Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Chin Med Assoc ; 84(5): 550-554, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33770054

RESUMEN

Transthoracic echocardiography (TTE) is noninvasive but can only be performed intermittently during fluoroscopy. In a prior study, we created a transducer holder device to allow for hemodynamic monitoring in the intensive care unit. The current study is the first instance of the use of a three-dimensional (3D)-printed TTE transducer holder, which is easily customized and personalized to a previous transducer holder at relatively low cost and short production time, to enable continuous TTE monitoring during device closure of an atrial septal defect (ASD) and ventricular septal defect (VSD). There were 14 ASD patients and 9 VSD patients scheduled to undergo device closure. The study's real-time TTE monitoring was performed by using a 3D-printed transducer holder over the course of the entire implantation procedure. There were 23 patients who successfully underwent septal closures using the 3D-printed holder that enabled real-time images over the entire procedure. The median duration for real-time TTE guidance was 15 minutes for the ASD and 36 minutes for the VSD and the median fluoroscopy time was 11 minutes for the ASD and 30 minutes for the VSD. One migrating VSD occluder and one case of aortic regurgitation after occluder deployment were noted by real-time TTE monitoring during the procedure. Our novel 3D-printed transducer holder can provide transesophageal echocardiography-like real-time imaging during device closure of an ASD and a VSD and may become a new alternative method in ASD and VSD closures. It can also prevent radiation exposure for the intervention team who would otherwise need to perform TTE during live fluoroscopy.


Asunto(s)
Ecocardiografía , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interventricular/diagnóstico por imagen , Impresión Tridimensional , Transductores , Adolescente , Adulto , Anciano , Niño , Preescolar , Defectos del Tabique Interatrial/fisiopatología , Defectos del Tabique Interventricular/fisiopatología , Humanos , Lactante , Persona de Mediana Edad , Adulto Joven
2.
Cardiovasc Ultrasound ; 18(1): 21, 2020 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-32552906

RESUMEN

AIM: Continuous real-time echocardiographic monitoring is essential for guidance during ASD closure. However, transthoracic echocardiography (TTE) can only be implemented intermittently during fluoroscopy. We evaluate a novel approach to provide real-time imaging during the entire procedure. FINDING: We developed a custom-made TTE monitoring apparatus using artificial hand (AH-TTE) that enables real-time TTE images during atrial septal defect (ASD) closure. Thirty-two patients underwent successful device implantation using AH-TTE monitoring without complications. The median duration for real-time AH-TTE monitoring was 22 min and the median fluoroscopy time was 7.2 min. One case of pericardial effusion and one of transient bradycardia event due to air embolism was detected. All patients had uneventful recoveries. CONCLUSIONS: Our simple and novel monitoring technique with AH-TTE provides TEE-like monitoring and may be a new alternative method for ASD closure. It gives real-time stable TTE images and minimizes radiation exposure for the interventional team during fluoroscopy.


Asunto(s)
Inteligencia Artificial , Ecocardiografía/métodos , Defectos del Tabique Interatrial/cirugía , Monitoreo Intraoperatorio/métodos , Ultrasonografía Intervencional/métodos , Adolescente , Adulto , Cateterismo Cardíaco , Niño , Preescolar , Diseño de Equipo , Femenino , Defectos del Tabique Interatrial/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA