Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Struct Heart ; 8(3): 100278, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38799807

RESUMEN

Background: The current clinical practice standard is 10% to 20% oversizing of self-expanding valves in transcatheter aortic valve replacement. We aimed to determine whether >20% oversizing of self-expanding valves (Medtronic Evolut) would lead to better valve performance with similar or better outcomes. Methods: From October 2011 to December 2016, we approached all transcatheter aortic valve replacement patients with a conscious attempt at large oversizing (>20%). The most common valve used, excluding those used in valve-in-valve patients, was the 29-mm Evolut R (29%). We used a retrospective chart review to compare moderate oversizing (group 1; 10% to 20%) with large oversizing (group 2; >20%). Results: Of 556 patients, 45% were male; the overall mean Society of Thoracic Surgeons risk score was 5.8 ± 3.8. Eighty-five (15%) patients needed a pacemaker, and 21 (3.8%) developed significant paravalvular leak. Mean oversizing was 20.3% ± 6.0%, with 41.4% of patients included in group 1 and 54.5% in group 2. Incidences of complications in group 2 vs. group 1 were as follows: a) paravalvular leak (2.0 vs. 6.1%; odds ratio = 0.31, p = 0.01), b) pacemaker (15 vs. 14%), c) gastrointestinal bleed (n = 4 vs. 0; 1.3 vs. 0.0%; p = 0.03), d) annular dissection (n = 1 vs. 0; 0.3 vs. 0%; p = 0.29), e) mortality (n = 5 vs. 4; 1.6 vs. 1.7%). Incidence of paravalvular leak was higher in those who died than survivors (13 vs. 1.3%; p ≤ 0.0001). Conclusions: These data suggest that, in current self-expanding valves, >20% oversizing delivers a significantly lower prevalence of paravalvular leak without an increase in other complications. Since paravalvular leak is associated with increased mortality, >20% oversizing may represent a superior prosthesis choice.

3.
J Am Soc Echocardiogr ; 37(7): 698-705, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38490315

RESUMEN

Interventional echocardiography is a rapidly growing field within the disciplines of cardiology and anesthesiology, with the rise of advanced transcatheter procedures making skilled imagers more important than ever. However, these procedures also involve frequent manipulation of the transesophageal echocardiography probe, which means interventional echocardiographers (IEs) are at risk of long-term occupational radiation exposure. Studies have shown that radiation exposure is linked to various health issues, including cancer, cataracts, hypertension, hyperlipidemia, endothelial dysfunction, vascular aging, and early atherosclerosis. While there is increasing awareness of the occupational radiation dose limits and the need for better shielding methods, the importance of radiation safety for the IE is still not sufficiently prioritized in most cardiac catheterization laboratories/hybrid operating rooms. This is partly due to a paucity of studies looking at long-term radiation exposure to the IE, as this field is newer than that of interventional cardiologists.


Asunto(s)
Exposición Profesional , Exposición a la Radiación , Humanos , Exposición Profesional/prevención & control , Exposición a la Radiación/prevención & control , Ecocardiografía/métodos , Ultrasonografía Intervencional/métodos , Protección Radiológica/métodos , Dosis de Radiación
5.
Circ Cardiovasc Imaging ; 17(2): e015712, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38377241

RESUMEN

BACKGROUND: Coronary artery calcium computed tomography (CAC) is an important tool for identifying subclinical atherosclerosis and cardiovascular risk stratification. Despite robust evidence and inclusion in current guidelines, CAC is considered investigational by some US insurance carriers and requires out-of-pocket expenses. CAC can be obtained via self-referral (SR) or physician referral (PR). We aimed to examine differences in patient, socioeconomic, and CAC characteristics between referral groups. METHODS: We evaluated demographic, medical history, and CAC results of consecutive patients with a CAC completed at one of multiple Wisconsin sites from March 1, 2019, to June 30, 2021. We separated patients into SR and PR groups. Through census data, we analyzed socioeconomic variables at the block level including race and ethnicity, median income, average household size, and high school completion in the areas where patients resided at the time of CAC. RESULTS: The final analysis included 19 726 patients: 13 835 (70.1%) PR and 5891 (29.9%) SR. Most patients in both groups were White (95.2% versus 95.1%), with the Black/African American population representing 2.7% (SR) and 2.3% (PR). The PR group had a higher prevalence of cardiovascular risk factors. SR patients were more likely to have a score of 0 (41.2% versus 38.1%; P<0.001); PR patients had a higher prevalence of CAC >300 (16.8% versus 14.8%; P<0.001). SR patients were more likely to be women (55.1% versus 48.9%; P<0.001) and were found to live in higher income areas (19.5% versus 16.4%; P<0.001). Patients from low-income areas comprised the smallest proportion in both groups (7.5%). CONCLUSIONS: Patients who obtain out-of-pocket CAC live predominantly in medium- and high-income areas, and patients from lower income locations are less likely to obtain CAC despite having more cardiovascular disease risk factors. Consideration should be made from a policy perspective to promote health equity and improve utilization of CAC testing among underrepresented groups.


Asunto(s)
Enfermedad de la Arteria Coronaria , Calcificación Vascular , Humanos , Femenino , Masculino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Calcio , Vasos Coronarios/diagnóstico por imagen , Promoción de la Salud , Factores de Riesgo , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/epidemiología , Medición de Riesgo
7.
J Am Soc Echocardiogr ; 37(3): 338-351, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38008131

RESUMEN

BACKGROUND: Patients with hypertrophic cardiomyopathy (HCM) have been shown to exhibit abnormal diastolic vessel flow; however, flow pattern profiles and their possible association with different grades of diastolic dysfunction have not been studied. Color Doppler two-dimensional echocardiography permits visualization of the septal perforator arteries, and pulsed-wave Doppler allows recording of diastolic septal artery flow (SAF). Through routine visualization of the septal perforator arteries and acquisition of SAF, we noticed 3 patterns of SAF in patients with HCM. In this study, we aimed to assess the feasibility of the acquisition of SAF and to describe types of SAF in an HCM cohort and their associations with diastolic function. METHODS: We reviewed two-dimensional echocardiograms and the electronic records of 108 patients with HCM in whom septal artery color and spectral Doppler had been performed. The peak diastolic and end-diastolic velocities, diastolic slope, diastolic flow time-velocity integral, and systolic flow reversal of the septal perforator arteries were recorded with pulsed-wave Doppler. Echocardiographic and clinical characteristics were analyzed. RESULTS: A reproducible pulsed-wave Doppler tracing was recorded in 54% of patients with HCM. Three distinct patterns of SAF were identified: type 1-smooth, linear holodiastolic velocity decrease; type 2-with presence of an atrial dip; and type 3-biphasic velocity decrease with an early, rapid diastolic slope and a mid-to-late gentle slope. These 3 SAFs correlated with different grades of diastolic dysfunction. CONCLUSION: Septal artery flow could be detected in more than 50% of patients with HCM. Three distinct types of SAF were identified, correlating with different grades of diastolic dysfunction. These 3 types of SAF can provide additional information about left ventricular end-diastolic pressure and diastolic function in patients with HCM in whom diastolic function may be difficult to determine.


Asunto(s)
Cardiomiopatía Hipertrófica , Humanos , Velocidad del Flujo Sanguíneo , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Diástole , Ecocardiografía
8.
Am J Cardiol ; 208: 37-43, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37812864

RESUMEN

Optimal timing for aortic valve replacement in symptomatic patients with less than severe aortic stenosis (AS) is not well defined. There is limited information on the benefit of valve replacement in these patients. Symptomatic patients with less than severe AS, defined as a mean aortic gradient ≥20 and <40 mm Hg, peak aortic velocity >3 and <4 m/s, and aortic valve area >1.0 and <1.5 cm2, enrolled in the Society for Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy Registry and who underwent attempted supra-annular, self-expanding transcatheter aortic valve replacement (TAVR) were reviewed. Site-reported valve hemodynamics, clinical events, and quality of life metrics were analyzed at 30 days and 1 year after the procedure. A total of 1,067 patients with attempted TAVR (mean age 78.4 ± 8.4 years; Society for Thoracic Surgery score 4.7 ± 3.4%) were found to have symptoms but less than severe AS. From baseline to postprocedure, mean gradient decreased (29.9 ± 4.9 vs 8.4 ± 4.8 mm Hg, p <0.001), and aortic valve area increased (1.2 ± 0.1 vs 2.2 ± 0.7 cm2, p <0.001). Clinical events included 30-day and 1-year all-cause mortality (1.5% and 9.6%), stroke (2.2% and 3.3%), and new pacemaker implantation (18.1% and 20.9%). There were statistically significant improvements in the New York Heart Association functional class and Kansas City Cardiomyopathy Questionnaire at 30 days and 1 year. In conclusion, patients with symptomatic but less than severe AS who underwent supra-annular, self-expanding TAVR experienced improved valve hemodynamics and quality of life measures 1 year after the procedure. Randomized studies of TAVR versus a control arm in symptomatic patients with less than severe AS are ongoing.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Calidad de Vida , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Ecocardiografía , Factores de Riesgo
9.
J Am Soc Echocardiogr ; 36(10): 1043-1054.e3, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37406714

RESUMEN

BACKGROUND: Pressure-strain loop analysis is a novel echocardiographic technique to calculate myocardial work indices that has not been applied to patients with apical hypertrophic cardiomyopathy (ApHCM). We hypothesized that myocardial work indices differ between patients with ApHCM and those with non-ApHCM. This study aimed to (1) evaluate myocardial work indices in patients with ApHCM compared with those with non-ApHCM, (2) describe associations with relevant clinical variables, and (3) examine associations with significant late gadolinium enhancement (LGE) on cardiac magnetic resonance imaging. METHODS: We retrospectively identified 48 patients with ApHCM and 69 with non-ApHCM who had measurements of global longitudinal strain (GLS), global work index (GWI), global constructive work (GCW), global wasted work, and global work efficiency. We evaluated available cardiac magnetic resonance imaging data on 34 patients with ApHCM and 51 with non-ApHCM. Multivariable regression models correcting for traditional cardiac risk factors were used to evaluate the associations of myocardial work indices with relevant clinical variables. RESULTS: Median GLS (-11% vs -18%, P < .001), GWI (966 mm Hg% vs 1803 mm Hg%, P < .001), and GCW (1,050 mm Hg% vs 1,988 mm Hg%, P < .001) were significantly impaired in patients with ApHCM compared with those with non-ApHCM. Increasing N-terminal pro b-type natriuretic peptide, abnormal ultrasensitive troponin, and increasing maximal left ventricular wall thickness were significantly associated with reduced GWI and GCW in patients with ApHCM (P < .05). Global constructive work had only modest accuracy (area under the curve [AUC] = 0.70) to predict LGE in patients with ApHCM. However, in patients with non-ApHCM, GLS was the strongest predictor of LGE (AUC = 0.91), with a -17% cutoff yielding 81% sensitivity and 80% specificity. CONCLUSION: Myocardial work indices are significantly impaired in patients with ApHCM compared to those with non-ApHCM and correlate with important clinical variables. Global longitudinal strain, GWI, and GCW are more strongly predictive of fibrosis in patients with non-ApHCM than ApHCM.

10.
Front Psychol ; 14: 1104973, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36935969

RESUMEN

The present study examines the mediating role of emotion-focused and problem-focused coping between stress and psychological well-being during the COVID-19 pandemic. The sample comprised 501 (312 women and 184 men aged between 18 and 42) Indians who experienced the first-ever continued lockdown in India during the COVID-19 pandemic. The results of this study confirmed the presence of perceived stress due to the lockdown and pandemic among participants. Furthermore, perceived stress, coping including emotion-focused and problem-focused, and psychological well-being were found to be interrelated. The serial mediation analysis revealed that participants dealt with stress by choosing emotion-focused coping first as an immediate resort. After a reappraisal of stress-inducing situations, they used problem-focused coping, and this sequence of constant coping mechanisms helped maintain their psychological well-being. The findings of this study can be applied to develop strategies for people's mental health by public health organizations and health professionals.

11.
Circ Cardiovasc Imaging ; 16(2): e014419, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36734221

RESUMEN

Myocardial work is an emerging tool in echocardiography that incorporates left ventricular afterload into global longitudinal strain analysis. Myocardial work correlates with myocardial oxygen consumption, and work efficiency can also be assessed. Myocardial work has been evaluated in a variety of clinical conditions to assess the added value of myocardial work compared to left ventricular ejection fraction and global longitudinal strain. This review showcases the current use of myocardial work in adult echocardiography and its possible role in cardiac pathologies.


Asunto(s)
Estenosis de la Válvula Aórtica , Función Ventricular Izquierda , Adulto , Humanos , Volumen Sistólico , Corazón , Ecocardiografía
12.
JAMA Cardiol ; 8(2): 111-119, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36515976

RESUMEN

Importance: The frequency and clinical importance of structural valve deterioration (SVD) in patients undergoing self-expanding transcatheter aortic valve implantation (TAVI) or surgery is poorly understood. Objective: To evaluate the 5-year incidence, clinical outcomes, and predictors of hemodynamic SVD in patients undergoing self-expanding TAVI or surgery. Design, Setting, and Participants: This post hoc analysis pooled data from the CoreValve US High Risk Pivotal (n = 615) and SURTAVI (n = 1484) randomized clinical trials (RCTs); it was supplemented by the CoreValve Extreme Risk Pivotal trial (n = 485) and CoreValve Continued Access Study (n = 2178). Patients with severe aortic valve stenosis deemed to be at intermediate or increased risk of 30-day surgical mortality were included. Data were collected from December 2010 to June 2016, and data were analyzed from December 2021 to October 2022. Interventions: Patients were randomized to self-expanding TAVI or surgery in the RCTs or underwent self-expanding TAVI for clinical indications in the nonrandomized studies. Main Outcomes and Measures: The primary end point was the incidence of SVD through 5 years (from the RCTs). Factors associated with SVD and its association with clinical outcomes were evaluated for the pooled RCT and non-RCT population. SVD was defined as (1) an increase in mean gradient of 10 mm Hg or greater from discharge or at 30 days to last echocardiography with a final mean gradient of 20 mm Hg or greater or (2) new-onset moderate or severe intraprosthetic aortic regurgitation or an increase of 1 grade or more. Results: Of 4762 included patients, 2605 (54.7%) were male, and the mean (SD) age was 82.1 (7.4) years. A total of 2099 RCT patients, including 1128 who received TAVI and 971 who received surgery, and 2663 non-RCT patients who received TAVI were included. The cumulative incidence of SVD treating death as a competing risk was lower in patients undergoing TAVI than surgery (TAVI, 2.20%; surgery, 4.38%; hazard ratio [HR], 0.46; 95% CI, 0.27-0.78; P = .004). This lower risk was most pronounced in patients with smaller annuli (23 mm diameter or smaller; TAVI, 1.32%; surgery, 5.84%; HR, 0.21; 95% CI, 0.06-0.73; P = .02). SVD was associated with increased 5-year all-cause mortality (HR, 2.03; 95% CI, 1.46-2.82; P < .001), cardiovascular mortality (HR, 1.86; 95% CI, 1.20-2.90; P = .006), and valve disease or worsening heart failure hospitalizations (HR, 2.17; 95% CI, 1.23-3.84; P = .008). Predictors of SVD were developed from multivariate analysis. Conclusions and Relevance: This study found a lower rate of SVD in patients undergoing self-expanding TAVI vs surgery at 5 years. Doppler echocardiography was a valuable tool to detect SVD, which was associated with worse clinical outcomes. Trial Registration: ClinicalTrials.gov Identifiers: NCT01240902, NCT01586910, and NCT01531374.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano de 80 o más Años , Femenino , Válvula Aórtica/cirugía , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
15.
J Patient Cent Res Rev ; 8(2): 151-153, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33898649

RESUMEN

The COVID-19 pandemic led to a nationwide shutdown of elective medical procedures. Upon resumption of services, preprocedure nasopharyngeal swab testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was introduced for all patients requiring surgical or other aerosol-generating procedures. We investigated preprocedure COVID-19 testing in one of the largest U.S. health systems. Patients included in this retrospective, observational study were asymptomatic and scheduled for a procedure or surgery. All patients underwent a nasopharyngeal swab test for SARS-CoV-2 performed 24-72 hours prior to a planned procedure. Clinical demographics, type of procedure, test results, and subsequent procedure status were evaluated. Of 38,608 total patients, there were 277 COVID-19-positive patients (positivity rate: 0.72%). Of those 277, 244 (88%) had procedural delays or cancellations. Of the COVID-19-negative patients, 50 (0.13%) required later hospitalization for COVID-19. Median time from preprocedure negative test to admission was 46.3 ± 27.2 days. In the largest series published on preprocedure COVID-19 testing in the early phase of the pandemic, preprocedure COVID-19 positivity was low. Preprocedure COVID-19 testing had a significant impact on clinical management. Rate of COVID-19 cases requiring hospitalization in the months following the procedure was negligible, suggesting health system policies adequately protected patient safety.

16.
J Patient Cent Res Rev ; 8(2): 146-150, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33898648

RESUMEN

PURPOSE: Transesophageal echocardiography is an aerosol-generating procedure, and exercise stress testing is a potentially aerosol-generating activity. Concern has been raised about heightened risk of transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) among health care personnel participating in these procedures. We aimed to investigate the prevalence of past coronavirus disease 2019 (COVID-19) infection in echocardiography and stress laboratory staff. METHODS: All staff who worked in the echocardiography and stress laboratories of one high-traffic urban hospital from March 15, 2020, to June 15, 2020, were asked to voluntarily participate. Those willing to participate were consented, and past COVID-19 infection was confirmed by a SARS-CoV-2 IgG antibody test (ARCHITECT, Abbott Laboratories) from June 15, 2020, to July 3, 2020. Clinical data were collected from the electronic medical record, and self-reported symptoms were documented with a participant survey. RESULTS: A total of 43 staff members (86.0% of 50 total laboratory staff) participated. A majority of participants were less than 40 years old (69.8%), were White (86.0%), and were women (79.1%); mean body mass index was 24.9 ± 4.7 kg/m2. Of the 43 staff members tested for past COVID-19 infection, 3 (7.0%) had a positive SARS-CoV-2 IgG antibody result. There were no unique features in the 3 SARS-CoV-2 antibody-positive subjects; of these, 2 had known prior COVID-19 infection and 1 was asymptomatic. CONCLUSIONS: This study provides clinical data on the seroprevalence of SARS-CoV-2 antibody in echocardiography and stress laboratory staff who regularly participate in a variety of procedures that are or may be aerosol-generating.

17.
J Am Soc Echocardiogr ; 34(8): 807-818, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33895250

RESUMEN

Myocardial work (MW) is a novel technique used in the advanced assessment of left ventricular function. In the past few years, this invasive measure has evolved to become a more attainable noninvasive technique. MW has benefits over left ventricular ejection fraction and global longitudinal strain by speckle-tracking echocardiography, as it includes the afterload-dependent limitation and dynamic myocardial contraction in relationship to various loading conditions. In this article, the authors provide a summary overview and discuss the additive value noninvasive MW provides to left ventricular systolic function assessment. The authors explore the evolution of invasive to noninvasive MW, examine how to acquire and measure, discuss normal reference values, examine its role in a multitude of cardiac conditions that have been investigated in current research, review a variety of clinical applications, and discuss potential limitations. The goal is to allow the reader to see the benefits of this rapidly emerging application and be able to incorporate it into everyday practice.


Asunto(s)
Disfunción Ventricular Izquierda , Función Ventricular Izquierda , Ecocardiografía , Humanos , Contracción Miocárdica , Miocardio , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen
20.
J Patient Cent Res Rev ; 8(1): 68-76, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33511256

RESUMEN

PURPOSE: Coronavirus disease 2019 (COVID-19) presents with a spectrum of disease severity, the most serious cases requiring intensive care. Echocardiography is a front-line tool in evaluating cardiovascular complications of COVID-19 in the intensive care unit (ICU); we analyzed transthoracic echocardiograms obtained from this patient population with state-of-the-art ultrasound technology. METHODS: All patients with COVID-19 requiring ICU admission on whom a transthoracic echocardiogram was obtained were included in the study. Focused transthoracic protocols were performed by experienced sonographers. Echocardiographic variables, including speckle-tracking echocardiography, were collected and analyzed. Clinical information was obtained from the electronic medical record. Patients were followed until discharge. RESULTS: Of 52 total patients (mean age: 59.9 ± 11.6 years), 59.6% were male and 15 (29%) had known prior cardiac disease. Cardiac complications identified on echocardiography were prevalent, occurring in 55.7% of patients. Patients with known prior cardiac disease were more likely to have new or worsening left ventricular dysfunction. Right ventricular dysfunction was the most common abnormality (assessed qualitatively in 18 cases and with advanced echocardiographic methods in 34 cases). Known prior cardiac disease, right ventricular enlargement, and pulmonary hypertension were significantly associated with morbidity and mortality. CONCLUSIONS: Patients requiring intensive care for COVID-19 face significant morbidity and mortality, and cardiac complications occur in the majority of patients admitted to the ICU with COVID-19. Those with known prior cardiac disease fare worse, and other echocardiographic findings (right ventricular enlargement, pulmonary hypertension) are also associated with worse outcomes. State-of-the-art echocardiography performed by experienced sonographers can be critical to identifying cardiac complications and guiding ICU strategy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...