Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 121(19): e2315168121, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38683997

RESUMEN

Accurate prediction of the efficacy of immunotherapy for cancer patients through the characterization of both genetic and phenotypic heterogeneity in individual patient cells holds great promise in informing targeted treatments, and ultimately in improving care pathways and clinical outcomes. Here, we describe the nanoplatform for interrogating living cell host-gene and (micro-)environment (NICHE) relationships, that integrates micro- and nanofluidics to enable highly efficient capture of circulating tumor cells (CTCs) from blood samples. The platform uses a unique nanopore-enhanced electrodelivery system that efficiently and rapidly integrates stable multichannel fluorescence probes into living CTCs for in situ quantification of target gene expression, while on-chip coculturing of CTCs with immune cells allows for the real-time correlative quantification of their phenotypic heterogeneities in response to immune checkpoint inhibitors (ICI). The NICHE microfluidic device provides a unique ability to perform both gene expression and phenotypic analysis on the same single cells in situ, allowing us to generate a predictive index for screening patients who could benefit from ICI. This index, which simultaneously integrates the heterogeneity of single cellular responses for both gene expression and phenotype, was validated by clinically tracing 80 non-small cell lung cancer patients, demonstrating significantly higher AUC (area under the curve) (0.906) than current clinical reference for immunotherapy prediction.


Asunto(s)
Células Neoplásicas Circulantes , Humanos , Células Neoplásicas Circulantes/patología , Células Neoplásicas Circulantes/metabolismo , Microfluídica/métodos , Análisis de la Célula Individual/métodos , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/sangre , Fenotipo , Línea Celular Tumoral , Inmunoterapia/métodos , Perfilación de la Expresión Génica/métodos , Carcinoma de Pulmón de Células no Pequeñas/genética , Carcinoma de Pulmón de Células no Pequeñas/patología , Carcinoma de Pulmón de Células no Pequeñas/sangre , Técnicas Analíticas Microfluídicas/métodos , Técnicas Analíticas Microfluídicas/instrumentación
2.
Lab Chip ; 23(20): 4400-4412, 2023 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-37740394

RESUMEN

The recent COVID-19 outbreak highlighted the need for lab-on-chip diagnostic technology fit for real-life deployment in the field. Existing bottlenecks in multistep analytical microsystem integration and upscalable, standardized fabrication techniques delayed the large-scale deployment of lab-on-chip solutions during the outbreak, throughout a global diagnostic test shortage. This study presents a technology that has the potential to address these issues by redeploying and repurposing the ubiquitous printed circuit board (PCB) technology and manufacturing infrastructure. We demonstrate the first commercially manufactured, miniaturised lab-on-PCB device for loop-mediated isothermal amplification (LAMP) genetic detection of SARS-CoV-2. The system incorporates a mass-manufactured, continuous-flow PCB chip with ultra-low cost fluorescent detection circuitry, rendering it the only continuous-flow µLAMP platform with off-the-shelf optical detection components. Ultrafast, SARS-CoV-2 RNA amplification in wastewater samples was demonstrated within 2 min analysis, at concentrations as low as 17 gc µL-1. We further demonstrate our device operation by detecting SARS-CoV-2 in 20 human nasopharyngeal swab samples, without the need for any RNA extraction or purification. This renders the presented miniaturised nucleic-acid amplification-based diagnostic test the fastest reported SARS-CoV-2 genetic detection platform, in a practical implementation suitable for deployment in the field. This technology can be readily extended to the detection of alternative pathogens or genetic targets for a very broad range of applications and matrices. LoCKAmp lab-on-PCB chips are currently mass-manufactured in a commercial, ISO-compliant PCB factory, at a small-scale production cost of £2.50 per chip. Thus, with this work, we demonstrate a high technology-readiness-level lab-on-chip-based genetic detection system, successfully benchmarked against standard analytical techniques both for wastewater and nasopharyngeal swab SARS-CoV-2 detection.

3.
Methods Mol Biol ; 2461: 123-135, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35727447

RESUMEN

PTO-QuickStep is a quick and easy molecular cloning technique that allows seamless point integration of a DNA fragment, encoding either a tag or a protein, into any position within a target plasmid. The entire process is conducted in a time-efficient and cost-effective manner, without the need of DNA gel purification and enzymatic restriction and ligation. PTO-QuickStep further innovates protein engineering by providing the possibility of integrating a random mutagenesis step (e.g., error-prone PCR) into the workflow, without compromising the time duration required. Random mutagenesis libraries can be quickly and efficiently cloned into a plasmid of interest, thereby accelerating directed evolution. On top of that, PTO-QuickStep can be utilized for rapid integration of noncoding DNA fragments to modify existing plasmids, making it an excellent tool for synthetic biologists.


Asunto(s)
Clonación Molecular , ADN , Biblioteca de Genes , ADN/genética , Mutagénesis , Plásmidos/genética , Reacción en Cadena de la Polimerasa/métodos
4.
Nat Commun ; 12(1): 6994, 2021 11 30.
Artículo en Inglés | MEDLINE | ID: mdl-34848705

RESUMEN

The early diagnosis of active hepatitis C virus (HCV) infection remains a significant barrier to the treatment of the disease and to preventing the associated significant morbidity and mortality seen, worldwide. Current testing is delayed due to the high cost, long turnaround times and high expertise needed in centralised diagnostic laboratories. Here we demonstrate a user-friendly, low-cost pan-genotypic assay, based upon reverse transcriptase loop mediated isothermal amplification (RT-LAMP). We developed a prototype device for point-of-care use, comprising a LAMP amplification chamber and lateral flow nucleic acid detection strips, giving a visually-read, user-friendly result in <40 min. The developed assay fulfils the current guidelines recommended by World Health Organisation and is manufactured at minimal cost using simple, portable equipment. Further development of the diagnostic test will facilitate linkage between disease diagnosis and treatment, greatly improving patient care pathways and reducing loss to follow-up, so assisting in the global elimination strategy.


Asunto(s)
Hepatitis C/diagnóstico , Microfluídica/métodos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Ingeniería Biomédica/métodos , Nitrógeno de la Urea Sanguínea , Pruebas Diagnósticas de Rutina , Diagnóstico Precoz , Genotipo , Hepacivirus , Humanos , Laboratorios , Sistemas de Atención de Punto , Carga Viral , Organización Mundial de la Salud
5.
Int J Mol Sci ; 20(16)2019 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-31405219

RESUMEN

QuickStep is a cloning method that allows seamless point integration of a DNA sequence at any position within a target plasmid using only Q5 High-Fidelity DNA Polymerase and DpnI endonuclease. This efficient and cost-effective method consists of two steps: two parallel asymmetric PCRs, followed by a megaprimer-based whole-plasmid amplification. To further simplify the workflow, enhance the efficiency, and increase the uptake of QuickStep, we replaced the asymmetric PCRs with a conventional PCR that uses phosphorothioate (PTO) oligos to generate megaprimers with 3' overhangs. The ease and speed of PTO-QuickStep were demonstrated through (1) right-first-time cloning of a 1.8 kb gene fragment into a pET vector and (2) creating a random mutagenesis library for directed evolution. Unlike most ligation-free random mutagenesis library creation methods (e.g., megaprimer PCR of whole plasmid [MEGAWHOP]), PTO-QuickStep does not require the gene of interest to be precloned into an expression vector to prepare a random mutagenesis library. Therefore, PTO-QuickStep is a simple, reliable, and robust technique, adding to the ever-expanding molecular toolbox of synthetic biology and expediting protein engineering via directed evolution.


Asunto(s)
Clonación Molecular/métodos , Mutagénesis , Reacción en Cadena de la Polimerasa/métodos , Ingeniería de Proteínas/métodos , ADN/genética , ADN/metabolismo , ADN Polimerasa Dirigida por ADN/metabolismo , Desoxirribonucleasas de Localización Especificada Tipo II/metabolismo , Evolución Molecular Dirigida/métodos , Escherichia coli/genética , Escherichia coli/metabolismo , Biblioteca de Genes , Plásmidos/genética , Plásmidos/metabolismo
6.
Methods Mol Biol ; 1472: 205-14, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27671943

RESUMEN

QuickStep-Cloning is a novel molecular cloning technique that builds upon the concepts of asymmetric PCR and megaprimer-based amplification of whole plasmid. It was designed specifically to address the major drawbacks of previously reported cloning methods. The fully optimized protocol allows for a seamless integration of a long DNA fragment into any position within a plasmid of choice, in a time-efficient and cost-effective manner, without the need of a tedious DNA gel purification, a restriction digestion, and an enzymatic ligation. QuickStep-Cloning can be completed in less than 6 h, significantly faster than most of the existing cloning methods, while retaining high efficiency.


Asunto(s)
Clonación Molecular , Plásmidos/genética , ADN Recombinante/genética , Reacción en Cadena de la Polimerasa , Recombinación Genética , Transformación Bacteriana
7.
J Biol Eng ; 9: 15, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26388935

RESUMEN

BACKGROUND: Molecular cloning is an essential step in biological engineering. Methods involving megaprimer-based PCR of a whole plasmid are promising alternatives to the traditional restriction-ligation-based molecular cloning. Their widespread use, however, is hampered by some of their inherent characteristics, e.g., linear amplification, use of self-annealing megaprimers and difficulty with performing point insertion of DNA. These limitations result in low product yield and reduced flexibility in the design of a genetic construct. RESULT: Here, we present a novel technique of directional cloning, which overcomes these problems yet retaining the simplicity of whole-plasmid amplification. QuickStep-Cloning utilizes asymmetric PCRs to create a megaprimer pair with 3'-overhangs, and hence, facilitates the subsequent exponential whole-plasmid amplification. QuickStep-Cloning generates nicked-circular plasmids, thereby permitting direct bacterial transformation without DNA ligation. It allows DNA fragment integration into any plasmid at any position, in an efficient, time- and cost-effective manner, without tedious intermediate DNA gel purification, modified oligonucleotides, specialty enzymes and ultra-competent cells. The method is compatible with competent E. coli cells prepared using the conventional calcium chloride method. CONCLUSION: QuickStep-Cloning expands the versatility of megaprimer-based cloning. It is an excellent addition to the cloning toolbox, for the benefit of protein engineers, metabolic engineers and synthetic biologists.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...