1.
J Synchrotron Radiat ; 28(Pt 5): 1476-1491, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34475295

RESUMEN

The first X-ray Extended Range Technique (XERT)-like experiment at the Australian Synchrotron, Australia, is presented. In this experiment X-ray mass attenuation coefficients are measured across an energy range including the zinc K-absorption edge and X-ray absorption fine structure (XAFS). These high-accuracy measurements are recorded at 496 energies from 8.51 keV to 11.59 keV. The XERT protocol dictates that systematic errors due to dark current nonlinearities, correction for blank measurements, full-foil mapping to characterize the absolute value of attenuation, scattering, harmonics and roughness are measured over an extended range of experimental parameter space. This results in data for better analysis, culminating in measurement of mass attenuation coefficients across the zinc K-edge to 0.023-0.036% accuracy. Dark current corrections are energy- and structure-dependent and the magnitude of correction reached 57% for thicker samples but was still large and significant for thin samples. Blank measurements scaled thin foil attenuation coefficients by 60-500%; and up to 90% even for thicker foils. Full-foil mapping and characterization corrected discrepancies between foils of up to 20%, rendering the possibility of absolute measurements of attenuation. Fluorescence scattering was also a major correction. Harmonics, roughness and bandwidth were explored. The energy was calibrated using standard reference foils. These results represent the most extensive and accurate measurements of zinc which enable investigations of discrepancies between current theory and experiments. This work was almost fully automated from this first experiment at the Australian Synchrotron, greatly increasing the possibility for large-scale studies using XERT.

2.
J Synchrotron Radiat ; 28(Pt 5): 1492-1503, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34475296

RESUMEN

High-accuracy X-ray mass attenuation coefficients were measured from the first X-ray Extended Range Technique (XERT)-like experiment at the Australian Synchrotron. Experimentally measured mass attenuation coefficients deviate by ∼50% from the theoretical values near the zinc absorption edge, suggesting that improvements in theoretical tabulations of mass attenuation coefficients are required to bring them into better agreement with experiment. Using these values the imaginary component of the atomic form factor of zinc was determined for all the measured photon energies. The zinc K-edge jump ratio and jump factor are determined and results raise significant questions regarding the definitions of quantities used and best practice for background subtraction prior to X-ray absorption fine-structure (XAFS) analysis. The XAFS analysis shows excellent agreement between the measured and tabulated values and yields bond lengths and nanostructure of zinc with uncertainties of from 0.1% to 0.3% or 0.003 Što 0.008 Å. Significant variation from the reported crystal structure was observed, suggesting local dynamic motion of the standard crystal lattice. XAFS is sensitive to dynamic correlated motion and in principle is capable of observing local dynamic motion beyond the reach of conventional crystallography. These results for the zinc absorption coefficient, XAFS and structure are the most accurate structural refinements of zinc at room temperature.

3.
Acta Crystallogr A Found Adv ; 75(Pt 3): 527-540, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-31041908

RESUMEN

A characterization of the Cu Kα1,2 spectrum is presented, including the 2p satellite line, Kα3,4, the details of which are robust enough to be transferable to other experiments. This is a step in the renewed attempts to resolve inconsistencies in characteristic X-ray spectra between theory, experiment and alternative experimental geometries. The spectrum was measured using a rotating anode, monolithic Si channel-cut double-crystal monochromator and backgammon detector. Three alternative approaches fitted five Voigt profiles to the data: a residual analysis approach; a peak-by-peak fit; and a simultaneous constrained method. The robustness of the fit is displayed across three spectra obtained with different instrumental broadening. Spectra were not well fitted by transfer of any of three prior characterizations from the literature. Integrated intensities, line widths and centroids are compared with previous empirical fits. The novel experimental setup provides insight into the portability of spectral characterizations of X-ray spectra. From the parameterization, an estimated 3d shake probability of 18% and a 2p shake probability of 0.5% are reported.