Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Trauma Case Rep ; 51: 101010, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38600911

RESUMEN

Impalement injuries are rare and complex problems, often involving multiple organ injuries. An 18-year-old male was admitted to our emergency department after a car accident. Positioned in the right-side recumbent position, he had a 4.5 cm diameter pipe penetrating from his left abdomen to his back. Given the pipe's length exceeding the CT gantry's capacity, further imaging tests were not feasible. Consequently, the patient proceeded directly to the operating room without preoperative imaging. Before laparotomy, a left thoracotomy was conducted for aortic cross-clamping, anticipating uncontrollable bleeding during pipe removal. The subsequent laparotomy, with the patient in the right-side recumbent position, revealed the pipe impaling through the mesentery of the descending colon without evident major vessel injury. The pipe was cautiously extracted. The patient was subsequently discharged on day 26. The absence of imaging feasibility emphasized that current hemodynamic stability does not rule out the potential for significant vessel injury. Therefore, the sequential approach of left thoracotomy for aortic cross-clamping followed by laparotomy emerges as a potentially beneficial strategy in cases of transabdominal impalement. The impalement injury requires our preparedness and flexibility, which should be tailored to the individual case.

2.
Int J Surg Case Rep ; 115: 109247, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38219514

RESUMEN

INTRODUCTION: Soft coagulation is a hemostatic system of electrosurgical units that automatically regulates its output to avoid carbonization or incision. This system is widely used in invasive procedures, including thoracic surgery. Few reports exist on the harmful effects of these devices. Herein, we encountered a case of an esophagopleural fistula caused by soft coagulation. PRESENTATION OF CASE: A 74-year-old man with a history of bladder cancer was diagnosed with a tumor in the right lower lung lobe 2.5 cm in diameter. A thoracoscopic right lower lobectomy with lymph node dissection was performed. During surgery, hemostasis using soft coagulation was performed on the right wall of the lower esophagus. Eight days after surgery, thoracoscopic empyema curettage and drainage were performed. Three days after the second surgery, an esophageal fistula was identified. Suturing for the esophageal fistula and omentoplasty were performed. Suture failure occurred and an esophagobronchial fistula developed after the third surgery, which was reduced by drainage, antibiotics, and enteral nutrition. The fistula was finally addressed by fibrin glue filling in its cavity. DISCUSSION: Soft coagulation helps manage hemostasis and contributes to safe surgery. However, it may cause severe complications owing to the unpredictable spread of heat denaturation. It is suspected that delayed esophageal perforation was caused by an unnoticed heat injury to the deeper layer of the esophageal wall. CONCLUSION: There have been no reports of esophagus injury caused by soft coagulation exept for our experience. Although soft coagulation is a useful device owing to its excellent hemostatic capacity, the spread of heat denaturation may cause unpredictable tissue damage. Extra caution should be observed when using this device for hemostasis.

3.
Gen Thorac Cardiovasc Surg ; 70(7): 673-676, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35384592

RESUMEN

Azygos vein aneurysm (AVA) is necessary to prevent pulmonary embolism due to the outflow of a thrombus or rupture of the aneurysm. However, there is no established modality to assess the properties of AVA. Time-resolved three-dimensional phase-contrast magnetic resonance imaging (4D-flow MRI) has been used to examine the hemodynamics in various fields. We report a case of AVA to evaluate the flow variability and adhesions of surrounding tissues using 4D-flow MRI. The findings of the study suggested aneurysm turbulence and the absence of thrombi. The cine image, which showed a sliding wall synchronized to the heartbeat, indicated no adhesion to the superior vena cava. Based on these results, the thoracoscopic approach was deemed possible preoperatively. Thoracoscopic AVA resection was performed, and the postoperative course was uneventful. This study documented the utility of 4D-flow MRI for a detailed evaluation of AVA.


Asunto(s)
Aneurisma , Vena Ácigos , Vena Ácigos/diagnóstico por imagen , Vena Ácigos/cirugía , Hemodinámica , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética , Vena Cava Superior
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA