Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 12(1): 3426, 2022 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-35236906

RESUMEN

Magnetic skyrmions are widely attracting researchers due to fascinating physics and novel applications related to their non-trivial topology. Néel skyrmions have been extensively investigated in magnetic systems with Dzyaloshinskii-Moriya interaction (DMI) and/or perpendicular magnetic anisotropy. Here, by means of micromagnetic simulations and analytical calculations, we show that 3D quasi-skyrmions of Néel type, with topological charge close to 1, can exist as metastable states in soft magnetic nanostructures with no DMI, such as in Permalloy thick cylindrical and dome-shaped nanodots. The key factor responsible for the stabilization of DMI-free is the interplay of the exchange and magnetostatic energies in the nanodots. The range of geometrical parameters where the skyrmions are found is wider in magnetic dome-shape nanodots than in their cylindrical counterparts. Our results open the door for a new research line related to the nucleation and stabilization of magnetic skyrmions in a broad class of nanostructured soft magnetic materials.

2.
Nanoscale ; 13(3): 2026-2033, 2021 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-33449980

RESUMEN

We demonstrate that a force microscope operated in a bimodal configuration enables the mapping of magnetic interactions with high quantitative accuracy and high-spatial resolution (∼30 nm). Bimodal AFM operation doubles the number of observables with respect to conventional magnetic force microscopy methods which enables to determine quantitatively in a single processing step several magnetic properties. The theory of bimodal AFM provides analytical expressions for different magnetic force models, in particular those characterized by power-law and exponential distance dependences. Bimodal AFM provides a self-evaluation protocol to test the accuracy of the measurements. The agreement obtained between the experiments and theory for two different magnetic samples support the application of bimodal AFM to map quantitatively long-range magnetic interactions.

3.
ACS Appl Mater Interfaces ; 12(33): 37750-37756, 2020 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-32705868

RESUMEN

Graphene is a very attractive material for nanomechanical devices and membrane applications. Graphene blisters based on silicon oxide microcavities are a simple but relevant example of nanoactuators. A drawback of this experimental setup is that gas leakage through the graphene-SiO2 interface contributes significantly to the total leak rate. Here, we study the diffusion of air from pressurized graphene drumheads on SiO2 microcavities and propose a straightforward method to improve the already strong adhesion between graphene and the underlying SiO2 substrate, resulting in reduced leak rates. This is carried out by applying controlled and localized ultrahigh pressure (>10 GPa) with an atomic force microscopy diamond tip. With this procedure, we are able to significantly approach the graphene layer to the SiO2 surface around the drumheads, thus enhancing the interaction between them, allowing us to better seal the graphene-SiO2 interface, which is reflected in up to ∼ 4 times lower leakage rates. Our work opens an easy way to improve the performance of graphene as a gas membrane on a technological relevant substrate such as SiO2.

4.
Nanoscale ; 12(36): 18646-18653, 2020 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-32584341

RESUMEN

Topologically non-trivial structures such as magnetic skyrmions are nanometric spin textures of outstanding potential for spintronic applications due to their unique features. It is well known that Néel skyrmions of definite chirality are stabilized by the Dzyaloshinskii-Moriya exchange interaction (DMI) in bulk non-centrosymmetric materials or ultrathin films with strong spin-orbit coupling at the interface. In this work, we show that soft magnetic (permalloy) hemispherical nanodots are able to host three-dimensional chiral structures (half-hedgehog spin textures) with non-zero tropological charge. They are observed at room temperature, in absence of DMI interaction and they can be further stabilized by the magnetic field arising from the Magnetic Force Microscopy probe. Micromagnetic simulations corroborate the experimental data. Our work implies the existence of a new degree of freedom to create and manipulate complex 3D spin-textures in soft magnetic nanodots and opens up future possibilities to explore their magnetization dynamics.

5.
Nanoscale ; 12(18): 10090-10097, 2020 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-32348391

RESUMEN

Focused Electron Beam Induced Deposition (FEBID) for magnetic tip fabrication is presented in this work as an alternative to conventional sputtering-based Magnetic Force Microscopy (MFM) tips. FEBID enables the growth of a high-aspect-ratio magnetic nanorod with customized geometry and composition to overcome the key technical limitations of MFM probes currently on the market. The biggest advantage of these tips, in comparison with CoCr coated pyramidal probes, lies in the capability of creating sharp ends, nearly 10 nm in diameter, which provides remarkable (topographic and magnetic) lateral resolution in samples with magnetic features close to the resolution limits of the MFM technique itself. The shape of the nanorods produces a very confined magnetic stray field, whose interaction with the sample is extremely localized and perpendicular to the surface, with negligible in-plane components. This effect can lead to a better analytical and numerical modelling of the MFM probes and to an increase in the sensitivity without perturbing the magnetic configuration of soft samples. Besides, the high-aspect ratio achievable in FEBID nanorod tips makes them magnetically harder than the commercial ones, reaching coercive fields higher than 900 Oe. According to the results shown, tips based on magnetic nanorods grown by FEBID can be eventually used for quantitative analysis in MFM measurements. Moreover, the customized growth of Co- or Fe-based tips onto levers with different mechanical properties allows MFM studies that demand different measuring conditions. To showcase the versatility of this type of probe, as a last step, MFM is performed in a liquid environment, which still remains a challenge for the MFM community largely due to the lack of appropriate probes on the market. This opens up new possibilities in the investigation of magnetic biological samples.

6.
ACS Nano ; 12(6): 5932-5939, 2018 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-29812903

RESUMEN

The unidirectional motion of information carriers such as domain walls in magnetic nanostrips is a key feature for many future spintronic applications based on shift registers. This magnetic ratchet effect has so far been achieved in a limited number of complex nanomagnetic structures, for example, by lithographically engineered pinning sites. Here we report on a simple remagnetization ratchet originated in the asymmetric potential from the designed increasing lengths of magnetostatically coupled ferromagnetic segments in FeCo/Cu cylindrical nanowires. The magnetization reversal in neighboring segments propagates sequentially in steps starting from the shorter segments, irrespective of the applied field direction. This natural and efficient ratchet offers alternatives for the design of three-dimensional advanced storage and logic devices.

7.
Nanomaterials (Basel) ; 8(4)2018 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-29642476

RESUMEN

In this article, the magnetic properties of hexagonally ordered antidot arrays made of Dy13Fe87 alloy are studied and compared with corresponding ones of continuous thin films with the same compositions and thicknesses, varying between 20 nm and 50 nm. Both samples, the continuous thin films and antidot arrays, were prepared by high vacuum e-beam evaporation of the alloy on the top-surface of glass and hexagonally self-ordered nanoporous alumina templates, which serve as substrates, respectively. By using a highly sensitive magneto-optical Kerr effect (MOKE) and vibrating sample magnetometer (VSM) measurements an interesting phenomenon has been observed, consisting in the easy magnetization axis transfer from a purely in-plane (INP) magnetic anisotropy to out-of-plane (OOP) magnetization. For the 30 nm film thickness we have measured the volume hysteresis loops by VSM with the easy magnetization axis lying along the OOP direction. Using magnetic force microscopy measurements (MFM), there is strong evidence to suggest that the formation of magnetic domains with OOP magnetization occurs in this sample. This phenomenon can be of high interest for the development of novel magnetic and magneto-optic perpendicular recording patterned media based on template-assisted deposition techniques.

8.
Nanoscale ; 8(38): 16989-16994, 2016 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-27722376

RESUMEN

Measuring energy dissipation on the nanoscale is of great interest not only for nanomechanics but also to understand important energy transformation and loss mechanisms that determine the efficiency of energy of data storage devices. Fully understanding the magnetic dynamics and dissipation processes in nanomagnets is of major relevance for a number of basic and applied issues from magnetic recording to spin-based sensor devices to biomedical magnetic-based hyperthermia treatments. Here we present experimental evidence for a counter-intuitive monotonical reduction of energy dissipation as the interaction between two nanomagnets is enhanced. This behavior, which takes place when spins are parallel, can be understood in terms of hysteresis phenomena involved in the reorientation of these spins. The measured magnetic losses of about a few femtowatts are in agreement with quasi-static micromagnetic numerical simulations.

9.
Beilstein J Nanotechnol ; 7: 1068-74, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27547625

RESUMEN

Magnetic force microscopy (MFM) is a widely used technique for magnetic imaging. Besides its advantages such as the high spatial resolution and the easy use in the characterization of relevant applied materials, the main handicaps of the technique are the lack of control over the tip stray field and poor lateral resolution when working under standard conditions. In this work, we present a convenient route to prepare high-performance MFM probes with sub-10 nm (sub-25 nm) topographic (magnetic) lateral resolution by following an easy and quick low-cost approach. This allows one to not only customize the tip stray field, avoiding tip-induced changes in the sample magnetization, but also to optimize MFM imaging in vacuum (or liquid media) by choosing tips mounted on hard (or soft) cantilevers, a technology that is currently not available on the market.

10.
Sci Rep ; 6: 29702, 2016 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-27406891

RESUMEN

The three dimensional nature of cylindrical magnetic nanowires has opened a new way to control the domain configuration as well as the magnetization reversal process. The pinning effect of the periodic diameter modulations on the domain wall propagation in FeCoCu individual nanowires is determined by Magnetic Force Microscopy, MFM. A main bistable magnetic configuration is firstly concluded from MFM images characterized by the spin reversal between two nearly single domain states with opposite axial magnetization. Complementary micromagnetic simulations confirm a vortex mediated magnetization reversal process. A non-standard variable field MFM imaging procedure allows us to observe metastable magnetic states where the propagating domain wall is pinned at certain positions with enlarged diameter. Moreover, it is demonstrated that it is possible to control the position of the pinned domain walls by an external magnetic field.

11.
Small ; 11(36): 4731-6, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26150330

RESUMEN

In this work, the use of magnetic force microscopy (MFM) to acquire images of magnetic nanostructures in liquid environments is presented. Optimization of the MFM signal acquisition in liquid media is performed and it is applied to characterize the magnetic signal of magnetite nanoparticles. The ability for detecting magnetic nanostructures along with the well-known capabilities of atomic force microscopy in liquids suggests potential applications in fields such as nanomedicine, nanobiotechnology, or nanocatalysis.


Asunto(s)
Magnetismo , Microscopía de Fuerza Atómica/métodos , Nanoestructuras/química , Nanotecnología/métodos , Aire , Animales , Medios de Contraste/química , Humanos , Nanopartículas de Magnetita/química , Nanomedicina/métodos , Tamaño de la Partícula , Succímero/química , Agua
12.
Chem Sci ; 6(3): 1949-1958, 2015 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-28706645

RESUMEN

A hybrid magnetic multilayer material of micrometric size, with highly crystalline hexagonal crystals consisting of CoAl-LDH ferromagnetic layers intercalated with thermoresponsive 4-(4-anilinophenylazo)benzenesulfonate (AO5) molecules diluted (ratio 9 : 1) with a flexible sodium dodecylsulphate (SDS) surfactant has been obtained. The resulting material exhibits thermochromism attributable to the isomerization between the azo (prevalent at room temperature) and the hydrazone (favoured at higher temperatures) tautomers, leading to a thermomechanical response. In fact, these crystals exhibited thermally induced motion triggering remarkable changes in the crystal morphology and volume. In situ variable temperature XRD of these thin hybrids shows that the reversible change into the two tautomers is reflected in a shift of the position of the diffraction peaks at high temperatures towards lower interlayer spacing for the hydrazone form, as well as a broadening of the peaks reflecting lower crystallinity and ordering due to non-uniform spacing between the layers. These structural variations between room temperature (basal spacing (BS) = 25.91 Å) and 100 °C (BS = 25.05 Å) are also reflected in the magnetic properties of the layered double hydroxide (LDH) due to the variation of the magnetic coupling between the layers. Overall, our study constitutes one of the few examples showing fully reversible thermo-responsive breathing in a 2D hybrid material. In addition, the magnetic response of the hybrid can be modulated due to the thermotropism of the organic component that, by influencing the distance and in-plane correlation of the inorganic LDH, modulates the magnetism of the CoAl-LDH sheets in a certain range.

13.
Beilstein J Nanotechnol ; 4: 153-63, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23503468

RESUMEN

The recent achievement of atomic resolution with dynamic atomic force microscopy (dAFM) [Fukuma et al., Appl. Phys. Lett. 2005, 87, 034101], where quality factors of the oscillating probe are inherently low, challenges some accepted beliefs concerning sensitivity and resolution in dAFM imaging modes. Through analysis and experiment we study the performance metrics for high-resolution imaging with dAFM in liquid media with amplitude modulation (AM), frequency modulation (FM) and drive-amplitude modulation (DAM) imaging modes. We find that while the quality factors of dAFM probes may deviate by several orders of magnitude between vacuum and liquid media, their sensitivity to tip-sample forces can be remarkable similar. Furthermore, the reduction in noncontact forces and quality factors in liquids diminishes the role of feedback control in achieving high-resolution images. The theoretical findings are supported by atomic-resolution images of mica in water acquired with AM, FM and DAM under similar operating conditions.

14.
Beilstein J Nanotechnol ; 3: 336-44, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22563531

RESUMEN

We introduce drive-amplitude-modulation atomic force microscopy as a dynamic mode with outstanding performance in all environments from vacuum to liquids. As with frequency modulation, the new mode follows a feedback scheme with two nested loops: The first keeps the cantilever oscillation amplitude constant by regulating the driving force, and the second uses the driving force as the feedback variable for topography. Additionally, a phase-locked loop can be used as a parallel feedback allowing separation of the conservative and nonconservative interactions. We describe the basis of this mode and present some examples of its performance in three different environments. Drive-amplutide modulation is a very stable, intuitive and easy to use mode that is free of the feedback instability associated with the noncontact-to-contact transition that occurs in the frequency-modulation mode.

15.
Beilstein J Nanotechnol ; 2: 552-60, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22003461

RESUMEN

The most outstanding feature of scanning force microscopy (SFM) is its capability to detect various different short and long range interactions. In particular, magnetic force microscopy (MFM) is used to characterize the domain configuration in ferromagnetic materials such as thin films grown by physical techniques or ferromagnetic nanostructures. It is a usual procedure to separate the topography and the magnetic signal by scanning at a lift distance of 25-50 nm such that the long range tip-sample interactions dominate. Nowadays, MFM is becoming a valuable technique to detect weak magnetic fields arising from low dimensional complex systems such as organic nanomagnets, superparamagnetic nanoparticles, carbon-based materials, etc. In all these cases, the magnetic nanocomponents and the substrate supporting them present quite different electronic behavior, i.e., they exhibit large surface potential differences causing heterogeneous electrostatic interaction between the tip and the sample that could be interpreted as a magnetic interaction. To distinguish clearly the origin of the tip-sample forces we propose to use a combination of Kelvin probe force microscopy (KPFM) and MFM. The KPFM technique allows us to compensate in real time the electrostatic forces between the tip and the sample by minimizing the electrostatic contribution to the frequency shift signal. This is a great challenge in samples with low magnetic moment. In this work we studied an array of Co nanostructures that exhibit high electrostatic interaction with the MFM tip. Thanks to the use of the KPFM/MFM system we were able to separate the electric and magnetic interactions between the tip and the sample.

16.
Nanoscale Res Lett ; 6(1): 407, 2011 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-21711935

RESUMEN

High-resolution magnetic imaging is of utmost importance to understand magnetism at the nanoscale. In the present work, we use a magnetic force microscope (MFM) operating under in-plane magnetic field in order to observe with high accuracy the domain configuration changes in Co nanowires as a function of the externally applied magnetic field. The main result is the quantitative evaluation of the coercive field of the individual nanostructures. Such characterization is performed by using an MFM-based technique in which a map of the magnetic signal is obtained as a function of both the lateral displacement and the magnetic field.

17.
Phys Rev Lett ; 105(25): 257203, 2010 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-21231621

RESUMEN

In this work we investigate possible ferromagnetic order on the graphite surface by using magnetic force microscopy (MFM). Our data show that the tip-sample interaction along the steps is independent of an external magnetic field. Moreover, by combining kelvin probe force microscopy and MFM, we are able to separate the electrostatic and magnetic interactions along the steps obtaining an upper bound for the magnetic force gradient of 16 µN/m. Our experiments suggest the absence of ferromagnetic signal in graphite at room temperature.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...