J Abdom Wall Surg ; 3: 13114, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38974808

RESUMEN

Purpose: To determine normal anatomical variation of abdominal wall musculature. Methods: A retrospective analysis of CT scans was performed on adults (>18 years) with normal abdominal wall muscles. Two radiologists analysed the images independently. Distances from three fixed points in the midline were measured. The fixed points were; P1, mid-way between xiphoid and umbilicus, P2, at the umbilicus, and P3, mid-way between umbilicus and pubic symphysis. From these three fixed points the following measurements were recorded; midline to lateral innermost border of the abdominal wall musculature, midline to lateral edge of rectus abdominis muscle, and midline to medial edges of all three lateral abdominal wall muscles. To obtain aponeurotic width, rectus abdominis width was subtracted from the distance to medial edge of lateral abdominal wall muscle. Results: Fifty normal CT scan were evaluated from between March 2023 to August 2023. Mean width of external oblique aponeurosis at P1 was 16.2 mm (IQR 9.2 mm to 20.7 mm), at P2 was 23.5 mm (IQR 14 mm to 33 mm), and at P3 no external oblique muscle was visible. Mean width of the internal oblique aponeurosis at P1 was 32.1 mm (IQR 17.5 mm to 45 mm), at P2 was 10.13 (IQR 1 mm to 17.5 mm), and at P3 was 9.2 mm (IQR 3.0 mm to 13.7 mm). Mean width of the transversus abdominis aponeurosis at P1 was -25.1 mm (IQR 37.8 mm to -15.0 mm), at P2 was 29.4 mm (IQR 20 mm to 39.8 mm), and at P3 was 20.3 mm (IQR 12 mm to 29 mm). Conclusion: In this study we describe normal anatomical variation of the abdominal wall muscles. Assessing this variability on the pre-operative CT scans of ventral hernia patients allows for detailed operative planning and decision making.

3.
Respirology ; 25(4): 443-448, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31407464

RESUMEN

BACKGROUND AND OBJECTIVE: Continuous positive airway pressure (CPAP) is the most common treatment for obstructive sleep apnoea (OSA), but many patients fail long-term therapy. Bilevel positive airway pressure (BPAP) is a potential alternative. We hypothesized that BPAP could improve treatment adherence and outcomes in patients who cannot tolerate CPAP. METHODS: Patients with OSA who failed CPAP (usage < 4 h/day) and were referred to a tertiary sleep centre between 2014 and 2017 for BPAP were included. Age, gender, body mass index (BMI), co-morbidities, CPAP use and reasons for failure, Epworth Sleepiness Scale (ESS), sleep study data, spirometry data and average maximum nightly compliance were recorded. RESULTS: A total of 52 patients with OSA requiring CPAP > 15 cm H2 O (71% male, age: 58 (15) years, BMI: 42.6 (10.1) kg/m2 , apnoea-hypopnoea index (AHI): 51.1 (30.4)/h) were studied; 62% had respiratory co-morbidities affecting nocturnal breathing including obesity hypoventilation syndrome and COPD; 25% had neuromuscular conditions; and 17% had cardiovascular disease. CPAP was used for 199 (106-477) days prior to referral for BPAP. Reasons for CPAP failure were intolerant pressures (23%), uncontrolled symptoms (23%), mask problems (21%), adverse effects (13%), claustrophobia (8%), co-morbidities (8%) and other issues (4%). Lower expiratory positive airway pressures were needed with BPAP compared to CPAP (10 (8-12) vs 16.8 (15.7-19.2) cm H2 O, P = 0.001); patients achieved better adherence to BPAP (7.0 (4.0-8.5) vs 2.5 (1.6-6.7) h/night, P = 0.028) and better symptom control (ESS: 4.0 (1.0-7.0) vs 10.0 (6.0-17.0) points, P = 0.039). CONCLUSION: In patients with moderate-severe OSA who fail CPAP therapy due to low adherence, BPAP is well tolerated and achieves sufficient control of sleep-disordered breathing and its symptoms.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua/métodos , Cooperación del Paciente , Apnea Obstructiva del Sueño/terapia , Adulto , Anciano , Femenino , Humanos , Masculino , Presiones Respiratorias Máximas , Persona de Mediana Edad , Obesidad/complicaciones , Polisomnografía , Estudios Prospectivos , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/fisiopatología
4.
Ann Med Surg (Lond) ; 48: 1-6, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31660149

RESUMEN

•There is no consensus on the optimal flexor tendon repair technique at each anatomical flexor zone.•There is paucity of high quality evidence.•Heterogenous study designs limit inter-study comparisons.•Patient reported outcome measures are crucial but there is a perennial need for robust disease-specific tools to be utilised.

5.
J Thorac Dis ; 11(5): 2153-2164, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31285910

RESUMEN

Obstructive sleep apnoea (OSA) is a global health problem of increasing prevalence. Effective treatments are available with continuous positive airway pressure (CPAP) therapy and mandibular advancement devices (MAD). However, there is limited long-term adherence to therapy, as CPAP and MAD require permanent usage to avoid recurrence of the symptoms and adverse ill health. Alternative treatments would aid in the treatment cascade to manage OSA effectively whenever standard therapy has been trialled and failed. Hypoglossal nerve stimulation (HNS), an invasive approach to stimulate the pharyngeal dilator muscles of the upper airway during sleep, has been approved for the treatment of OSA by several healthcare systems in recent years. In parallel to the development of HNS, a non-invasive approach has been developed to deliver electrical stimulation. Transcutaneous electrical stimulation in obstructive sleep apnoea (TESLA) uses non-invasive electrical stimulation to increase neuromuscular tone of the upper airway dilator muscles of patients with OSA during sleep. Data from previous feasibility studies and randomised controlled trials have helped to identify a subgroup of patients who are "responders" to this treatment. However, further investigations are required to assess usability, functionality and task accomplishment of this novel treatment. Consideration of these factors in the study design of future clinical trials will strengthen research methodology and protocols, improve patient related outcome measures and assessments, to optimise this emerging therapeutical option. In this review, we will introduce a conceptual framework for the TESLA home programme highlighting qualitative aspects and outcomes.

6.
Int J Comput Assist Radiol Surg ; 13(6): 777-786, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29603064

RESUMEN

PURPOSE: Cardiac resynchronisation therapy (CRT) is an established treatment for symptomatic patients with heart failure, a prolonged QRS duration, and impaired left ventricular (LV) function; however, non-response rates remain high. Recently proposed computer-assisted interventional platforms for CRT provide new routes to improving outcomes. Interventional systems must process information in an accurate, fast and highly automated way that is easy for the interventional cardiologists to use. In this paper, an interventional CRT platform is validated against two offline diagnostic tools to demonstrate that accurate information processing is possible in the time critical interventional setting. METHODS: The study consisted of 3 healthy volunteers and 16 patients with heart failure and conventional criteria for CRT. Data analysis included the calculation of end-diastolic volume, end-systolic volume, stroke volume and ejection fraction; computation of global volume over the cardiac cycle as well as time to maximal contraction expressed as a percentage of the total cardiac cycle. RESULTS: The results showed excellent correlation ([Formula: see text] values of [Formula: see text] and Pearson correlation coefficient of [Formula: see text]) with comparable offline diagnostic tools. CONCLUSION: Results confirm that our interventional system has good accuracy in everyday clinical practice and can be of clinical utility in identification of CRT responders and LV function assessment.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Imagenología Tridimensional , Imagen por Resonancia Cinemagnética/métodos , Cirugía Asistida por Computador/instrumentación , Función Ventricular Izquierda/fisiología , Anciano , Diseño de Equipo , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico/fisiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS