Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Chem Lab Med ; 62(4): 615-626, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37982750

RESUMEN

OBJECTIVES: Immune monitoring is an important aspect in diagnostics and clinical trials for patients with compromised immune systems. Flow cytometry is the standard method for immune cell counting but faces limitations. Best practice guidelines are available, but lack of standardization complicates compliance with e.g., in vitro diagnostic regulations. Limited sample availability forces immune monitoring to predominantly use population-based reference intervals. Epigenetic qPCR has evolved as alternative with broad applicability and low logistical demands. Analytical performance specifications (APS) have been defined for qPCR in several regulated fields including testing of genetically modified organisms or vector-shedding. METHODS: APS were characterized using five epigenetic qPCR-based assays quantifying CD3+, CD4+, CD8+ T, B and NK cells in light of regulatory requirements. RESULTS: Epigenetic qPCR meets all specifications including bias, variability, linearity, ruggedness and sample stability as suggested by pertinent guidelines and regulations. The assays were subsequently applied to capillary blood from 25 normal donors over a 28-day period. Index of individuality (IoI) and reference change values were determined to evaluate potential diagnostic gains of individual reference intervals. Analysis of the IoI suggests benefits for individual over population-based references. Reference change values (RCVs) show that changes of approx. Fifty percent from prior measurement are suggestive for clinically relevant changes in any of the 5 cell types. CONCLUSIONS: The demonstrated precision, long-term stability and obtained RCVs render epigenetic cell counting a promising tool for immune monitoring in clinical trials and diagnosis.


Asunto(s)
Epigénesis Genética , Células Asesinas Naturales , Humanos , Citometría de Flujo
2.
PLoS One ; 14(3): e0213521, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30913220

RESUMEN

Huntington's disease (HD) is a monogenic neurodegenerative disorder caused by an expansion of the CAG trinucleotide repeat domain in the huntingtin (HTT) gene, leading to an expanded poly-glutamine (polyQ) stretch in the HTT protein. This mutant HTT (mHTT) protein is highly prone to intracellular aggregation, causing significant damage and cellular loss in the striatal, cortical, and other regions of the brain. Therefore, modulation of mHTT levels in these brain regions in order to reduce intracellular mHTT and aggregate levels represents a direct approach in the development of HD therapeutics. To this end, assays that can be used to detect changes in HTT levels in biological samples are invaluable tools to assess target engagement and guide dose selection in clinical trials. The Meso Scale Discovery (MSD) ELISA-based assay platform is a robust and sensitive method previously employed for the quantification of HTT. However, the currently available MSD assays for HTT are primarily detecting the monomeric soluble form of the protein, but not aggregated species. In this study, we describe the development of novel MSD assays preferentially detecting mHTT in an aggregated form. Recombinant monomeric HTT(1-97)-Q46, which forms aggregates in a time-dependent manner, was used to characterize the ability of each established assay to distinguish between HTT monomers and HTT in a higher assembly state. Further validation of these assays was performed using brain lysates from R6/2, zQ175 knock-in, and BACHD mouse models, to replicate a previously well-characterized age-dependent increase in brain aggregate signals, as well as a significant reduction of aggregate levels in the striatum following mHTT knockdown with a CAG-directed allele-specific zinc-finger repressor protein (ZFP). Lastly, size exclusion chromatography was used to separate and characterize HTT species from brain tissue lysates to demonstrate specificity of the assays for the fractions containing aggregated HTT. In summary, we demonstrate that the newly developed assays preferentially detect aggregated HTT with improved performance in comparison to previous assay technologies. These assays complement the existing MSD platform assays specific for soluble HTT monomers, allowing for a more comprehensive analysis of disease-relevant HTT species in preclinical models of HD.


Asunto(s)
Bioensayo , Encéfalo/metabolismo , Proteína Huntingtina/metabolismo , Enfermedad de Huntington/metabolismo , Péptidos/metabolismo , Agregación Patológica de Proteínas/metabolismo , Animales , Modelos Animales de Enfermedad , Humanos , Proteína Huntingtina/genética , Enfermedad de Huntington/genética , Enfermedad de Huntington/patología , Ratones , Ratones Transgénicos , Péptidos/genética , Agregación Patológica de Proteínas/genética , Agregación Patológica de Proteínas/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...