Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Adv ; 9(11): eadf7595, 2023 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-36921059

RESUMEN

Thermal fluctuations often impose both fundamental and practical measurement limits on high-performance sensors, motivating the development of techniques that bypass the limitations imposed by thermal noise outside cryogenic environments. Here, we theoretically propose and experimentally demonstrate a measurement method that reduces the effective transducer temperature and improves the measurement precision of a dynamic impulse response signal. Thermal noise-limited, integrated cavity optomechanical atomic force microscopy probes are used in a photothermal-induced resonance measurement to demonstrate an effective temperature reduction by a factor of ≈25, i.e., from room temperature down as low as ≈12 K, without cryogens. The method improves the experimental measurement precision and throughput by >2×, approaching the theoretical limit of ≈3.5× improvement for our experimental conditions. The general applicability of this method to dynamic measurements leveraging thermal noise-limited harmonic transducers will have a broad impact across a variety of measurement platforms and scientific fields.

2.
Nano Lett ; 22(11): 4325-4332, 2022 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-35579622

RESUMEN

Thermal properties of materials are often determined by measuring thermalization processes; however, such measurements at the nanoscale are challenging because they require high sensitivity concurrently with high temporal and spatial resolutions. Here, we develop an optomechanical cantilever probe and customize an atomic force microscope with low detection noise ≈1 fm/Hz1/2 over a wide (>100 MHz) bandwidth that measures thermalization dynamics with ≈10 ns temporal resolution, ≈35 nm spatial resolution, and high sensitivity. This setup enables fast nanoimaging of thermal conductivity (η) and interfacial thermal conductance (G) with measurement throughputs ≈6000× faster than conventional macroscale-resolution time-domain thermoreflectance acquiring the full sample thermalization. As a proof-of-principle demonstration, 100 × 100 pixel maps of η and G of a polymer particle are obtained in 200 s with a small relative uncertainty (<10%). This work paves the way to study fast thermal dynamics in materials and devices at the nanoscale.

3.
Commun Phys ; 4(1)2021.
Artículo en Inglés | MEDLINE | ID: mdl-38680632

RESUMEN

All physical oscillators are subject to thermodynamic and quantum perturbations, fundamentally limiting measurement of their resonance frequency. Analyses assuming specific ways of estimating frequency can underestimate the available precision and overlook unconventional measurement regimes. Here we derive a general, estimation-method-independent Cramer Rao lower bound for a linear harmonic oscillator resonance frequency measurement uncertainty, seamlessly accounting for the quantum, thermodynamic and instrumental limitations, including Fisher information from quantum backaction- and thermodynamically-driven fluctuations. We provide a universal and practical maximum-likelihood frequency estimator reaching the predicted limits in all regimes, and experimentally validate it on a thermodynamically-limited nanomechanical oscillator. Low relative frequency uncertainty is obtained for both very high bandwidth measurements (≈ 10-5 for τ=30µs) and measurements using thermal fluctuations alone (<10-6). Beyond nanomechanics, these results advance frequency-based metrology across physical domains.

4.
Artículo en Inglés | MEDLINE | ID: mdl-33093932

RESUMEN

Plasmonic tip-sample junctions, at which the incident and scattered optical fields are localized and optimally enhanced, are often exploited to achieve ultrasensitive and highly spatially localized tip-enhanced Raman scattering (TERS). Recent work has demonstrated that the sensitivity and spatial resolution that are required to probe single molecules are attainable in such platforms. In this work, we observe and rationalize comparable TERS from few-layer WSe2 single crystals exfoliated onto Au- and Cr-coated Si substrates, using a plasmonic TERS probe excited with a 638 nm laser. Our experimental observations are supported by finite-difference time-domain simulations that illustrate that the attainable field enhancement factors at the Au-Au and Au-Cr tip-sample junctions are comparable in magnitude. Through a combined experimental and theoretical analysis, we propose that besides Au/Ag, several metallic substrates may be used to record bright TERS spectral images.

5.
Nano Lett ; 20(5): 3050-3057, 2020 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-32250636

RESUMEN

Microfabricated mechanical resonators enable precision measurement techniques from atomic force microscopy to emerging quantum applications. The resonance frequency-based physical sensing combines high precision with long-term stability. However, widely used Si3N4 resonators suffer from frequency sensitivity to temperature due to the differential thermal expansion vs the Si substrates. Here we experimentally demonstrate temperature- and residual stress-insensitive 16.51 MHz tuning fork nanobeam resonators with nonlinear clamps defining the stress and frequency by design, achieving a low fractional frequency sensitivity of (2.5 ± 0.8) × 10-6 K-1, a 72× reduction. On-chip optical readout of resonator thermomechanical fluctuations allows precision frequency measurement without any external excitation at the thermodynamically limited frequency Allan deviation of ≈7 Hz/Hz1/2 and (relative) bias stability of ≈10 Hz (≈ 0.6 × 10-6) above 1 s averaging, remarkably, on par with state-of-the-art driven devices of similar mass. Both the resonator stabilization and the passive frequency readout can benefit a wide variety of micromechanical sensors.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...