Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
AAPS J ; 26(4): 80, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38992280

RESUMEN

Immunogenicity testing and characterization is an important part of understanding the immune response to administration of a protein therapeutic. Neutralizing antibody (NAb) assays are used to characterize a positive anti-drug antibody (ADA) response. Harmonization of reporting of NAb assay performance and results enables efficient communication and expedient review by industry and health authorities. Herein, a cross-industry group of NAb assay experts have harmonized NAb assay reporting recommendations and provided a bioanalytical report (BAR) submission editable template developed to facilitate agency filings. This document addresses key bioanalytical reporting gaps and provides a report structure for documenting clinical NAb assay performance and results. This publication focuses on the content and presentation of the NAb sample analysis report including essential elements such as the method, critical reagents and equipment, data analysis, study samples, and results. The interpretation of immunogenicity data, including the evaluation of the impact of NAb on safety, exposure, and efficacy, is out of scope of this publication.


Asunto(s)
Anticuerpos Neutralizantes , Anticuerpos Neutralizantes/inmunología , Anticuerpos Neutralizantes/sangre , Humanos
2.
AAPS J ; 25(5): 84, 2023 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-37610502

RESUMEN

Tissue factor pathway inhibitor (TFPI) is an endogenous inhibitor of the extrinsic coagulation pathway. In patients with hemophilia A or B, inhibition of TFPI is an alternative therapeutic approach that augments the extrinsic coagulation pathway. Marstacimab is an investigational fully human monoclonal antibody that binds and neutralizes TFPI and is being evaluated as a prophylactic treatment to prevent or reduce the frequency of bleeding episodes in patients with severe hemophilia A or B, with or without inhibitors (antibodies against coagulation factors). However, the efficacy, safety, and pharmacokinetics of marstacimab may be affected by the induction of antidrug antibody (ADA) responses. Here, we describe the evolution and validation of three quasi-quantitative electrochemiluminescence-based methods to detect marstacimab ADAs, starting from their use in a first-in-human phase 1 study to their use in phase 2 and 3 clinical studies of patients with severe hemophilia. For all three methods, validation criteria evaluated the performance of the assays in screening and confirmatory cut points, precision, selectivity, drug tolerance, target interference, and stability. Additional criteria for validation were dilution linearity (Methods 1 and 2) and low positive control concentration, prozone effect, plate homogeneity, and robustness (Method 3). The three methods met validation criteria and are a potentially valuable tool in detecting the induction of marstacimab ADAs during treatment in patients with hemophilia.


Asunto(s)
Hemofilia A , Humanos , Hemofilia A/tratamiento farmacológico , Anticuerpos Monoclonales Humanizados , Anticuerpos Monoclonales
3.
AAPS J ; 25(4): 69, 2023 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-37421491

RESUMEN

Evolving immunogenicity assay performance expectations and a lack of harmonized neutralizing antibody validation testing and reporting tools have resulted in significant time spent by health authorities and sponsors on resolving filing queries. A team of experts within the American Association of Pharmaceutical Scientists' Therapeutic Product Immunogenicity Community across industry and the Food and Drug Administration addressed challenges unique to cell-based and non-cell-based neutralizing antibody assays. Harmonization of validation expectations and data reporting will facilitate filings to health authorities and are described in this manuscript. This team provides validation testing and reporting strategies and tools for the following assessments: (1) format selection; (2) cut point; (3) assay acceptance criteria; (4) control precision; (5) sensitivity including positive control selection and performance tracking; (6) negative control selection; (7) selectivity/specificity including matrix interference, hemolysis, lipemia, bilirubin, concomitant medications, and structurally similar analytes; (8) drug tolerance; (9) target tolerance; (10) sample stability; and (11) assay robustness.


Asunto(s)
Anticuerpos Neutralizantes , Preparaciones Farmacéuticas , Tolerancia a Medicamentos
4.
AAPS J ; 24(6): 113, 2022 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-36307592

RESUMEN

A clear scientific and operational need exists for harmonized bioanalytical immunogenicity study reporting to facilitate communication of immunogenicity findings and expedient review by industry and health authorities. To address these key bioanalytical reporting gaps and provide a report structure for documenting immunogenicity results, this cross-industry group was formed to establish harmonized recommendations and a develop a submission template to facilitate agency filings. Provided here are recommendations for reporting clinical anti-drug antibody (ADA) assay results using ligand-binding assay technologies. This publication describes the essential bioanalytical report (BAR) elements such as the method, critical reagents and equipment, study samples, results, and data analysis, and provides a template for a suggested structure for the ADA BAR. This publication focuses on the content and presentation of the bioanalytical ADA sample analysis report. The interpretation of immunogenicity data, including the evaluation of the impact of ADA on safety, exposure, and efficacy, is out of scope of this publication.


Asunto(s)
Anticuerpos , Anticuerpos Neutralizantes
5.
Pediatr Blood Cancer ; 69(8): e29764, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35678616

RESUMEN

Data from registrational trials of pediatric venous thromboembolism (VTE) treatment are sparse, especially among cancer patients. We conducted a prospective, multicenter, open-label trial (NCT00952380) on dose-finding, safety, and efficacy (measured by 90-day risks of clinically relevant bleeding [CRB] and symptomatic recurrent VTE [srVTE]) of twice-daily subcutaneous dalteparin for acute VTE treatment in patients ≤18 years old. Among 38 patients (cancer, n = 26; noncancer, n = 12), median dalteparin dose requirements per kilogram varied with age but not cancer status. Risks of CRB and srVTE were <4% in cancer and noncancer subgroups. Dalteparin is an important FDA-approved treatment for pediatric VTE, particularly with cancer.


Asunto(s)
Neoplasias , Tromboembolia Venosa , Adolescente , Anticoagulantes/efectos adversos , Niño , Dalteparina/efectos adversos , Hemorragia/inducido químicamente , Hemorragia/tratamiento farmacológico , Humanos , Neoplasias/complicaciones , Neoplasias/tratamiento farmacológico , Estudios Prospectivos , Tromboembolia Venosa/tratamiento farmacológico
6.
J Clin Pharmacol ; 61(2): 172-180, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32827160

RESUMEN

This article describes the population pharmacokinetics (PK) of dalteparin in pediatric patients with venous thromboembolism (VTE). A prospective multicenter open-label study was conducted in children who required anticoagulation for the treatment of VTE. The study population included children with and without cancer. The goal was to describe the pharmacokinetics of dalteparin using anti-Xa as a surrogate marker and to determine the dose required to achieve therapeutic anti-Xa levels (0.5-1.0 IU/mL). The anti-Xa data were supplemented with 2 published studies and analyzed using population pharmacokinetic approaches. The pharmacokinetics of dalteparin following subcutaneous injection in pediatric patients was described by a 1-compartment model with linear absorption and elimination. Body weight was added as a covariate on both CL/F and Vd/F as a power function with fixed exponents of 0.75 and 1.0, respectively. The estimates of CL/F and Vd/F in the full model were 929 mL/h and 7180 mL, respectively, for a reference female patient aged 12 years with body weight of 43 kg. Body weight-normalized CL/F decreased with age. Cancer status and sex did not have significant effects on CL/F and Vd/F. Simulations were conducted to select starting doses of dalteparin that would rapidly achieve therapeutic anti-Xa levels. These simulations suggested that the recommended starting doses of dalteparin administered subcutaneously in pediatric patients of different age cohort groups for treatment of VTE were 150 IU/kg every 12 hours (1 month to <2 years), 125 IU/kg every 12 hours (≥2 to <8 years), and 100 IU/kg every 12 hours (≥8 to <19 years).


Asunto(s)
Anticoagulantes/farmacocinética , Anticoagulantes/uso terapéutico , Dalteparina/farmacocinética , Dalteparina/uso terapéutico , Tromboembolia Venosa/tratamiento farmacológico , Adolescente , Factores de Edad , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Biomarcadores , Peso Corporal , Niño , Preescolar , Dalteparina/administración & dosificación , Dalteparina/efectos adversos , Inhibidores del Factor Xa/farmacocinética , Inhibidores del Factor Xa/uso terapéutico , Femenino , Humanos , Lactante , Recién Nacido , Inyecciones Subcutáneas , Masculino , Tasa de Depuración Metabólica , Estudios Prospectivos , Factores Sexuales
7.
AAPS J ; 21(5): 76, 2019 06 18.
Artículo en Inglés | MEDLINE | ID: mdl-31214862

RESUMEN

Anti-drug antibody (ADA) assay selectivity is evaluated during assay validation to assess the potential for individual matrices to interfere with detection of ADA. While current EMA and FDA guideline documents suggest comparative analysis with and without matrix, they do not provide specific recommendations on the acceptance criteria such as an acceptable percent positive control (PC) recovery range or positive rate. Industry has adopted an approach where recovery of PC spiked sample is expected to fall within ± 20% (80 to 120%) vs. that for the PC material spiked in negative control matrix or assay buffer. Here, it is proposed that ADA assay selectivity evaluated using a qualitative assessment of PC recovery vs. a PK-like quantitative method may be more appropriate. The PC recovery test should focus on the reliability of the method to detect the low PC level in individual samples and avoid false-negative ADA reporting. Therefore, it is proposed that assessment of high PC level as well as the assessment of quantitative percent recovery (within ± 20%) should not be included in the test. The recovery test may be viewed as acceptable should a pre-selected number of individual samples (for example at least 8 or 9 out of 10) prepared at the low PC concentration of the assay score as ADA positive.


Asunto(s)
Anticuerpos Monoclonales/inmunología , Anticuerpos/inmunología , Humanos , Inmunoensayo/métodos , Reproducibilidad de los Resultados
8.
AAPS J ; 21(3): 46, 2019 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-30927117

RESUMEN

Immunogenicity is a major challenge for protein therapeutics which can potentially reduce drug efficacy and safety and is often being monitored by anti-drug antibody (ADA) and neutralizing antibody (NAb) assays. Circulating targets and residual drugs in matrices can have significant impacts on accuracy of results from ADA and NAb assays, and sufficient drug and target tolerance for these assays are necessary. Here, we report the development of a competitive ligand binding (CLB) NAb assay for an anti-TFPI (tissue factor pathway inhibitor) monoclonal antibody (PF-06741086) with high drug and target tolerance to support ongoing clinical studies. A double acid affinity capture elution approach was used to mitigate drug interference, and a robust target removal strategy was employed to enhance target tolerance. The validated NAb assay has sensitivity of 313 ng/mL, drug tolerance of 50 µg/mL, and target tolerance of 1200 ng/mL. A step-by-step tutorial of assay development is described in this manuscript along with the rationale for using a high drug/target tolerant NAb assay. The NAb assay cut point factor obtained was 0.78. Other assay performance characteristics, e.g., precision and selectivity, are also discussed. This validated method demonstrated a superior drug and target tolerance to warrant specific and precise characterization of the NAb responses in support of ongoing clinical studies.


Asunto(s)
Anticuerpos Monoclonales Humanizados/inmunología , Anticuerpos Neutralizantes/inmunología , Bioensayo/métodos , Desarrollo de Medicamentos/métodos , Lipoproteínas/antagonistas & inhibidores , Anticuerpos Monoclonales Humanizados/farmacología , Unión Competitiva , Tolerancia a Medicamentos/inmunología , Humanos , Tolerancia Inmunológica , Inmunoensayo/métodos , Ligandos , Unión Proteica , Proteínas Recombinantes/metabolismo
9.
Bioanalysis ; 9(24): 1967-1996, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29205064

RESUMEN

The 2017 11th Workshop on Recent Issues in Bioanalysis took place in Los Angeles/Universal City, California, on 3-7 April 2017 with participation of close to 750 professionals from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5-day, week-long event - a full immersion week of bioanalysis, biomarkers and immunogenicity. As usual, it was specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small- and large-molecule analysis involving LC-MS, hybrid ligand-binding assay (LBA)/LC-MS and LBA approaches. This 2017 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2017 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 3) covers the recommendations for large-molecule bioanalysis, biomarkers and immunogenicity using LBA. Part 1 (LC-MS for small molecules, peptides and small molecule biomarkers) and Part 2 (hybrid LBA/LC-MS for biotherapeutics and regulatory agencies' inputs) are published in volume 9 of Bioanalysis, issues 22 and 23 (2017), respectively.


Asunto(s)
Biomarcadores/análisis , Inmunidad Activa , Cromatografía Liquida , Conferencias de Consenso como Asunto , Tolerancia a Medicamentos , Guías como Asunto , Ligandos , Espectrometría de Masas , Farmacocinética
10.
AAPS J ; 19(6): 1550-1563, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28971363

RESUMEN

As biomarkers continue to become an integral part of drug development and decision-making, there are increased expectations for reliable and quantitative assays. Protein biomarker assay results are directly influenced by the calibrator material. The selection of calibrator material presents many challenges that impact the relative accuracy and performance of the assay. There is an industry-wide challenge finding reliable and well-characterized calibrator material with good documentation. Several case studies are presented that demonstrate some of the challenges involved in selecting appropriate calibrators along with the resolutions that were ultimately applied. From these experiences, we present here a set of recommendations for selecting and characterizing calibrator material based on the intended purpose of the assay. Finally, we introduce a commutability approach, based on common clinical chemistry practices, which can be used to demonstrate inter-changeability with calibrator materials across multiple lots and technology platforms for all types of protein biomarker assays.


Asunto(s)
Biomarcadores/análisis , Proteínas/análisis , Calibración
11.
Bioanalysis ; 8(23): 2475-2496, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27855512

RESUMEN

The 2016 10th Workshop on Recent Issues in Bioanalysis (10th WRIB) took place in Orlando, Florida with participation of close to 700 professionals from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations, and regulatory agencies worldwide. WRIB was once again a weeklong event - A Full Immersion Week of Bioanalysis for PK, Biomarkers and Immunogenicity. As usual, it is specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small and large molecules involving LCMS, hybrid LBA/LCMS, and LBA approaches, with the focus on PK, biomarkers and immunogenicity. This 2016 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. This White Paper is published in 3 parts due to length. This part (Part 3) discusses the recommendations for large molecule bioanalysis using LBA, biomarkers and immunogenicity. Parts 1 (small molecule bioanalysis using LCMS) and Part 2 (Hybrid LBA/LCMS and regulatory inputs from major global health authorities) have been published in the Bioanalysis journal, issues 22 and 23, respectively.


Asunto(s)
Biomarcadores/análisis , Ligandos , Anticuerpos Monoclonales/análisis , Anticuerpos Monoclonales/inmunología , Anticuerpos Monoclonales/farmacocinética , Cromatografía Líquida de Alta Presión , Conferencias de Consenso como Asunto , Agencias Gubernamentales , Humanos , Sustancias Macromoleculares/análisis , Sustancias Macromoleculares/inmunología , Sustancias Macromoleculares/farmacocinética , Espectrometría de Masas , Estudios de Validación como Asunto
12.
AAPS J ; 18(1): 1-14, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26377333

RESUMEN

Multiplex ligand binding assays (LBAs) are increasingly being used to support many stages of drug development. The complexity of multiplex assays creates many unique challenges in comparison to single-plexed assays leading to various adjustments for validation and potentially during sample analysis to accommodate all of the analytes being measured. This often requires a compromise in decision making with respect to choosing final assay conditions and acceptance criteria of some key assay parameters, depending on the intended use of the assay. The critical parameters that are impacted due to the added challenges associated with multiplexing include the minimum required dilution (MRD), quality control samples that span the range of all analytes being measured, quantitative ranges which can be compromised for certain targets, achieving parallelism for all analytes of interest, cross-talk across assays, freeze-thaw stability across analytes, among many others. Thus, these challenges also increase the complexity of validating the performance of the assay for its intended use. This paper describes the challenges encountered with multiplex LBAs, discusses the underlying causes, and provides solutions to help overcome these challenges. Finally, we provide recommendations on how to perform a fit-for-purpose-based validation, emphasizing issues that are unique to multiplex kit assays.


Asunto(s)
Biomarcadores/análisis , Ligandos , Humanos , Juego de Reactivos para Diagnóstico/normas , Estándares de Referencia , Reproducibilidad de los Resultados
13.
Bioanalysis ; 7(13): 1619-31, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26226311

RESUMEN

Identification and characterization of anti-drug antibodies is a critical component of biopharmaceutical drug development. The tiered approach for immunogenicity testing consists of screening, confirmatory, and characterization assays. Herein, we provide recommendations for confirmatory assays by expanding upon published guidance and present common practices across the industry. The authors recommend scientific approaches for development and validation of confirmatory assays using competition methods in ligand-binding assays, along with statistical formulae for routine use and validation. The paper will assist in understanding the confirmatory assay, and carefully implementing validation criteria a priori, as well as during sample analysis. These approaches represent the authors' current knowledge and practices, with the aim that more uniform practices will be applied across the industry.


Asunto(s)
Anticuerpos Monoclonales/inmunología , Bioensayo/métodos , Formación de Anticuerpos , Diseño de Fármacos , Humanos
14.
Bioanalysis ; 7(3): 285-94, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25697187

RESUMEN

AIM: During the early clinical development of a receptor-IgG1 fusion protein (Drug X), a risk based strategy was utilized to evaluate immunogenicity from Phase I through Proof of Concept clinical studies. MATERIALS & METHODS: Three different technology platforms, enzyme-linked immunosorbant assay, electrochemiluminescent assay and newly emerging immuno-PCR were utilized for evaluation of immunogenic response. RESULTS: An ELISA with adequate sensitivity but significant drug interference was replaced by electrochemiluminescent method with improved drug tolerance; however, an inverse correlation was observed between the administered dose and the incidence of anti-drug antibodies. Further evaluation of an immuno-PCR showed reduced drug interference enabling the detection of anti-drug antibodies in the presence of excess amount of Drug X. CONCLUSION: Immuno PCR assay proved to be a feasible platform for anti-drug antibody characterization.


Asunto(s)
Anticuerpos/análisis , Anticuerpos/inmunología , Ensayo de Inmunoadsorción Enzimática/métodos , Preparaciones Farmacéuticas , Reacción en Cadena de la Polimerasa/métodos , Proteínas Recombinantes de Fusión/inmunología , Anticuerpos/sangre , Terapia Biológica , Estudios de Factibilidad , Humanos , Límite de Detección , Mediciones Luminiscentes , Proteínas Recombinantes de Fusión/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...