Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
PLOS Glob Public Health ; 2(7): e0000466, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36962526

RESUMEN

BACKGROUND: The Nigeria AIDS Indicator and Impact Survey (NAIIS), a cross-sectional household survey, was conducted in 2018 with primary objectives to estimate HIV prevalence, HIV-1 incidence, and status of UNAIDS 90-90-90 cascade. We conducted retrospective analysis of the performance of HIV rapid tests and the national HIV testing algorithm used in Nigeria. METHODS: The national algorithm included Determine HIV-1/2 as test 1 (T1), Unigold HIV-1/2 as test 2 (T2), and StatPak HIV-1/2 as the tie-breaker test (T3). Individuals reactive with T1 and either T2 or T3 were considered HIV-positive. HIV-positive specimens from the algorithm were further confirmed for the survey using supplemental test Geenius HIV-1/2. If Geenius did not confirm HIV-positive status, HIV-1 Western blot was performed. We calculated the concordance between tests and positive predictive value (PPV) of the algorithm on unweighted data. RESULTS: Of 204,930 participants (ages ≥18 months) 5,103 (2.5%) were reactive on T1. Serial testing of T1 reactive specimens with T2 or if needed by tiebreaker T3 identified 2958 (1.44%) persons as HIV-positive. Supplemental testing confirmed 2,800 (95%) as HIV-positive (HIV-1 = 2,767 [98.8%]; HIV-2 = 5 [0.2%]; dual infections = 22 [0.8%]). Concordance between T1 and T2 was 56.6% while PPV of the national algorithm was 94.5%. CONCLUSIONS: Our results show high discordant rates and poor PPV of the national algorithm with a false-positive rate of about 5.5% in the NAIIS survey. Considering our findings have major implications for HIV diagnosis in routine HIV testing services, additional evaluation of testing algorithm is warranted in Nigeria.

2.
PLOS Glob Public Health ; 2(11): e0001077, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36962660

RESUMEN

Human Immunodeficiency Virus (HIV) diagnosis remains the gateway to HIV care and treatment. However, due to changes in HIV prevalence and testing coverage across different geopolitical zones, it is crucial to evaluate the national HIV testing algorithm as false positivity due to low prevalence could be detrimental to both the client and the service delivery. Therefore, we evaluated the performance of the national HIV rapid testing algorithm using specimens collected from multiple HIV testing services (HTS) sites and compared the results from different HIV prevalence levels across the six geopolitical zones of Nigeria. The evaluation employed a dual approach, retrospective, and prospective. The retrospective evaluation focused on a desktop review of program data (n = 492,880) collated from patients attending routine HTS from six geopolitical zones of Nigeria between January 2017 and December 2019. The prospective component utilized samples (n = 2,895) collected from the field at the HTS and tested using the current national serial HIV rapid testing algorithm. These samples were transported to the National Reference Laboratory (NRL), Abuja, and were re-tested using the national HIV rapid testing algorithm and HIV-1/2 supplementary assays (Geenius to confirm positives and resolve discordance and multiplex assay). The retrospective component of the study revealed that the overall proportion of HIV positives, based on the selected areas, was 5.7% (28,319/492,880) within the study period, and the discordant rate between tests 1 and 2 was 1.1%. The prospective component of the study indicated no significant differences between the test performed at the field using the national HIV rapid testing algorithm and the re-testing performed at the NRL. The comparison between the test performed at the field using the national HIV rapid testing algorithm and Geenius HIV-1/2 supplementary assay showed an agreement rate of 95.2%, while that of the NRL was 99.3%. In addition, the comparison of the field results with HIV multiplex assay indicated a sensitivity of 96.6%, the specificity of 98.2%, PPV of 97.0%, and Kappa Statistic of 0.95, and that of the NRL with HIV multiplex assay was 99.2%, 99.4%, 99.0%, and 0.99, respectively. Results show that the Nigeria national serial HIV rapid testing algorithm performed very well across the target settings. However, the algorithm's performance in the field was lower than the performance outcomes under a controlled environment in the NRL. There is a need to target testers in the field for routine continuous quality improvement implementation, including refresher trainings as necessary.

3.
Afr J Lab Med ; 4(1): 1-17, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-38440307

RESUMEN

Background: Non-cold chain-dependent HIV rapid testing has been adopted in many resource-constrained nations as a strategy for reaching out to populations. HIV rapid test kits (RTKs) have the advantage of ease of use, low operational cost and short turnaround times. Before 2005, different RTKs had been used in Nigeria without formal evaluation. Between 2005 and 2007, a study was conducted to formally evaluate a number of RTKs and construct HIV testing algorithms. Objectives: The objectives of this study were to assess and select HIV RTKs and develop national testing algorithms. Method: Nine RTKs were evaluated using 528 well-characterised plasma samples. These comprised 198 HIV-positive specimens (37.5%) and 330 HIV-negative specimens (62.5%), collected nationally. Sensitivity and specificity were calculated with 95% confidence intervals for all nine RTKs singly and for serial and parallel combinations of six RTKs; and relative costs were estimated. Results: Six of the nine RTKs met the selection criteria, including minimum sensitivity and specificity (both ≥ 99.0%) requirements. There were no significant differences in sensitivities or specificities of RTKs in the serial and parallel algorithms, but the cost of RTKs in parallel algorithms was twice that in serial algorithms. Consequently, three serial algorithms, comprising four test kits (BundiTM, DetermineTM, Stat-Pak® and Uni-GoldTM) with 100.0% sensitivity and 99.1% - 100.0% specificity, were recommended and adopted as national interim testing algorithms in 2007. Conclusion: This evaluation provides the first evidence for reliable combinations of RTKs for HIV testing in Nigeria. However, these RTKs need further evaluation in the field (Phase II) to re-validate their performance.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...