Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Intern Med ; 55(8): 929-33, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27086807

RESUMEN

Congenital coronary artery fistulas (CAFs) are rare and asymptomatic, although symptomatic CAFs should be treated with percutaneous intervention or surgery. A 62-year-old woman developed bilateral coronary-to-pulmonary artery fistulas resulting in exertional chest pain. We herein report the successful use of trans-catheter closure of a coronary artery-to-pulmonary artery fistula, which lead to the coronary steal phenomenon, using an Amplatzer vascular plug with the trans-radial approach. After the procedure, the patient remained asymptomatic.


Asunto(s)
Fístula Arterio-Arterial/congénito , Fístula Arterio-Arterial/cirugía , Anomalías de los Vasos Coronarios/cirugía , Arteria Pulmonar/anomalías , Arteria Pulmonar/cirugía , Procedimientos Quirúrgicos Vasculares/métodos , Administración Cutánea , Dolor en el Pecho , Femenino , Humanos , Persona de Mediana Edad , Dispositivo Oclusor Septal
2.
Medicine (Baltimore) ; 95(6): e2704, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26871806

RESUMEN

Stent fracture is an uncommon complication of drug-eluting stent implantation, but it has a clinical significance because of its potential association with adverse cardiac events such as in-stent restenosis, target lesion revascularization, and stent thrombosis. Multiple stent fractures account for a small proportion, but they may lead to more serious complications. Newer generation drug-eluting stents are designed for improved safety and efficacy compared with early generation drug-eluting stents. Multiple stent fractures after newer generation drug-eluting stent implantation are a rare case.We report a case of 25-year-old male who presented with acute myocardial infarction caused by multiple stent fractures after everolimus-eluting stents implantation and was treated by balloon angioplasty.Physicians should be aware of the possibility of multiple stent fractures even after newer generation drug-eluting stent implantation.


Asunto(s)
Stents Liberadores de Fármacos/efectos adversos , Everolimus/administración & dosificación , Inmunosupresores/administración & dosificación , Infarto del Miocardio/etiología , Falla de Prótesis/efectos adversos , Adulto , Humanos , Masculino , Infarto del Miocardio/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA