1.
J Radiol Prot ; 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38701771

RESUMEN

Given the new recommendations for occupational eye lens doses, various lead glasses have been used to reduce irradiation of interventional radiologists. However, the protection afforded by lead glasses over prescription glasses (thus over-glasses-type eyewear) has not been considered in detail. We used a phantom to compare the protective effects of such eyewear and regular eyewear of 0.07-mm lead-equivalent thickness. The shielding rates behind the eyewear and on the surface of the left eye of an anthropomorphic phantom were calculated. The left eye of the phantom was irradiated at various angles and the shielding effects were evaluated. We measured the radiation dose to the left side of the phantom using RPLDs attached to the left eye and to the surface/back of the left eyewear. Over-glasses-type eyewear afforded good protection against X-rays from the left and below; the average shielding rates on the surface of the left eye ranged from 0.70-0.72. In clinical settings, scattered radiation is incident on physicians' eyes from the left and below, and through any gap in lead glasses. Over-glasses-type eyewear afforded better protection than regular eyewear of the same lead-equivalent thickness at the irradiation angles of concern in clinical settings. Although clinical evaluation is needed, we suggest over-glasses-type Pb eyewear even for physicians who do not wear prescription glasses. .

2.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 80(3): 279-286, 2024 Mar 20.
Artículo en Japonés | MEDLINE | ID: mdl-38311432

RESUMEN

PURPOSE: The objective of this study was to compare the temperature dependence of a scintillation survey meter with and without the temperature compensation function. Investigation of temperature dependence is important to make precise measurements in various environments. METHOD: The experiment was conducted using the NaI (Tl) scintillation survey meter with the temperature compensation function (TCS-1172) and the NaI (Tl) and CsI (Tl) scintillation survey meters without the temperature compensation function (TCS-171, PDR-111). In all, 1 cm dose equivalent rate (µSv/h) was measured by changing the room temperature from 10 to 40 degree Celsius. RESULT: The results showed that the scintillation survey meter with the temperature compensation function had almost no change in the measured values with changes in room temperature, whereas the 1 cm dose equivalent rate of the scintillation survey meter without the temperature compensation function changed by a maximum of -7.2 (%/10°C) as temperature increased. CONCLUSION: This study confirms that the scintillation survey meter with the temperature compensation function was less dependent on temperature, and stable measurement was possible. However, it was suggested that the scintillation survey meter without the temperature compensation function might cause a drop in the measured value as the temperature rises.


Asunto(s)
Temperatura , Encuestas y Cuestionarios
3.
Tohoku J Exp Med ; 262(1): 45-49, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38346746

RESUMEN

A moment magnitude (Mw) 7.5 earthquake (the Global IDentifire (GLIDE) number: # Q-2024-000001-JPN) struck the Noto Peninsula of Ishikawa Prefecture on 1 January 2024 at 16:10 (Japan Standard Time). The reversed fault, 150 km in length and subducting beneath the peninsula, resulted in maximum seismic intensity 7 shaking, triggered the tsunami, destroyed over 43 thousand buildings, and disrupted roads and lifelines. The disaster claimed 236 deaths, including 15 indirect disaster deaths as of Jan. 28, 2024. There were Disaster Base Hospitals (DBHs) in the region, which survived structurally but suffered from impaired functions and the surge of medical needs of affected people. The disaster medical system of Japan immediately responded and coordinated the hundreds of emergency medical teams (EMTs), i.e., the Japan Disaster Medical Assistance Team (DMAT), from all over the country. Tohoku University Hospital, which had the experience of the 2011 Great East Japan Earthquake (GEJE), joined the coordinated response, dispatching a chain of DMATs, which helped the medical and public health coordination in Wajima City. The medical and public health needs included injuries, non-communicable diseases, infectious diseases, mental health issues, and maternal and child health issues, which were similar in the affected communities in GEJE. Although the actual damage far exceeded expectations, the structural retrofitting and business continuity plans of DBHs and the coordinated response of the national disaster medical system enhanced the effectiveness of medical and public health response.


Asunto(s)
Planificación en Desastres , Desastres , Terremotos , Niño , Humanos , Hospitales Universitarios , Tsunamis , Japón
4.
J Radiol Prot ; 43(4)2023 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-37939385

RESUMEN

The diagnostic reference level (DRL) is an effective tool for optimising protection in medical exposures to patients. However regarding air kerma at the patient entrance reference point (Ka,r), one of the DRL quantities for endoscopic retrograde cholangiopancreatography (ERCP), manufacturers use a variety of the International Electrotechnical Commission and their own specific definitions of the reference point. The research question for this study was whetherKa,ris appropriate as a DRL quantity for ERCP. The purpose of this study was to evaluate the difference betweenKa,rand air kerma incident on the patient's skin surface (Ka,e) at the different height of the patient couch for a C-arm system. Fluoroscopy and radiography were performed using a C-arm system (Ultimax-i, Canon Medical Systems, Japan) and a over-couch tube system (CUREVISTA Open, Fujifilm Healthcare, Japan).Ka,ewas measured by an ion chamber placed on the entrance surface of the phantom. Kerma-area product (PKA) andKa,rwere measured by a built-inPKAmeter and displayed on the fluoroscopy system.Ka,edecreased whileKa,rincreased as the patient couch moved away from the focal spot. The uncertainty of theKa,e/Ka,rratio due to the different height of the patient couch was estimated to be 75%-94%.Ka,rmay not accurately representKa,e.PKAwas a robust DRL quantity that was independent of the patient couch height. We cautioned against optimising patient doses in ERCP with DRLs set in terms ofKa,rwithout considering the patient couch height of the C-arm system. Therefore, we recommend thatKa,ris an inappropriate DRL quantity in ERCP using the C-arm system.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica , Niveles de Referencia para Diagnóstico , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Dosis de Radiación , Fluoroscopía , Radiografía
5.
Diagnostics (Basel) ; 13(18)2023 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-37761370

RESUMEN

Although interventional radiology (IVR) is preferred over surgical procedures because it is less invasive, it results in increased radiation exposure due to long fluoroscopy times and the need for frequent imaging. Nurses engaged in cardiac IVR receive the highest lens radiation doses among medical workers, after physicians. Hence, it is important to measure the lens exposure of IVR nurses accurately. Very few studies have evaluated IVR nurse lens doses using direct dosimeters. This study was conducted using direct eye dosimeters to determine the occupational eye dose of nurses engaged in cardiac IVR, and to identify simple and accurate methods to evaluate the lens dose received by nurses. Over 6 months, in a catheterization laboratory, we measured the occupational dose to the eyes (3 mm dose equivalent) and neck (0.07 mm dose equivalent) of nurses on the right and left sides. We investigated the relationship between lens and neck doses, and found a significant correlation. Hence, it may be possible to estimate the lens dose from the neck badge dose. We also evaluated the appropriate position (left or right) of eye dosimeters for IVR nurses. Although there was little difference between the mean doses to the right and left eyes, that to the right eye was slightly higher. In addition, we investigated whether it is possible to estimate doses received by IVR nurses from patient dose parameters. There were significant correlations between the measured doses to the neck and lens, and the patient dose parameters (fluoroscopy time and air kerma), implying that these parameters could be used to estimate the lens dose. However, it may be difficult to determine the lens dose of IVR nurses accurately from neck badges or patient dose parameters because of variation in the behaviors of nurses and the procedure type. Therefore, neck doses and patient dose parameters do not correlate well with the radiation eye doses of individual IVR nurses measured by personal eye dosimeters. For IVR nurses with higher eye doses, more accurate measurement of the radiation doses is required. We recommend that a lens dosimeter be worn near the eyes to measure the lens dose to IVR nurses accurately, especially those exposed to relatively high doses.

6.
J Radiat Res ; 64(5): 804-810, 2023 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-37549961

RESUMEN

The purpose of this study was to estimate the internal dose of radiation in Japanese macaques (aka Nihonzaru or snow monkey) due to the Fukushima nuclear power plant accident. Images of a male Japanese macaque weighing ~10 kg were acquired using a multi-slice computed tomography (CT) scan with a 64-row segment detector. The CT images were used to create voxel phantoms of the bones, bone marrow, brain, eyes, heart, lungs, stomach, liver, spleen, pancreas, kidneys, intestines, bladder, testes, thyroid and miscellaneous tissue. The Particle and Heavy Ion Transport System (PHITS) Monte Carlo code was used to calculate the internal exposure rate conversion factors for 134Cs, 137Cs and 131I isotopes for the created voxel phantoms with a statistical precision higher than 1%. The PHITS-calculated energy deposits were compared with those for rhesus monkeys. The results showed that the fractions of energy deposits for ß-radiation in different organs were almost identical between the two species. For γ-radiation, there was excellent agreement in the self-absorption rate with the approximate curve of the Japanese macaque, with an average deviation of 2%. The maximum deviation of 12% was for the kidney, which has two organs, so the error with the approximate curve is slightly larger due to the energy loss created between organs.


Asunto(s)
Radioisótopos de Cesio , Radiometría , Animales , Radioisótopos de Cesio/análisis , Radioisótopos de Yodo/análisis , Macaca fuscata , Método de Montecarlo , Fantasmas de Imagen , Dosis de Radiación , Radiometría/métodos
7.
Am J Biol Anthropol ; 181(3): 352-363, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36919625

RESUMEN

OBJECTIVES: To explore the impact of modernization on oxidative stress during a momentous health transition process, we investigated differences in oxidative stress among the indigenous populations of villages in northern Laos with different levels of modernization. METHODS: We conducted a cross-sectional study of 380 adults in three villages with different levels of modernization. Three biomarkers related to oxidative stress were measured: urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG) and 8-isoprostane concentrations (both measured by liquid chromatography-tandem mass spectrometry), and blood telomere length (measured with qPCR). We examined associations between village-level modernization and oxidative stress-related biomarkers in a multilevel analysis including a random effect and covariates. RESULTS: The geometric means of urinary 8-OHdG and 8-isoprostane concentrations were 2.92 and 0.700 µg/g creatinine, respectively, in our study population. Higher urinary 8-OHdG concentrations and shorter telomeres were observed in participants from the more modernized villages, whereas urinary 8-isoprostane concentrations did not differ significantly among villages. CONCLUSIONS: Our findings imply that modernization-induced changes in lifestyle may increase oxidative DNA damage. Baseline levels of oxidative lipid damage are expected to be high in the indigenous populations of northern Laos. Assessments of oxidative stress may provide valuable insights into the mechanisms of health transition in specific populations.


Asunto(s)
Desoxiguanosina , Estrés Oxidativo , Adulto , Humanos , Estudios Transversales , Laos , 8-Hidroxi-2'-Desoxicoguanosina/farmacología , Biomarcadores , Pueblos Indígenas
8.
Bioengineering (Basel) ; 10(2)2023 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-36829753

RESUMEN

Mobile radiography allows for the diagnostic imaging of patients who cannot move to the X-ray examination room. Therefore, mobile X-ray equipment is useful for patients who have difficulty with movement. However, staff are exposed to scattered radiation from the patient, and they can receive potentially harmful radiation doses during radiography. We estimated occupational exposure during mobile radiography using phantom measurements. Scattered radiation distribution during mobile radiography was investigated using a radiation survey meter. The efficacy of radiation-reducing methods for mobile radiography was also evaluated. The dose decreased as the distance from the X-ray center increased. When the distance was more than 150 cm, the dose decreased to less than 1 µSv. It is extremely important for radiological technologists (RTs) to maintain a sufficient distance from the patient to reduce radiation exposure. The spatial dose at eye-lens height increases when the bed height is high, and when the RT is short in stature and abdominal imaging is performed. Maintaining sufficient distance from the patient is also particularly effective in limiting radiation exposure of the eye lens. Our results suggest that the doses of radiation received by staff during mobile radiography are not significant when appropriate radiation protection is used. To reduce exposure, it is important to maintain a sufficient distance from the patient. Therefore, RTs should bear this is mind during mobile radiography.

9.
Sci Total Environ ; 868: 161516, 2023 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-36646220

RESUMEN

OBJECTIVES: To investigate determinants of oxidative stress in an indigenous population, we examined associations of trace element exposures and dietary patterns with three oxidative stress-related biomarkers among indigenous populations in Northern Laos. METHODS: This cross-sectional study included 341 adults from three villages with different levels of modernization. We used three oxidative stress-related biomarkers: urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG) and 8-isoprostane concentrations, which were measured using liquid chromatography-tandem mass spectrometry, and blood telomere lengths, which were measured using a quantitative polymerase chain reaction method. We used multilevel analysis to examine associations of urinary arsenic, cadmium, and selenium concentrations, their interaction terms, and wild-plant-food scores (principal component scores calculated from food consumption frequencies) with oxidative stress-related biomarkers. RESULTS: Urinary arsenic and cadmium concentrations were positively associated with urinary 8-isoprostane concentrations. Urinary selenium concentrations were positively associated with urinary 8-OHdG concentrations. Interaction terms ([arsenic or cadmium] × selenium) showed negative associations with urinary 8-OHdG and 8-isoprostane concentrations, respectively. Urinary cadmium concentrations were negatively associated with telomere lengths. Wild-plant-food scores did not exhibit associations with oxidative stress-related biomarkers. CONCLUSION: Our findings imply that exposure to arsenic and cadmium is associated with greater oxidative lipid damage, whereas selenium may attenuate arsenic-induced oxidative DNA damage and cadmium-induced oxidative lipid damage. Cadmium exposure may accelerate telomere attrition. Trace element exposure may be a determinant of oxidative stress among indigenous populations in Northern Laos.


Asunto(s)
Arsénico , Selenio , Oligoelementos , Adulto , Humanos , Oligoelementos/análisis , Arsénico/análisis , Selenio/análisis , Exposición a Riesgos Ambientales/análisis , Cadmio/análisis , Estudios Transversales , Laos , 8-Hidroxi-2'-Desoxicoguanosina/análisis , Estrés Oxidativo , Biomarcadores/metabolismo , Pueblos Indígenas , Lípidos
10.
Sensors (Basel) ; 23(1)2023 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-36617110

RESUMEN

In 2011, the International Commission on Radiological Protection (ICRP) recommended a significant reduction in the lens-equivalent radiation dose limit, thus from an average of 150 to 20 mSv/year over 5 years. In recent years, the occupational dose has been rising with the increased sophistication of interventional radiology (IVR); management of IVR staff radiation doses has become more important, making real-time radiation monitoring of such staff desirable. Recently, the i3 real-time occupational exposure monitoring system (based on RaySafeTM) has replaced the conventional i2 system. Here, we compared the i2 and i3 systems in terms of sensitivity (batch uniformity), tube-voltage dependency, dose linearity, dose-rate dependency, and angle dependency. The sensitivity difference (batch uniformity) was approximately 5%, and the tube-voltage dependency was <±20% between 50 and 110 kV. Dose linearity was good (R2 = 1.00); a slight dose-rate dependency (~20%) was evident at very high dose rates (250 mGy/h). The i3 dosimeter showed better performance for the lower radiation detection limit compared with the i2 system. The horizontal and vertical angle dependencies of i3 were superior to those of i2. Thus, i3 sensitivity was higher over a wider angle range compared with i2, aiding the measurement of scattered radiation. Unlike the i2 sensor, the influence of backscattered radiation (i.e., radiation from an angle of 180°) was negligible. Therefore, the i3 system may be more appropriate in areas affected by backscatter. In the future, i3 will facilitate real-time dosimetry and dose management during IVR and other applications.


Asunto(s)
Protección Radiológica , Radiología Intervencionista , Humanos , Dosis de Radiación , Dosímetros de Radiación , Radiometría
11.
Antioxidants (Basel) ; 11(12)2022 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-36552537

RESUMEN

In the present study, we evaluated the acute response of mice exposed to IQOS aerosol, a brand-name heated tobacco product (HTP), in the lung tissue. First, the thiobarbituric acid-reactive substances (TBA-RS) value was measured as an index to assess oxidative stress, and a significant increase was observed after exposure, followed by a significant increase in the total lung GSH concentration. The stress responses induced by IQOS aerosols was then analyzed by focusing on the changes in Nrf2 and ATF4, which are transcription factors that induce the expression of genes involved in GSH biosynthesis or metabolism. Although Nrf2 activation was not observed, significant accumulation of ATF4 in the nuclear fraction was noted three hours after exposure to IQOS aerosols. Upon an examination of changes in factors in the GSH biosynthetic system, a significant increase in cystine concentration in the lung tissue was measured, and an increase in xCT expression level was observed in the cell membrane fraction three-six hours after IQOS exposure. Furthermore, characteristic changes in HO-1, a stress-response protein regulated by ATF4, was discovered six hours after IQOS exposure. Moreover, analysis of the upstream ATF4 regulatory system revealed that phosphorylation of eIF2α was enhanced in the lung cytoplasmic fraction three hours after exposure to IQOS aerosols. These findings suggest that ER stress might be induced as an early response to IQOS aerosol exposure, accompanied by the activation of the eIF2α-ATF4 axis. These intracellular changes have also been reported after exposure to combustible cigarette smoke. Thus, the acute response found in the lungs of mice in the present study demonstrate that the inhalation of aerosols from IQOS elicits a biological response similar to that of combustible cigarette smoke. In conclusion, our results provide evidence that the biological effects of HTPs, such as IQOS, cannot be ignored in the lungs.

12.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 78(11): 1306-1313, 2022 Nov 20.
Artículo en Japonés | MEDLINE | ID: mdl-36198569

RESUMEN

PURPOSE: Skin injury in patients due to radiation exposure has been a complication in percutaneous coronary intervention (PCI) for a long time. To the best of our knowledge, there have been no reports comparing radiation dose by treatment area with diagnostic reference levels (DRLs) 2020, although the radiation dose varies by treatment area in PCI. METHODS: In this study, the treatment areas were classified into four segments (i.e., AHA #1-3, AHA #4, AHA #5-10, and AHA #11-15), and each segment was compared with DRLs 2020. This retrospective study included 984 consecutive patients with single-vessel disease and non-chronic total occlusion. PCI was performed on a single device. RESULTS: The median radiation dose was 1640.8 mGy, and the radiation dose for AHA #4 was 2732.0 mGy, which was significantly higher than the other treatment areas (p<0.001). In AHA #4, the radiation dose increased due to the heavy use of the left cranial view, and the patient background contributed to the increased lesion complexity. Therefore, it was challenging to evaluate AHA #4 and the other treatment areas with a uniform DRL value. CONCLUSION: Establishing a subdivided index for each treatment area is crucial if DRLs are used as a reference during procedures and as a guide for dose optimization.


Asunto(s)
Intervención Coronaria Percutánea , Exposición a la Radiación , Humanos , Dosis de Radiación , Niveles de Referencia para Diagnóstico , Radiografía Intervencional , Fluoroscopía , Estudios Retrospectivos
13.
Sci Rep ; 12(1): 13589, 2022 08 10.
Artículo en Inglés | MEDLINE | ID: mdl-35948626

RESUMEN

The administration of a third booster dose of messenger ribonucleic acid (mRNA) vaccines against coronavirus disease 2019 (COVID-19) has progressed worldwide. Since January 2022, Japan has faced a nationwide outbreak caused by the Omicron variant, which occurred simultaneously with the progression of mass vaccination with the third booster dose. Therefore, this study evaluated the effectiveness of the third dose of vaccine by reverse transcription-polymerase chain reaction (RT-PCR) test using nasopharyngeal swab samples from adults aged ≥ 18 years tested after having close contact with COVID-19 cases between January and May 2022. Participants who completed only one dose were excluded from the study. Among the 928 enrolled participants, 139 had never been vaccinated, 609 had completed two doses, 180 had completed three doses before the swab test, and the overall RT-PCR test positivity rate in each group was 48.9%, 46.0%, and 32.2%, respectively. The vaccine effectiveness of the third dose to prevent infection after close contact was approximately 40% (95% confidence interval: 20-60%), which was the highest at 10-70 days after receiving the third dose. In conclusion, the effectiveness of the three-dose mRNA COVID-19 vaccine after close contact during the Omicron outbreak is approximately 40%.


Asunto(s)
COVID-19 , Vacunas contra la Influenza , Adulto , COVID-19/epidemiología , COVID-19/prevención & control , Vacunas contra la COVID-19 , Humanos , Japón/epidemiología , Pandemias/prevención & control , ARN Mensajero , SARS-CoV-2/genética
14.
Tohoku J Exp Med ; 258(2): 103-110, 2022 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-36002251

RESUMEN

The exact profiles of the clinical symptoms related to the SARS-CoV-2 Omicron variant (B.1.1.529) remain largely uncertain. Therefore, this study aimed to clarify the clinical manifestations of infection with this variant. We enrolled individuals who were tested by quantitative nasopharyngeal swab reverse transcription-polymerase chain reaction (RT-PCR) test at a large screening center in a city of Japan during the B.1.1.529 Omicron variant wave between January and May 2022, after contact with COVID-19 patients. Swab tests were planned to be performed approximately 4-5 days after contact. The presence of COVID-19-related symptoms was assessed at the swab test site. Among the 2,507 enrolled individuals, 943 (37.6%) were RT-PCR test-positive and 1,564 (62.4%) were test-negative. Among the 943 PCR test-positive participants, the prevalence of the symptoms was as follows: 47.3% with cough, 32.9% with sore throat, 18.4% with fatigability, 12.7% with fever of ≥ 37.5℃, 9.9% with dyspnea, 2.1% with dysosmia, and 1.4% with dysgeusia. The prevalence of cough, sore throat, dyspnea, and fatigability was higher among adults aged ≥ 18 years than among children and adolescents. The prevalence of dysosmia and dysgeusia remarkably decreased during the Omicron wave (1-3%) compared to during the pre-Omicron variant waves (15-25%). In summary, common COVID-19-related symptoms during the Omicron variant wave included cough and sore throat, followed by fatigability, fever, and dyspnea. The prevalence of most of these symptoms was higher in adults than in non-adults. The prevalence of dysosmia and dysgeusia remarkably decreased with the Omicron variant than with pre-Omicron variants.


Asunto(s)
COVID-19 , Trastornos del Olfato , Faringitis , Adolescente , COVID-19/epidemiología , Niño , Tos , Disgeusia , Disnea , Fiebre , Humanos , Japón/epidemiología , SARS-CoV-2
15.
Artículo en Inglés | MEDLINE | ID: mdl-35627812

RESUMEN

Heated tobacco products (HTPs) have become increasingly popular among smokers, especially among young adults in Japan in recent years. Assessments of secondhand tobacco smoke (SHS) exposure due to HTPs are scarce. The present study aimed to assess the urinary levels of total nicotine metabolites (TNMs) of non-smoking spouses and their children following SHS exposure due to their fathers' use of HTPs. A total of 41 families including 129 participants were recruited between 2018 and 2021. The number of non-smoking spouses and children of the fathers who smoke combustion cigarettes, the fathers who use HTPs, and the fathers who are non-users or have never smoked was 27, 66, and 36, respectively. The urinary levels of TNMs, including cotinine (Cot) and 3'-hydroxycotinine (3-OHCot), were measured using liquid chromatography/tandem mass spectrometry (LC/MS/MS). The spouses and children of fathers who use HTPs had significantly higher levels of TNMs in their urine compared to those with fathers who were non-smokers or non-users. The current study is the first to assess SHS exposure due to HTP use, and to suggest the importance of strategies to prevent exposure to SHS from HTP use in public places and educational strategies to protect non-smokers from secondhand HTP aerosol exposure in households and other private places.


Asunto(s)
Cotinina , Productos de Tabaco , Niño , Cotinina/orina , Padre , Humanos , Masculino , Nicotina , Esposos , Espectrometría de Masas en Tándem , Adulto Joven
16.
Biochem Biophys Res Commun ; 610: 43-48, 2022 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-35462100

RESUMEN

Although the amount of chemicals in heated tobacco products (HTPs) aerosols is reduced compared to conventional combustible cigarette smoke, the association between HTPs and reduced health effects remains unclear. In this study, we hypothesized that exposure to IQOS, an HTP, would increase oxidative stress and affect the secretion of inflammatory cytokines. First, C57BL/6 mice exposed to IQOS aerosols were evaluated to determine the adverse effects of IQOS exposure. IQOS exposure significantly decreased the concentration of GSH in alveolar macrophages in a dose-dependent manner and increased the percentage of GSSG in lung tissues. These results indicate that IQOS exposure increases oxidative stress, and GSH is consumed to remove oxidative stress. In addition, foamy alveolar macrophages were observed in the bronchial alveolar lavage fluid after IQOS exposure. Although the concentration of inflammatory cytokines, IL-6, and GM-CSF, in the plasma increased significantly after IQOS exposure, there were no significant changes in other cytokines. These results indicate that short-term exposure to IQOS aerosols may increase oxidative stress and induce the secretion of inflammatory cytokines. Lastly, the longer-term effects of IQOS aerosols exposure should be evaluated in the future.


Asunto(s)
Productos de Tabaco , Aerosoles , Animales , Citocinas , Ratones , Ratones Endogámicos C57BL , Estrés Oxidativo , Nicotiana , Productos de Tabaco/efectos adversos
17.
Tohoku J Exp Med ; 257(1): 1-6, 2022 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-35354690

RESUMEN

The coronavirus disease 2019 (COVID-19) pandemic, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), remained a major global health concern in 2021. To suppress the spread of infection, mass vaccinations have been performed across countries worldwide. In Japan, vaccinations of the first and second doses for most of the nation were performed during the nationwide outbreak of the B.1.617.2 (Delta) variant with the L452R spike protein mutation, and the effectiveness of the vaccinations to suppress the spread of COVID-19 among the people in Japan remains uncertain. In this study, adults aged ≥18 years, who were in contact with patients with COVID-19 and underwent nasopharyngeal swab reverse transcription-polymerase chain reaction (RT-PCR) tests during August and September 2021 at a mass screening test center in Japan, were enrolled. In this period, more than 95% of the COVID-19 infections were reportedly caused by the Delta variant. As a result, a total of 784 adults with recent contact history, including 231 (29.5%) RT-PCR test-positive cases, were enrolled. The test positivity rate was lower in individuals who had been vaccinated twice than in unvaccinated individuals (12.5% vs. 39.0%, p < 0.0001), with the risk ratio of 0.32 (95% confidence interval 0.23-0.46). The vaccine effectiveness was the highest between 7-90 days after the second vaccine dose. In conclusion, two doses of mRNA COVID-19 vaccines effectively suppressed transmission in Japan during the nationwide pandemic of the Delta variant, estimated to have prevented 50-80% of the infection.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Adolescente , Adulto , COVID-19/epidemiología , COVID-19/prevención & control , Humanos , Japón/epidemiología , Pandemias , ARN Mensajero , SARS-CoV-2/genética
18.
Tomography ; 8(1): 438-446, 2022 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-35202201

RESUMEN

It is important to evaluate the radiation eye dose (3 mm dose equivalent, Hp (3)) received by physicians during computed tomography fluoroscopy (CTF)-guided biopsy, as physicians are close to the source of scattered radiation. In this study, we measured the radiation eye dose in Hp (3) received by one physician during CTF in a timeframe of 18 months using a direct eye dosimeter, the DOSIRISTM. The physician placed eye dosimeters above and under their lead (Pb) eyeglasses. We recorded the occupational radiation dose received using a neck dosimeter, gathered CT dose-related parameters (e.g., CT-fluoroscopic acquisition number, CT-fluoroscopic time, and CT-fluoroscopic mAs), and performed a total of 95 procedures during CTF-guided biopsies. We also estimated the eye dose (Hp (3)) received using neck personal dosimeters and CT dose-related parameters. The physician eye doses (right and left side) received in terms of Hp (3) without the use of Pb eyeglasses for 18 months were 2.25 and 2.06 mSv, respectively. The protective effect of the Pb eyeglasses (0.5 mm Pb) on the right and left sides during CTF procedures was 27.8 and 37.5%, respectively. This study proved the existence of significant correlations between the eye and neck dose measurement (right and left sides, R2 = 0.82 and R2 = 0.55, respectively) in physicians. In addition, we found significant correlations between CT-related parameters, such as CT-fluoroscopy mAs, and radiation eye doses (right and left sides, R2 = 0.50 and R2 = 0.52, respectively). The eye dose of Hp (3) received in CTF was underestimated when evaluated using neck dosimeters. Therefore, we suggest that the physician involved in CTF use a direct eye dosimeter such as the DOSIRIS for the accurate evaluation of their eye lens dose.


Asunto(s)
Exposición Profesional , Médicos , Fluoroscopía , Humanos , Biopsia Guiada por Imagen , Exposición Profesional/análisis , Dosis de Radiación , Tomografía Computarizada por Rayos X
19.
Radiol Phys Technol ; 15(1): 54-62, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35067903

RESUMEN

Occupational eye dose monitoring during interventional radiology and interventional cardiology is important to avoid radiation-induced cataracts. The aim of this study was to assess the eye dose correlation with neck dose and patient-related quantities for interventional cardiology physicians and nurses. The originality of this study lies in obtaining correlations between the location of the dosimeter and eye dose radiation readings among different procedures and practitioners. The doses were measured for each procedure (18 procedures of coronary angiography and 16 procedures of percutaneous coronary intervention) using an active personal dosimeter. The eye dose for physicians was not correlated with the neck dose. The eye dose for nurses had a good correlation with the neck dose during both coronary angiography (R2 = 0.91) and percutaneous coronary intervention (R2 = 0.93). Kerma-area product values may be used for a rough estimation of the eye dose for physicians during routine coronary angiography procedures (R2 = 0.76). For nurses, the neck dose is a good proxy for the eye dose during coronary angiography and percutaneous coronary intervention procedures.


Asunto(s)
Cardiología , Cristalino , Exposición Profesional , Protección Radiológica , Humanos , Exposición Profesional/análisis , Dosis de Radiación , Protección Radiológica/métodos , Radiología Intervencionista
20.
J Radiat Res ; 63(1): 30-35, 2022 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-34718686

RESUMEN

Ionizing radiation exposure affects the redox state in vivo. Recently, whole-blood antioxidant capacity (WBAC) has been reported to decrease in a dose-dependent manner after acute total body irradiation (TBI). However, changes in WBAC after localized and chronic irradiations have not been reported. This study analyzed changes to WBAC in mice after either localized irradiation (irradiation of the left hind leg only) or chronic TBI using the i-STrap method. Leg-localized irradiation exerted limited effects on WBAC, while WBAC decreased in a dose rate-dependent manner after TBI. Further, the WBAC reached the minimum value in a shorter period at a smaller dose rate. Our results suggest that changes in WBAC do not directly reflect absorbed dose, but may reflect radiation-induced biological damage at the systemic level. This study will contribute to the understanding of radiation-induced injuries and diseases, and will facilitate the establishment of biomarkers for radiation exposure.


Asunto(s)
Enfermedad Injerto contra Huésped , Traumatismos por Radiación , Animales , Antioxidantes , Biomarcadores , Ratones , Proteínas de Unión al ARN , Irradiación Corporal Total