Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Placenta ; 144: 29-37, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37952367

RESUMEN

INTRODUCTION: In-vivo measurements of placental structure and function have the potential to improve prediction, diagnosis, and treatment planning for a wide range of pregnancy complications, such as fetal growth restriction and pre-eclampsia, and hence inform clinical decision making, ultimately improving patient outcomes. MRI is emerging as a technique with increased sensitivity to placental structure and function compared to the current clinical standard, ultrasound. METHODS: We demonstrate and evaluate a combined diffusion-relaxation MRI acquisition and analysis pipeline on a sizable cohort of 78 normal pregnancies with gestational ages ranging from 15 + 5 to 38 + 4 weeks. Our acquisition comprises a combined T2*-diffusion MRI acquisition sequence - which is simultaneously sensitive to oxygenation, microstructure and microcirculation. We analyse our scans with a data-driven unsupervised machine learning technique, InSpect, that parsimoniously identifies distinct components in the data. RESULTS: We identify and map seven potential placental microenvironments and reveal detailed insights into multiple microstructural and microcirculatory features of the placenta, and assess their trends across gestation. DISCUSSION: By demonstrating direct observation of micro-scale placental structure and function, and revealing clear trends across pregnancy, our work contributes towards the development of robust imaging biomarkers for pregnancy complications and the ultimate goal of a normative model of placental development.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Placenta , Embarazo , Humanos , Femenino , Placenta/diagnóstico por imagen , Microcirculación , Retardo del Crecimiento Fetal , Imagen por Resonancia Magnética/métodos , Placentación
2.
Acta Obstet Gynecol Scand ; 100(12): 2244-2252, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34546571

RESUMEN

INTRODUCTION: Preterm prelabor rupture of membranes (PPROM) complicates 3% of pregnancies in the UK. Where delivery does not occur spontaneously, expectant management until 37 weeks of gestation is advocated, unless signs of maternal infection develop. However, clinical presentation of maternal infection can be a late sign and injurious fetal inflammatory responses may already have been activated. There is therefore a need for more sensitive markers to aid optimal timing of interventions. At present there is no non-invasive test in clinical practice to assess for infection in the fetal compartment and definitive diagnosis of chorioamnionitis is by histological assessment of the placenta after delivery. This study presents comprehensive functional placental magnetic resonance imaging (MRI) quantification, already used in other organ systems, to assess for infection/inflammation, in women with and without PPROM aiming to explore its use as a biomarker for inflammation within the feto-placental compartment in vivo. MATERIAL AND METHODS: Placental MRI scans were performed in a cohort of 12 women (with one having two scans) with PPROM before 34 weeks of gestation (selected because of their high risk of infection), and in a control group of 87 women. Functional placental assessment was performed with magnetic resonance techniques sensitive to changes in the microstructure (diffusion) and tissue composition (relaxometry), with quantification performed both over the entire organ and in regions of interest between the basal and chorionic plate. Placental histology was analyzed after delivery where available. RESULTS: Normative evolution of functional magnetic resonance biomarkers over gestation was studied. Cases of inflammation, as assessed by histological presence of chorioamnionitis, and umbilical cord vasculitis with or without funisitis, were associated with lower T2* (mean T2* at 30 weeks 50 ms compared with 58 ms in controls) and higher fractional anisotropy (mean at 30 weeks 0.55 compared with 0.45 in controls). These differences did not reach significance and there was substantial heterogeneity both in T2* and Apparent Diffusivitiy across the cohort. CONCLUSIONS: This first exploration of functional placental assessment in a cohort of women with PPROM demonstrates that functional placental MRI can reveal a range of placental changes associated with inflammatory processes. It is a promising tool to gain information and in the future to identify inflammation in vivo, and could therefore assist in improving optimal timing for interventions designed to prevent fetal injury.


Asunto(s)
Rotura Prematura de Membranas Fetales/diagnóstico por imagen , Diagnóstico Prenatal , Adulto , Femenino , Humanos , Londres , Imagen por Resonancia Magnética , Proyectos Piloto , Embarazo , Estudios Prospectivos , Centros de Atención Terciaria
3.
Magn Reson Med ; 86(5): 2684-2691, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34268807

RESUMEN

PURPOSE: To provide a new approach to jointly assess microstructural and molecular properties of the human placenta in vivo fast and efficiently and to present initial evidence in cohorts of healthy pregnancies and those affected by pre-eclampsia. METHODS: Slice and diffusion preparation shuffling, built on the previously proposed ZEBRA method, is presented as a robust and fast way to obtain T1 and apparent diffusivity coefficient (ADC) values. Joint modeling and evaluation is performed on a cohort of healthy and pre-eclamptic participants at 3T. RESULTS: The datasets show the ability to obtain robust and fast T1 -ADC measurements. Significant decay over gestation in T1 (-11 ms/week, P<.05 ) and a trend toward significance in ADC (-0.23 mm/ s2 /week, P = .08) values can be observed in a control cohort. Values for the pre-eclamptic pregnancies show a negative trend for both ADC and T1 . CONCLUSIONS: The presented sequence allows the simultaneous acquisition of 2 of the most promising quantitative parameters to study placental insufficiency-identified individually as relevant in previous studies-in under 2 minutes. This allows dynamic assessment of physiological processes, reduced inconsistency in spatial comparisons due to reduced motion artefacts and opens novel avenues for analysis. Initial results in pre-eclamptic placentas, with depicted changes in both ADC and T1 , illustrate its potential to identify cases of placental insufficiency. Future work will focus on expanding the field-of-view using multi-band acceleration techniques and the expansion to larger and more diverse patient groups.


Asunto(s)
Placenta , Preeclampsia , Difusión , Imagen de Difusión por Resonancia Magnética , Femenino , Humanos , Placenta/diagnóstico por imagen , Preeclampsia/diagnóstico por imagen , Embarazo
4.
Adv Sci (Weinh) ; 8(11): e2003987, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34105284

RESUMEN

Early measurements of tissue viability after myocardial infarction (MI) are essential for accurate diagnosis and treatment planning but are challenging to obtain. Here, manganese, a calcium analogue and clinically approved magnetic resonance imaging (MRI) contrast agent, is used as an imaging biomarker of myocardial viability in the first hours after experimental MI. Safe Mn2+ dosing is confirmed by measuring in vitro beating rates, calcium transients, and action potentials in cardiomyocytes, and in vivo heart rates and cardiac contractility in mice. Quantitative T1 mapping-manganese-enhanced MRI (MEMRI) reveals elevated and increasing Mn2+ uptake in viable myocardium remote from the infarct, suggesting MEMRI offers a quantitative biomarker of cardiac inotropy. MEMRI evaluation of infarct size at 1 h, 1 and 14 days after MI quantifies myocardial viability earlier than the current gold-standard technique, late-gadolinium-enhanced MRI. These data, coupled with the re-emergence of clinical Mn2+ -based contrast agents open the possibility of using MEMRI for direct evaluation of myocardial viability early after ischemic onset in patients.


Asunto(s)
Supervivencia Celular/efectos de los fármacos , Medios de Contraste/farmacología , Corazón/diagnóstico por imagen , Manganeso/farmacología , Infarto del Miocardio/diagnóstico , Animales , Gluconato de Calcio/farmacología , Modelos Animales de Enfermedad , Corazón/fisiopatología , Humanos , Imagen por Resonancia Magnética , Ratones , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/patología , Miocardio/patología , Miocitos Cardíacos/efectos de los fármacos , Miocitos Cardíacos/patología
5.
Med Image Anal ; 71: 102045, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33934005

RESUMEN

We introduce and demonstrate an unsupervised machine learning technique for spectroscopic analysis of quantitative MRI experiments. Our algorithm supports estimation of one-dimensional spectra from single-contrast data, and multidimensional correlation spectra from simultaneous multi-contrast data. These spectrum-based approaches allow model-free investigation of tissue properties, but require regularised inversion of a Laplace transform or Fredholm integral, which is an ill-posed calculation. Here we present a method that addresses this limitation in a data-driven way. The algorithm simultaneously estimates a canonical basis of spectral components and voxelwise maps of their weightings, thereby pooling information across whole images to regularise the ill-posed problem. We show in simulations that our algorithm substantially outperforms current voxelwise spectral approaches. We demonstrate the method on multi-contrast diffusion-relaxometry placental MRI scans, revealing anatomically-relevant sub-structures, and identifying dysfunctional placentas. Our algorithm vastly reduces the data required to reliably estimate spectra, opening up the possibility of quantitative MRI spectroscopy in a wide range of new applications. Our InSpect code is available at github.com/paddyslator/inspect.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Placenta , Algoritmos , Femenino , Humanos , Imagen por Resonancia Magnética , Embarazo
6.
Placenta ; 104: 138-145, 2021 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-33341490

RESUMEN

INTRODUCTION: We aimed to explore the use of magnetic resonance imaging (MRI) in vivo as a tool to elucidate the placental phenotype in women with chronic hypertension. METHODS: In case-control study, women with chronic hypertension and those with uncomplicated pregnancies were imaged using either a 3T Achieva or 1.5T Ingenia scanner. T2-weighted images, diffusion weighted and T1/T2* relaxometry data was acquired. Placental T2*, T1 and apparent diffusion coefficient (ADC) maps were calculated. RESULTS: 129 women (43 with chronic hypertension and 86 uncomplicated pregnancies) were imaged at a median of 27.7 weeks' gestation (interquartile range (IQR) 23.9-32.1) and 28.9 (IQR 26.1-32.9) respectively. Visual analysis of T2-weighted imaging demonstrated placentae to be either appropriate for gestation or to have advanced lobulation in women with chronic hypertension, resulting in a greater range of placental mean T2* values for a given gestation, compared to gestation-matched controls. Both skew and kurtosis (derived from histograms of T2* values across the whole placenta) increased with advancing gestational age at imaging in healthy pregnancies; women with chronic hypertension had values overlapping those in the control group range. Upon visual assessment, the mean ADC declined in the third trimester, with a corresponding decline in placental mean T2* values and showed an overlap of values between women with chronic hypertension and the control group. DISCUSSION: A combined placental MR examination including T2 weighted imaging, T2*, T1 mapping and diffusion imaging demonstrates varying placental phenotypes in a cohort of women with chronic hypertension, showing overlap with the control group.


Asunto(s)
Hipertensión/diagnóstico por imagen , Imagen por Resonancia Magnética , Placenta/diagnóstico por imagen , Adulto , Estudios de Casos y Controles , Femenino , Edad Gestacional , Humanos , Embarazo , Ultrasonografía Prenatal
8.
Nat Commun ; 11(1): 4992, 2020 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-33020487

RESUMEN

Prenatal detection of congenital heart disease facilitates the opportunity for potentially life-saving care immediately after the baby is born. Echocardiography is routinely used for screening of morphological malformations, but functional measurements of blood flow are scarcely used in fetal echocardiography due to technical assumptions and issues of reliability. Magnetic resonance imaging (MRI) is readily used for quantification of abnormal blood flow in adult hearts, however, existing in utero approaches are compromised by spontaneous fetal motion. Here, we present and validate a novel method of MRI velocity-encoding combined with a motion-robust reconstruction framework for four-dimensional visualization and quantification of blood flow in the human fetal heart and major vessels. We demonstrate simultaneous 4D visualization of the anatomy and circulation, which we use to quantify flow rates through various major vessels. The framework introduced here could enable new clinical opportunities for assessment of the fetal cardiovascular system in both health and disease.


Asunto(s)
Corazón Fetal/diagnóstico por imagen , Corazón Fetal/fisiología , Tomografía Computarizada Cuatridimensional/métodos , Imagen por Resonancia Cinemagnética/métodos , Velocidad del Flujo Sanguíneo , Vasos Sanguíneos/diagnóstico por imagen , Vasos Sanguíneos/fisiología , Femenino , Edad Gestacional , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/fisiopatología , Humanos , Fantasmas de Imagen , Embarazo , Diagnóstico Prenatal
9.
Hypertension ; 75(6): 1523-1531, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32336233

RESUMEN

Placental dysfunction underlies the cause of pregnancies complicated by preeclampsia. The use of placental magnetic resonance imaging to provide an insight into the pathophysiology of preeclampsia and thus assess its potential use to inform prognosis and clinical management was explored. In this prospective observational cohort study, 14 women with preterm preeclampsia and 48 gestation-matched controls using 3-Tesla magnetic resonance imaging at median of 31.6 weeks (interquartile range [IQR], 28.6-34.6) and 32.2 weeks (IQR, 28.6-33.8), respectively, were imaged. The acquired data included T2-weighted images and T2* maps of the placenta, the latter an indicative measure of placental oxygenation. Placentae in women with preeclampsia demonstrated advanced lobulation, varied lobule sizes, high granularity, and substantial areas of low-signal intensity on T2-weighted imaging, with reduced entire placental mean T2* values for gestational age (2 sample t test, t=7.49) correlating with a reduction in maternal PlGF (placental growth factor) concentrations (Spearman rank correlation coefficient 0.76) and increased lacunarity values (t=3.26). Median mean T2* reduced from 67 ms (IQR, 54-73) at 26.0 to 29.8 weeks' gestation to 38 ms (IQR, 28-40) at 34.0 to 37.9 weeks' gestation in the control group. In women with preeclampsia, median T2* was 23 ms (IQR, 20-23) at 26.0 to 29.8 weeks' gestation and remained low (22 ms [IQR, 20-26] at 34.0-37.8 weeks' gestation). Histological features of maternal vascular malperfusion were only found in placentae from women with preeclampsia. Placental volume did not differ between the control group and women with preeclampsia. Placental magnetic resonance imaging allows both objective quantification of placental function in vivo and elucidation of the complex mechanisms underlying preeclampsia development.


Asunto(s)
Placenta , Insuficiencia Placentaria , Preeclampsia , Adulto , Estudios de Cohortes , Femenino , Edad Gestacional , Humanos , Angiografía por Resonancia Magnética/métodos , Tamaño de los Órganos , Consumo de Oxígeno , Placenta/diagnóstico por imagen , Placenta/metabolismo , Placenta/patología , Placenta/fisiopatología , Factor de Crecimiento Placentario/sangre , Pruebas de Función Placentaria , Insuficiencia Placentaria/diagnóstico , Insuficiencia Placentaria/metabolismo , Insuficiencia Placentaria/fisiopatología , Preeclampsia/diagnóstico , Preeclampsia/fisiopatología , Preeclampsia/terapia , Embarazo , Trimestres del Embarazo , Reproducibilidad de los Resultados , Reino Unido
10.
Magn Reson Med ; 84(4): 1828-1843, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32141655

RESUMEN

PURPOSE: Placental function is key for successful human pregnancies. Perfusion may be a sensitive marker for the in vivo assessment of placental function. Arterial spin labeling (ASL) MRI enables noninvasive measurement of tissue perfusion and it was recently suggested that ASL with velocity-selective (VS) labeling could be advantageous in the placenta. We systematically evaluated essential VS-ASL sequence parameters to determine optimal settings for efficient placental perfusion measurements. METHODS: Eleven pregnant women were scanned at 3T using VS-ASL with 2D multislice echo planar imaging (EPI)-readout. One reference VS-ASL scan was acquired in all subjects; within subgroups the following parameters were systematically varied: cutoff velocity, velocity encoding direction, and inflow time. Visual evaluation and region of interest analyses were performed to compare perfusion signal differences between acquisitions. RESULTS: In all subjects, a perfusion pattern with clear hyperintense focal regions was observed. Perfusion signal decreased with inflow time and cutoff velocity. Subject-specific dependence on velocity encoding direction was observed. High temporal signal-to-noise ratios with high contrast on the perfusion images between the hyperintense regions and placental tissue were seen at ~1.6 cm/s cutoff velocity and ~1000 ms inflow time. Evaluation of measurements at multiple inflow times revealed differences in blood flow dynamics between placental regions. CONCLUSION: Placental perfusion measurements are feasible at 3T using VS-ASL with 2D multislice EPI-readout. A clear dependence of perfusion signal on VS labeling parameters and inflow time was demonstrated. Whereas multiple parameter combinations may advance the interpretation of placental circulation dynamics, this study provides a basis to select an effective set of parameters for the observation of placenta perfusion natural history and its potential pathological changes.


Asunto(s)
Arterias , Imagen por Resonancia Magnética , Circulación Cerebrovascular , Femenino , Humanos , Angiografía por Resonancia Magnética , Perfusión , Placenta/diagnóstico por imagen , Embarazo , Marcadores de Spin
11.
IEEE Trans Med Imaging ; 39(9): 2750-2759, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32086200

RESUMEN

In in-utero MRI, motion correction for fetal body and placenta poses a particular challenge due to the presence of local non-rigid transformations of organs caused by bending and stretching. The existing slice-to-volume registration (SVR) reconstruction methods are widely employed for motion correction of fetal brain that undergoes only rigid transformation. However, for reconstruction of fetal body and placenta, rigid registration cannot resolve the issue of misregistrations due to deformable motion, resulting in degradation of features in the reconstructed volume. We propose a Deformable SVR (DSVR), a novel approach for non-rigid motion correction of fetal MRI based on a hierarchical deformable SVR scheme to allow high resolution reconstruction of the fetal body and placenta. Additionally, a robust scheme for structure-based rejection of outliers minimises the impact of registration errors. The improved performance of DSVR in comparison to SVR and patch-to-volume registration (PVR) methods is quantitatively demonstrated in simulated experiments and 20 fetal MRI datasets from 28-31 weeks gestational age (GA) range with varying degree of motion corruption. In addition, we present qualitative evaluation of 100 fetal body cases from 20-34 weeks GA range.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Algoritmos , Femenino , Feto/diagnóstico por imagen , Humanos , Movimiento (Física) , Placenta/diagnóstico por imagen , Embarazo
12.
Magn Reson Med ; 83(2): 549-560, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31433077

RESUMEN

PURPOSE: To study placental function-both perfusion and an oxygenation surrogate ( T2* )-simultaneously and quantitatively in-vivo. METHODS: Fifteen pregnant women were scanned on a 3T MR scanner. For perfusion measurements, a velocity selective arterial spin labeling preparation module was placed before a multi-echo gradient echo EPI readout to integrate T2* and perfusion measurements in 1 joint perfusion-oxygenation (PERFOX) acquisition. Joint motion correction and quantification were performed to evaluate changes in T2* and perfusion over GA. RESULTS: The optimized integrated PERFOX protocol and post-processing allowed successful visualization and quantification of perfusion and T2* in all subjects. Areas of high T2* and high perfusion appear to correspond to placental sub-units and show a systematic offset in location along the maternal-fetal axis. The areas of highest perfusion are consistently closer to the maternal basal plate and the areas of highest T2* closer to the fetal chorionic plate. Quantitative results show a strong negative correlation of gestational age with T2* and weak negative correlation with perfusion. CONCLUSIONS: A strength of the joint sequence is that it provides truly simultaneous and co-registered estimates of local T2* and perfusion, however, to achieve this, the time per slice is prolonged compared to a perfusion only scan which can potentially limit coverage. The achieved interlocking can be particularly useful when quantifying transient physiological effects such as uterine contractions. PERFOX opens a new avenue to elucidate the relationship between maternal supply and oxygen uptake, both of which are central to placental function and dysfunction.


Asunto(s)
Imagen Eco-Planar , Imagen por Resonancia Magnética , Oxígeno/metabolismo , Placenta/fisiología , Algoritmos , Circulación Sanguínea , Medios de Contraste , Femenino , Análisis de Fourier , Edad Gestacional , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador , Angiografía por Resonancia Magnética , Movimiento (Física) , Perfusión , Embarazo , Marcadores de Spin
14.
Sci Rep ; 9(1): 11592, 2019 08 12.
Artículo en Inglés | MEDLINE | ID: mdl-31406195

RESUMEN

In utero gene therapy (IUGT) to the fetal hematopoietic compartment could be used to treat congenital blood disorders such as ß-thalassemia. A humanised mouse model of ß-thalassemia was used, in which heterozygous animals are anaemic with splenomegaly and extramedullary hematopoiesis. Intrahepatic in utero injections of a ß globin-expressing lentiviral vector (GLOBE), were performed in fetuses at E13.5 of gestation. We analysed animals at 12 and 32 weeks of age, for vector copy number in bone marrow, peripheral blood liver and spleen and we performed integration site analysis. Compared to noninjected heterozygous animals IUGT normalised blood haemoglobin levels and spleen weight. Integration site analysis showed polyclonality. The left ventricular ejection fraction measured using magnetic resonance imaging (MRI) in treated heterozygous animals was similar to that of normal non-ß-thalassemic mice but significantly higher than untreated heterozygous thalassemia mice suggesting that IUGT ameliorated poor cardiac function. GLOBE LV-mediated IUGT normalised the haematological and anatomical phenotype in a heterozygous humanised model of ß-thalassemia.


Asunto(s)
Terapia Genética , Heterocigoto , Imagen por Resonancia Magnética/métodos , Animales , Femenino , Humanos , Ratones , Fenotipo , Embarazo , Talasemia beta/genética
15.
Magn Reson Med ; 82(1): 95-106, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30883915

RESUMEN

PURPOSE: A combined diffusion-relaxometry MR acquisition and analysis pipeline for in vivo human placenta, which allows for exploration of coupling between T2* and apparent diffusion coefficient (ADC) measurements in a sub 10-minute scan time. METHODS: We present a novel acquisition combining a diffusion prepared spin echo with subsequent gradient echoes. The placentas of 17 pregnant women were scanned in vivo, including both healthy controls and participants with various pregnancy complications. We estimate the joint T2* -ADC spectra using an inverse Laplace transform. RESULTS: T2* -ADC spectra demonstrate clear quantitative separation between normal and dysfunctional placentas. CONCLUSIONS: Combined T2* -diffusivity MRI is promising for assessing fetal and maternal health during pregnancy. The T2* -ADC spectrum potentially provides additional information on tissue microstructure, compared to measuring these two contrasts separately. The presented method is immediately applicable to the study of other organs.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Enfermedades Placentarias/diagnóstico por imagen , Placenta/diagnóstico por imagen , Procesamiento de Señales Asistido por Computador , Femenino , Retardo del Crecimiento Fetal/diagnóstico por imagen , Humanos , Preeclampsia/diagnóstico por imagen , Embarazo
16.
Magn Reson Med ; 81(2): 1191-1204, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30242899

RESUMEN

PURPOSE: To investigate, visualize and quantify the physiology of the human placenta in several dimensions - functional, temporal over gestation, and spatial over the whole organ. METHODS: Bespoke MRI techniques, combining a rich diffusion protocol, anatomical data and T2* mapping together with a multi-modal pipeline including motion correction and extracted quantitative features were developed and employed on pregnant women between 22 and 38 weeks gestational age including two pregnancies diagnosed with pre-eclampsia. RESULTS: A multi-faceted assessment was demonstrated showing trends of increasing lacunarity, and decreasing T2* and diffusivity over gestation. CONCLUSIONS: The obtained multi-modal acquisition and quantification shows promising opportunities for studying evolution, adaptation and compensation processes.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Procesamiento de Imagen Asistido por Computador/métodos , Placenta/diagnóstico por imagen , Preeclampsia/diagnóstico por imagen , Diagnóstico Prenatal/métodos , Algoritmos , Anisotropía , Artefactos , Femenino , Feto , Edad Gestacional , Humanos , Análisis de los Mínimos Cuadrados , Modelos Anatómicos , Movimiento (Física) , Embarazo
17.
Sci Rep ; 8(1): 15138, 2018 10 11.
Artículo en Inglés | MEDLINE | ID: mdl-30310108

RESUMEN

The emergence of multiparametric diffusion models combining diffusion and relaxometry measurements provides powerful new ways to explore tissue microstructure, with the potential to provide new insights into tissue structure and function. However, their ability to provide rich analyses and the potential for clinical translation critically depends on the availability of efficient, integrated, multi-dimensional acquisitions. We propose a fully integrated sequence simultaneously sampling the acquisition parameter spaces required for T1 and T2* relaxometry and diffusion MRI. Slice-level interleaved diffusion encoding, multiple spin/gradient echoes and slice-shuffling are combined for higher efficiency, sampling flexibility and enhanced internal consistency. In-vivo data was successfully acquired on healthy adult brains. Obtained parametric maps as well as clustering results demonstrate the potential of the technique to provide eloquent data with an acceleration of roughly 20 compared to conventionally used approaches. The proposed integrated acquisition, which we call ZEBRA, offers significant acceleration and flexibility compared to existing diffusion-relaxometry studies, and thus facilitates wider use of these techniques both for research-driven and clinical applications.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Difusión , Interpretación de Imagen Asistida por Computador , Modelos Teóricos , Procesamiento de Señales Asistido por Computador , Algoritmos , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Imagen de Difusión por Resonancia Magnética/métodos , Humanos
18.
Circ Cardiovasc Imaging ; 11(10): e007753, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30354476

RESUMEN

BACKGROUND: In the era of increasingly successful corrective interventions in patients with congenital heart disease (CHD), global and regional myocardial remodeling are emerging as important sources of long-term morbidity/mortality. Changes in organization of the myocardium in CHD, and in its mechanical properties, conduction, and blood supply, result in altered myocardial function both before and after surgery. To gain a better understanding and develop appropriate and individualized treatment strategies, the microscopic organization of cardiomyocytes, and their integration at a macroscopic level, needs to be completely understood. The aim of this study is to describe, for the first time, in 3 dimensions and nondestructively the detailed remodeling of cardiac microstructure present in a human fetal heart with complex CHD. METHODS AND RESULTS: Synchrotron X-ray phase-contrast imaging was used to image an archival midgestation formalin-fixed fetal heart with right isomerism and complex CHD and compare with a control fetal heart. Analysis of myocyte aggregates, at detail not accessible with other techniques, was performed. Macroanatomic and conduction system changes specific to the disease were clearly observable, together with disordered myocyte organization in the morphologically right ventricle myocardium. Electrical activation simulations suggested altered synchronicity of the morphologically right ventricle. CONCLUSIONS: We have shown the potential of X-ray phase-contrast imaging for studying cardiac microstructure in the developing human fetal heart at high resolution providing novel insight while preserving valuable archival material for future study. This is the first study to show myocardial alterations occur in complex CHD as early as midgestation.


Asunto(s)
Corazón Fetal/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico , Miocitos Cardíacos/patología , Diagnóstico Prenatal/métodos , Femenino , Corazón Fetal/fisiopatología , Cardiopatías Congénitas/embriología , Cardiopatías Congénitas/fisiopatología , Humanos , Imagen por Resonancia Cinemagnética , Embarazo , Segundo Trimestre del Embarazo , Tomografía Computarizada por Rayos X
19.
NMR Biomed ; 30(10)2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28643891

RESUMEN

Diastolic dysfunction is a sensitive early indicator of heart failure and can provide additional data to conventional measures of systolic function. Transmitral Doppler ultrasound, which measures the one-dimensional flow of blood through the mitral valve, is currently the preferred method for the measurement of diastolic function, but the measurement of the left ventricular volume changes using high-temporal-resolution cinematic magnetic resonance imaging (CINE MRI) is an alternative approach which is emerging as a potentially more robust and user-independent technique. Here, we investigated the performance of high-temporal-resolution CINE MRI and compared it with ultrasound for the detection of diastolic dysfunction in a mouse model of myocardial infarction. An in-house, high-temporal-resolution, retrospectively gated CINE sequence was developed with a temporal resolution of 1 ms. Diastolic function in mice was assessed using a custom-made, open-source reconstruction package. Early (E) and late (A) left ventricular filling phases were easily identifiable, and these measurements were compared directly with high-frequency, pulsed-wave, Doppler ultrasound measurements of mitral valve inflow. A repeatability study established that high-temporal-resolution CINE MRI and Doppler ultrasound showed comparable accuracy when measuring E/A in normal control mice. However, when applied in a mouse model of myocardial infarction, high-temporal-resolution CINE MRI indicated diastolic heart failure (E/A = 0.94 ± 0.11), whereas ultrasound falsely detected normal cardiac function (E/A = 1.21 ± 0.11). The addition of high-temporal-resolution CINE MRI to preclinical imaging studies enhances the library of sequences available to cardiac researchers and potentially identifies diastolic heart failure early in disease progression.


Asunto(s)
Diástole/fisiología , Imagen por Resonancia Cinemagnética/métodos , Ultrasonografía Doppler , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/fisiopatología , Animales , Procesamiento de Imagen Asistido por Computador , Ratones , Infarto del Miocardio/fisiopatología , Reproducibilidad de los Resultados , Sístole/fisiología , Factores de Tiempo , Disfunción Ventricular Izquierda/diagnóstico por imagen
20.
ACS Cent Sci ; 3(4): 338-348, 2017 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-28470052

RESUMEN

Retention and survival of transplanted cells are major limitations to the efficacy of regenerative medicine, with short-term paracrine signals being the principal mechanism underlying current cell therapies for heart repair. Consequently, even improvements in short-term durability may have a potential impact on cardiac cell grafting. We have developed a multimodal hydrogel-based platform comprised of a poly(ethylene glycol) network cross-linked with bioactive peptides functionalized with Gd(III) in order to monitor the localization and retention of the hydrogel in vivo by magnetic resonance imaging. In this study, we have tailored the material for cardiac applications through the inclusion of a heparin-binding peptide (HBP) sequence in the cross-linker design and formulated the gel to display mechanical properties resembling those of cardiac tissue. Luciferase-expressing cardiac stem cells (CSC-Luc2) encapsulated within these gels maintained their metabolic activity for up to 14 days in vitro. Encapsulation in the HBP hydrogels improved CSC-Luc2 retention in the mouse myocardium and hind limbs at 3 days by 6.5- and 12- fold, respectively. Thus, this novel heparin-binding based, Gd(III)-tagged hydrogel and CSC-Luc2 platform system demonstrates a tailored, in vivo detectable theranostic cell delivery system that can be implemented to monitor and assess the transplanted material and cell retention.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...