary cycling. We analyzed the three-dimensional replaced hip kinematics from the top to the bottom position of the crank using image-matching techniques and quantified minimum liner-to-stem neck distance. Simulation analyses with in vivo kinematics were performed to examine patient-specific optimal cup placement against prosthetic impingement. FINDINGS: During stationary cycling, pelvis showed 27.1° of posterior tilt on average without significant change. Hip flexed by 59.4° and 19.3° on average at the top and bottom positions, respectively. Minimum liner-to-neck distance was 8.8 mm on average at the bottom position. Liner-to-neck, bone-to-bone, or bone-to-component impingement was not observed at any positions in any hips. Simulation analysis of cup placement showed that larger cup anteversion, inclination, and use of elevated liner significantly decreased the minimum distance between posterior liner and stem neck. Cup anteversion of more than 30° with elevated liner could cause posterior liner-to-neck impingement at bottom position. INTERPRETATION: Stationary cycling after THA provides no excessive hip range of motion or liner-to-neck contact. Cup placement and use of elevated liner significantly influence the minimum liner-to-neck distance, in some cases simulating posterior prosthetic impingement.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Articulación de la Cadera/cirugía , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Rango del Movimiento Articular , Rotación , Anciano , Fenómenos Biomecánicos , Simulación por Computador , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Diseño de Prótesis
14.
J Med Case Rep ; 13(1): 11, 2019 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-30635037

RESUMEN

BACKGROUND: The in vivo assessment of the three-dimensional kinematics of the hip during dance activities in patients after total hip arthroplasty has not been previously reported. We evaluated the replaced hip kinematics during recreational classical ballet and hula dance using radiographic-based image-matching techniques. CASE PRESENTATION: A 58-year-old Japanese woman (patient 1; height, 157 cm; weight, 74.5 kg) and a 73-year-old Japanese woman (patient 2; height, 153 cm; weight, 48 kg) were still doing classical ballet and hula dance, respectively, after primary total hip arthroplasty. For ballet, there were gradual three-dimensional hip movements with 48° flexion, 36° abduction, and 49° external rotation in développé and 34° flexion, 29° abduction, and 43° external rotation in plié. For hula, there were small three-dimensional hip movements with 31° flexion, 15° adduction, and 11° external rotation in kao and 17° flexion, 11° adduction, and 11° external rotation in kaholo. No liner-to-neck contact was found in any dance activities. CONCLUSION: Both classical ballet and hula dance produced complex ranges of hip movements and activity-dependent kinematics. These kinematic data could be useful for recommending each patient with total hip arthroplasty to continue recreational dance activities.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Baile/fisiología , Articulación de la Cadera/fisiología , Rango del Movimiento Articular/fisiología , Anciano , Fenómenos Biomecánicos/fisiología , Femenino , Articulación de la Cadera/diagnóstico por imagen , Humanos , Imagenología Tridimensional/métodos , Persona de Mediana Edad , Radiografía/métodos
15.
Clin Biomech (Bristol, Avon) ; 60: 95-99, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30340151

RESUMEN

BACKGROUND: There are no previous studies on the acromiohumeral distance in shoulders with large-to-massive full-thickness rotator cuff tears. In this study, the acromiohumeral distance in rotator cuff tear and healthy shoulders was measured using 3D-to-2D model-to-image registration techniques. METHODS: The dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 rotator cuff tear patients and 10 healthy control subjects. Periodic radiographic images of scapular plane abduction and axial rotation were taken using a flat-panel radiograph image detector. Movements of the shoulder joint were assessed using radiographic images and computed tomography-derived digitally reconstructed radiographs. The acromiohumeral distance was defined as the shortest 3D distance between the acromion and the proximal humerus. FINDINGS: For scapular plane abduction, the rotator cuff tear group had significantly smaller acromiohumeral distance than the control group at 15°, 30°, 45°, 60°, 75°, 135°, and 150° of humeral abduction (P < 0.05 at each measured angle). For axial rotation in the adducted position, the rotator cuff tear group had significantly smaller acromiohumeral distance than the control group at each point between -20° and 40° of glenohumeral external rotation (P < 0.05 at each measured angle). INTERPRETATION: The minimum measured acromiohumeral distance was 0.9 mm in the rotator cuff tear shoulders and 2.1 mm in the healthy shoulders at 90° of scapular plane abduction. The findings are of clinical relevance because quantitative evaluation of the dynamic acromiohumeral distances in rotator cuff tear and healthy shoulders might provide important insight into subacromial impingement.


Asunto(s)
Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/fisiopatología , Manguito de los Rotadores/fisiopatología , Síndrome de Abducción Dolorosa del Hombro/diagnóstico por imagen , Síndrome de Abducción Dolorosa del Hombro/fisiopatología , Acromion , Adulto , Anciano , Fenómenos Biomecánicos , Femenino , Voluntarios Sanos , Humanos , Húmero/diagnóstico por imagen , Húmero/fisiopatología , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Movimiento , Radiografía , Rotación , Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/cirugía , Escápula/diagnóstico por imagen , Escápula/fisiopatología , Hombro , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiopatología , Tomografía Computarizada por Rayos X
16.
J Orthop Surg Res ; 13(1): 162, 2018 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-29970119

RESUMEN

BACKGROUND: The difference in in vivo kinematics before and after total hip arthroplasty (THA) for the same subjects and the clearance between the liner and neck during squatting have been unclear. The purpose of the present study was to clarify (1) the changes in the in vivo kinematics between prosthetic hips and osteoarthritis hips of the same subjects and (2) the extent of the liner-to-neck clearance during squatting under weight-bearing conditions. METHODS: This study consisted of 10 patients who underwent unilateral THA for symptomatic osteoarthritis. Using a flat-panel X-ray detector, we obtained continuous radiographs during squatting. We analyzed the hip joint's movements using three-dimensional-to-two-dimensional model-to-image registration techniques. We also quantified the minimum distance at maximum flexion and extension, and the minimum angle at maximum flexion between the liner and stem neck. RESULTS: The maximum hip flexion angles post-THA (80.7° [range, 69.4-98.6°]) changed significantly compared with the pre-THA values (71.7° [range, 55.2°-91.2°]). The pelvic tilt angle (posterior +, anterior-) at the maximum hip flexion post-THA (10.4° [range, - 6.7° to 26.9°]) was significantly smaller than that at pre-THA (16.6° [range, - 3° to 40.3°]). The minimum anterior and posterior liner-to-neck distances averaged 10.9 and 8.0 mm, respectively, which was a significant difference. The minimum liner-to-neck angle at maximum flexion averaged 34.7° (range, 20.7°-46.3°). No liner-to-neck contact occurred in any of the hips. CONCLUSION: THA increased the range of hip joint motion and the pelvis tilted anteriorly more after than before THA, with sufficient liner-to-neck clearance during squatting. These data may be beneficial for advising patients after THA regarding postoperative activity restrictions in daily life.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Articulación de la Cadera/fisiopatología , Articulación de la Cadera/cirugía , Osteoartritis de la Cadera/fisiopatología , Osteoartritis de la Cadera/cirugía , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Postura , Rango del Movimiento Articular
17.
J Orthop ; 15(2): 650-654, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29881213

RESUMEN

This study aimed to evaluate clinical outcomes and in vivo kinematics of bi-cruciate stabilized (BCS) total knee arthroplasty (TKA), using image-matching techniques. We analyzed tibiofemoral anteroposterior translation, axial rotation, and anterior/posterior cam-post contact for 22 BCS TKAs during squatting and stair-climbing. The functional activities on the 2011 Knee Society Score were significantly improved from 36 to 71. The tibiofemoral translation and axial rotation during squatting/stair-climbing were 16.1 mm/7.1 mm and 2.5° external/1.1° internal, respectively. Anterior/posterior cam-post contacts were observed during squatting (14%/96%) and stair-climbing (27%/96%). In conclusion, BCS TKA produced physiological sagittal plane kinematics during activities with favorable clinical outcomes.

18.
Int Orthop ; 42(11): 2573-2581, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29623458

RESUMEN

PURPOSE: This study aimed to evaluate the effects of two types of total knee arthroplasty (TKA) designs: posterior-stabilized (PS) and bicruciate-stabilized (BCS) on in vivo kinematics during gait. METHODS: Continuous X-ray images of the gait were taken using a flat panel detector for 23 PS and BCS TKAs. We analyzed the tibiofemoral implant flexion angle, anteroposterior (AP) translation, axial rotation, and anterior/posterior cam-post contact using image-matching techniques. RESULTS: Double knee actions were demonstrated for the PS and BCS design (35 and 61%, respectively, p = 0.08). The tibiofemoral AP positions were significantly more posterior at peak extension (- 1.7 ± 2.2 and 1.0 ± 2.5 mm, respectively, p < 0.01) and anterior at peak flexion (1.3 ± 2.3 and - 0.8 ± 2.8 mm, respectively, p = 0.01) for the PS design than for the BCS design, with a significant difference in AP translation (3.0 ± 3.9 mm anterior and 1.7 ± 2.8 mm posterior, respectively, p < 0.01). Anterior/posterior tibial post contacts were found in 83/4% and 74/30% for the PS and BCS designs, respectively, with a significant difference in posterior contact (p = 0.72/0.04, respectively). CONCLUSION: The knee flexion pattern, tibiofemoral AP translation, axial rotation, and cam-post contact during gait varied, depending on the type of implant, the PS and BCS designs.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Análisis de la Marcha/métodos , Prótesis de la Rodilla/efectos adversos , Diseño de Prótesis/métodos , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Femenino , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente , Diseño de Prótesis/efectos adversos , Rango del Movimiento Articular/fisiología , Estudios Retrospectivos , Tibia/cirugía
19.
Knee Surg Sports Traumatol Arthrosc ; 26(11): 3368-3376, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29556891

RESUMEN

PURPOSE: Neutral lower limb alignment does not necessarily produce a horizontal joint line after total knee arthroplasty (TKA). The orientation of the pre- and postoperative tibial mechanical axes (TMAs-G), tibial component, and joint line relative to the ground were evaluated. METHODS: The study group included 46 knees, 23 posterior-stabilized (PS) and 23 bicruciate-stabilized (BCS) TKAs. Using whole-leg standing radiographs, the static orientation of the pre- and postoperative TMAs-G and the tibial component as well as the postoperative alignment were measured. Applying image-matching techniques, the dynamic coronal orientation of the tibial component and joint line over the stance phase of gait were analysed. The correlation between static and dynamic orientation of the tibial component and differences in the joint line between the PS and BCS TKAs were evaluated. RESULTS: In standing, the postoperative TMA-G (0.8° ± 2.8°) and tibial component (1.5° ± 2.4°) were laterally tilted with a strong correlation. The preoperative lateral tilt of the TMA-G (7.9° ± 5.1°) was a significant predictor of the postoperative TMA-G. The lateral tilt of the tibial component increased to 5.1° ± 2.4° on dynamic analysis, and was moderately correlated to static orientation. The dynamic orientation of the joint line was smaller for the BCS (1.8° ± 2.4°) compared to the PS (5.5° ± 2.7°) TKA. CONCLUSION: Even with a mechanically well-aligned TKA, a lateral tilt of the tibial component was identified due to the lateral tilt of the postoperative TMA-G and the stance phase of gait. The BCS can better accommodate the residual lateral tilt of the joint line due to the 3° medial inclination of the joint surfaces of the implant. This study increases the awareness of surgeons regarding the possibility of the coronal joint line orientation to influence preoperative TMA-G and be accommodated by articular surface design, even in mechanically aligned TKA. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Marcha/fisiología , Articulación de la Rodilla/diagnóstico por imagen , Tibia/diagnóstico por imagen , Anciano , Diseño Asistido por Computadora , Femenino , Humanos , Articulación de la Rodilla/fisiopatología , Prótesis de la Rodilla , Masculino , Periodo Posoperatorio , Periodo Preoperatorio , Radiografía , Tibia/fisiología
20.
J Orthop Surg Res ; 13(1): 9, 2018 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-29325577

RESUMEN

BACKGROUND: No clear trend has emerged from the literature regarding three-dimensional (3D) translations of the humerus relative to the scapula in shoulders with rotator cuff tears (RCTs). The purpose of this study was to evaluate the kinematics of RCT shoulders using 3D-to-two-dimensional (2D) model-to-image registration techniques. METHODS: Dynamic glenohumeral kinematics during scapular plane abduction and axial rotation were analyzed in 11 RCT patients and 10 healthy control subjects. We measured the 3D kinematic parameters of glenohumeral joints using X-ray images and CT-derived digitally reconstructed radiographs. RESULTS: For scapular plane abduction, the humeral head center was positioned significantly more medially in shoulders with RCTs than in controls at 135° of humeral abduction (p = 0.02; RCTs versus controls: - 0.9 ± 1.6 versus 0.3 ± 1.3 mm). There was no significant difference in the superior/inferior translation of the humeral head center (p = 0.99). For axial rotation in adducted position, the humeral head center was positioned significantly more anteriorly in shoulders with RCTs than in controls at - 30° of glenohumeral external rotation (p < 0.0001; RCTs versus controls: 3.0 ± 1.7 versus 0.3 ± 1.5 mm). CONCLUSIONS: This study revealed the kinematics of shoulders with large to massive full-thickness RCTs: the humeral head center showed a medial shift at the late phase of scapular plane full abduction, and an anterior shift at the internal rotation position during full axial rotation. The kinematic data in this study, which describe the patterns of movement of shoulders with large to massive full-thickness RCTs, provide valuable information for future studies investigating glenohumeral translations in other pathological conditions of the shoulder. For clinical relevance, quantitative assessment of the dynamic kinematics of shoulders with RCTs might be a therapeutic indicator for achieving functional restoration.


Asunto(s)
Lesiones del Manguito de los Rotadores/fisiopatología , Articulación del Hombro/fisiopatología , Adulto , Anciano , Fenómenos Biomecánicos , Estudios de Casos y Controles , Femenino , Humanos , Cabeza Humeral/diagnóstico por imagen , Cabeza Humeral/patología , Cabeza Humeral/fisiopatología , Imagenología Tridimensional/métodos , Masculino , Radiografía , Rango del Movimiento Articular , Rotación , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/patología , Articulación del Hombro/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...