1.
Chemosphere ; 349: 140970, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38114020

RESUMEN

Per- and polyfluoroalkyl substances (PFASs) are a group of emerging contaminants, that have a wide range of applications in industrial and commercial products. The direct discharge of untreated industrial and domestic wastewater into freshwater bodies is a common practice in developing countries, which are the main contributors to PFASs in the aquatic environment. The situation is further worsened due to poor wastewater treatment facilities and weak enforcement of environmental regulations in countries like Pakistan. The current study was designed to assess PFASs contamination in muscle tissues of edible fish species from major tributaries of the Indus System, including Head Panjnad (HP), Head Trimmu (HT), Chashma Barrage (CB), Head Blloki (HB) and Head Qadirabad (HQ). The analysis of target PFAS was performed using ultrahigh-performance liquid chromatography coupled with a quadrupole Orbitrap high-resolution mass spectrometry. The highest levels of ∑17PFASs were observed in S. seenghala, C. mirigala from HB, and C. mirigala from HQ with a mean value of 45.4 ng g-1, 43.7 ng g-1, and 40.8 ng g-1, respectively. Overall, the compositional profile of fish samples was predominated by long-chain PFASs such as PFOA, PFOS, PFHpS, and PFDS. The accumulation of PFASs in fish species is dependent on the physiochemical properties of PFASs, characteristics of the aquatic environment, and fish species. Significant associations of PFASs with isotopic composition (p < 0.05), feeding habits (p < 0.05), and zones (p < 0.05) indicate that dietary proxies could be an important predictor of PFASs distribution among species. The C7-C10 PFASs exhibited bio-accumulative tendency with an accumulation factor ranging from 0.5 to 3.4. However, none of the fish samples had sufficiently high levels of PFOS to cause human health risk (HR < 1). For future studies, it is s recommended to conduct seasonal monitoring and the bioaccumulation pattern along trophic levels of both legacy and emerging PFASs.


Asunto(s)
Ácidos Alcanesulfónicos , Fluorocarburos , Contaminantes Químicos del Agua , Animales , Humanos , Agua/análisis , Ácidos Alcanesulfónicos/análisis , Pakistán , Fluorocarburos/análisis , Contaminantes Químicos del Agua/análisis , Peces , Monitoreo del Ambiente
2.
Sci Total Environ ; 856(Pt 2): 159144, 2023 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-36183770

RESUMEN

Per- and polyfluoroalkyl substances (PFASs) are a large group of chemicals reported in global environment and are responsible for various adverse impacts on humans and environment. We report a comprehensive study on occurrence of PFASs, including legacy, substitute and emerging ones, from Pakistan. Surface water samples were collected from five ecologically important freshwater reservoirs in Pakistan, namely, Head Panjnad (HP), Head Trimmu (HT), Chashma Barrage (CB), Head Blloki (HB), and Head Qadirabad (HQ). The detection frequencies of PFASs ranged between 37 %-100 %. The highest concentration of ∑15PFASs was detected at HP (114.1 ng L-1), whereas the lowest at HQ (19.9 ng L-1). Among the analyzed PFASs, 6:2 fluorotelomer sulfonic acid (6:2 FTS) and perfluorooctanoic acid (PFOA) showed maximum mean concentrations of 9.1 ng L-1 and 7 ng L-1 at HP, followed by Perfluorooctane sulfonic acid (PFOS) with level of 0.99 ng L-1 at HT. The ecological risk assessment for selected species i.e., daphnid, mysid, fish and green algae showed that PFOS, perfluorononanoic acid (PFNA), perfluorodecanoic acid (PFDA) exhibited moderate risk i.e., Hazard Quotients (HQs) < 1 to the modeled organisms, whereas perfluorobutane sulfonic acid (PFBS) showed the high risk to green algae (HQs = 8.6) and PFOA presented a high risk to all the organisms (HQs ranged between 1.04 and 7.38). The level of ∑PFASs at HP (114.1 ng L-1) exceed the EU guideline value of ∑PFASs in water (100 ng L-1), however the risk quotient (RQmix) values of all age groups were < 1 implying that the detected PFASs in water do not pose risk to human health. Source apportionment through Positive Matrix Factorization (PMF) showed that industrial effluent is the main source of PFASs in freshwater reservoirs. Comparable concentrations of legacy and substitute PFASs in this study indicate that legacy PFASs are still in use adjacent to ecologically important water reservoirs.


Asunto(s)
Ácidos Alcanesulfónicos , Fluorocarburos , Contaminantes Químicos del Agua , Animales , Humanos , Fluorocarburos/análisis , Monitoreo del Ambiente , Contaminantes Químicos del Agua/análisis , Pakistán , Ácidos Alcanesulfónicos/análisis , Agua Dulce , Ácidos Sulfónicos , Agua , China
3.
Med Eng Phys ; 69: 8-16, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31229384

RESUMEN

In this study, a multi-objective topology optimization method has been formulated and carried out for various resection types, with minimization of a weighted sum of the compliance (maximized stiffness) under six routine activities of daily life as the objective function and volume reduction as a constraint. Unique prosthetic geometries with low weight and remarkable strength closely matching the pelvic bone shape were obtained. The strength of the optimized implants was investigated through finite element analysis and it has been found that the initial geometries of the optimized implants could withstand the static loading conditions of various routine activities having less stress concentration areas. A 3D printed patient-specific topology optimized hemi-pelvic prosthesis has been designed based on the proposed method and implanted successfully in a patient with pelvic sarcoma. Therefore, pelvic prostheses can be designed and then manufactured via additive manufacturing technologies with the minimum material in less time and having robust mechanical fixation responses. Conclusively, the topology optimization method used for the design of pelvic prostheses improves the biomechanical performance of the implants with reduced weight and higher stiffness than the traditional implants. Including the topology optimization procedure in the phase of designing patient-specific pelvic implants is therefore, highly recommended.


Asunto(s)
Análisis de Elementos Finitos , Huesos Pélvicos , Diseño de Prótesis/métodos , Humanos , Masculino , Persona de Mediana Edad , Huesos Pélvicos/cirugía , Resistencia al Corte , Estrés Mecánico
4.
Proc Inst Mech Eng H ; 231(6): 525-533, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28639517

RESUMEN

The aim of this study was to design a hemi-pelvic prosthesis for a patient affected by pelvic sarcoma. To investigate the biomechanical functionality of the pelvis reconstructed with designed custom-made prosthesis, a patient-specific finite element model of whole pelvis with primary ligaments inclusive was constructed based on the computed tomography images of the patient. Then, a finite element analysis was performed to calculate and compare the stress distribution between the normal and implanted pelvis models when undergoing three different static conditions-both-leg standing, single-leg standing for the healthy and the affected one. No significant differences were observed in the stresses between the normal and reconstructed pelvis for both-leg standing, but 20%-40% larger stresses were predicted for the peak stress of the single-leg standing (affected side). Moreover, two- to threefold of peak stresses were predicted within the prostheses compared to that of the normal pelvis especially for single-leg standing case, however, still below the allowable fatigue limitation. The study on the load transmission functionality of prosthesis indicated that it is crucial to carry out finite element analysis for functional evaluation of the designed customized prostheses before three-dimensional printing manufacturing, allowing better understanding of the possible peak stresses within the bone as well as the implants for safety precaution. The finite element model can be equally applicable to other bone tumor model for biomechanical studying.


Asunto(s)
Neoplasias Óseas/terapia , Análisis de Elementos Finitos , Huesos Pélvicos , Diseño de Prótesis/métodos , Fenómenos Biomecánicos , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/fisiopatología , Humanos , Huesos Pélvicos/diagnóstico por imagen , Huesos Pélvicos/fisiopatología , Impresión Tridimensional , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...