Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
2.
Eur J Cardiothorac Surg ; 33(6): 1043-8, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18448351

RESUMEN

OBJECTIVE: Although the classical Cox-Maze III is the gold standard surgical therapy with a proven efficacy in the treatment of atrial fibrillation (AF), complexity of this procedure has resulted in a search for a simpler, less invasive and more cost-effective method. In this study we evaluated the results of cryosurgical ablation in the treatment of chronic AF in patients undergoing concomitant mitral valve surgery. METHODS: Ninety patients (mean age: 50.9+/-12 years) with chronic AF who were having mitral valve surgery as the main procedure underwent cryoablation with a newly designed N(2)O-based cryotherapy device. Pulmonary vein isolation with or without left atrial appendage closure (group A) was carried out in 65 cases and cryoablative bi-atrial Cox-Maze III (group B) in 25 patients. This additional procedure took only an extra 10 min for group A and about 20 min for group B. Half of the patients received a beta-blocker following the procedure. RESULTS: The overall success rate of cryoablation was 65.5%. Normal sinus rhythm was achieved in 26.7% in the operating room, 10% in ICU and the remaining cases reverted to sinus rhythm during the follow-up period. There were no major ablation-related complications such as bleeding, thromboembolic events or A-V block. The only predictor for failure of ablative procedure was left atrial size of greater than 6 cm. CONCLUSION: Although in this study the efficacy rate of cryoablative surgery was not the same as classical Cox-Maze III, it seems that this procedure is safe, simple, cost-effective and at the same time does not increase the operative time significantly. Using cryoablation may enhance the cure rate of chronic AF during mitral valve surgery.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/métodos , Válvula Mitral/cirugía , Adolescente , Adulto , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/patología , Enfermedad Crónica , Criocirugía/efectos adversos , Criocirugía/instrumentación , Estudios de Factibilidad , Femenino , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Cuidados Posoperatorios/métodos , Pronóstico , Insuficiencia del Tratamiento
3.
J Card Surg ; 23(1): 23-6, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18290882

RESUMEN

A minority of patients with Tetralogy of Fallot (TF) survive into adulthood. These patients have been subjected to a prolong period of cyanosis and hypoxia. The aim of this study is to assess the benefits of total correction of TF in this adult population. From August 1995 to March 2005, fifty one patients underwent total correction of TF. The mean age was 22.2 years (range 16 to 38 years). There were 31 males and 20 females. Twenty two percent of patients were in NYHA functional class III prior to the operation. The mean gradient across the right ventricular outflow tract was 81.7 mmHg (range 30 to 130 mmHg). The operation was performed through the right ventricle in the majority of patients. Transannular patch was used in 33 patients. The mean follow-up period was 42 months ranging from 1 to 116 months. Hospital mortality was 1.9% (1 patient), and one patient died three months after the operation. Post-operatively 87.3% of patients were in NYHA functional class I. During the follow-up period four patients required re-operation; two for residual ventricular septal defect, one for residual pulmonary stenosis and one had pulmonary valve replacement for severe pulmonary regurgitation. Complete repair of TF in adults is feasible with acceptable mortality and morbidity. The main benefit of the operation is functional improvement in this patient population.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Complicaciones Posoperatorias , Tetralogía de Fallot/cirugía , Adolescente , Adulto , Femenino , Mortalidad Hospitalaria , Humanos , Irán/epidemiología , Tiempo de Internación , Estudios Longitudinales , Masculino , Reoperación , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Tetralogía de Fallot/mortalidad , Resultado del Tratamiento
4.
Asian Cardiovasc Thorac Ann ; 15(6): 493-6, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18042774

RESUMEN

The aim of this retrospective study was to compare the different anticoagulation regimens used in pregnant women with prosthetic heart valves. We reviewed 196 pregnancies in 110 women from 1974 to 2000. The patients were divided into two groups: group 1 (142 pregnancies) had warfarin throughout pregnancy; and in group 2 (54 pregnancies), warfarin was replaced by subcutaneous heparin during the first trimester and last two weeks of pregnancy. There were no maternal complications in 129 pregnancies in group 1 and 44 in group 2. There were significantly fewer normal births in group 1 (56; 39.4%) compared to group 2 (39; 72.2%). Group 1 had a significantly higher rate of spontaneous abortion (46.5% vs 14.8%), but group 2 had a higher rate of valve thrombosis. In group 1, women with a warfarin requirement < 5 mg had a lower rate of spontaneous abortion. Warfarin is an effective anticoagulant in pregnant women with mechanical valves but it results in significant fetal loss when the dose is > 5 mg. Heparin is a less effective anticoagulant resulting in more maternal complications, but it is more protective of the fetus.


Asunto(s)
Anticoagulantes/uso terapéutico , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Heparina/uso terapéutico , Complicaciones Cardiovasculares del Embarazo/prevención & control , Trombosis/prevención & control , Warfarina/uso terapéutico , Aborto Espontáneo/inducido químicamente , Administración Oral , Adulto , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Relación Dosis-Respuesta a Droga , Esquema de Medicación , Femenino , Feto/efectos de los fármacos , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Heparina/administración & dosificación , Heparina/efectos adversos , Humanos , Inyecciones Subcutáneas , Selección de Paciente , Embarazo , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Trombosis/etiología , Resultado del Tratamiento , Warfarina/administración & dosificación , Warfarina/efectos adversos
5.
Ann Thorac Surg ; 77(4): 1353-7; discussion 1357-8, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15063265

RESUMEN

BACKGROUND: Recurrent coarctation is an ever-present complication of surgical treatment of coarctation of aorta (CoA) among infants. No single operation appears to have a clear superiority. METHODS: From January 1, 1986, to June 30, 2002, a consecutive series of 181 patients less than 1 year of age (range 1 to 300 days, median 13.5 days) were referred for CoA repair. Neonates accounted for 135 patients, and hypoplastic arch (less than 1 mm/kg plus 1) was present in 107 infants. Coarctation of aorta was simple (group 1) in 71 patients; complicated by ventricular septal defect (group 2) in 62; and complicated by complex congenital heart disease (group 3) in 48. All patients were assessed by right arm/left leg Dynamap pressures and routine follow-up was performed by the cardiologists. Follow-up was complete in all patients (range 6 months to 16 years, median 7.5 years). RESULTS: The overall hospital/30-day mortality was 0.5% (group 1 = 0, group 2 = 0, group 3 = 1 [2.0%]). Complications other than recoarctation occurred in 5 patients (2.7%). Late mortality occurred in 15 (11 at intracardiac repair). Recoarctation, ie, a gradient of more than 20 mm Hg, occurred in 4 patients (2.2%). All 4 patients were noted to have a gradient of more than 10 mm Hg (right arm/left leg) postoperatively and as such had residual coarctation. All 4 were successfully treated by balloon aortoplasty. CONCLUSIONS: Extended arch aortoplasty in association with ductal and coarctation excision provides excellent coarctation repair with a low incidence of recoarctation. Recoarctation occurred only in proximal aortic arch hypoplasia or low birth weight. Balloon aortoplasty easily and effectively relieved the recoarctation in all cases.


Asunto(s)
Aorta Torácica/cirugía , Coartación Aórtica/cirugía , Aorta Torácica/diagnóstico por imagen , Coartación Aórtica/diagnóstico por imagen , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido , Complicaciones Posoperatorias , Radiografía , Recurrencia , Estudios Retrospectivos
6.
Ann Thorac Surg ; 73(3): 951-3, 2002 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11899208

RESUMEN

Acute traumatic transection of the thoracic aorta is most commonly seen in vehicular trauma and is generally accepted to be due to differential deceleration. A second mechanism is proposed for this injury and that is the osseous pinch mechanism. We report a case where aortic transection occurred due to a crush injury and supports the latter mechanism.


Asunto(s)
Aorta Torácica/lesiones , Adulto , Aorta Torácica/diagnóstico por imagen , Fenómenos Biomecánicos , Síndrome de Aplastamiento , Humanos , Masculino , Rotura , Tomografía Computarizada por Rayos X , Heridas y Lesiones/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA