Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
JMIR Res Protoc ; 12: e47079, 2023 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-37104709

RESUMEN

BACKGROUND: Living with HIV is a risk factor for severe acute COVID-19, but it is unknown whether it is a risk factor for long COVID. OBJECTIVE: This study aims to characterize symptoms, sequelae, and cognition formally and prospectively 12 months following SARS-CoV-2 infection in people living with HIV compared with people without HIV. People with no history of SARS-CoV-2 infection, both with and without HIV, are enrolled as controls. The study also aims to identify blood-based biomarkers or patterns of immune dysregulation associated with long COVID. METHODS: This prospective observational cohort study enrolled participants into 1 of the following 4 study arms: people living with HIV who had SARS-CoV-2 infection for the first time <4 weeks before enrollment (HIV+COVID+ arm), people without HIV who had SARS-CoV-2 infection for the first time within 4 weeks of enrollment (HIV-COVID+ arm), people living with HIV who believed they never had SARS-CoV-2 infection (HIV+COVID- arm), and people without HIV who believed they never had SARS-CoV-2 infection (HIV-COVID- arm). At enrollment, participants in the COVID+ arms recalled their symptoms, mental health status, and quality of life in the month before having SARS-CoV-2 infection via a comprehensive survey administered by telephone or on the web. All participants completed the same comprehensive survey 1, 2, 4, 6, and 12 months after post-acute COVID-19 symptom onset or diagnosis, if asymptomatic, (COVID+ arms) or after enrollment (COVID- arms) on the web or by telephone. In total, 11 cognitive assessments were administered by telephone at 1 and 4 months after symptom onset (COVID+ arms) or after enrollment (COVID- arms). A mobile phlebotomist met the participants at a location of their choice for height and weight measurements, orthostatic vital signs, and a blood draw. Participants in the COVID+ arms donated blood 1 and 4 months after COVID-19, and participants in the COVID- arms donated blood once or none. Blood was then shipped overnight to the receiving study laboratory, processed, and stored. RESULTS: This project was funded in early 2021, and recruitment began in June 2021. Data analyses will be completed by summer 2023. As of February 2023, a total of 387 participants were enrolled in this study, with 345 participants having completed enrollment or baseline surveys together with at least one other completed study event. The 345 participants includes 76 (22%) HIV+COVID+, 121 (35.1%) HIV-COVID+, 78 (22.6%) HIV+COVID-, and 70 (20.3%) HIV-COVID- participants. CONCLUSIONS: This study will provide longitudinal data to characterize COVID-19 recovery over 12 months in people living with and without HIV. Additionally, this study will determine whether biomarkers or patterns of immune dsyregulation associate with decreased cognitive function or symptoms of long COVID. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/47079.

2.
Clin Infect Dis ; 76(3): e416-e425, 2023 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-35607802

RESUMEN

BACKGROUND: Patterns of shedding replication-competent severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in severe or critical COVID-19 are not well characterized. We investigated the duration of replication-competent SARS-CoV-2 shedding in upper and lower airway specimens from patients with severe or critical coronavirus disease 2019 (COVID-19). METHODS: We enrolled patients with active or recent severe or critical COVID-19 who were admitted to a tertiary care hospital intensive care unit (ICU) or long-term acute care hospital (LTACH) because of COVID-19. Respiratory specimens were collected at predefined intervals and tested for SARS-CoV-2 using viral culture and reverse transcription-quantitative polymerase chain reaction (RT-qPCR). Clinical and epidemiologic metadata were reviewed. RESULTS: We collected 529 respiratory specimens from 78 patients. Replication-competent virus was detected in 4 of 11 (36.3%) immunocompromised patients up to 45 days after symptom onset and in 1 of 67 (1.5%) immunocompetent patients 10 days after symptom onset (P = .001). All culture-positive patients were in the ICU cohort and had persistent or recurrent symptoms of COVID-19. Median time from symptom onset to first specimen collection was 15 days (range, 6-45) for ICU patients and 58.5 days (range, 34-139) for LTACH patients. SARS-CoV-2 RNA was detected in 40 of 50 (80%) ICU patients and 7 of 28 (25%) LTACH patients. CONCLUSIONS: Immunocompromise and persistent or recurrent symptoms were associated with shedding of replication-competent SARS-CoV-2, supporting the need for improving respiratory symptoms in addition to time as criteria for discontinuation of transmission-based precautions. Our results suggest that the period of potential infectiousness among immunocompetent patients with severe or critical COVID-19 may be similar to that reported for patients with milder disease.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , ARN Viral/genética , Sistema Respiratorio , Manejo de Especímenes , Esparcimiento de Virus
3.
J Clin Virol ; 147: 105080, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35086043

RESUMEN

BACKGROUND: Viral diversity presents an ongoing challenge for diagnostic tests, which need to accurately detect all circulating variants. The Abbott Global Surveillance program monitors severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) variants and their impact on diagnostic test performance. OBJECTIVES: To evaluate the capacity of Abbott molecular, antigen, and serologic assays to detect circulating SARS-CoV-2 variants, including all current variants of concern (VOC): B.1.1.7 (alpha), B.1.351 (beta), P.1 (gamma) and B.1.617.2 (delta). STUDY DESIGN: Dilutions of variant virus cultures (B.1.1.7, B.1.351, B.1.429, B.1.526.1, B.1.526.2, B.1.617.1, B.1.617.2, P.1, R.1 and control isolate WA1) and a panel of N = 248 clinical samples from patients with sequence confirmed variant infections (B.1.1.7, B.1.351, B.1.427, B.1.429, B.1.526, B.1.526.1, B.1.526.2, P.1, P.2, R.1) were evaluated on at least one assay: Abbott ID NOW COVID-19, m2000 RealTime SARS-CoV-2, Alinity m SARS-CoV-2, and Alinity m Resp-4-Plex molecular assays; the BinaxNOW COVID-19 Ag Card and Panbio COVID-19 Ag Rapid Test Device; and the ARCHITECT/Alinity i SARS-CoV-2 IgG and AdviseDx IgM assays, Panbio COVID-19 IgG assay, and ARCHITECT/Alinity i AdviseDx SARS-CoV-2 IgG II assay. RESULTS: Consistent with in silico predictions, each molecular and antigen assay detected VOC virus cultures with equivalent sensitivity to the WA1 control strain. Notably, 100% of all tested variant patient specimens were detected by molecular assays (N = 197 m2000, N = 88 Alinity m, N = 99 ID NOW), and lateral flow assays had a sensitivity of >94% for specimens with genome equivalents (GE) per device above 4 log (85/88, Panbio; 54/57 Binax). Furthermore, Abbott antibody assays detected IgG and IgM in 94-100% of sera from immune competent B.1.1.7 patients 15-26 days after symptom onset. CONCLUSIONS: These data confirm variant detection for 11 SARS-CoV-2 assays, which is consistent with each assay target region being highly conserved. Importantly, alpha, beta, gamma, and delta VOCs were detected by molecular and antigen assays, indicating that these tests may be suitable for widescale use where VOCs predominate.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Antivirales , Humanos , Sensibilidad y Especificidad , Pruebas Serológicas
4.
Biol Proced Online ; 23(1): 10, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-34058978

RESUMEN

We investigated nasopharyngeal microbial community structure in COVID-19-positive and -negative patients. High-throughput 16S ribosomal RNA gene amplicon sequencing revealed significant microbial community structure differences between COVID-19-positive and -negative patients. This proof-of-concept study demonstrates that: (1) nasopharyngeal microbiome communities can be assessed using collection samples already collected for SARS-CoV-2 testing (viral transport media) and (2) SARS-CoV-2 infection is associated with altered dysbiotic microbial profiles which could be a biomarker for disease progression and prognosis in SARS-CoV-2.

6.
J Clin Virol ; 139: 104822, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33930698

RESUMEN

BACKGROUND: In HIV-1-exposed infants, nucleic acid testing (NAT) is required to diagnose infection since passively transferred maternal antibodies preclude antibody testing. The sensitivity of clinical NAT assays is lowered with infant antiretroviral prophylaxis and, with empiric very early antiretroviral treatment of high-risk infants, thereby impacting early infant diagnosis. Similarly, adult HIV-1 infections acquired under pre-exposure prophylaxis may occur at low levels, with undetectable plasma viremia and indeterminate antibody tests, for which HIV-1 DNA testing maybe a useful adjunct. Cell-associated HIV-1 DNA concentrations are also used to monitor HIV-1 persistence in viral reservoirs with relevance to HIV-1 cure therapeutics, particularly in perinatal infections. OBJECTIVES: We clinically validated an HIV-1 DNA quantitative assay using droplet digital PCR (ddPCR), across different HIV-1 subtypes. STUDY DESIGN: The analytical sensitivity and specificity of an HIV-1 DNA ddPCR assay was determined using serial dilutions of a plasmid containing HIV-1 LTR-gag spiked into peripheral blood mononuclear cells (PBMCs), with MOLT-4 cells or PBMCs infected with different HIV-1 subtypes (A, B and C), and U1 cells spiked into PBMCs. Inter- and intra-run variability were used to determine assay precision. RESULTS: The HIV-1 LTR-gag ddPCR assay was reliable and reproducible, and exhibited high analytical specificity with sensitivity to near single copy level, across multiple HIV-1 subtypes, and a limit of detection of 4.09 copies/million PBMCs. CONCLUSIONS: This assay has applications for detecting occult HIV-1-infection in the setting of combination and long-acting regimens used for HIV-1 prevention, across different HIV-1 subtypes, in infants and adults, and in HIV-1 cure interventions.


Asunto(s)
Infecciones por VIH , VIH-1 , Antirretrovirales/uso terapéutico , ADN Viral/genética , Infecciones por VIH/diagnóstico , Infecciones por VIH/tratamiento farmacológico , VIH-1/genética , Humanos , Leucocitos Mononucleares , Reacción en Cadena de la Polimerasa , Sensibilidad y Especificidad , Carga Viral
7.
Viruses ; 12(12)2020 12 17.
Artículo en Inglés | MEDLINE | ID: mdl-33348705

RESUMEN

The National Institute of Allergy and Infectious Diseases (NIAID) Virology Quality Assurance (VQA) established a robust proficiency testing program for Sanger sequencing (SS)-based HIV-1 drug resistance (HIVDR) testing in 2001. While many of the lessons learned during the development of such programs may also apply to next generation sequencing (NGS)-based HIVDR assays, challenges remain for the ongoing evaluation of NGS-based testing. These challenges include a proper assessment of assay accuracy and the reproducibility of low abundance variant detection, intra- and inter-assay performance comparisons among laboratories using lab-defined tests, and different data analysis pipelines designed for NGS. In collaboration with the World Health Organization (WHO) Global HIVDR Laboratory Network and the Public Health Agency of Canada, the Rush VQA program distributed archived proficiency testing panels to ten laboratories to evaluate internally developed NGS assays. Consensus FASTA files were submitted using 5%, 10%, and 20% variant detection thresholds, and scored based on the same criteria used for SS. This small study showed that the SS External Quality Assurance (EQA) approach can be used as a transitional strategy for using NGS to generate SS-like data and for ongoing performance while using NGS data from the same quality control materials to further evaluate NGS assay performance.


Asunto(s)
Farmacorresistencia Viral , Genoma Viral , Genotipo , Infecciones por VIH/virología , VIH-1/efectos de los fármacos , VIH-1/fisiología , Secuencia de Bases , Secuencia de Consenso , Infecciones por VIH/tratamiento farmacológico , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Análisis de Secuencia de ADN
8.
Viruses ; 12(7)2020 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-32605062

RESUMEN

Next-generation sequencing (NGS) is increasingly used for HIV-1 drug resistance genotyping. NGS methods have the potential for a more sensitive detection of low-abundance variants (LAV) compared to standard Sanger sequencing (SS) methods. A standardized threshold for reporting LAV that generates data comparable to those derived from SS is needed to allow for the comparability of data from laboratories using NGS and SS. Ten HIV-1 specimens were tested in ten laboratories using Illumina MiSeq-based methods. The consensus sequences for each specimen using LAV thresholds of 5%, 10%, 15%, and 20% were compared to each other and to the consensus of the SS sequences (protease 4-99; reverse transcriptase 38-247). The concordance among laboratories' sequences at different thresholds was evaluated by pairwise sequence comparisons. NGS sequences generated using the 20% threshold were the most similar to the SS consensus (average 99.6% identity, range 96.1-100%), compared to 15% (99.4%, 88.5-100%), 10% (99.2%, 87.4-100%), or 5% (98.5%, 86.4-100%). The average sequence identity between laboratories using thresholds of 20%, 15%, 10%, and 5% was 99.1%, 98.7%, 98.3%, and 97.3%, respectively. Using the 20% threshold, we observed an excellent agreement between NGS and SS, but significant differences at lower thresholds. Understanding how variation in NGS methods influences sequence quality is essential for NGS-based HIV-1 drug resistance genotyping.


Asunto(s)
Farmacorresistencia Viral/genética , Técnicas de Genotipaje/métodos , VIH-1/genética , Secuenciación de Nucleótidos de Alto Rendimiento , Laboratorios/normas , Variación Genética , Genotipo , Transcriptasa Inversa del VIH/genética , VIH-1/efectos de los fármacos , VIH-1/enzimología , Mutación , Péptido Hidrolasas/genética , Análisis de Secuencia de ADN
9.
Viruses ; 12(5)2020 05 18.
Artículo en Inglés | MEDLINE | ID: mdl-32443529

RESUMEN

Next-generation sequencing (NGS) is likely to become the new standard method for HIV drug resistance (HIVDR) genotyping. Despite the significant advances in the development of wet-lab protocols and bioinformatic data processing pipelines, one often-missing critical component of an NGS HIVDR assay for clinical use is external quality assessment (EQA). EQA is essential for ensuring assay consistency and laboratory competency in performing routine biomedical assays, and the rollout of NGS HIVDR tests in clinical practice will require an EQA. In September 2019, the 2nd International Symposium on NGS HIVDR was held in Winnipeg, Canada. It convened a multidisciplinary panel of experts, including research scientists, clinicians, bioinformaticians, laboratory biologists, biostatisticians, and EQA experts. A themed discussion was conducted on EQA strategies towards such assays during the symposium. This article describes the logistical challenges identified and summarizes the opinions and recommendations derived from these discussions, which may inform the development of an inaugural EQA program for NGS HIVDR in the near future.


Asunto(s)
Farmacorresistencia Viral/genética , VIH-1/genética , Secuenciación de Nucleótidos de Alto Rendimiento/normas , Garantía de la Calidad de Atención de Salud , Análisis de Secuencia de ARN/normas , Congresos como Asunto , Pruebas Diagnósticas de Rutina/normas , Genotipo , Infecciones por VIH/virología , Garantía de la Calidad de Atención de Salud/organización & administración
10.
Sci Rep ; 10(1): 1634, 2020 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-32005884

RESUMEN

Next generation sequencing (NGS) is a trending new standard for genotypic HIV-1 drug resistance (HIVDR) testing. Many NGS HIVDR data analysis pipelines have been independently developed, each with variable outputs and data management protocols. Standardization of such analytical methods and comparison of available pipelines are lacking, yet may impact subsequent HIVDR interpretation and other downstream applications. Here we compared the performance of five NGS HIVDR pipelines using proficiency panel samples from NIAID Virology Quality Assurance (VQA) program. Ten VQA panel specimens were genotyped by each of six international laboratories using their own in-house NGS assays. Raw NGS data were then processed using each of the five different pipelines including HyDRA, MiCall, PASeq, Hivmmer and DEEPGEN. All pipelines detected amino acid variants (AAVs) at full range of frequencies (1~100%) and demonstrated good linearity as compared to the reference frequency values. While the sensitivity in detecting low abundance AAVs, with frequencies between 1~20%, is less a concern for all pipelines, their specificity dramatically decreased at AAV frequencies <2%, suggesting that 2% threshold may be a more reliable reporting threshold for ensured specificity in AAV calling and reporting. More variations were observed among the pipelines when low abundance AAVs are concerned, likely due to differences in their NGS read quality control strategies. Findings from this study highlight the need for standardized strategies for NGS HIVDR data analysis, especially for the detection of minority HIVDR variants.


Asunto(s)
Farmacorresistencia Viral/genética , VIH-1/genética , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Aminoácidos/genética , Variación Genética/genética , Genotipo , Infecciones por VIH/virología , Seropositividad para VIH , Humanos , Sensibilidad y Especificidad
11.
J Virol Methods ; 261: 91-97, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30125614

RESUMEN

BACKGROUND: Commercially-available kits for HIV-1 detection include instructions for detecting HIV-1 in plasma and DBS, but don't support other specimen types. OBJECTIVES: Show quantitative stability of HIV-1 total nucleic acid (TNA) in blood and improved HIV-1 detection in alternative specimen types. STUDY DESIGN: Whole blood and DBS specimens, tested as part of an external quality assurance program for qualitative HIV-1 detection, were used to evaluated error rates (false negative [FN], false positive [FP] and indeterminant [IND] results) across assays (internally developed [IH], Roche Amplicor [RA], and Roche TaqMan Qual [TQ]) and specimen types (frozen whole blood [BLD], DBS and cell pellets [PEL]). A modified Roche TaqMan HIV-1 assay was used to quantify HIV-1 TNA. RESULTS: Significantly higher error rates were noted in DBS across all of the assays (4% vs. 0% for DBS and PEL, IH, p = 0.005; 4% vs. 0.1% for DBS and PEL, RA, p < 0.001; 10% vs. 1% for DBS and PEL or BLD, TQ, p < 0.001). HIV TNA concentration is stable in BLD (day 1 vs. day 10, p = 0.39) and higher than DBS (p < 0.001). CONCLUSIONS: Transporting refrigerated whole blood for centralized processing into alternative specimen types will improve the sensitivitiy of HIV-1 detection in samples with low virus loads.


Asunto(s)
Infecciones por VIH/diagnóstico , VIH-1/aislamiento & purificación , ARN Viral/análisis , Manejo de Especímenes/métodos , Errores Diagnósticos , VIH-1/genética , ARN Viral/genética , Sensibilidad y Especificidad
12.
J Clin Microbiol ; 56(6)2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29618501

RESUMEN

The National Institute of Allergy and Infectious Diseases (NIAID) AIDS Clinical Trials Group (ACTG) stores specimens from its clinical trials in a biorepository and permits the use of these specimens for nonprotocol exploratory studies, once the studies for the original protocol are concluded. We sought to assess the comparability of the data generated from real-time HIV-1 RNA testing during two clinical trials with the data generated from the retesting of different aliquots of the same samples after years of storage at -80°C. Overall, there was 92% agreement in the data generated for 1,570 paired samples (kappa statistic = 0.757; 95% confidence interval [CI], 0.716 to 0.797), where samples were tested in one laboratory using the microwell plate (MWP) version of the Roche HIV-1 Monitor test within 1 to 37 days of collection and retested in another laboratory using the Cobas version of the assay after a median of 6.7 years of storage (range, 5.7 to 8.6 years). Historical external quality control data submitted to the NIAID Virology Quality Assurance program (VQA) by client laboratories using the same two versions of the Monitor assay were used to differentiate between systematic differences in the assays to evaluate the stability of HIV-1 RNA in the stored samples. No significant loss of RNA was noted in samples containing either a low concentration (<50 copies/ml) or a high concentration (≥50 copies/ml) of HIV-1 RNA (P = 0.10 and P = 0.90, respectively) regardless of the time in storage. These data confirm the quality of the plasma samples in the ACTG biorepository following long-term storage.


Asunto(s)
VIH-1/genética , Laboratorios , Control de Calidad , Estabilidad del ARN , ARN Viral/genética , Manejo de Especímenes/normas , Bancos de Muestras Biológicas , Análisis de Datos , Infecciones por VIH/sangre , Infecciones por VIH/virología , Humanos , Juego de Reactivos para Diagnóstico , Sensibilidad y Especificidad , Carga Viral
13.
Clin Infect Dis ; 67(11): 1712-1719, 2018 11 13.
Artículo en Inglés | MEDLINE | ID: mdl-29590326

RESUMEN

Background: Herpes zoster (HZ) risk is increased in human immunodeficiency virus (HIV)-infected persons. Live attenuated zoster vaccine (ZV) reduces HZ incidence and severity in adults; safety and immunogenicity data in HIV-infected adults are limited. Methods: We conducted a randomized, double-blind, placebo-controlled trial in HIV-infected adults virally suppressed on antiretroviral therapy (ART). Participants, stratified by CD4+ count (200-349 or ≥350 cells/µL), were randomized 3:1 to receive ZV or placebo on day 0 and week 6. The primary endpoint was serious adverse event or grade 3/4 signs/symptoms within 6 weeks after each dose. Immunogenicity (varicella zoster virus [VZV]-specific glycoprotein enzyme-linked immunosorbent assay and interferon-γ enzyme-linked immunospot assay responses) was assessed at 6 and 12 weeks postvaccination. Results: Of 395 participants (296 ZV vs 99 placebo), 84% were male, 47% white, 29% black, and 22% Hispanic; median age was 49 years. Safety endpoints occurred in 15 ZV and 2 placebo recipients (5.1% [95% confidence interval {CI}, 2.9%-8.2%] vs 2.1% [95% CI, .3%-7.3%]; P = .26). Injection site reactions occurred in 42% of ZV (95% CI, 36.3%-47.9%) vs 12.4% of placebo recipients (95% CI, 6.6%-20.6%) (P < .001). Week 12 median natural log VZV antibody titer was higher for ZV (6.30 [Q1, Q3, 5.64, 6.96]) vs placebo (5.48 [Q1, Q3, 4.63, 6.44]; P < .001) overall and in the high CD4+ stratum (P = .003). VZV antibody titers were similar after 1 or 2 ZV doses. Polymerase chain reaction-confirmed HZ occurred in 2 participants (1 ZV; 1 placebo); none was vaccine strain related. Conclusions: Two doses of ZV in HIV-infected adults suppressed on ART with CD4+ counts ≥200 cells/µL were safe and immunogenic. Clinical Trials Registration: NCT00851786.


Asunto(s)
Terapia Antirretroviral Altamente Activa , Infecciones por VIH/inmunología , Vacuna contra el Herpes Zóster/inmunología , Inmunogenicidad Vacunal , Respuesta Virológica Sostenida , Adulto , Anticuerpos Antivirales/sangre , Recuento de Linfocito CD4 , Método Doble Ciego , Ensayo de Immunospot Ligado a Enzimas , Femenino , Infecciones por VIH/tratamiento farmacológico , Herpesvirus Humano 3 , Humanos , Masculino , Persona de Mediana Edad
14.
Int J Polym Mater ; 66(11): 569-576, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28736462

RESUMEN

Sequential release of drugs aligned with the phases of tissue healing could reduce scarring. To achieve this aim, layered film devices comprising cellulose acetate phthalate (CAP) and Pluronic F-127 (Pluronic) were loaded with ketoprofen, quercetin, and pirfenidone. Citrate plasticizers were added to impart flexibility. Release of two or three drugs in sequence over several days was obtained for all multilayered devices tested. Mechanical analysis showed that elongation increased and modulus decreased with increasing plasticizer content. Release profiles can be tailored by order of layers, plasticizer concentration, and drug loaded, making CAP-Pluronic an appealing system for inhibiting scar tissue formation.

15.
J Bioact Compat Polym ; 31(4): 323-333, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27821905

RESUMEN

Formation of scar tissue may be reduced or prevented if wounds were locally treated with a combination of molecules tuned to the different healing phases, guiding tissue regeneration along a scar free path. To this end, drug delivery devices made of cellulose acetate phthalate and Pluronic F-127 were loaded with either quercetin or pirfenidone and plasticized with either triethyl citrate (TEC) or tributyl citrate (TBC). Quercetin inhibits oxidative stress, and pirfenidone has been shown to reduce production of pro-inflammatory and fibrogenic molecules. The combined effects of drug and plasticizer on erosion, release, and mechanical properties of the drug delivery films were investigated. TEC-plasticized films containing quercetin released drug at a slower rate than did TBC films. Pirfenidone-loaded films released drug at a faster rate than erosion occurred for both types of plasticizers. Higher plasticizer contents of both TEC and TBC increased the elongation and decreased the elastic modulus. In contrast, increased pirfenidone loading in both TEC and TBC films resulted in a significantly higher modulus, an anti-plasticizer effect. Adding pirfenidone significantly decreased elongation for all film types, but quercetin-loaded samples had significantly greater elongation with increasing drug content. Films containing quercetin elongated more than did pirfenidone-loaded films. Quercetin is over 1.5 times larger than pirfenidone, has water solubility over 12 times lower, and has 6 times more bonding sites than pirfenidone. These differences affected how the two drugs interacted with cellulose acetate phthalate and Pluronic F-127 and thereby determined polymer properties. Drug release, erosion, and mechanical properties of association polymer films can be tailored by the characteristics of the drugs and plasticizers included in the system.

16.
J Clin Microbiol ; 54(4): 902-11, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26763968

RESUMEN

Although a number of PCR-based quantitative assays for measuring HIV-1 persistence during suppressive antiretroviral therapy (ART) have been reported, a simple, sensitive, reproducible method is needed for application to large clinical trials. We developed novel quantitative PCR assays for cell-associated (CA) HIV-1 DNA and RNA, targeting a highly conserved region in HIV-1pol, with sensitivities of 3 to 5 copies/1 million cells. We evaluated the performance characteristics of the assays using peripheral blood mononuclear cells (PBMCs) from 5 viremic patients and 20 patients receiving effective ART. Total and resting CD4(+)T cells were isolated from a subset of patients and tested for comparison with PBMCs. The estimated standard deviations including interassay variability and intra-assay variability of the assays were modest, i.e., 0.15 and 0.10 log10copies/10(6)PBMCs, respectively, for CA HIV-1 DNA and 0.40 and 0.19 log10copies/10(6)PBMCs for CA HIV-1 RNA. Testing of longitudinally obtained PBMC samples showed little variation for either viremic patients (median fold differences of 0.80 and 0.88 for CA HIV-1 DNA and RNA, respectively) or virologically suppressed patients (median fold differences of 1.14 and 0.97, respectively). CA HIV-1 DNA and RNA levels were strongly correlated (r= 0.77 to 1;P= 0.0001 to 0.037) for assays performed using PBMCs from different sources (phlebotomy versus leukapheresis) or using total or resting CD4(+)T cells purified by either bead selection or flow cytometric sorting. Their sensitivity, reproducibility, and broad applicability to small numbers of mononuclear cells make these assays useful for observational and interventional studies that examine longitudinal changes in the numbers of HIV-1-infected cells and their levels of transcription.


Asunto(s)
ADN Viral/análisis , Infecciones por VIH/virología , VIH-1/aislamiento & purificación , Leucocitos Mononucleares/virología , ARN Viral/análisis , Carga Viral/métodos , Adulto , ADN Viral/genética , Femenino , VIH-1/genética , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , ARN Viral/genética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
J Clin Microbiol ; 53(8): 2659-66, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26063861

RESUMEN

Discrepancies between HIV-1 RNA results assayed by different FDA-approved platforms have been reported. Plasma samples collected from 332 randomly selected clinical trial participants during the second year of antiretroviral treatment were assayed with three FDA-approved platforms: UltraSensitive Roche Amplicor Monitor, v1.5 (Monitor), the Abbott RealTime HIV-1 test on the m2000 system (Abbott), and the Roche TaqMan HIV-1 test, v2.0 (TaqMan). Samples from 61 additional participants with confirmed HIV-1 RNA levels of >50 copies/ml during trial follow-up were also included. Endpoints were HIV-1 RNA quantification of ≤50 copies/ml versus >50 copies/ml at an individual-sample level (primary) and determination of confirmed virologic failure (VF) from longitudinal samples. A total of 389 participants had results obtained from all assays on at least one sample (median = 6). Proportions of results of >50 copies/ml were 19% (Monitor), 22% (TaqMan), and 25% (Abbott). Despite indication of strong agreement (Cohen's kappa, 0.76 to 0.82), Abbott was more likely to detect HIV-1 RNA levels of >50 copies/ml than Monitor (matched-pair odds ratio [mOR] = 4.2; modified Obuchowski P < 0.001) and TaqMan (mOR = 2.1; P < 0.001); TaqMan was more likely than Monitor (mOR = 2.6; P < 0.001). Despite strong agreement in classifying VF across assay comparisons (kappa, 0.75 to 0.92), at a 50-copies/ml threshold, differences in the probability of VF classification (in the same direction as primary) were apparent (all McNemar's P < 0.007). At a 200-copies/ml VF threshold, no differences between assays were apparent (all P > 0.13). Despite strong agreement among assays, significant differences were observed with respect to detecting HIV-1 RNA levels of >50 copies/ml and identifying VF at the 50-copies/ml threshold. This has important implications for the definition of VF in clinical trials and clinical practice.


Asunto(s)
Infecciones por VIH/virología , VIH-1/aislamiento & purificación , Plasma/virología , ARN Viral/sangre , Carga Viral/métodos , Adolescente , Adulto , Anciano , Antirretrovirales/uso terapéutico , Femenino , Infecciones por VIH/tratamiento farmacológico , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Insuficiencia del Tratamiento , Adulto Joven
18.
J Clin Microbiol ; 50(8): 2737-47, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22692747

RESUMEN

HIV-1 RNA quantitation continues to be extremely important for monitoring patients infected with HIV-1, and a number of assays have been utilized for this purpose. Differences in assay performance with respect to log(10) recovery and HIV-1 subtype specificity have been well documented for commercially available assays, although comparisons are usually limited to one or two assay platforms. Two new FDA-approved assays, the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test (RT) and the Abbott RealTime HIV-1 assay (AR), that utilize real-time PCR have replaced previous HIV-1 RNA platforms. Inadequate detection of some strains of HIV-1 resulted in the addition of a new primer/probe set and the introduction of a second version of the RT assay. In this study, comparisons of assay performance between the different FDA-approved HIV-1 RNA assay platforms (both new and existing) were performed by using validation data that included both well-characterized virus stock and locally collected clinical samples. Laboratories across diverse geographical regions performed the validation testing and submitted data to the Virology Quality Assurance program (VQA) for analysis. Correlation values for clinical sample testing varied across the assay platforms (r = 0.832 to 0.986), and average log(10) recoveries for HIV-1 RNA controls (compared to the nominal value) ranged from -0.215 to 0.181. These data demonstrate the need for use of one assay platform for longitudinal patient monitoring, but the data also reinforce the notion that no one assay is superior and that testing across platforms may be required for discordance reconciliation.


Asunto(s)
Infecciones por VIH/diagnóstico , Infecciones por VIH/virología , VIH-1/aislamiento & purificación , ARN Viral/sangre , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Carga Viral/métodos , Humanos , Garantía de la Calidad de Atención de Salud , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Carga Viral/normas
19.
Clin Infect Dis ; 54 Suppl 4: S273-9, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22544187

RESUMEN

In resource-limited settings, there is increased demand for human immunodeficiency virus type 1 drug resistance testing. Because preservation of plasma specimens is often not feasible in resource-limited settings, use of dried blood spots (DBSs) is being adopted. We used 2 panels of DBSs for genotyping assay validation and proficiency testing in selected laboratories in the World Health Organization laboratory network in 14 countries. An amplification sensitivity of 1000 copies/mL was achieved by 2 laboratories. Reproducibility and accuracy of nucleotide sequence determination and resistance-associated mutation identification from DBSs was similar to that previously determined for plasma. International shipping at ambient temperature had no significant effect on amplification success. These studies indicate that DBS-based genotyping is equally reproducible and reliable, although slightly less sensitive, compared with plasma.


Asunto(s)
Pruebas con Sangre Seca/métodos , Técnicas de Genotipaje/métodos , Infecciones por VIH/sangre , Infecciones por VIH/virología , VIH-1/genética , Pruebas con Sangre Seca/normas , Farmacorresistencia Viral/genética , Genotipo , Técnicas de Genotipaje/normas , Humanos , Laboratorios , Reacción en Cadena de la Polimerasa , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Análisis de Secuencia de ADN , Temperatura , Carga Viral/métodos , Carga Viral/normas , Organización Mundial de la Salud
20.
J Antimicrob Chemother ; 64(1): 33-6, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19403653

RESUMEN

OBJECTIVES: Dried blood spots (DBS) and dried plasma spots (DPS) are considered convenient alternatives to serum and plasma for HIV drug resistance testing in resource-limited settings. We sought to investigate how extreme conditions could affect the short-term ability to amplify and genotype HIV from DBS. METHODS: A panel of six matched DPS/DBS was generated using blood collected from HIV-infected donors. Replicate cards were prepared in 903 filter paper using 50 microL of blood and stored at either -20 degrees C or at 37 degrees C/100% humidity. Nucleic acids were extracted at baseline and after 1, 2, 8 and 16 weeks of storage and were amplified and sequenced using an in-house RT-nested PCR method or the ViroSeq assay. RESULTS: HIV-1 pol was successfully amplified in all DBS/DPS at baseline and in those stored for up to 16 weeks at -20 degrees C by the in-house assay. In contrast, amplification was rapidly lost during storage at 37 degrees C/100% humidity with only 6/6 and 4/6 DBS specimens amplifiable by the in-house assay at weeks 1 and 2, respectively. Similarly, only two DPS stored at 37 degrees C/100% humidity were amplified by the in-house assay at week 1. CONCLUSIONS: We show that resistance testing from DBS and DPS is severely compromised after 2 and 1 weeks of storage at 37 degrees C/100% humidity with desiccant, respectively. These findings underscore the importance of temperature and humidity for the efficient genotyping of HIV-1 from DBS and DPS, and reiterate the need to rapidly transport specimens from collection sites to locations that have appropriate storage conditions such as -20 degrees C.


Asunto(s)
Sangre/virología , Desecación , Farmacorresistencia Viral , VIH-1/genética , Plasma/virología , Manejo de Especímenes/métodos , Genotipo , VIH-1/aislamiento & purificación , Humanos , Humedad , Reacción en Cadena de la Polimerasa/métodos , ARN Viral/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Temperatura , Productos del Gen pol del Virus de la Inmunodeficiencia Humana/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...