Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
Circ Arrhythm Electrophysiol ; 13(8): e007726, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32628867

RESUMEN

BACKGROUND: Clinical factors associated with development of intravascular lead adherence (ILA) are unreliable predictors. Because vascular injury in the superior vena cava-right atrium during transvenous lead extraction is more likely to occur in segments with higher degrees of ILA, reliable and accurate assessment of ILA is warranted. We hypothesized that intravascular ultrasound (IVUS) could accurately visualize and quantify ILA and degree of ILA correlates with transvenous lead extraction difficulty. METHODS: Serial imaging of leads occurred before transvenous lead extraction using IVUS. ILA areas were classified as high or low grade. Degree of extraction difficulty was assessed using 2 metrics and correlated with ILA grade. Lead extraction difficulty was calculated for each patient and compared with IVUS findings. RESULTS: One hundred fifty-eight vascular segments in 60 patients were analyzed: 141 (89%) low grade versus 17 (11%) high grade. Median extraction time (low=0 versus high grade=97 seconds, P<0.001) and median laser pulsations delivered (low=0 versus high grade=5852, P<0.001) were significantly higher in high-grade segments. Most patients with low lead extraction difficulty score had low ILA grades. Eighty-six percentage of patients with high lead extraction difficulty score had low IVUS grade, and the degree of transvenous lead extraction difficulty was similar to patients with low IVUS grades and lead extraction difficulty scores. CONCLUSIONS: IVUS is a feasible imaging modality that may be useful in characterizing ILA in the superior vena cava-right atrium region. An ILA grading system using imaging correlates with extraction difficulty. Most patients with clinical factors associated with higher extraction difficulty may exhibit lower ILA and extraction difficulty based on IVUS imaging. Graphic Abstract: A graphic abstract is available for this article.


Asunto(s)
Desfibriladores Implantables , Remoción de Dispositivos , Marcapaso Artificial , Ultrasonografía Intervencional , Vena Cava Superior/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Remoción de Dispositivos/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento , Lesiones del Sistema Vascular/etiología , Vena Cava Superior/lesiones
7.
J Nucl Cardiol ; 25(2): 540-549, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28108979

RESUMEN

BACKGROUND: Diagnostic performance of stress-only imaging using a Cadmium-Zinc-Telluride (CZT) camera has not been directly compared in the same patients to stress-only attenuation-corrected conventional Anger camera images. METHODS: 112 subjects with correlative coronary angiographic data and 40 subjects with <5% pre-test likelihood of coronary disease completed attenuation-corrected stress-only images on a conventional Anger camera and uncorrected upright and supine stress images on a CZT camera. Two readers provided independent, blinded interpretations of stress-only images. RESULTS: Upright and supine stress-only CZT images and attenuation-corrected Anger camera images provided similar positive (reader 1/reader 2, 50.0%/44.1% vs 46.4%/51.9%) and negative (66.7%/64.0% vs 67.9%/67.7%) predictive values (all P = NS) for obstructive coronary artery disease; however, the sensitivity was higher (81.3% vs 58.3%, P = .05), specificity lower (29.7% vs 50.0%, P = .005), and normalcy rate lower (87.5% vs 100%, P = .025) with attenuation-corrected Anger camera images for the first reader with no significant differences between cameras for the second reader. CONCLUSIONS: Stress-only upright and supine CZT imaging was non-inferior statistically to attenuation-corrected stress-only Anger camera imaging. Nevertheless, stress-only CZT imaging may be associated with reduced diagnostic sensitivity for some readers compared to attenuation-corrected Anger camera images, which may be less acceptable clinically compared to stress plus rest images.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Prueba de Esfuerzo , Cámaras gamma , Procesamiento de Imagen Asistido por Computador/métodos , Imagen de Perfusión Miocárdica/instrumentación , Anciano , Cadmio , Enfermedad de la Arteria Coronaria/fisiopatología , Diagnóstico por Computador/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Telurio , Tomografía Computarizada de Emisión de Fotón Único , Zinc
8.
J Nucl Cardiol ; 24(5): 1702-1708, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-27311453

RESUMEN

BACKGROUND: Transient ischemic dilation (TID) of the left ventricle (LV) has not been validated as a marker of extensive coronary artery disease (CAD) for studies using a cadmium-zinc-telluride (CZT) camera with upright imaging. METHODS: TID ratios were obtained from upright stress and rest images on a CZT camera. Separate cut-off values were determined for exercise and for regadenoson stress. The cutoffs were then applied to 28 patients with extensive CAD and 101 patients without extensive CAD. RESULTS: With treadmill exercise, an upright TID ratio ≥1.16 provided a positive predictive value of 50% and a negative predictive value of 85.4% for the identification of extensive CAD. In the regadenoson group, an upright TID ratio of 1.29 provided a positive predictive value of 20% and a negative predictive value of 75.9%. Although not an independent predictor of extensive CAD in all subjects, in subjects with a normal upright LVEF, it provided a predictive value by receiver operating characteristics comparable to the SSS. CONCLUSIONS: Increased upright TID measurements on a CZT camera are associated with extensive CAD. The upright TID measurements can serve in an adjunctive role to SSS, and may be most effective in patients with a normal upright exercise LVEF.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Isquemia/diagnóstico por imagen , Imagen de Perfusión Miocárdica , Tomografía Computarizada de Emisión de Fotón Único , Anciano , Cadmio , Estudios de Cohortes , Angiografía Coronaria , Diagnóstico por Computador , Dilatación , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Purinas/administración & dosificación , Pirazoles/administración & dosificación , Curva ROC , Estudios Retrospectivos , Sensibilidad y Especificidad , Telurio , Zinc
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...