Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Bioengineering (Basel) ; 10(4)2023 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37106595

RESUMEN

PURPOSE: The assessment of sleep biomechanics (comprising movement and position during sleep) is of interest in a wide variety of clinical and research settings. However, there is no standard method by which sleep biomechanics are measured. This study aimed to (1) compare the intra- and inter-rater reliability of the current clinical standard, manually coded overnight videography, and (2) compare sleep position recorded using overnight videography to sleep position recorded using the XSENS DOT wearable sensor platform. METHODS: Ten healthy adult volunteers slept for one night with XSENS DOT units in situ (on their chest, pelvis, and left and right thighs), with three infrared video cameras recording concurrently. Ten clips per participant were edited from the video. Sleeping position in each clip was coded by six experienced allied health professionals using the novel Body Orientation During Sleep (BODS) Framework, comprising 12 sections in a 360-degree circle. Intra-rater reliability was assessed by calculating the differences between the BODS ratings from repeated clips and the percentage who were rated with a maximum of one section of the XSENS DOT value; the same methodology was used to establish the level of agreement between the XSENS DOT and allied health professional ratings of overnight videography. Bennett's S-Score was used to assess inter-rater reliability. RESULTS: High intra-rater reliability (90% of ratings with maximum difference of one section) and moderate inter-rater reliability (Bennett's S-Score 0.466 to 0.632) were demonstrated in the BODS ratings. The raters demonstrated high levels of agreement overall with the XSENS DOT platform, with 90% of ratings from allied health raters being within the range of at least 1 section of the BODS (as compared to the corresponding XSENS DOT produced rating). CONCLUSIONS: The current clinical standard for assessing sleep biomechanics, manually rated overnight videography (as rated using the BODS Framework) demonstrated acceptable intra- and inter-rater reliability. Further, the XSENS DOT platform demonstrated satisfactory levels of agreement as compared to the current clinical standard, providing confidence for its use in future studies of sleep biomechanics.

2.
Nat Commun ; 14(1): 1661, 2023 03 25.
Artículo en Inglés | MEDLINE | ID: mdl-36966155

RESUMEN

Deubiquitinating enzymes are key regulators in the ubiquitin system and an emerging class of drug targets. These proteases disassemble polyubiquitin chains and many deubiquitinases show selectivity for specific polyubiquitin linkages. However, most biochemical insights originate from studies of single diubiquitin linkages in isolation, whereas in cells all linkages coexist. To better mimick this diubiquitin substrate competition, we develop a multiplexed mass spectrometry-based deubiquitinase assay that can probe all ubiquitin linkage types simultaneously to quantify deubiquitinase activity in the presence of all potential diubiquitin substrates. For this, all eight native diubiquitins are generated and each linkage type is designed with a distinct molecular weight by incorporating neutron-encoded amino acids. Overall, 22 deubiquitinases are profiled, providing a three-dimensional overview of deubiquitinase linkage selectivity over time and enzyme concentration.


Asunto(s)
Enzimas Desubicuitinizantes , Poliubiquitina , Ubiquitinación , Poliubiquitina/metabolismo , Enzimas Desubicuitinizantes/metabolismo , Ubiquitina/metabolismo , Ubiquitinas/metabolismo
3.
Cancer Discov ; 13(3): 672-701, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36745048

RESUMEN

Drugs that kill tumors through multiple mechanisms have the potential for broad clinical benefits. Here, we first developed an in silico multiomics approach (BipotentR) to find cancer cell-specific regulators that simultaneously modulate tumor immunity and another oncogenic pathway and then used it to identify 38 candidate immune-metabolic regulators. We show the tumor activities of these regulators stratify patients with melanoma by their response to anti-PD-1 using machine learning and deep neural approaches, which improve the predictive power of current biomarkers. The topmost identified regulator, ESRRA, is activated in immunotherapy-resistant tumors. Its inhibition killed tumors by suppressing energy metabolism and activating two immune mechanisms: (i) cytokine induction, causing proinflammatory macrophage polarization, and (ii) antigen-presentation stimulation, recruiting CD8+ T cells into tumors. We also demonstrate a wide utility of BipotentR by applying it to angiogenesis and growth suppressor evasion pathways. BipotentR (http://bipotentr.dfci.harvard.edu/) provides a resource for evaluating patient response and discovering drug targets that act simultaneously through multiple mechanisms. SIGNIFICANCE: BipotentR presents resources for evaluating patient response and identifying targets for drugs that can kill tumors through multiple mechanisms concurrently. Inhibition of the topmost candidate target killed tumors by suppressing energy metabolism and effects on two immune mechanisms. This article is highlighted in the In This Issue feature, p. 517.


Asunto(s)
Antineoplásicos , Melanoma , Humanos , Antineoplásicos/farmacología , Receptores de Estrógenos , Inmunoterapia , Melanoma/patología , Linfocitos T CD8-positivos , Microambiente Tumoral , Línea Celular Tumoral , Receptor Relacionado con Estrógeno ERRalfa
4.
J Crohns Colitis ; 17(6): 919-932, 2023 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-36694402

RESUMEN

Biomarkers to guide clinical decision making at diagnosis of inflammatory bowel disease [IBD] are urgently needed. We investigated a composite serum N-glycomic biomarker to predict future disease course in a discovery cohort of 244 newly diagnosed IBD patients. In all, 47 individual glycan peaks were analysed using ultra-high performance liquid chromatography, identifying 105 glycoforms from which 24 derived glycan traits were calculated. Multivariable logistic regression was performed to determine associations of derived glycan traits with disease. Cox proportional hazard models were used to predict treatment escalation from first-line treatment to biologics or surgery (hazard ratio [HR] 25.9, p = 1.1 × 10-12; 95% confidence interval [CI], 8.52-78.78). Application to an independent replication cohort of 54 IBD patients yielded an HR of 5.1 [p = 1.1 × 10-5; 95% CI, 2.54-10.1]. These data demonstrate the prognostic capacity of serum N-glycan biomarkers and represent a step towards personalised medicine in IBD.


Asunto(s)
Colitis Ulcerosa , Enfermedad de Crohn , Enfermedades Inflamatorias del Intestino , Humanos , Colitis Ulcerosa/diagnóstico , Enfermedad de Crohn/complicaciones , Glicómica , Enfermedades Inflamatorias del Intestino/complicaciones , Biomarcadores , Polisacáridos
5.
Biomimetics (Basel) ; 8(1)2022 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-36648788

RESUMEN

Wearable motion sensors, specifically, Inertial Measurement Units, are useful tools for the assessment of orientation and movement during sleep. The DOTs platform (Xsens, Enschede, The Netherlands) has shown promise for this purpose. This pilot study aimed to assess its feasibility and validity for recording sleep biomechanics. Feasibility was assessed using four metrics: Drift, Battery Life, Reliability of Recording, and Participant Comfort. Each metric was rated as Stop (least successful), Continue But Modify Protocol, Continue But Monitor Closely, or Continue Without Modifications (most successful). A convenience sample of ten adults slept for one night with a DOT unit attached to their sternum, abdomen, and left and right legs. A survey was administered the following day to assess participant comfort wearing the DOTs. A subset of five participants underwent a single evaluation in a Vicon (Oxford Metrics, Oxford, UK) motion analysis lab to assess XSENS DOTs' validity. With the two systems recording simultaneously, participants were prompted through a series of movements intended to mimic typical sleep biomechanics (rolling over in lying), and the outputs of both systems were compared to assess the level of agreement. The DOT platform performed well on all metrics, with Drift, Battery Life, and Recording Reliability being rated as Continue Without Modifications. Participant Comfort was rated as Continue But Monitor Closely. The DOT Platform demonstrated an extremely high level of agreement with the Vicon motion analysis lab (difference of <0.025°). Using the Xsens DOT platform to assess sleep biomechanics is feasible and valid in adult populations. Future studies should further investigate the feasibility of using this data capture method for extended periods (e.g., multiple days) and in other groups (e.g., paediatric populations).

6.
Glycoconj J ; 38(6): 747-756, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34283362

RESUMEN

The study of protein O-glycosylation is important in biological research as O-glycans have been reported to regulate a multitude of molecular and cell biology processes occurring in cancer. It is known that alterations in O-glycosylation are involved in the development and progression of cancer. Their easy accessibility makes in vitro established cell lines suitable and useful models for studying biological mechanisms in disease. However, the O-glycosylation analysis of large numbers of samples, as required in systems biology and biomarker discovery studies, is often challenging. In the present study, O-glycans from three human colorectal cancer cell lines and two human pancreatic cancer cell lines were released by semi-automated, high throughput reductive ß-elimination and analysed using ultrahigh resolution MALDI-FT-ICR MS. Automated data integration and processing was performed using MassyTools, where the analyte was automatically included for relative quantitation based on a range of selection criteria including signal-to-noise ratio, mass error and isotopic pattern quality scores. A total of 126 O-glycan compositions, ranging from a single monosaccharide to large oligosaccharides exhibiting complex glycan motifs, were detected. The use of ultrahigh resolution MALDI-FTICR MS enabled glycan identification and quantitation in the matrix region of the spectrum. This approach has the potential to be used for O-glycosylation analysis of large numbers of samples, such as patient sample cohorts.


Asunto(s)
Neoplasias , Polisacáridos , Línea Celular , Glicosilación , Humanos , Polisacáridos/análisis , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
7.
Front Chem ; 9: 678883, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34026735

RESUMEN

Apolipoprotein-CIII (apo-CIII) is a glycoprotein involved in lipid metabolism and its levels are associated with cardiovascular disease risk. Apo-CIII sialylation is associated with improved plasma triglyceride levels and its glycosylation may have an effect on the clearance of triglyceride-rich lipoproteins by directing these particles to different metabolic pathways. Large-scale sample cohort studies are required to fully elucidate the role of apo-CIII glycosylation in lipid metabolism and associated cardiovascular disease. In this study, we revisited a high-throughput workflow for the analysis of intact apo-CIII by ultrahigh-resolution MALDI FT-ICR MS. The workflow includes a chemical oxidation step to reduce methionine oxidation heterogeneity and spectrum complexity. Sinapinic acid matrix was used to minimize the loss of sialic acids upon MALDI. MassyTools software was used to standardize and automate MS data processing and quality control. This method was applied on 771 plasma samples from individuals without diabetes allowing for an evaluation of the expression levels of apo-CIII glycoforms against a panel of lipid biomarkers demonstrating the validity of the method. Our study supports the hypothesis that triglyceride clearance may be regulated, or at least strongly influenced by apo-CIII sialylation. Interestingly, the association of apo-CIII glycoforms with triglyceride levels was found to be largely independent of body mass index. Due to its precision and throughput, the new workflow will allow studying the role of apo-CIII in the regulation of lipid metabolism in various disease settings.

8.
Glycoconj J ; 38(3): 375-386, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33765222

RESUMEN

Antennary fucosylation alterations in plasma glycoproteins have been previously proposed and tested as a biomarker for differentiation of maturity onset diabetes of the young (MODY) patients carrying a functional mutation in the HNF1A gene. Here, we developed a novel LC-based workflow to analyze blood plasma N-glycan fucosylation in 320 diabetes cases with clinical features matching those at risk of HNF1A-MODY. Fucosylation levels measured in two independent research centers by using similar LC-based methods were correlated to evaluate the interlaboratory performance of the biomarker. The interlaboratory study showed good correlation between fucosylation levels measured for the 320 cases in the two centers with the correlation coefficient (r) of up to 0.88 for a single trait A3FG3S2. The improved chromatographic separation allowed the identification of six single glycan traits and a derived antennary fucosylation trait that were able to differentiate individuals carrying pathogenic mutations from benign or no HNF1A mutation cases, as determined by the area under the curve (AUC) of up to 0.94. The excellent (r = 0.88) interlaboratory performance of the glycan biomarker for HNF1A-MODY further supports the development of a clinically relevant diagnostic test measuring antennary fucosylation levels.


Asunto(s)
Diabetes Mellitus Tipo 2/metabolismo , Factor Nuclear 1-alfa del Hepatocito/metabolismo , Polisacáridos/sangre , Polisacáridos/metabolismo , Adulto , Biomarcadores , Diabetes Mellitus Tipo 2/genética , Femenino , Regulación de la Expresión Génica , Factor Nuclear 1-alfa del Hepatocito/genética , Humanos , Laboratorios , Masculino , Mutación , Variaciones Dependientes del Observador , Polisacáridos/química , Adulto Joven
9.
JMIR Med Inform ; 7(3): e9510, 2019 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-31381503

RESUMEN

BACKGROUND: A complex process like the blood transfusion chain could benefit from modern technologies such as radio frequency identification (RFID). RFID could, for example, play an important role in generating logistic and temperature data of blood products, which are important in assessing the quality of the logistic process of blood transfusions and the product itself. OBJECTIVE: This study aimed to evaluate whether location, time stamp, and temperature data generated in real time by an active RFID system containing temperature sensors attached to red blood cell (RBC) products can be used to assess the compliance of the management of RBCs to 4 intrahospital European and Dutch guidelines prescribing logistic and temperature constraints in an academic hospital setting. METHODS: An RFID infrastructure supported the tracking and tracing of 243 tagged RBCs in a clinical setting inside the hospital at the blood transfusion laboratory, the operating room complex, and the intensive care unit within the Academic Medical Center, a large academic hospital in Amsterdam, the Netherlands. The compliance of the management of 182 out of the 243 tagged RBCs could be assessed on their adherence to the following guidelines on intrahospital storage, transport, and distribution: (1) RBCs must be preserved within an environment with a temperature between 2°C and 6°C; (2) RBCs have to be transfused within 1 hour after they have left a validated cooling system; (3) RBCs that have reached a temperature above 10°C must not be restored or must be transfused within 24 hours or else be destroyed; (4) unused RBCs are to be returned to the BTL within 24 hours after they left the transfusion laboratory. RESULTS: In total, 4 blood products (4/182 compliant; 2.2%) complied to all applicable guidelines. Moreover, 15 blood products (15/182 not compliant to 1 out of several guidelines; 8.2%) were not compliant to one of the guidelines of either 2 or 3 relevant guidelines. Finally, 148 blood products (148/182 not compliant to 2 guidelines; 81.3%) were not compliant to 2 out of the 3 relevant guidelines. CONCLUSIONS: The results point out the possibilities of using RFID technology to assess the quality of the blood transfusion chain itself inside a hospital setting in reference to intrahospital guidelines concerning the storage, transport, and distribution conditions of RBCs. This study shows the potentials of RFID in identifying potential bottlenecks in hospital organizations' processes by use of objective data, which are to be tackled in process redesign efforts. The effect of these efforts can subsequently be evaluated by the use of RFID again. As such, RFID can play a significant role in optimization of the quality of the blood transfusion chain.

10.
Arthritis Rheumatol ; 71(10): 1626-1633, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31067000

RESUMEN

OBJECTIVE: Anti-citrullinated protein antibodies (ACPAs) are disease-specific biomarkers in rheumatoid arthritis (RA). More than 90% of IgG ACPAs harbor N-linked glycans in the antibody variable (V) domain. The corresponding N-glycosylation sites in ACPA V-region sequences result from somatic hypermutation, a T cell-dependent process. As ample evidence indicates that T cells drive the maturation of the ACPA response prior to arthritis onset, we undertook this study to investigate whether the presence of glycans in IgG ACPA V domains predicts the transition from predisease autoimmunity to overt RA. METHODS: We analyzed 2 independent sets of serum samples obtained from 126 ACPA-positive first-degree relatives (FDRs) of RA patients. Both sets originated from an Indigenous North American population and comprised cross-sectional and longitudinal samples of individuals who did or did not develop inflammatory arthritis. Serum IgG ACPAs were affinity-purified and subjected to ultra high-performance liquid chromatography-based glycan analysis. RESULTS: In both data sets, FDR-derived IgG ACPA displayed markedly lower levels of V domain glycans (<50%) compared to IgG ACPA from RA patients. Notably, FDRs who later developed RA showed extensive V-domain glycosylation before the onset of arthritis. Moreover, IgG ACPA V-domain glycosylation was strongly associated with future development of RA (hazard ratio 6.07 [95% confidence interval 1.46-25.2]; P = 0.013). CONCLUSION: Extensive glycosylation of the IgG ACPA V domain is present in a subset of predisposed FDRs of Indigenous North American RA patients. The presence of this feature substantially increases the risk of RA development. Based on these findings, we propose that glycosylation of the IgG ACPA V domain represents a predictive marker for RA development in ACPA-positive individuals and may serve to better target prevention measures.


Asunto(s)
Anticuerpos Antiproteína Citrulinada/metabolismo , Artritis Reumatoide/metabolismo , Inmunoglobulina G/metabolismo , Región Variable de Inmunoglobulina/metabolismo , Indígenas Norteamericanos , Polisacáridos/metabolismo , Adulto , Anticuerpos Antiproteína Citrulinada/inmunología , Artritis Reumatoide/inmunología , Familia , Femenino , Glicosilación , Humanos , Inmunoglobulina G/inmunología , Masculino , Persona de Mediana Edad , Hipermutación Somática de Inmunoglobulina , Linfocitos T/inmunología
11.
Sci Rep ; 8(1): 13688, 2018 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-30209257

RESUMEN

Immunoglobulin G (IgG) N-glycosylation is crucial for its effector functions. It is a complex trait, and large sample sets are needed to discover multiple genetic factors that underlie it. While in humans such high-throughput studies of IgG N-glycans became usual, only one has been carried out in mice. Here we describe and validate a method for the relative quantification of IgG Fc-linked N-glycans in a subclass-specific manner using nano-reverse phase liquid chromatography coupled with mass-spectrometry (nanoRP-LC-MS) applied to murine IgG. High-throughput data processing is ensured by the LaCyTools software. We have shown that IgG isolation procedure is the main source of technical variation in the current protocol. The major glycoforms were quantified reliably with coefficients of variation below 6% for all the analytes with relative abundances above 5%. We have applied our method to a sample set of 3 inbred strains: BALB/c, C57BL/6 and C3H and observed differences in subclass-specific and strain-specific N-glycosylation of IgG, suggesting a significant genetic component in the regulation of Fc-linked IgG N-glycosylation.


Asunto(s)
Fragmentos Fc de Inmunoglobulinas/sangre , Inmunoglobulina G/sangre , Animales , Cromatografía Líquida de Alta Presión/métodos , Glicosilación , Ratones , Ratones Endogámicos BALB C , Ratones Endogámicos C3H , Ratones Endogámicos C57BL , Polisacáridos/sangre , Espectrometría de Masa por Ionización de Electrospray/métodos
12.
PLoS One ; 13(7): e0200280, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29979768

RESUMEN

High-performance liquid chromatography (HPLC) is widely used for absolute quantitation. The advent of new columns and HPLC technology has enabled higher sample throughput, and hence, larger scale studies that perform quantitation on different sample types (e.g. healthy controls vs. patients with rheumatoid arthritis) using HPLC are becoming feasible. However, there remains a lack of methods that can analyse the increased number of HPLC samples. To address this in part, the modular toolkit HappyTools has been developed for the high-throughput targeted quantitation of HPLC measurements. HappyTools enables the user to create an automated workflow that includes retention time (tr) calibration, data extraction and the calculation of several quality criteria for data curation. HappyTools has been tested on a biopharmaceutical standard and previously published clinical samples. The results show comparable accuracy between HappyTools, Waters Empower and ThermoFisher Chromeleon. However, HappyTools offered superior precision and throughput when compared with Waters Empower and ThermoFisher Chromeleon. HappyTools is released under the Apache 2.0 license, both the source code and a Windows binary can be freely downloaded from https://github.com/Tarskin/HappyTools.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Análisis de Datos , Programas Informáticos , Humanos , Flujo de Trabajo
13.
Arthritis Res Ther ; 19(1): 160, 2017 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-28679431

RESUMEN

BACKGROUND: The Fc glycosylation of immunoglobulin G (IgG) is well known to associate with rheumatoid arthritis (RA) disease activity. The same may be true for other classes of Igs. In the present study, we sought to determine whether the glycosylation of IgA was different between healthy subjects and patients with RA, as well as whether it was associated with RA disease activity, in particular with the pregnancy-associated improvement thereof or the flare after delivery. METHODS: A recently developed high-throughput method for glycoprofiling of IgA1 was applied to affinity-captured IgA from sera of patients with RA (n = 252) and healthy control subjects (n = 32) collected before, during and after pregnancy. RESULTS: IgA1 O-glycans bore more sialic acids in patients with RA than in control subjects. In addition, levels of bisecting N-acetylglucosamine of the N-glycans at asparagine 144 were higher in the patients with RA. The levels of several N-glycosylation traits were shown to change with pregnancy, similar to what has been shown before for IgG. However, the changes in IgA glycosylation were not associated with improvement or a flare of disease activity. CONCLUSIONS: The glycosylation of IgA differs between patients with RA and healthy control subjects. However, our data suggest only a minor, if any, association of IgA glycosylation with RA disease activity.


Asunto(s)
Artritis Reumatoide/inmunología , Inmunoglobulina A/inmunología , Complicaciones del Embarazo/inmunología , Adulto , Femenino , Humanos , Embarazo
14.
Sci Rep ; 7(1): 3733, 2017 06 16.
Artículo en Inglés | MEDLINE | ID: mdl-28623326

RESUMEN

Sialylation is a glycosylation feature that occurs in different linkages at the non-reducing end of a glycan moiety, the linkage isomers are often differentially associated with various biological processes. Due to very similar physico-chemical properties, the separation of isomeric sialylated glycopeptides remains challenging but of utmost importance in the biomedicine and biotechnology, including biomarker discovery, glyco-engineering and biopharmaceutical characterization. This study presents the implementation of a high-resolution separation platform based on capillary electrophoresis - mass spectrometry (CE-MS) allowing for the selective analysis of α2,3- and α2,6-sialylated glycopeptides. These differentially linked glycopeptides showed an identical fragmentation pattern (collision induced dissociation) but different electrophoretic mobilities, allowing for baseline separation of the different linkages without the need for an extensive sample preparation. The different migration behavior between the two moieties was found to correlate with differences in pKa values. Using a novel methodology adapted from the so-called internal standard CE approach, a relative difference of 3.4·10-2 in pKa unit was determined. This approach was applied for the analysis of tryptic glycopeptides of prostate specific antigen, which shows highly complex and heterogeneous glycosylation. The developed platform therefore appears attractive for the identification of differentially linked sialic acids that may be related to pathological conditions.


Asunto(s)
Glicopéptidos/química , Ácido N-Acetilneuramínico/química , Espectrometría de Masa por Ionización de Electrospray , Conformación de Carbohidratos , Electroforesis Capilar
15.
ACS Appl Mater Interfaces ; 9(11): 10136-10147, 2017 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-28225592

RESUMEN

Proteins are known to be effective building blocks when it comes to structure formation in aqueous environments. Recently, we have shown that submicron colloidal protein particles can also be used to provide structure to liquid oil and form so-called oleogels ( de Vries , A. J. Colloid Interface Sci. 2017 , 486 , 75 - 83 ) . To prevent particle agglomeration, a solvent exchange procedure was used to transfer the aggregates from water to the oil phase. The aim of the current paper was to elucidate on the enhanced stability against agglomeration of heat-set whey protein isolate (WPI) aggregates to develop an alternative for the solvent exchange procedure. Protein aggregates were transferred from water to several solvents differing in polarity to investigate the effect on agglomeration and changes in protein composition. We show that after drying protein aggregates by evaporation from solvents with a low polarity (e.g., hexane), the protein powder shows good dispersibility in liquid oil compared to powders dried from solvents with a high polarity. This difference in dispersibility could not be related to changes in protein composition or conformation but was instead related to the reduction of attractive capillary forces between the protein aggregates during drying. Following another route, agglomeration was also prevented by applying high freezing rates prior to freeze-drying. The rheological properties of the oleogels prepared with such freeze-dried protein aggregates were shown to be similar to that of oleogels prepared using a solvent exchange procedure. This Research Article provides valuable insights in how to tune the drying process to control protein agglomeration to allow for subsequent structure formation of proteins in liquid oil.


Asunto(s)
Agregado de Proteínas , Liofilización , Aceites , Tamaño de la Partícula , Polvos , Solventes
16.
EBioMedicine ; 17: 108-118, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28169190

RESUMEN

OBJECTIVE: The objective of our study is to investigate the Fc glycosylation profiles of both antigen-specific IgG targeted against proteinase 3 (PR3-ANCA) and total IgG as prognostic markers of relapse in patients with Granulomatosis with Polyangiitis (GPA). METHODS: Seventy-five patients with GPA and a PR3-ANCA rise during follow-up were included, of whom 43 patients relapsed within a median period of 8 (2-16) months. The N-glycan at Asn297 of affinity-purified and denatured total IgG and PR3-ANCA was determined by mass spectrometry of glycopeptides in samples obtained at the time of the PR3-ANCA rise and at the time of the relapse or time-matched during remission. RESULTS: Patients with total IgG1 exhibiting low galactosylation or low sialylation were highly prone to relapse after an ANCA rise (HR 3.46 [95%-CI 1.73-6.96], p<0.0001 and HR 3.22 [95%-CI 1.52-6.83], p=0.002, respectively). In relapsing patients, total IgG1 galactosylation, sialylation and bisection significantly decreased and fucosylation significantly increased from the time of the PR3-ANCA rise to the relapse (p<0.0001, p=0.0087, p<0.0001 and p=0.0025), while the glycosylation profile remained similar in non-relapsing patients. PR3-ANCA IgG1 galactosylation, sialylation and fucosylation of PR3-ANCA IgG1 decreased in relapsing patients (p=0.0073, p=0.0049 and p=0.0205), but also in non-relapsing patients (p=0.0007, p=0.0114 and p=0.0002), while bisection increased only in non-relapsing patients (p<0.0001). CONCLUSION: While Fc glycosylation profiles have been associated with clinically manifest autoimmune diseases, in the present study we show that low galactosylation and sialyation in total IgG1 but not PR3-ANCA IgG1 predicts disease reactivation in patients with GPA who experience an ANCA rise during follow-up. We postulate that glycosylation profiles may be useful in pre-emptive therapy studies using ANCA rises as guideline.


Asunto(s)
Granulomatosis con Poliangitis/sangre , Inmunoglobulina G/sangre , Adulto , Anciano , Biomarcadores/sangre , Estudios de Casos y Controles , Femenino , Galactosa/metabolismo , Granulomatosis con Poliangitis/patología , Humanos , Fragmentos Fc de Inmunoglobulinas/sangre , Inmunoglobulina G/inmunología , Masculino , Persona de Mediana Edad , Mieloblastina/inmunología , Ácidos Siálicos/metabolismo
17.
Methods Mol Biol ; 1503: 31-47, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27743357

RESUMEN

This chapter contains a nanoscale liquid chromatography-mass spectrometry method for the glycoform profiling of the conserved Fc N-glycosylation site of monoclonal and polyclonal immunoglobulin G (IgG). It describes in detail LaCyTools, a program for automated data (pre-)processing of the obtained LC-MS data. The minimal sample preparation necessary is explained as well as an optional method for affinity purification of (polyclonal) antibodies from serum or plasma.After (optional) affinity purification, the pure IgG is cleaved with trypsin. The tryptic glycopeptides are separated almost exclusively on their peptide backbone. This ensures similar response factors for all glycoforms in the MS detection and allows the collection of separate glycoform profiles for different IgG isoforms or allotypes. LaCyTools automatically performs label-free (relative) quantitation of the obtained data after minimal manual input and additionally calculates several quality criteria which can be used for data curation at the level of both individual analytes and entire LC-MS runs.


Asunto(s)
Cromatografía Liquida/métodos , Glicómica/métodos , Glicopéptidos/análisis , Fragmentos Fc de Inmunoglobulinas/química , Inmunoglobulina G/química , Espectrometría de Masas/métodos , Cromatografía de Afinidad/métodos , Glicosilación , Ensayos Analíticos de Alto Rendimiento/métodos , Humanos , Desnaturalización Proteica , Programas Informáticos
18.
Sci Rep ; 6: 34001, 2016 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-27666402

RESUMEN

During pregnancy, the mother provides multiple nutrients and substances to the foetus, with maternal immunoglobulin G (IgG) being actively transported to the foetus. Newborns depend on maternal IgG for immune-protection in their first months. The glycosylation of IgG has been shown to influence its dynamics, e.g. receptor binding. While minor differences in IgG glycosylation have been found between IgG derived from maternal blood and umbilical cord blood (UC) of newborn children, the differential glycosylation of maternal and UC plasma has hitherto not been studied. Here, we studied the N-glycosylation of IgG and total plasma proteome of both maternal and UC plasma of 42 pairs of mothers and newborn children. A total of 37 N-glycans were quantified for IgG and 45 for the total plasma N-glycome (TPNG). The study showed slightly higher levels of galactosylation for UC IgG than maternal IgG, confirming previous results, as well as lower bisection and sialylation. Furthermore, the TPNG results showed lower values for galactosylation and sialylation, and higher values for fucosylation in the UC plasma. In conclusion, this study presents some novel insights into IgG glycosylation differences as well as the first broad overview of the differential plasma glycosylation between mothers and newborns.

19.
PLoS One ; 11(9): e0162824, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27610614

RESUMEN

The study of saliva O-glycosylation is receiving increasing attention due to the potential of glycans for disease biomarkers, but also due to easy access and non-invasive collection of saliva as biological fluid. Saliva is rich in glycoproteins which are secreted from the bloodstream or produced by salivary glands. Mucins, which are highly O-glycosylated proteins, are particularly abundant in human saliva. Their glycosylation is associated with blood group and secretor status, and represents a reservoir of potential disease biomarkers. This study aims to analyse and compare O-glycans released from whole human mouth saliva collected 3 times a day from a healthy individual over a 5 days period. O-linked glycans were released by hydrazinolysis, labelled with procainamide and analysed by ultra-high performance liquid chromatography with fluorescence detection (UHPLC-FLR) coupled to electrospray ionization mass spectrometry (ESI-MS/MS). The sample preparation method showed excellent reproducibility and can therefore be used for biomarker discovery. Our data demonstrates that the O-glycosylation in human saliva changes significantly during the day. These changes may be related to changes in the salivary concentrations of specific proteins.


Asunto(s)
Metaboloma , Polisacáridos/metabolismo , Saliva/metabolismo , Animales , Bovinos , Cromatografía Líquida de Alta Presión , Fetuínas/metabolismo , Glicosilación , Humanos , Estudios Longitudinales , Espectrometría de Masas , Procainamida/química , Estándares de Referencia , Reproducibilidad de los Resultados , Coloración y Etiquetado
20.
J Proteome Res ; 15(7): 2198-210, 2016 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-27267458

RESUMEN

Bottom-up glycoproteomics by liquid chromatography-mass spectrometry (LC-MS) is an established approach for assessing glycosylation in a protein- and site-specific manner. Consequently, tools are needed to automatically align, calibrate, and integrate LC-MS glycoproteomics data. We developed a modular software package designed to tackle the individual aspects of an LC-MS experiment, called LaCyTools. Targeted alignment is performed using user defined m/z and retention time (tr) combinations. Subsequently, sum spectra are created for each user defined analyte group. Quantitation is performed on the sum spectra, where each user defined analyte can have its own tr, minimum, and maximum charge states. Consequently, LaCyTools deals with multiple charge states, which gives an output per charge state if desired, and offers various analyte and spectra quality criteria. We compared throughput and performance of LaCyTools to combinations of available tools that deal with individual processing steps. LaCyTools yielded relative quantitation of equal precision (relative standard deviation <0.5%) and higher trueness due to the use of MS peak area instead of MS peak intensity. In conclusion, LaCyTools is an accurate automated data processing tool for high-throughput analysis of LC-MS glycoproteomics data. Released under the Apache 2.0 license, it is freely available on GitHub ( https://github.com/Tarskin/LaCyTools ).


Asunto(s)
Procesamiento Automatizado de Datos/métodos , Glicopéptidos/análisis , Proteómica/métodos , Cromatografía Liquida , Espectrometría de Masas , Proteómica/normas , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...