Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Technol Health Care ; 32(4): 2081-2090, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38393932

RESUMEN

OBJECTIVE: In order to improve nursing quality management and protect patient medical safety, it is necessary to change the default mode and completely integrate information technology and nursing quality control utilising lean management. METHODS: A database was created, the nurse quality control scoring standard was entered into the computer and after the inspection, and various inspection reports were entered into the computer to precisely and promptly preserve data. The computer was then utilised to precisely assess the intensity and quality of nursing work, compute, count, and analyse the stored data, output the quality of nursing work in each department as a report, and adopt lean management for the gathered issues. RESULTS: To reach the objective of raising nursing quality, data analysis makes it simple to identify flaws and consistently strengthen the weak points. In order to create an information-based nursing quality control system with a simple and effective method as well as results that are scientific and objective, lean management is brought into the construction process.


Asunto(s)
Aprendizaje Profundo , Control de Calidad , Humanos , Gestión de la Calidad Total
2.
Front Cardiovasc Med ; 9: 984087, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36386298

RESUMEN

Background and aims: Aortic dissection (AD) is a cardiovascular emergency with degeneration of the aortic media. Mounting evidence indicates obstructive sleep apnea (OSA) as an independent risk factor for AD development with unknown mechanisms. This study aims to establish a stable murine model of OSA-related AD (OSA-AD) and uncover the potential changes in gene transcripts in OSA-AD. Materials and methods: ApoE-/- mice were exposed to the chronic intermittent hypoxia (CIH) system combined with Ang II administration to establish the OSA-AD model. Pathological staining was performed to exhibit the physiological structure of the mouse aorta. The SBC mouse ceRNA microarray was used to identify significantly differentially expressed (DE) mRNAs, DE long-non-coding RNAs (DElncRNAs), and DE circular RNAs (DEcircRNAs) in OSA-AD tissues. Subsequently, bioinformatics analysis, including Gene Ontology (GO), Kyoto Encyclopedia of Genes and Genome (KEGG), and protein-protein interaction (PPI) analyses, were performed to evaluate the function of the significantly differentially expressed transcripts (DETs). The hub genes were confirmed using quantitative real-time polymerase chain reaction (qRT-PCR). Results: ApoE-/- mice exposed to CIH and Ang II showed a high ratio of aortic accident (73.33%) and significant aortic diameter dilatation (1.96 ± 0.175 mm). A total of 1,742 mRNAs, 2,625 lncRNAs, and 537 circRNAs were identified as DETs (LogFC ≥ 1.5 or ≤ -1.5, P < 0.05). GO and KEGG analyses demonstrated that the differentially expressed mRNAs (DEmRNAs) were most enriched in cell proliferation, migration, apoptosis, inflammation, and hypoxia-related terms, which are closely related to aortic structural homeostasis. The PPI network contained 609 nodes and 934 connections, the hub genes were highlighted with the CytoHubba plugin and confirmed by qRT-PCR in AD tissues. KEGG pathway analysis revealed that the cis-regulated genes of DElncRNAs and circRNAs-host genes were enriched in aortic structural homeostasis-related pathways. Conclusion: Our findings help establish a de novo OSA-AD animal model using ApoE-/- mice. Many DEmRNAs, DElncRNAs, and DEcircRNAs were screened for the first time in OSA-AD tissues. Our findings provide useful bioinformatics data for understanding the molecular mechanism of OSA-AD and developing potential therapeutic strategies for OSA-AD.

3.
RSC Adv ; 8(24): 13301-13309, 2018 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-35542550

RESUMEN

The hydrolysis mechanism and the kinetics of using 2-dinitromethylene-5,5-dinitropyrimidine-4,6-dione (NMP) to prepare the representative insensitive energetic material 1,1-diamino-2,2-dinitroethylene (FOX-7) in a nitric-sulfuric acid system are systematically investigated via a density functional theory (DFT) method. The impact of the co-existing acidic group of HSO4 - as well as the solvent effects of the mixed acids on the hydrolysis of NMP are elucidated and discerned, and the proposed catalysis and promotion of the hydrolysis of NMP with HSO4 - are verified. The HSO4 --catalyzed hydrolysis pathway is more favorable than the direct pathway as well as the H2O-catalyzed hydrolysis, indicating that HSO4 - may be a promising catalyst for the preparation of FOX-7 in a mixed acid system. The present study is expected to provide a better understanding of the hydrolysis of NMP, and will significantly help with better preparation of FOX-7 and other nitro-energetic materials.

4.
Injury ; 48(11): 2485-2495, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28899557

RESUMEN

INTRODUCTION: The mirror imaging 3D printing model can be used a as a reference for anatomical reduction in unilateral lower limb fractures. However, the premise of using mirror technology is that the bilateral lower limb bones are similar enough. Because one side had a fracture, it was impossible to compare this directly to the other side. Usually, surgeons think that the bilateral bones are symmetrical and use mirror technology without judging their symmetry. METHODS: In patients with a unilateral lower limb bone fracture, we measured the long axis and short axis of the three selected transverse sections of the bilateral long bone for comparison to judge the symmetry of the bilateral long bones on CT images. Then, we printed a life-size normal mirror image of the long bone that is similar to the affected side. The model was used as a reference for the anatomical reduction of fractures and preoperative practice. RESULTS: Seventy-eight patients with lower limb bone fracture were included in this study. 24 groups of data were generated according to the same level and same axis. There were significant differences between the short axis of the left and right femoral condyle 5cm from the intercondylar keel (p=0.011), and the short axis of the distal tibia 15cm from the ankle dome (p=0.026). There was no significant difference between the left and right sides in the other 22 groups. Of all of the patients in our research, 3 patients decided to forego the surgical treatment and the operation was performed on the model instead, and the lengths of 2 patients showed deviation in actual operations, preventing anatomical reduction. The remaining 73 patients used the pre-bended plates and screws from preoperative practice in the actual operations, and postoperative X-ray examinations showed that the length of the deviation was within the permissible range. CONCLUSION: The "Comparison of long axis and short axis of three equidistant transverse sections" method makes it easy to judge the symmetry of the bilateral long bones, and prevents the blindness of preoperative planning using the contralateral mirror model directly.


Asunto(s)
Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Imagenología Tridimensional , Extremidad Inferior/diagnóstico por imagen , Modelos Anatómicos , Impresión Tridimensional , Adulto , Anciano , Anciano de 80 o más Años , Placas Óseas , Tornillos Óseos , Femenino , Fijación Interna de Fracturas/instrumentación , Curación de Fractura/fisiología , Fracturas Óseas/fisiopatología , Humanos , Extremidad Inferior/lesiones , Extremidad Inferior/cirugía , Masculino , Persona de Mediana Edad , Medicina de Precisión , Cuidados Preoperatorios , Tomografía Computarizada por Rayos X , Adulto Joven
5.
Chin J Traumatol ; 11(6): 375-9, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19032855

RESUMEN

OBJECTIVE: To explore a classification method which can provide the clinical guidance for internal fixation of tibial fracture. METHODS: The different fractures were fixed according to their mechanical classification. Totally, 71 cases of tibial plateau fracture, tibial proximal fracture, tibial distal fracture and Pilon fracture were analyzed to test this selective principle. RESULTS: All 71 patients were followed up for 6-32 months. The displacement was seldomly observed in cases treated acccording to the classification principle, while some cases against the principle had postoperative displacement. The difference was statistically significant (P less than 0.05). It was proved that there was remarkable correlation between tibial fracture classification, internal fixator and fixation methods. CONCLUSION: Types IIIa3, IIIb1 and IIIb2 fractures without eccentric moment should be fixed with double plates or angle-stable materials combined with locking structure, otherwise displacement may occur.


Asunto(s)
Fijación Interna de Fracturas/métodos , Fracturas de la Tibia/clasificación , Fracturas de la Tibia/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Distribución de Chi-Cuadrado , Niño , Preescolar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA