Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Jpn J Radiol ; 34(10): 691-699, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27566608

RESUMEN

PURPOSE: To assess whether 320-section low-dose dynamic volume computed tomography (320-LDVCT) with adaptive iterative dose reduction (AIDR) adds value to 3-T MRI for the preoperative evaluation of brain tumors. METHODS: The study population was comprised of 16 consecutive patients with brain tumors who, in addition to preoperative 3-T MRI, underwent 320-LDVCT with AIDR. Two radiologists independently evaluated the CT and MRI studies; one measured the relative cerebral blood volume (rCBV) in the tumor and contralateral brain on CT and MR perfusion maps. Interobserver agreement was assessed by κ statistics. RESULTS: In 3 of 16 patients (19 %), 320-LDVCT added diagnostic value to 3-T MRI studies with respect to the visualization of feeders (κ = 0.77), and in 12 (75 %) it helped the delineation of venous structures (κ = 0.71) and the relationship between the tumor and adjacent vessels (κ = 0.85). The average standardized rCBV value was 12.2 ± 2.40 (range 0.7-36.6) on MR and 8.80 ± 2.77 (range 0.8-38.0) on CT perfusion studies; the correlation between these values was very strong (r = 0.92, p < 0.0001). According to the neurosurgeons, 320-LDVCT added helpful information for surgery in 4 patients (25 %). CONCLUSION: The 320-LDVCT can add value to 3-T MRI for the tumor feeders and relationship between the tumor and adjacent vessels.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Neovascularización Patológica/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Volumen Sanguíneo , Neoplasias Encefálicas/cirugía , Medios de Contraste , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Periodo Preoperatorio , Dosis de Radiación
2.
Magn Reson Med Sci ; 15(3): 335-9, 2016 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-26701696

RESUMEN

Contrast inherent inflow-enhanced multi-phase angiography combining multiple-phase flow-alternating inversion-recovery (CINEMA-FAIR) is an arterial-spin-labeling-based four-dimensional magnetic resonance angiography (4D-MRA) technique. Two neuroradiologists independently evaluated the depiction of the intracranial vasculatures in healthy subjects with 3T 4D-MRA using CINEMA-FAIR. Our results indicated that this technique can provide good visualization of the cerebral arteries with a high spatial and temporal resolution. It appears to have sufficient resolution for identifying flow difference in the anterior and posterior circulation in healthy subjects.


Asunto(s)
Circulación Sanguínea/fisiología , Arterias Cerebrales/diagnóstico por imagen , Arterias Cerebrales/fisiología , Trastornos Cerebrovasculares/diagnóstico por imagen , Trastornos Cerebrovasculares/diagnóstico , Angiografía por Resonancia Magnética/métodos , Adulto , Femenino , Voluntarios Sanos , Humanos , Masculino , Marcadores de Spin
3.
J Comput Assist Tomogr ; 40(2): 290-6, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26599964

RESUMEN

OBJECTIVE: We aimed to assess the usefulness of 3-T 4-dimensional (4D) arterial spin-labeling (ASL)-based magnetic resonance angiography (MRA) with color-coded time-of-arrival (TOA) maps for the evaluation of cerebral arteriovenous malformations (AVMs). METHODS: Our study included 6 patients with cerebral AVMs. They underwent 4D-ASL MRA at 3T and digital subtraction angiography. A pseudocontinuous arterial spin labeling protocol with look-locker sampling was used for spin labeling. Two independent readers reviewed the 4D-ASL MRA images with color-coded TOA maps for the nidus size, arterial feeders, and venous drainage. Two other readers consensually reviewed the digital subtraction angiography images. RESULTS: The cerebral AVMs were demonstrated on all 4D-ASL MRA images. In 5 high-flow AVMs, the color-coded TOA maps were especially useful for identifying the feeder/drainer. Intermodality agreement was excellent for the nidus size (κ = 1.0), very good for arterial feeders (κ = 0.88), and good for venous drainage (κ = 0.80). CONCLUSIONS: The 4D-ASL 3-T MRA with color-coded TOA maps is useful for assessing the gross angiographic characteristics of intracranial AVMs.


Asunto(s)
Imagenología Tridimensional/métodos , Malformaciones Arteriovenosas Intracraneales/patología , Angiografía por Resonancia Magnética/métodos , Marcadores de Spin , Adolescente , Adulto , Anciano , Angiografía de Substracción Digital , Mapeo Encefálico/métodos , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Adulto Joven
4.
Clin Radiol ; 70(9): 960-5, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26059270

RESUMEN

AIM: To evaluate whether 3-T four-dimensional (4D) arterial spin-labelling (ASL) -based magnetic resonance angiography (MRA) is useful for assessing the collateral circulation via the circle of Willis in patients with carotid artery steno-occlusive disease. MATERIALS AND METHODS: Institutional review board approval and prior written informed consent from all patients were obtained. The inclusion criteria were fulfilled by 13 patients with carotid artery steno-occlusive disease. All underwent 4D-ASL MRA at 3 T and digital subtraction angiography (DSA). The flow-sensitive alternating inversion recovery (FAIR) preparation scheme with look-locker sampling was used for spin labeling. At 300-ms intervals seven dynamic scans were obtained with a spatial resolution of 0.5×0.5×0.6 mm(3). The collateral flow via the circle of Willis was read on 4D-ASL MRA and DSA images by two sets of two independent readers each. κ statistics were used to assess interobserver and intermodality agreement. RESULTS: On DSA, collateral flow via the anterior communicating artery (AcomA) was observed in six patients, via the posterior communicating artery (PcomA) in four patients, and via both the AcomA and PcomA in three patients. With respect to the qualitative evaluation of 4D-ASL MRA images, interobserver agreement was excellent for all items (κ=1). 4D-ASL MRA and DSA consensus readings agreed on the type of collateral flow pattern in 10 of the 13 patients (77%). Intermodality agreement was good (κ=0.606; 95% confidence interval (CI): 0.215-0.997). CONCLUSION: 3 T 4D-ASL MRA may be a useful tool for the evaluation of the collateral circulation in patients with carotid artery steno-occlusive disease.


Asunto(s)
Estenosis Carotídea/diagnóstico , Círculo Arterial Cerebral , Circulación Colateral , Angiografía por Resonancia Magnética/métodos , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Marcadores de Spin
5.
Jpn J Radiol ; 33(6): 353-9, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25952405

RESUMEN

PURPOSE: To compare conventional CT angiography (CTA) and CTA reconstructed from CT perfusion source data (perfusion CTA) acquired on a 320-section CT scanner for the evaluation of intracranial arteries. MATERIALS AND METHODS: Our study included 7 patients who had undergone trapping of an intracranial aneurysm and placement of a bypass. All underwent conventional and perfusion CTA and digital subtraction angiography (DSA). Using DSA as the gold standard, 2 radiologists evaluated 10 arterial segments on conventional and perfusion CTA images. On a 4-point scale they independently scored the image quality and vascular visualization of the intracranial arteries on the conventional and perfusion CTA images. The effective radiation dose to each patient was also recorded. RESULTS: A total of 65 arterial segments without apparent abnormalities were assessed. While the mean image quality score tended to be slightly higher for conventional than perfusion CTA, there was no significant difference. The effective dose for perfusion and conventional CTA with unenhanced CT was 4.2 mSv and 3.1 mSv, respectively, for all patients. CONCLUSION: For the evaluation of intracranial arteries using DSA as the gold standard, perfusion CTA yields image quality and vascular visualization similar to conventional CTA at an acceptable radiation dose.


Asunto(s)
Angiografía Cerebral/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Angiografía de Substracción Digital , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Magn Reson Med Sci ; 14(4): 285-93, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25994036

RESUMEN

PURPOSE: We compared gross characterization of intracranial dural arteriovenous fistulas (DAVFs) between unenhanced 3-tesla 3-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) and digital subtraction angiography (DSA). METHODS: We subjected 26 consecutive patients with intracranial DAVF to unenhanced 3T 3D TOF MRA and to DSA. Two independent sets of observers inspected the main arterial feeders, fistula site, and venous drainage pattern on MRA and DSA images. Interobserver and intermodality agreements were assessed by k statistics. RESULTS: Interobserver agreement was excellent for fistula site (κ = 0.919; 95% confidence interval [CI], 0.805 to 1.000), good for main arterial feeders (κ = 0.711; 95% CI, 0.483 to 0.984), and very good for venous drainage (κ = 0.900; 95% CI, 0.766 to 1.000). Intermodality agreement was excellent for fistula site (κ = 0.968; 95% CI, 0.906 to 1.000) and good for main arterial feeder (κ = 0.809; 95% CI, 0.598 to 1.000) and venous drainage (κ = 0.837; 95% CI, 0.660 to 1.000). CONCLUSION: Gross characterization of intracranial DAVF was similar for both imaging modalities, but unenhanced 3T 3D TOF MRA cannot replace DSA.


Asunto(s)
Angiografía de Substracción Digital/estadística & datos numéricos , Malformaciones Vasculares del Sistema Nervioso Central/diagnóstico , Imagenología Tridimensional/estadística & datos numéricos , Angiografía por Resonancia Magnética/estadística & datos numéricos , Neuroimagen/estadística & datos numéricos , Adulto , Anciano , Fístula Arteriovenosa/diagnóstico , Fístula Arteriovenosa/diagnóstico por imagen , Seno Cavernoso/anomalías , Malformaciones Vasculares del Sistema Nervioso Central/diagnóstico por imagen , Duramadre/irrigación sanguínea , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Malformaciones Arteriovenosas Intracraneales/diagnóstico , Malformaciones Arteriovenosas Intracraneales/diagnóstico por imagen , Masculino , Arterias Meníngeas/anomalías , Persona de Mediana Edad , Variaciones Dependientes del Observador , Hueso Occipital/irrigación sanguínea , Arteria Oftálmica/anomalías , Reproducibilidad de los Resultados , Seno Sagital Superior/anomalías , Senos Transversos/anomalías
7.
Radiology ; 271(1): 193-9, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24475797

RESUMEN

PURPOSE: To evaluate whether 3-T four-dimensional (4D) arterial spin-labeling (ASL)-based magnetic resonance (MR) angiography is useful for the evaluation of shunt lesions in patients with intracranial dural arteriovenous fistulas (AVFs). MATERIALS AND METHODS: Institutional review board approval and prior written informed consent from all patients were obtained. Nine patients with intracranial dural AVF (seven men, two women; age range, 52-77 years; mean age, 63 years) underwent 4D ASL MR angiography at 3 T and digital subtraction angiography (DSA). Spin tagging was with flow-sensitive alternating inversion recovery with Look-Locker sampling. At 300-millisecond intervals, seven dynamic images with a spatial resolution of 0.5 × 0.5 × 0.6 mm(3) were obtained. The 4D ASL MR angiographic and DSA images were read by two sets of two independent readers each. Interobserver and intermodality agreement was assessed with the κ statistic. RESULTS: On all 4D ASL MR angiographic images, the major intracranial arteries were demonstrated at a temporal resolution of 300 milliseconds. Interobserver agreement was excellent for the fistula site (κ = 1.00; 95% confidence interval [CI]: 1.00, 1.00), moderate for the main arterial feeders (κ = 0.53; 95% CI: 0.08, 0.98), and good for venous drainage (κ = 0.77; 95% CI: 0.35, 1.00). Intermodality agreement was excellent for the fistula site and venous drainage (κ = 1.00; 95% CI: 1.00, 1.00) and good for the main arterial feeders (κ = 0.80; 95% CI: 0.58, 1.00). CONCLUSION: The good-to-excellent agreement between 3-T 4D ASL MR angiographic and DSA findings suggests that 3-T 4D ASL MR angiography is a useful tool for the evaluation of intracranial dural AVFs.


Asunto(s)
Malformaciones Vasculares del Sistema Nervioso Central/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Anciano , Angiografía de Substracción Digital , Medios de Contraste , Femenino , Humanos , Yopamidol , Masculino , Persona de Mediana Edad , Marcadores de Spin
8.
Jpn J Radiol ; 31(9): 600-7, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23771696

RESUMEN

PURPOSE: To determine whether sufficient pre-surgical treatment information of unruptured intracranial aneurysms can be obtained by using 320-row detector CT angiography (CTA) alone. MATERIALS AND METHODS: We enrolled 40 consecutive patients with unruptured intracranial aneurysms. All patients were prospectively conducted to perform 320-detector CTA as the only preoperative modality. Two blinded readers independently assessed CTA images. Interobserver agreement and the agreement between CTA and surgical findings were determined by calculating the κ coefficient. The referring neurosurgeons judged the usefulness of the information provided by CTA for treatment decisions. RESULTS: All patients had surgery without intraarterial digital subtraction angiography. Agreement between CTA and surgical findings was excellent for the aneurysm location (κ = 1.0) and good for the shape (κ = 0.71), neck (κ = 0.74) and its relationship with adjacent branches (κ = 0.71). Information obtained with 320-detector CTA was highly useful for surgical treatment in 37 of 40 (93 %) patients, although small perforators deriving from the aneurysm in 2 cases were not fully visualized on CTA images. CONCLUSION: In most patients with unruptured intracranial aneurysms, sufficient pre-surgical treatment information can be obtained by using 320-detector CTA alone.


Asunto(s)
Angiografía Cerebral/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Cuidados Preoperatorios/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Medios de Contraste , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Aneurisma Intracraneal/cirugía , Yopamidol , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados
9.
J Comput Assist Tomogr ; 37(3): 338-42, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23674002

RESUMEN

OBJECTIVE: The purpose of this study was to determine how the gray-to-white matter contrast in healthy subjects changes on high-b-value diffusion-weighted imaging (DWI) acquired at 3 T and evaluate whether high-b-value DWI at 3 T is useful for the detection of cortical lesions in inflammatory brain diseases. METHODS: Ten healthy volunteers underwent DWI at b = 1000, 2000, 3000, 4000, and 5000 s/mm(2) on a 3-T MRI unit. On DW images, 1 radiologist performed region-of-interest measurements of the signal intensity of 8 gray matter structures. The gray-to-white matter contrast ratio (GWCR) was calculated. Ten patients with inflammatory cortical lesions were also included. All patients underwent conventional MRI and DWI at b = 1000 and 3000 s/mm(2). Using a 4-point grading system, 2 radiologists independently assessed the presence of additional information on DW images compared with fluid-attenuated inversion recovery images. Interobserver agreement was assessed by κ statistics. RESULTS: In the healthy subjects, the b value increased as the GWCR decreased in all evaluated gray matter structures. On DW images acquired at b = 3000 s/mm(2), mean GWCR was less than 1.0 in 7 of 8 structures. For both reviewers, DWI at b = 3000 s/mm(2) yielded significantly more additional information than did DWI at b = 1000 s/mm(2) (P < 0.05). Interobserver agreement for DWI at b = 1000 s/mm(2) and b = 3000 s/mm(2) was fair (κ = 0.35) and excellent (κ = 1.0), respectively. CONCLUSIONS: At 3-T DWI, the gray-to-white matter contrast in most gray matter structures reverses at b = 3000 s/mm. In the evaluation of cortical lesions in patients with inflammatory brain diseases, 3-T DWI at b = 3000 s/mm was more useful than b = 1000 s/mm(2).


Asunto(s)
Encefalopatías/diagnóstico , Encéfalo/anatomía & histología , Imagen de Difusión por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Inflamación/diagnóstico , Masculino , Persona de Mediana Edad , Valores de Referencia , Estadísticas no Paramétricas
10.
Acta Radiol ; 54(5): 493-7, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23436827

RESUMEN

BACKGROUND: The placement of detachable coil has become the alternative method of treating visceral arterial aneurysms (VAAs). Imaging follow-up is necessary after coil embolization because of frequent incomplete occlusion. PURPOSE: To compare contrast-enhanced magnetic resonance angiography (CE-MRA) at 3T with a reference standard of digital subtraction angiography (DSA) for the evaluation of VAAs after coil embolization. MATERIAL AND METHODS: We treated 15 patients with VAA with coil embolization; eight had splenic artery aneurysms and seven had renal artery aneurysms. We packed the aneurysmal sac preserving native arterial circulation. For follow-up, all patients underwent CE-MRA at 3T and DSA. The results were classified according to coil occlusion: Class 1, complete occlusion; Class 2, residual neck; Class 3, aneurysmal filling. RESULTS: CE-MRA revealed 11 complete occlusions and four residual necks. DSA follow-up showed 12 complete occlusions and three residual necks. No aneurysmal filling occurred after treatment. Comparison of CE-MRA and DSA findings showed 93% agreement (14/15). CE-MRA allowed the detection of a residual neck in one misclassified case in which DSA showed occlusion. Coil-related artifacts were minimal and did not interfere with evaluation of the occlusion status of the VAAs. CONCLUSION: CE-MRA at 3T provides high-quality images equivalent to DSA for the evaluation of VAAs after coil embolization. We suggest that CE-MRA at 3T might be used as the primary method for follow-up of VAAs after coil embolization.


Asunto(s)
Aneurisma/terapia , Embolización Terapéutica/métodos , Angiografía por Resonancia Magnética/métodos , Arteria Renal , Arteria Esplénica , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Artefactos , Medios de Contraste , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
11.
J Vasc Interv Radiol ; 22(8): 1139-43, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21801993

RESUMEN

The present report describes a technique of simultaneous confluent balloon inflation in cases in which conventional subintimal angioplasty failed. Eight patients with peripheral vascular occlusive disease (n = 4 each with iliac arterial lesions and superficial femoral arterial lesions) of clinical category 3-5 received treatment with the confluent two-balloon technique. Recanalization was successfully completed with this technique in all eight patients, without any major complications. All patients with claudication and rest pain were relieved of their symptoms, and both patients with ulcers showed improvement.


Asunto(s)
Angioplastia de Balón/métodos , Arteriopatías Oclusivas/terapia , Arteria Femoral , Arteria Ilíaca , Enfermedades Vasculares Periféricas/terapia , Anciano , Anciano de 80 o más Años , Angiografía , Arteriopatías Oclusivas/diagnóstico por imagen , Femenino , Humanos , Masculino , Enfermedades Vasculares Periféricas/diagnóstico por imagen , Estudios Retrospectivos , Resultado del Tratamiento , Grado de Desobstrucción Vascular
12.
Acta Radiol ; 51(4): 383-8, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20192896

RESUMEN

BACKGROUND: Cisplatin is one of the most effective chemotherapeutic agents against a variety of human cancers. Its usefulness is limited by its toxicity to normal tissues, including cells of kidney proximal tubules. PURPOSE: To evaluate the effect of sodium thiosulfate (STS) on cisplatin clearance after transcatheter embolization (TAE) with a lipiodol-platinum suspension (LPS) in patients with hepatocellular carcinoma (HCC). MATERIAL AND METHODS: The study was performed prospectively in a randomized manner. HCC patients underwent intra-arterial LPS embolization with (n=17) and without (n=15) an intravenous STS infusion. Renal toxicity was estimated and free and total platinum concentrations were assessed for 7 days after treatment. RESULTS: After treatment without STS, there was a mild elevation of serum creatinine and a decrease in creatinine clearance. With STS, there was no significant difference before and after treatment in mean serum creatinine and creatinine clearance; free platinum disappeared completely within 120 min. In patients treated without STS, free platinum decreased rapidly within 120 min; this was followed by a gradual decrease during the next 7 days. CONCLUSION: STS seems effective against the renal toxicity of cisplatin. However, in the presence of STS, the anticancer effect of cisplatin may be decreased due to the accelerated disappearance of platinum.


Asunto(s)
Antineoplásicos/farmacocinética , Carcinoma Hepatocelular/tratamiento farmacológico , Quelantes/farmacología , Quimioembolización Terapéutica , Cisplatino/farmacocinética , Enfermedades Renales/prevención & control , Neoplasias Hepáticas/tratamiento farmacológico , Tiosulfatos/farmacología , Anciano , Anciano de 80 o más Años , Antineoplásicos/efectos adversos , Antineoplásicos/uso terapéutico , Cisplatino/efectos adversos , Cisplatino/uso terapéutico , Femenino , Humanos , Aceite Yodado/efectos adversos , Aceite Yodado/farmacocinética , Aceite Yodado/uso terapéutico , Riñón/efectos de los fármacos , Riñón/metabolismo , Enfermedades Renales/inducido químicamente , Enfermedades Renales/metabolismo , Masculino , Persona de Mediana Edad , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...