Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Environ Int ; 181: 108256, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37862862

RESUMEN

Per- and polyfluoroalkyl substances (PFAS) are a group of xenobiotics that are widely distributed throughout the aquatic environment. Many PFAS are possible thyroid hormone (TH) system disrupting compounds, because they have the capacity to -amongst other- inhibit the TH thyroxine (T4) from binding to its transport protein transthyretin (TTR). This study investigated the occurrence of TH-displacing activity in the Dutch water cycle, and more specifically, the contribution of PFAS to this effect. Over one year of monitoring data of 29 PFAS (linear and branched) showed the continuous presence of PFAS in drinking waters and their surface water sources. Secondly, the FITC-T4 and TTR-TRß-CALUX bioassays were mutually compared using positive (HPLC-grade water spiked with PFOA) and negative control samples (HPLC-grade water), as well as relative potency factors (RPFs) of up to 20 PFAS congeners. Both assays were found to be suitable for measuring TH-displacing activity in water samples. As a third aim, a field study was performed in the Dutch water cycle that was comprised of samples from drinking water, surface water, PFAS contaminated sites, and 2 wastewater treatment plants. All samples were analyzed with 1. chemical analysis for 29 PFAS, 2. the FITC-T4 bioassay, and 3. the TTR-TRß-CALUX bioassay. The bioassays mutually showed good correlation (R2 0.85). Bioanalytical equivalent concentrations (BEQ) based on chemically-determined concentrations and RPFs (BEQchem) revealed that analyzed PFAS only explained ≤4.1 % of their activity in water extracts measured by both bioassays (BEQbio). This indicated that as yet unknown compounds contribute to the majority of the measured TH-displacing activity. Moreover, water treatment processes (e.g. DW production from SW) showed a larger contribution of target PFAS to the BEQbio. This could be a first lead to identify unknown compounds that contribute to this activity, and as such, enable the assessment of possible risks associated by the occurrence of TH-displacing activity in water.


Asunto(s)
Agua Potable , Fluorocarburos , Contaminantes Químicos del Agua , Fluoresceína-5-Isotiocianato , Hormonas Tiroideas , Glándula Tiroides , Bioensayo , Receptores beta de Hormona Tiroidea , Contaminantes Químicos del Agua/toxicidad
2.
Rev Sci Instrum ; 91(2): 023507, 2020 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-32113444

RESUMEN

The Charge Exchange Recombination Spectroscopy (CXRS) diagnostic has become a routine diagnostic on almost all major high temperature fusion experimental devices. For the optimized stellarator Wendelstein 7-X (W7-X), a highly flexible and extensive CXRS diagnostic has been built to provide high-resolution local measurements of several important plasma parameters using the recently commissioned neutral beam heating. This paper outlines the design specifics of the W7-X CXRS system and gives examples of the initial results obtained, including typical ion temperature profiles for several common heating scenarios, toroidal flow and radial electric field derived from velocity measurements, beam attenuation via beam emission spectra, and normalized impurity density profiles under some typical plasma conditions.

3.
Rev Sci Instrum ; 87(11): 11E503, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910319

RESUMEN

A photo-elastic modulator based 25-chord motional Stark effect (MSE) diagnostic has been successfully developed and commissioned in Korea Superconducting Tokamak Advanced Research. The diagnostic measures the radial magnetic pitch angle profile of the Stark splitting of a D-alpha line at 656.1 nm by the electric field associated with the neutral deuterium heating beam. A tangential view of the neutral beam provides a good spatial resolution of 1-3 cm for covering the major radius from 1.74 m to 2.28 m, and the time resolution is achieved at 10 ms. An in-vessel calibration before the vacuum closing as well as an in situ calibration during the tokamak operation was performed by means of specially designed polarized lighting sources. In this work, we present the final design of the installed MSE diagnostic and the first results of the commissioning.

4.
Rev Sci Instrum ; 85(11): 11D827, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430240

RESUMEN

The motional Stark effect (MSE) diagnostic is used to measure the radial magnetic pitch angle profile in neutral beam heated plasmas. This information is used to calculate the safety factor, q, with magnetic equilibrium reconstruction codes such as EFIT. The MSE diagnostic is important during active shaping of the q profile to optimize confinement and stability, and it has become a key diagnostic in high performance tokamaks. A multichord photo-elastic modulator (PEM) based MSE system is being developed for a real-time plasma current profile control in Korea Superconducting Tokamak Advanced Research (KSTAR). The PEM-based approach is a standard method that measures the polarization direction of a single Stark line with narrow tunable bandpass filters. A tangential view of the heating beam provides good spatial resolution of 1-3 cm, which provides an opportunity to install 25 spatial channels spanning the major radius from 1.74 m to 2.84 m. Application of real-time control is a long-term technical goal after commissioning the diagnostic in KSTAR, which is expected in 2015. In this paper, we describe the design of this newly-constructed multichord MSE diagnostic in KSTAR.

5.
Rev Sci Instrum ; 83(10): 10D515, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126857

RESUMEN

A feasibility study for the use of core charge exchange recombination spectroscopy on ITER has shown that accurate measurements on the helium ash require a spectrometer with a high etendue of 1mm(2)sr to comply with the measurement requirements [S. Tugarinov et al., Rev. Sci. Instrum. 74, 2075 (2003)]. To this purpose such an instrument has been developed consisting of three separate wavelength channels (to measure simultaneously He/Be, C/Ne, and H/D/T together with the Doppler shifted direct emission of the diagnostic neutral beam, the beam emission (BES) signal), combining high dispersion (0.02 nm/pixel), sufficient resolution (0.2 nm), high efficiency (55%), and extended wavelength range (14 nm) at high etendue. The combined measurement of the BES along the same sightline within a third wavelength range provides the possibility for in situ calibration of the charge eXchange recombination spectroscopy signals. In addition, the option is included to use the same instrument for measurements of the fast fluctuations of the beam emission intensity up to 2 MHz, with the aim to study MHD activity.

6.
Rev Sci Instrum ; 83(10): 10D519, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126860

RESUMEN

Investigation of impurity transport properties in tokamak plasmas is essential and a diagnostic that can provide information on the impurity content is required. Combining charge exchange recombination spectroscopy (CXRS) and beam emission spectroscopy (BES), absolute radial profiles of impurity densities can be obtained from the CXRS and BES intensities, electron density and CXRS and BES emission rates, without requiring any absolute calibration of the spectra. The technique is demonstrated here with absolute impurity density radial profiles obtained in TEXTOR plasmas, using a high efficiency charge exchange spectrometer with high etendue, that measures the CXRS and BES spectra along the same lines-of-sight, offering an additional advantage for the determination of absolute impurity densities.

7.
Rev Sci Instrum ; 81(10): 10D323, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033847

RESUMEN

To overcome the challenge of measuring the fuel ion ratio in the core (ρ<0.3) of ITER, a coordinated effort aiming at developing diagnostic techniques has been initiated. The investigated techniques are novel uses or further development of existing methods such as charge exchange recombination spectrometry, neutron spectrometry, and collective Thomson scattering. An overview of the work on the three diagnostic techniques is presented.

8.
Rev Sci Instrum ; 81(10): 10D929, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033957

RESUMEN

The newly installed electron cyclotron emission imaging diagnostic on ASDEX Upgrade provides measurements of the 2D electron temperature dynamics with high spatial and temporal resolution. An overview of the technical and experimental properties of the system is presented. These properties are illustrated by the measurements of the edge localized mode and the reversed shear Alfvén eigenmode, showing both the advantage of having a two-dimensional (2D) measurement, as well as some of the limitations of electron cyclotron emission measurements. Furthermore, the application of singular value decomposition as a powerful tool for analyzing and filtering 2D data is presented.

9.
Rev Sci Instrum ; 81(10): 10E521, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21034049

RESUMEN

A coherence imaging camera has been set up at Pilot-PSI. The system is to be used for imaging the plasma density through the Stark effect broadening of the H(γ) line. Local density values are then obtained by the Abel inversion of the measured interferometric fringe contrast. This report will present the instrument setup and proof-of-principle demonstration. The inverted spatial electron density profiles obtained near the cascaded arc source of Pilot-PSI in discharges with axial magnetic field of B=0.4 T are compared with an independent measurement of electron density by Thomson scattering and good agreement is found.

10.
Rev Sci Instrum ; 79(10): 10E522, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044504

RESUMEN

An upgraded charge exchange spectroscopy diagnostic has been taken into operation at the TEXTOR tokamak. The angles of the viewing lines with the toroidal magnetic field are close to the pitch angles at birth of fast ions injected by one of the neutral beam injectors. Using another neutral beam for active spectroscopy, injected counter the direction in which fast ions injected by the first beam are circulating, we can simultaneously measure a fast ion tail on the blue wing of the D(alpha) spectrum while the beam emission spectrum is Doppler shifted to the red wing. An analysis combining the two parts of the spectrum offers possibilities to improve the accuracy of the absolute (fast) ion density profiles. Fast beam modulation or passive viewing lines cannot be used for background subtraction on this diagnostic setup and therefore the background has to be modeled and fitted to the data together with a spectral model for the slowing down feature. The analysis of the fast ion D(alpha) spectrum obtained with the new diagnostic is discussed.

11.
Rev Sci Instrum ; 79(10): 10F526, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044670

RESUMEN

The charge exchange recombination spectroscopy system (CXRS) for ITER is designed to measure the core helium concentration, and in addition, profiles of ion temperature and rotation. This highly demanding task, due to the huge background radiation (bremsstrahlung) and the high attenuation of the dedicated diagnostic neutral beam, requires high throughput spectrometers with high resolution. On TEXTOR, a CXRS system has been developed with the aim to test the physics implications of these specifications. (i) A relevant spectrometer has been tested. (ii) A method to determine the helium concentrations from the CXRS intensity, using the beam emission has been evaluated. A 20% discrepancy in beam emission was revealed. (iii) The determination of the magnetic pitch angle by the ratio of Balmer lines showed qualitatively the right behavior, although the accuracy was limited by the polarization sensitivity of the first mirror. (iv) The simulation code developed for the prediction of the CXRS spectra was quantitatively confronted with experimental data.

12.
Phys Rev Lett ; 98(3): 035001, 2007 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-17358689

RESUMEN

The suppression of (neoclassical) tearing modes is of great importance for the success of future fusion reactors like ITER. Electron cyclotron waves can suppress islands, both by driving noninductive current in the island region and by heating the island, causing a perturbation to the Ohmic plasma current. This Letter reports on experiments on the TEXTOR tokamak, investigating the effect of heating, which is usually neglected. The unique set of tools available on TEXTOR, notably the dynamic ergodic divertor to create islands with a fully known driving term, and the electron cyclotron emission imaging diagnostic to provide detailed 2D electron temperature information, enables a detailed study of the suppression process and a comparison with theory.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...