Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biosensors (Basel) ; 14(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38667160

RESUMEN

Galactose monitoring in individuals allows the prevention of harsh health conditions related to hereditary metabolic diseases like galactosemia. Current methods of galactose detection need development to obtain cheaper, more reliable, and more specific sensors. Enzyme-containing amperometric sensors based on galactose oxidase activity are a promising approach, which can be enhanced by means of their inclusion in a redox polymer coating. This strategy simultaneously allows the immobilization of the biocatalyst to the electroactive surface and hosts the electron shuttling units. An additional deposition of capping polymers prevents external interferences like ascorbic or uric acid as well as biofouling when measuring in physiological fuels. This work studies the protection effect of poly(2-methacryloyloxyethyl phosphorylcholine-co-glycidyl methacrylate (MPC) and polyvinylimidazole-polysulfostyrene (P(VI-SS)) when incorporated in the biosensor design for the detection of galactose in human plasma.


Asunto(s)
Técnicas Biosensibles , Galactosa , Polímeros , Humanos , Polímeros/química , Galactosa Oxidasa , Metacrilatos/química
2.
ACS Sens ; 8(4): 1756-1765, 2023 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-36943936

RESUMEN

The lifetime of implantable electrochemical glucose monitoring devices is limited due to the foreign body response and detrimental effects from ascorbic acid (AA) and uric acid (UA) interferents that are components of physiological media. Polymer coatings can be used to shield biosensors from these interferences and prolong their functional lifetime. This work explored several approaches to protect redox polymer-based glucose biosensors against such interferences by designing six targeted multi-layer sensor architectures. Biological interferents, like cells and proteins, and UA and AA interferents were found to have individual effects on the current density and operational stability of glucose biosensors, requiring individual protection and treatment. Protection against biofouling can be achieved using a poly(2-methacryloyloxyethyl phosphorylcholine-co-glycidyl methacrylate) (MPC) zwitterionic polymer coating. An enzyme-scavenging approach was compared to electrostatic repulsion by negatively charged polymers for protection against AA and UA interferences. A multi-layer novel polymer design (PD) system consisting of a cross-linkable negatively charged polyvinylimidazole-polysulfostyrene co-polymer inner layer and a cross-linkable MPC zwitterionic polymer outer layer showed the best protection against AA, UA, and biological interferences. The sensor protected using the novel PD shield displayed the lowest mean absolute relative difference between the glucose reading without the interferent and the reading value with the interferent present and also displayed the lowest variability in sensor readings in complex media. For sensor measurements in artificial plasma, the novel PD extends the linear range (R2 = 0.99) of the sensor from 0-10 mM for the control to 0-20 mM, shows a smaller decrease in sensitivity, and retains high current densities. The application of PD multi-target coating improves sensor performance in complex media and shows promise for use in sensors operating in real conditions.


Asunto(s)
Incrustaciones Biológicas , Técnicas Biosensibles , Glucosa , Glucemia , Polímeros , Ácido Úrico/análisis , Automonitorización de la Glucosa Sanguínea , Ácido Ascórbico , Incrustaciones Biológicas/prevención & control
3.
Biosens Bioelectron ; 219: 114815, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36302333

RESUMEN

Foreign body response (FBR) is a major challenge that affects implantable biosensors and medical devices, including glucose biosensors, leading to a deterioration in device response over time. Polymer shields are often used to mitigate this issue. Zwitterionic polymers (ZPs) are a promising class of materials that reduce biofouling of implanted devices. A series of ZPs each containing tetherable epoxide functional groups was synthesised for application as a polymer shield for eventual application as implantable glucose biosensors. The polymer shields were initially tested for the ability to resist fibrinogen adsorption and fibroblast adhesion. All synthesised ZPs showed comparable behaviour to a commercial Lipidure ZP in resisting fibrinogen adsorption. Nafion, a common anionic shield used against electrochemical interferents, showed higher protein adsorption and comparable cell adhesion resistance as uncoated control surfaces. However, a poly(2-methacryloyloxyethyl phosphorylcholine-co-glycidyl methacrylate) (MPC)-type ZP showed similar behaviour to Lipidure, with approximately 50% reduced fibrinogen adsorption and 80% decrease in fibroblast adhesion compared to uncoated controls. An MPC-coated amperometric glucose biosensor showed comparable current density and a 1.5-fold increase in sensitivity over an uncoated control biosensor, whereas all other polymer shields tested, including Lipidure, Nafion and a poly(ethyleneglycol) polymer, resulted in lower sensitivity and current density. Collectively, these characteristics make MPC-polymer shield coatings an appealing possibility for use in implantable glucose sensors and other implanted devices with the aim of reducing FBR while maintaining sensor performance.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...