Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMJ Open Respir Res ; 10(1)2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37369550

RESUMEN

BACKGROUND: Accurate arterial blood gas (ABG) analysis is essential in the management of patients with hypercapnic respiratory failure, but repeated sampling requires technical expertise and is painful. Missed sampling is common and has a negative impact on patient care. A newer venous to arterial conversion method (v-TAC, Roche) uses mathematical models of acid-base chemistry, a venous blood gas sample and peripheral blood oxygen saturation to calculate arterial acid-base status. It has the potential to replace routine ABG sampling for selected patient cohorts. The aim of this study was to compare v-TAC with ABG, capillary and venous sampling in a patient cohort referred to start non-invasive ventilation (NIV). METHODS: Recruited patients underwent near simultaneous ABG, capillary blood gas (CBG) and venous blood gas (VBG) sampling at day 0, and up to two further occasions (day 1 NIV and discharge). The primary outcome was the reliability of v-TAC sampling compared with ABG, via Bland-Altman analysis, to identify respiratory failure (via PaCO2) and to detect changes in PaCO2 in response to NIV. Secondary outcomes included agreements with pH, sampling success rates and pain. RESULTS: The agreement between ABG and v-TAC/venous PaCO2 was assessed for 119 matched sampling episodes and 105 between ABG and CBG. Close agreement was shown for v-TAC (mean difference (SD) 0.01 (0.5) kPa), but not for CBG (-0.75 (0.69) kPa) or VBG (+1.00 (0.90) kPa). Longitudinal data for 32 patients started on NIV showed the closest agreement for ABG and v-TAC (R2=0.61). v-TAC sampling had the highest first-time success rate (88%) and was less painful than arterial (p<0.0001). CONCLUSION: Mathematical arterialisation of venous samples was easier to obtain and less painful than ABG sampling. Results showed close agreement for PaCO2 and pH and tracked well longitudinally such that the v-TAC method could replace routine ABG testing to recognise and monitor patients with hypercapnic respiratory failure. TRIAL REGISTRATION NUMBER: NCT04072848; www. CLINICALTRIALS: gov.


Asunto(s)
Dióxido de Carbono , Insuficiencia Respiratoria , Humanos , Adulto , Estudios Longitudinales , Reproducibilidad de los Resultados , Insuficiencia Respiratoria/diagnóstico , Insuficiencia Respiratoria/etiología , Insuficiencia Respiratoria/terapia , Estudios de Cohortes
2.
BMJ Case Rep ; 14(12)2021 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-34972777

RESUMEN

We present the case of a 65-year-old woman diagnosed with rapid eye movement sleep behaviour disorder (REMBD) based on typical symptoms and confirmed with an inpatient polysomnogram. She was prescribed clonazepam and later temazepam but continued to have intrusive symptoms. She subsequently recalled that the onset of dream enactment coincided with starting high-dose omeprazole for acid reflux. With this insight, she stopped the omeprazole. Within days, the dream enactment and nocturnal movements subsided. She stopped taking the temazepam and was symptom free for a few months. However, she was started on lansoprazole for recurrent dyspepsia. Once again she experienced violent movements in sleep. This is the first time an association between proton pump inhibitors (PPIs) and REMBD has been reported. PPIs have many effects on the central nervous system and should be considered as a possible provoking factor in people presenting with REMBD.


Asunto(s)
Reflujo Gastroesofágico , Trastorno de la Conducta del Sueño REM , 2-Piridinilmetilsulfinilbencimidazoles , Anciano , Femenino , Humanos , Lansoprazol , Omeprazol , Inhibidores de la Bomba de Protones , Trastorno de la Conducta del Sueño REM/tratamiento farmacológico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...