Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
2.
Diagn Interv Imaging ; 98(12): 827-835, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29157897

RESUMEN

OBJECTIVES: The purpose of this study was to investigate the incidence of and the risk factors for arteriopathy in hepatic arteries after transarterial chemo-lipiodolization in patients with hepatocellular carcinoma and the subsequent treatment strategy changes due to arteriopathy. PATIENTS AND METHODS: A total of 365 arteries in 167 patients (126 men and 41 women; mean age, 60.4±15.0 [SD] years [range: 18-87 years]) were evaluated for the development of arteriopathy after chemo-lipiodolization with epirubicin- or doxorubicin-Lipiodol® emulsion. The development of arteriopathy after chemo-lipiodolization was assessed on arteriograms performed during subsequent transarterial treatments. The treatment strategy changes due to arteriopathy, including change in the chemo-lipiodolization method and the application of alternative therapies was also investigated. Univariate and multivariate binary logistic regression models were used to identify risk factors for arteriopathy and subsequent treatment strategy change. RESULTS: One hundred two (27.9%) arteriopathies were detected in 62/167 (37.1%) patients (45 men, 17 women) with a mean age of 63.3±7.1 [SD] years (age range, 50-86 years). The incidence of arteriopathy was highly patient dependent, demonstrating significant correlation in a fully-adjusted multivariate regression model (P<0.0001). Multivariate-adjusted regression analysis with adjustment for the patient effect showed a statistically significant association of super-selective chemo-lipiodolization (P=0.003) with the incidence of arteriopathy. Thirty of the 102 arteriopathies (29.4%) caused a change in treatment strategy. No factors were found to be significantly associated with the treatment strategy change. CONCLUSION: The incidence of arteriopathy after chemo-lipiodolization is 27.9%. Among them, 29.4% result in a change in treatment strategy.


Asunto(s)
Antineoplásicos/administración & dosificación , Arteriopatías Oclusivas/epidemiología , Arteriopatías Oclusivas/etiología , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/efectos adversos , Aceite Etiodizado/administración & dosificación , Arteria Hepática , Neoplasias Hepáticas/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Adulto Joven
3.
Diagn Interv Imaging ; 98(7-8): 543-549, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28219606

RESUMEN

OBJECTIVE: The purpose of this study was to characterize the mechanisms of Günther Tulip filter (GTF) tilting during transfemoral placement in an experimental model with further validation in a clinical series. MATERIALS AND METHODS: In an experimental study, 120 GTF placements in an inferior vena cava (IVC) model were performed using 6 configurations of pre-deployment filter position. The angle between the pre-deployment filter axis and IVC axis, and the proximity of the constrained filter legs to IVC wall prior to deployment were evaluated. The association of those pre-deployment factors with post-deployment filter tilting was analyzed. The association noted in the experimental study was then evaluated in a retrospective clinical series of 21 patients. RESULTS: In the experimental study, there was a significant association between the pre-deployment angle and post-deployment filter tilting (P<0.0001). With a low pre-deployment angle (≤5°), a significant association was noted between filter tilting and the proximity of the constrained filter legs to the far IVC wall (P=0.001). In a retrospective clinical study, a significant association between the pre-deployment angle and post-deployment filter tilting was also noted with a linear regression model (P=0.026). CONCLUSION: Significant association of the pre-deployment angle with post-deployment GTF tilting was shown in both the experimental and clinical studies. The experimental study also showed that proximity of filter legs is relevant when pre-deployment angle is small. Addressing these factors may result in a lower incidence of filter tilting.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA