Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Rev Lett ; 130(5): 051801, 2023 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-36800472

RESUMEN

The KamLAND-Zen experiment has provided stringent constraints on the neutrinoless double-beta (0νßß) decay half-life in ^{136}Xe using a xenon-loaded liquid scintillator. We report an improved search using an upgraded detector with almost double the amount of xenon and an ultralow radioactivity container, corresponding to an exposure of 970 kg yr of ^{136}Xe. These new data provide valuable insight into backgrounds, especially from cosmic muon spallation of xenon, and have required the use of novel background rejection techniques. We obtain a lower limit for the 0νßß decay half-life of T_{1/2}^{0ν}>2.3×10^{26} yr at 90% C.L., corresponding to upper limits on the effective Majorana neutrino mass of 36-156 meV using commonly adopted nuclear matrix element calculations.

2.
Phys Rev Lett ; 122(19): 192501, 2019 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-31144924

RESUMEN

We present a precision analysis of the ^{136}Xe two-neutrino ßß electron spectrum above 0.8 MeV, based on high-statistics data obtained with the KamLAND-Zen experiment. An improved formalism for the two-neutrino ßß rate allows us to measure the ratio of the leading and subleading 2νßß nuclear matrix elements (NMEs), ξ_{31}^{2ν}=-0.26_{-0.25}^{+0.31}. Theoretical predictions from the nuclear shell model and the majority of the quasiparticle random-phase approximation (QRPA) calculations are consistent with the experimental limit. However, part of the ξ_{31}^{2ν} range allowed by the QRPA is excluded by the present measurement at the 90% confidence level. Our analysis reveals that predicted ξ_{31}^{2ν} values are sensitive to the quenching of NMEs and the competing contributions from low- and high-energy states in the intermediate nucleus. Because these aspects are also at play in neutrinoless ßß decay, ξ_{31}^{2ν} provides new insights toward reliable neutrinoless ßß NMEs.

3.
Phys Rev Lett ; 117(8): 082503, 2016 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-27588852

RESUMEN

We present an improved search for neutrinoless double-beta (0νßß) decay of ^{136}Xe in the KamLAND-Zen experiment. Owing to purification of the xenon-loaded liquid scintillator, we achieved a significant reduction of the ^{110m}Ag contaminant identified in previous searches. Combining the results from the first and second phase, we obtain a lower limit for the 0νßß decay half-life of T_{1/2}^{0ν}>1.07×10^{26} yr at 90% C.L., an almost sixfold improvement over previous limits. Using commonly adopted nuclear matrix element calculations, the corresponding upper limits on the effective Majorana neutrino mass are in the range 61-165 meV. For the most optimistic nuclear matrix elements, this limit reaches the bottom of the quasidegenerate neutrino mass region.

5.
Phys Rev Lett ; 110(6): 062502, 2013 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-23432237

RESUMEN

We present results from the first phase of the KamLAND-Zen double-beta decay experiment, corresponding to an exposure of 89.5 kg yr of (136)Xe. We obtain a lower limit for the neutrinoless double-beta decay half-life of T(1/2)(0ν)>1.9×10(25) yr at 90% C.L. The combined results from KamLAND-Zen and EXO-200 give T(1/2)(0ν)>3.4×10(25) yr at 90% C.L., which corresponds to a Majorana neutrino mass limit of <(120-250) meV based on a representative range of available matrix element calculations. Using those calculations, this result excludes the Majorana neutrino mass range expected from the neutrinoless double-beta decay detection claim in (76)Ge, reported by a part of the Heidelberg-Moscow Collaboration, at more than 97.5% C.L.

6.
Rev Sci Instrum ; 83(5): 056104, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22667668

RESUMEN

We propose an innovative demodulation scheme for coherent detectors used in cosmic microwave background polarization experiments. Removal of non-white noise, e.g., narrow-band noise, in detectors is one of the key requirements for the experiments. A combination of modulation and demodulation is used to extract polarization signals as well as to suppress such noise. Traditional demodulation, which is based on the two-point numerical differentiation, works as a first-order high pass filter for the noise. The proposed demodulation is based on the three-point numerical differentiation. It works as a second-order high pass filter. By using a real detector, we confirmed significant improvements of suppression power for the narrow-band noise. We also found improvement of the noise floor.

7.
Rev Sci Instrum ; 82(5): 054501, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21639525

RESUMEN

We present a novel system to calibrate millimeter-wave polarimeters for cosmic microwave background (CMB) polarization measurements. This technique is an extension of the conventional metal mirror rotation approach, however, it employs cryogenically-cooled blackbody absorbers. The primary advantage of this system is that it can generate a slightly polarized signal (∼100 mK) in the laboratory; this is at a similar level to that measured by ground-based CMB polarization experiments observing a ∼10 K sky. It is important to reproduce the observing condition in the laboratory for reliable characterization of polarimeters before deployment. In this paper, we present the design and principle of the system and demonstrate its use with a coherent-type polarimeter used for an actual CMB polarization experiment. This technique can also be applied to incoherent-type polarimeters and it is very promising for the next-generation CMB polarization experiments.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...