Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39143666

RESUMEN

PURPOSE: The aim of this study was to investigate the utility of native T1 and T2 mapping in the bowel to evaluate disease activity in Crohn disease (CD) using endoscopy as the reference standard. METHODS: This was a prospective study. Magnetic resonance imaging was performed by using a 1.5-T Philips scanner. We used a modified look-locker inversion recovery and a multiecho gradient-spin-echo sequences for single breath-hold native T1 and T2 maps, respectively, for the short-axis image of the intestine, and the measurement at the most severe site was compared with partial Simple Endoscopic Score for Crohn's Disease (pSES-CD, assessed by an expert endoscopist). A pSES-CD ≥ 4 indicated active disease. Statistical analyses were performed using the Student t test, Spearman correlation, and receiver operating characteristic curve analysis. RESULTS: A total of 27 patients (mean age ± standard deviation, 37 ± 18 years; 20 men, 7 women) were included in this study. The native T1 value of active disease was significantly higher than that of inactive disease (1170.8 ± 100.5 milliseconds vs 924.5 ± 95.3 milliseconds; P = 0.018), but the T2 value was not significantly different between active and inactive disease (76.1 ± 7.8 milliseconds vs 69.3 ± 10.9 milliseconds; P = 0.424). A good correlation was found between native T1 value and pSES-CD (ρ = 0.71; P < 0.001) but not between T2 value and pSES-CD (ρ = 0.06; P = 0.790). The area under the receiver operating characteristic curve for differentiating the disease activity was 0.96 (95% confidence interval [CI]: 0.90-1.00) for T1 values and 0.68 (95% confidence interval: 0.41-0.96) for T2 values. CONCLUSIONS: Native T1 mapping could be potentially used as a noninvasive method to differentiate disease activity in patients with CD and may be superior to T2 mapping for this purpose.

2.
J Phys Condens Matter ; 36(42)2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-38976987

RESUMEN

The study of phonon dynamics and its interplay with magnetic ordering is crucial for understanding the unique quantum phases in the pyrochlore iridates. Here, through inelastic x-ray scattering on a single crystal sample of the pyrochlore iridate Eu2Ir2O7, we map out the phonon excitation spectra in Eu2Ir2O7and compare them with the theoretical phonon spectra calculated using the density functional theory. Possible phonon renormalization across the magnetic long-range order transition is observed in our experiments, which is consistent with the results of the previous Raman scattering experiments.

3.
Chembiochem ; : e202400468, 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39075031

RESUMEN

DNA condensates, formed by liquid-liquid phase separation (LLPS), emerge as promising soft matter assemblies for creating artificial cells. The advantages of DNA condensates are their molecular permeability through the surface due to their membrane-less structure and their fluidic property. However, they face challenges in the design of their surface, e.g., unintended fusion and less regulation of permeable molecules. Addressing them, we report surface modification of DNA condensates with DNA origami nanoparticles, employing a Pickering-emulsion strategy. We successfully constructed core-shell structures with DNA origami coatings on DNA condensates and further enhanced the condensate stability toward fusion via connecting DNA origamis by responding to DNA input strands. The 'armoring' prevented the fusion of DNA condensates, enabling the formation of multicellular-like structures of DNA condensates. Moreover, the permeability was altered through the state change from coating to armoring the DNA condensates. The armored DNA condensates have significant potential for constructing artificial cells, offering increased surface stability and selective permeability for small molecules while maintaining compartmentalized space and multicellular organization.

4.
Phys Rev E ; 109(6-1): 064608, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39020980

RESUMEN

We report on the self-part of the Van Hove correlation function, the correlation function describing the dynamics of a single molecule, of water and deuterated water. The correlation function is determined by transforming inelastic scattering spectra of neutrons or x rays over a wide range of momentum transfer Q and energy transfer E to space R and time t. The short-range diffusivity is estimated from the Van Hove correlation function in the framework of the Gaussian approximation. The diffusivity has been found to be different from the long-range macroscopic diffusivity, providing information about local atomic dynamics.

5.
Clin Neurol Neurosurg ; 240: 108261, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38599043

RESUMEN

This report presents a case of Alexander disease showing clinical characteristics mimicking progressive supranuclear palsy (PSP). A 67-year-old woman complaining of motor disturbance exhibited severe atrophy of medulla, spinal cord, and midbrain tegmentum, as well as periventricular hyperintensity on cerebral MRI. Genetic analysis identified a novel in-frame deletion/insertion mutation in the exon 3 of the GFAP gene. Interestingly, neurological findings and decreased striatal uptake in dopamine transporter SPECT were suggestive of PSP. A novel GFAP gene mutation found in the present case may cause the unique clinical phenotype, which should be differentiated from PSP.


Asunto(s)
Enfermedad de Alexander , Proteína Ácida Fibrilar de la Glía , Imagen por Resonancia Magnética , Parálisis Supranuclear Progresiva , Humanos , Enfermedad de Alexander/genética , Enfermedad de Alexander/diagnóstico por imagen , Enfermedad de Alexander/diagnóstico , Femenino , Parálisis Supranuclear Progresiva/genética , Parálisis Supranuclear Progresiva/diagnóstico por imagen , Anciano , Proteína Ácida Fibrilar de la Glía/genética , Diagnóstico Diferencial , Tomografía Computarizada de Emisión de Fotón Único , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Mutagénesis Insercional/genética
6.
J Imaging Inform Med ; 37(1): 167-179, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38343219

RESUMEN

Deep learning (DL) has recently attracted attention for data processing in positron emission tomography (PET). Attenuation correction (AC) without computed tomography (CT) data is one of the interests. Here, we present, to our knowledge, the first attempt to generate an attenuation map of the human head via Sim2Real DL-based tissue composition estimation from model training using only the simulated PET dataset. The DL model accepts a two-dimensional non-attenuation-corrected PET image as input and outputs a four-channel tissue-composition map of soft tissue, bone, cavity, and background. Then, an attenuation map is generated by a linear combination of the tissue composition maps and, finally, used as input for scatter+random estimation and as an initial estimate for attenuation map reconstruction by the maximum likelihood attenuation correction factor (MLACF), i.e., the DL estimate is refined by the MLACF. Preliminary results using clinical brain PET data showed that the proposed DL model tended to estimate anatomical details inaccurately, especially in the neck-side slices. However, it succeeded in estimating overall anatomical structures, and the PET quantitative accuracy with DL-based AC was comparable to that with CT-based AC. Thus, the proposed DL-based approach combined with the MLACF is also a promising CT-less AC approach.

7.
Intern Med ; 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38403765

RESUMEN

Amiodarone, a prominent antiarrhythmic drug, may cause lung injury. We herein report the case of an 87-year-old man who had been taking amiodarone for 5 years and was subsequently referred due to respiratory failure. Chest computed tomography revealed multiple consolidations with air bronchograms in both lungs. Despite administering steroid pulse therapy, his respiratory failure worsened, and he died 3 days later. Autopsy revealed hyaline membrane formation and organic formation with fibrin deposition. Drug-induced lung injury caused by amiodarone was confirmed by autopsy. Caution is therefore required when fibrin deposition in the alveolar spaces is observed in such cases, which are prone to suffer a rapid deterioration.

8.
Sci Adv ; 9(36): eadh8706, 2023 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-37682990

RESUMEN

An accurate pressure scale is a fundamental requirement to understand planetary interiors. Here, we establish a primary pressure scale extending to the multimegabar pressures of Earth's core, by combined measurement of the acoustic velocities and the density from a rhenium sample in a diamond anvil cell using inelastic x-ray scattering and x-ray diffraction. Our scale agrees well with previous primary scales and shock Hugoniots in each experimental pressure range and reveals that previous scales have overestimated laboratory pressures by at least 20% at 230 gigapascals. It suggests that the light element content in Earth's inner core (the density deficit relative to iron) is likely to be double what was previously estimated, or Earth's inner core temperature is much higher than expected, or some combination thereof.

10.
J Nucl Cardiol ; 30(5): 1879-1885, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36918460

RESUMEN

BACKGROUND: The aim of this study was to estimate the impact of respiratory and electrocardiogram (ECG)-gated FDG positron emission tomography (PET)/computed tomography (CT) on the diagnosis of cardiac sarcoidosis (CS). METHODS AND RESULTS: Imaging from thirty-one patients was acquired on a PET/CT scanner equipped with a respiratory- and ECG-gating system. Non-gated PET images and three kinds of gated PET/CT images were created from identical list-mode clinical PET data: respiratory-gated PET during expiration (EX), ECG-gated PET at end diastole (ED), and ECG-gated PET at end systole (ES). The maximum standardized uptake value (SUVmax) and cardiac metabolic volume (CMV) were measured, and the locations of FDG accumulation were analyzed using a polar map. The mean SUVmax of the subjects was significantly higher after application of either respiratory-gated or ECG-gated reconstruction. Conversely, the mean CMV was significantly lower following the application of respiratory-gated or ECG-gated reconstruction. The segment showing maximum accumulation was shifted to the adjacent segment in 25.8%, 38.7%, and 41.9% of cases in EX, ED, and ES images, respectively. CONCLUSION: In FDG PET/CT scanning for the diagnosis of CS, gated scanning is likely to increase quantitative accuracy, but the effect depends on the location and synchronization method.


Asunto(s)
Infecciones por Citomegalovirus , Sarcoidosis , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones/métodos , Electrocardiografía , Sarcoidosis/diagnóstico por imagen
11.
Diagnostics (Basel) ; 13(6)2023 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-36980385

RESUMEN

The performances of photomultiplier tube (PMT)-based dedicated breast positron emission tomography (PET) and silicon photomultiplier tube (SiPM)-based time-of-flight (TOF) PET, which is applicable not only to breast imaging but also to head imaging, were compared using a phantom study. A cylindrical phantom containing four spheres (3-10 mm in diameter) filled with 18F-FDG at two signal-to-background ratios (SBRs), 4:1 and 8:1, was scanned. The phantom images, which were reconstructed using three-dimensional list-mode dynamic row-action maximum likelihood algorithm with various ß-values and post-smoothing filters, were visually and quantitatively compared. Visual evaluation showed that the 3 mm sphere was more clearly visualized with higher ß and smaller post-filters, while the background was noisier; SiPM-based TOF-PET was superior to PMT-based dbPET in sharpness, smoothness, and detectability, although the background was noisier at the SBR of 8:1. Quantitative evaluation revealed that the detection index (DI) and recovery coefficient (CRC) of SiPM-based TOF-PET images were higher than those of PMT-based PET images, despite a higher background coefficient of variation (CVBG). The two organ-specific PET systems showed that a 3 mm lesion in the breast could be visualized at the center of the detector, and there was less noise in the SiPM-based TOF-PET image.

12.
Intern Med ; 62(20): 2995-3000, 2023 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-36823081

RESUMEN

We herein report a 75-year-old woman who presented with dyspnea and purpura. She was diagnosed with eosinophilic granulomatosis with polyangiitis (EGPA) based on axonal damage observed in the left tibial nerve and skin and lung pathologies. Lung pathology showed IgG4-positive plasma cells, considered a complication of IgG4-related disease (IgG4-RD). Computed tomography revealed thickening of the abdominal aorta and a poor contrast area in the left kidney, which was indicative of IgG4-RD. Steroid administration improved the IgG4-RD. However, the EGPA resisted treatment; therefore, immunosuppressive drugs and mepolizumab were administered. Refractory EGPA complicated with IgG4-RD showed different treatment responses for each organ.


Asunto(s)
Síndrome de Churg-Strauss , Granulomatosis con Poliangitis , Enfermedad Relacionada con Inmunoglobulina G4 , Femenino , Humanos , Anciano , Enfermedad Relacionada con Inmunoglobulina G4/complicaciones , Enfermedad Relacionada con Inmunoglobulina G4/diagnóstico , Enfermedad Relacionada con Inmunoglobulina G4/tratamiento farmacológico , Granulomatosis con Poliangitis/complicaciones , Síndrome de Churg-Strauss/complicaciones , Síndrome de Churg-Strauss/diagnóstico , Síndrome de Churg-Strauss/tratamiento farmacológico , Inmunosupresores/uso terapéutico , Células Plasmáticas/patología
13.
Angew Chem Int Ed Engl ; 62(13): e202218458, 2023 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-36696593

RESUMEN

Loosely bonded ("rattling") atoms with s2 lone pair electrons are usually associated with strong anharmonicity and unexpectedly low thermal conductivity, yet their detailed correlation remains largely unknown. Here we resolve this correlation in thermoelectric InTe by combining chemical bonding analysis, inelastic X-ray and neutron scattering, and first principles phonon calculations. We successfully probe soft low-lying transverse phonons dominated by large In1+ z-axis motions, and their giant anharmonicity. We show that the highly anharmonic phonons arise from the dynamic lone pair expression with unstable occupied antibonding states induced by the covalency between delocalized In1+ 5s2 lone pair electrons and Te 5p states. This work pinpoints the microscopic origin of strong anharmonicity driven by rattling atoms with stereochemical lone pair activity, important for designing efficient materials for thermoelectric energy conversion.

15.
J Nucl Med ; 64(1): 153-158, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35798557

RESUMEN

We acquired brain 18F-FDG and 18F-flutemetamol PET images using a time-of-flight system dedicated to the head (dhPET) and a conventional whole-body PET/CT (wbPET) system and evaluated the clinical superiority of dhPET over wbPET. Methods: There were 18 subjects for the 18F-FDG PET study and 17 subjects for the 18F-flutemetamol PET study. 18F-FDG PET images were first obtained using wbPET, followed by dhPET. 18F-flutemetamol PET images were first obtained using wbPET, followed by dhPET. Images acquired using dhPET and wbPET were compared by visual inspection, voxelwise analysis, and SUV ratio (SUVR). Results: All 18F-FDG and 18F-flutemetamol images acquired using dhPET were judged as visually better than those acquired using wbPET. The voxelwise analysis demonstrated that accumulations in the cerebellum, in the lateral occipital cortices, and around the central sulcus area in dhPET 18F-FDG images were lower than those in wbPET 18F-FDG images, whereas accumulations around the ventricle systems were higher in dhPET 18F-FDG images than those in wbPET 18F-FDG images. Accumulations in the cerebellar dentate nucleus, in the midbrain, in the lateral occipital cortices, and around the central sulcus area in dhPET images were lower than those in wbPET images, whereas accumulations around the ventricle systems were higher in dhPET 18F-flutemetamol images than those in wbPET 18F-flutemetamol images. The mean cortical SUVRs of 18F-FDG and 18F-flutemetamol dhPET images were significantly higher than those of 18F-FDG and 18F-flutemetamol wbPET images, respectively. Conclusion: The dhPET images had better image quality by visual inspection and higher SUVRs than wbPET images. Although there were several regional accumulation differences between dhPET and wbPET images, understanding this phenomenon will enable full use of the features of this dhPET system in clinical practice.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía de Emisión de Positrones/métodos , Encéfalo/diagnóstico por imagen
16.
EJNMMI Phys ; 9(1): 88, 2022 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-36525103

RESUMEN

BACKGROUND: This study evaluated the physical performance of a positron emission tomography (PET) system dedicated to the head and breast according to the National Electrical Manufacturers Association (NEMA) NU2-2012 standard. METHODS: The spatial resolution, sensitivity, scatter fraction, count rate characteristics, corrections for count losses and randoms, and image quality of the system were determined. All measurements were performed according to the NEMA NU2-2012 acquisition protocols, but image quality was assessed using a brain-sized phantom. Furthermore, scans of the three-dimensional (3D) Hoffmann brain phantom and mini-Derenzo phantom were acquired to allow visual evaluation of the imaging performance for small structures. RESULTS: The tangential, radial, and axial full width at half maximum (FWHM) at a 10-mm offset in half the axial field of view were measured as 2.3, 2.5, and 2.9 mm, respectively. The average system sensitivity at the center of the field of view and at a 10-cm radial offset was 7.18 and 8.65 cps/kBq, respectively. The peak noise-equivalent counting rate was 35.2 kcps at 4.8 kBq/ml. The corresponding scatter fraction at the peak noise-equivalent counting rate was 46.8%. The peak true rate and scatter fraction at 8.6 kBq/ml were 127.8 kcps and 54.3%, respectively. The percent contrast value for a 10-mm sphere was approximately 50%. On the 3D Hoffman brain phantom image, the structures of the thin layers composing the phantom were visualized on the sagittal and coronal images. On the mini-Derenzo phantom, each of the 1.6-mm rods was clearly visualized. CONCLUSION: Taken together, these results indicate that the head- and breast-dedicated PET system has high resolution and is well suited for clinical PET imaging.

17.
Nat Commun ; 13(1): 7211, 2022 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-36433998

RESUMEN

Here we determine the compressional and shear wave velocities (vp and vs) of hexagonal close-packed iron, a candidate for the main constituent of the Earth's inner core, to pressures above 300 gigapascals using a newly designed diamond anvil cell and inelastic X-ray scattering combined with X-ray diffraction. The present results reveal that the vp and vs of the Preliminary reference Earth model (PREM) inner core are 4(±2)% and 36(±17)% slower than those of the pure iron, respectively at the centre of the core. The density and sound velocity of the PREM inner core can be explained by addition of 3(±1) wt% silicon and 3(±2) wt% sulphur to iron‒5 wt% nickel alloy. Our suggested inner core composition is consistent with the existing outer core model with oxygen, as the growth of the inner core may have created a secular enrichment of the element in the outer core.

18.
J Chem Phys ; 157(15): 154504, 2022 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-36272787

RESUMEN

Inelastic x-ray scattering spectra of four organic liquids, n-hexane, cyclohexane, ethylene glycol dimethyl ether, and 1,4-dioxane, were measured, and the sound velocity in the nm-1 wavenumber and meV energy regimes was determined. Compared with the corresponding values in the hydrodynamic limit, the sound velocity in the nm-1 regime was faster, and the positive dispersion of the longitudinal modulus was stronger in liquids composed of ring structures (cyclohexane and 1,4-dioxane) than in those of linear chain structures (n-hexane and ethylene glycol dimethyl ether). Molecular dynamics simulation of n-hexane and cyclohexane was also performed. The difference in the positive dispersion of the longitudinal modulus was reproduced by simulation, and it was elucidated by the difference in the longitudinal modulus in the q = 0 limit and the THz frequency regime. The excess part of the longitudinal modulus from the hydrodynamic limit was further divided into various contributions, and the smaller excess modulus of n-hexane was mainly ascribed to two reasons. The first one is that the shear modulus of n-hexane is smaller in the THz regime, and the second one is that the positive dispersion of the bulk modulus due to the vibrational energy relaxation is weaker. The second mechanism was further interpreted in terms of the fast vibrational energy relaxation of intramolecular modes associated with the chain deformation of n-hexane.

19.
Ann Nucl Med ; 36(11): 998-1006, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36167889

RESUMEN

OBJECTIVES: This study evaluates the phantom attenuation correction (PAC) method as an alternative to maximum-likelihood attenuation correction factor (ML-ACF) correction in time-of-flight (TOF) brain positron emission tomography (PET) studies. METHODS: In the PAC algorithm, a template emission image [Formula: see text] and a template attenuation coefficient image [Formula: see text] are prepared as a data set based on phantom geometry. Position-aligned attenuation coefficient image [Formula: see text] is derived by aligning [Formula: see text] using parameters that match the template emission image [Formula: see text] to measured emission image [Formula: see text]. Then, attenuation coefficient image [Formula: see text] combined with a headrest image is used for scatter and attenuation correction in the image reconstruction. To evaluate the PAC algorithm as an alternative to ML-ACF, Hoffman 3D brain and cylindrical phantoms were measured to obtain the image quality indexes of contrast and uniformity. These phantoms were also wrapped with a radioactive sheet to obtain attenuation coefficient images using ML-ACF. Emission images were reconstructed with attenuation correction by PAC and ML-ACF, and the results were compared using contrast and uniformity as well as visual assessment. CT attenuation correction (CT-AC) was also applied as a reference. RESULTS: The contrast obtained by ML-ACF was slightly overestimated due to its unique experimental condition for applying ML-ACF in Hoffman 3D brain phantom but the uniformity was almost equivalent among ML-ACF, CT-AC, and PAC. PAC showed reasonable result without overestimation compared to ML-ACF and CT-AC. CONCLUSIONS: PAC is an attenuation correction method that can ensure the performance in phantom test, and is considered to be a reasonable alternative to clinically used ML-ACF-based attenuation correction.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía de Emisión de Positrones , Humanos , Tomografía de Emisión de Positrones/métodos , Fantasmas de Imagen , Procesamiento de Imagen Asistido por Computador/métodos , Encéfalo/diagnóstico por imagen , Algoritmos , Imagen por Resonancia Magnética/métodos
20.
Metabolites ; 12(5)2022 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-35629900

RESUMEN

This study is to observe a thioacetamide (TAA) administered Hepatic encephalopathy (HE) model rats at three and ten days after TAA administration using liver MRI and brain MR Spectroscopy (MRS) by use of 7T-MRI. Forty-two Wistar rats (control group, n = 14) were intraperitoneally administered at 300 mg/kg (low-dose group, n = 14) or 400 mg/kg (high-dose group, n = 14) doses of TAA for induced of HE. At three days after TAA administration, glutamine (Gln) measured by MRS in high-dose and low-dose TAA groups showed significant increases in comparison to those of the control group (p < 0.05). Other metabolites measured by MRS showed no significant changes. Liver T1ρ and T2 relaxation times significantly increased three days after TAA injection compared to pre-injection. There was a correlation between Gln levels in the brain and the relaxation time of the liver. Furthermore, Gln levels and relaxation time changed depending on the TAA dose. The Gln concentration in the brain increased with the deterioration of liver function, as inferred from the prolonged relaxation time of the liver. The prolonged relaxation time of the liver corresponded with the level of Gln in the brain. Gln concentration for the alterations of brain metabolites and T1ρ relaxation time for the assessment of liver damage are useful markers for inter-organ association analysis in the HE model.