Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Case Rep Pediatr ; 2021: 2109934, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34306788

RESUMEN

A 4-month-old male infant diagnosed with Pentalogy of Cantrell presented to the cardiac catheterization laboratory with a large pericardial effusion. During an urgent pericardial drain placement, the patient, whose prior hemodynamics and clinical findings had suggested a noncritical cardiac lesion, had a profound desaturation, with echocardiography suggesting minimal or no flow across the right ventricular outflow tract (RVOT). The position of the drainage catheter on fluoroscopy and echocardiography suggested that the spell was being caused by obstruction of the main pulmonary artery (MPA) by the pericardial drain. After partially withdrawing the drain to reposition it, there was immediate resolution of the hypoxemia, and echocardiography once again showed adequate flow across the outflow tract.

2.
J Am Coll Cardiol ; 76(24): 2847-2858, 2020 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-33303074

RESUMEN

BACKGROUND: There are limited published data focused on outcomes of transcatheter pulmonary valve replacement (TPVR) with either a Sapien XT or Sapien 3 (S3) valve. OBJECTIVES: This study sought to report short-term outcomes in a large cohort of patients who underwent TPVR with either a Sapien XT or S3 valve. METHODS: Data were entered retrospectively into a multicenter registry for patients who underwent attempted TPVR with a Sapien XT or S3 valve. Patient-related, procedural, and short-term outcomes data were characterized overall and according to type of right ventricular outflow tract (RVOT) anatomy. RESULTS: Twenty-three centers enrolled a total of 774 patients: 397 (51%) with a native/patched RVOT; 183 (24%) with a conduit; and 194 (25%) with a bioprosthetic valve. The S3 was used in 78% of patients, and the XT was used in 22%, with most patients receiving a 29-mm (39%) or 26-mm (34%) valve. The implant was technically successful in 754 (97.4%) patients. Serious adverse events were reported in 67 patients (10%), with no difference between RVOT anatomy groups. Fourteen patients underwent urgent surgery. Nine patients had a second valve implanted. Among patients with available data, tricuspid valve injury was documented in 11 (1.7%), and 9 others (1.3%) had new moderate or severe regurgitation 2 grades higher than pre-implantation, for 20 (3.0%) total patients with tricuspid valve complications. Valve function at discharge was excellent in most patients, but 58 (8.5%) had moderate or greater pulmonary regurgitation or maximum Doppler gradients >40 mm Hg. During limited follow-up (n = 349; median: 12 months), 9 patients were diagnosed with endocarditis, and 17 additional patients underwent surgical valve replacement or valve-in-valve TPVR. CONCLUSIONS: Acute outcomes after TPVR with balloon-expandable valves were generally excellent in all types of RVOT. Additional data and longer follow-up will be necessary to gain insight into these issues.


Asunto(s)
Procedimientos Endovasculares/estadística & datos numéricos , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Prótesis Valvulares Cardíacas , Válvula Pulmonar , Sistema de Registros , Adolescente , Adulto , Bioprótesis , Niño , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/métodos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
3.
Eur J Cardiothorac Surg ; 54(5): 926-932, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29684119

RESUMEN

OBJECTIVES: Turner syndrome (TS) and Marfan syndrome (MFS) are partially characterized by aortopathies with a risk of developing severe aortic dilation, stiffness and consequent dissection and aneurysm formation. The incidence of a bicuspid aortic valve (BAV) is also increased in TS. We investigated aortic stiffness in teenage TS and MFS patients and evaluated to what degree stiffness in TS patients is augmented by the presence of a BAV. METHODS: Fifty-seven patients with TS (n = 37) and MFS (n = 20), as well as 22 controls with similar age and size distribution underwent evaluation of thoracic aortic stiffness using phase-contrast magnetic resonance imaging. Calculated stiffness indices including pulse wave velocity (PWV), distensibility and relative area change (RAC) were collected to characterize the ascending aorta and descending aorta. PWV was also determined to evaluate global aortic arch stiffness. RESULTS: Patients with TS had reduced distensibility (0.43 vs 0.58%/mmHg, P < 0.05) and RAC (21 vs 29%, P < 0.01) in the ascending aorta when compared with normal controls. Similarly, patients with MFS had reduced ascending aortic distensibility (0.39 vs 0.58%/mmHg, P < 0.05) and RAC (22 vs 29%, P < 0.05). There were no differences in measured PWV in the ascending aorta. Patients with TS had significantly elevated PWV measured in the aortic arch when compared with controls (2.7 vs 1.9 m/s, P < 0.05). Patients with MFS had more prominent elevation in aortic arch PWV (4.2 vs 1.9 m/s, P < 0.01). The descending aortas had decreased distensibility (0.36 vs 0.55%/mmHg, P < 0.05) and RAC (18 vs 25%, P < 0.01) only in MFS patients. Additionally, 18 TS patients with a BAV were compared with 19 TS patients with a trileaflet aortic valve, without significant differences observed in any of the considered stiffness indices. CONCLUSIONS: TS and MFS teenage patients display evidence of increased aortic stiffness. In TS patients, this is focused in the ascending aorta and is independent of the presence of a BAV. MFS patients display a generalized reduction in compliance of the entire aorta.


Asunto(s)
Aorta/fisiopatología , Síndrome de Marfan/fisiopatología , Síndrome de Turner/fisiopatología , Rigidez Vascular/fisiología , Adolescente , Aorta/diagnóstico por imagen , Aorta/patología , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/patología , Aorta Torácica/fisiopatología , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Estudios de Casos y Controles , Niño , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Hemodinámica/fisiología , Humanos , Imagen por Resonancia Magnética , Masculino , Síndrome de Marfan/diagnóstico por imagen , Síndrome de Marfan/patología , Síndrome de Turner/diagnóstico por imagen , Síndrome de Turner/patología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...