1.
Ophthalmol Retina ; 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38735640

RESUMEN

OBJECTIVE: Isolated retinal neovascularization (IRNV) is a common finding in patients with stage 2 and 3 retinopathy of prematurity (ROP). This study aims to further classify the clinical course and significance of these lesions (previously described as "popcorn" based on clinical appearance) in patients with ROP as visualized with ultra-widefield optical coherence tomography (UWF-OCT). DESIGN: Single center, retrospective case series. PARTICIPANTS: Images were collected from 136 babies in the Oregon Health and Science University neonatal intensive care unit. METHODS: A prototype UWF-OCT device captured en face scans (>140°), which were reviewed for the presence of IRNV along with standard zone, stage, and plus classification. In a cross-sectional analysis we compared demographics and the clinical course of eyes with and without IRNV. Longitudinally, we compared ROP severity using a clinician-assigned vascular severity score (VSS) and compared the risk of progression among eyes with and without IRNV using multivariable logistic regression (MLR). MAIN OUTCOME MEASURES: Differences in clinical demographics and disease progression between patients with and without IRNV. RESULTS: Of the 136 patients, 60 developed stage 2 or worse ROP during their disease course, 22 of whom had IRNV visualized on UWF-OCT (37%). On average, patients with IRNV had lower birth weights (BW) (660.1g vs 916.8g, p = 0.001), gestational age (GA) (24.9 vs 26.1 weeks, p = 0.01), and were more likely to present with ROP in zone I (63.4% vs 15.8%, p < 0.001). They were also more likely to progress to stage 3 (68.2% vs 13.2%, p < 0.001) and receive treatment (54.5% vs 15.8%, p = 0.002). Eyes with IRNV had a higher peak VSS (5.61 vs 3.73, p < 0.001) and averaged a higher VSS throughout their disease course. On MLR, IRNV was independently associated with progression to stage 3 (p = 0.02) and requiring treatment (p = 0.03), controlling for GA, BW, and initial zone 1 disease. CONCLUSION: In this single center study, we found that IRNV occurs in higher risk babies and was an independent risk factor for ROP progression and treatment. These findings may have implications for OCT-based ROP classifications in the future.

2.
Biomed Opt Express ; 15(2): 1059-1073, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38404311

RESUMEN

A real-time line-field optical coherence tomography (LF-OCT) system is demonstrated with image acquisition rates of up to 5000 B-frames or 2.5 million A-lines per second for 500 A-lines per B-frame. The system uses a high-speed low-cost camera to achieve continuous data transfer rates required for real-time imaging, allowing the evaluation of future applications in clinical or intraoperative environments. The light source is an 840 nm super-luminescent diode. Leveraging parallel computing with GPU and high speed CoaXPress data transfer interface, we were able to acquire, process, and display OCT data with low latency. The studied system uses anamorphic beam shaping in the detector arm, optimizing the field of view and sensitivity for imaging biological tissue at cellular resolution. The lateral and axial resolution measured in air were 1.7 µm and 6.3 µm, respectively. Experimental results demonstrate real-time inspection of the trabecular meshwork and Schlemm's canal on ex vivo corneoscleral wedges and real-time imaging of endothelial cells of human subjects in vivo.

3.
Curr Opin Ophthalmol ; 35(3): 252-259, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38205941

RESUMEN

PURPOSE OF REVIEW: In this review, we explore the investigational applications of optical coherence tomography (OCT) in retinopathy of prematurity (ROP), the insights they have delivered thus far, and key milestones for its integration into the standard of care. RECENT FINDINGS: While OCT has been widely integrated into clinical management of common retinal diseases, its use in pediatric contexts has been undermined by limitations in ergonomics, image acquisition time, and field of view. Recently, investigational handheld OCT devices have been reported with advancements including ultra-widefield view, noncontact use, and high-speed image capture permitting real-time en face visualization. These developments are compelling for OCT as a more objective alternative with reduced neonatal stress compared to indirect ophthalmoscopy and/or fundus photography as a means of classifying and monitoring ROP. SUMMARY: OCT may become a viable modality in management of ROP. Ongoing innovation surrounding handheld devices should aim to optimize patient comfort and image resolution in the retinal periphery. Future clinical investigations may seek to objectively characterize features of peripheral stage and explore novel biomarkers of disease activity.


Asunto(s)
Retinopatía de la Prematuridad , Recién Nacido , Humanos , Niño , Retinopatía de la Prematuridad/diagnóstico , Tomografía de Coherencia Óptica/métodos , Retina , Oftalmoscopía/métodos , Técnicas de Diagnóstico Oftalmológico
4.
Acta Biomater ; 173: 148-166, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37944773

RESUMEN

The conventional aqueous outflow pathway, encompassing the trabecular meshwork (TM), juxtacanalicular connective tissue (JCT), and inner wall endothelium of Schlemm's canal (SC), governs intraocular pressure (IOP) regulation. This study targets the biomechanics of low-flow (LF) and high-flow (HF) regions within the aqueous humor outflow pathway in normal and glaucomatous human donor eyes, using a combined experimental and computational approach. LF and HF TM/JCT/SC complex tissues from normal and glaucomatous eyes underwent uniaxial tensile testing. Dynamic motion of the TM/JCT/SC complex was recorded using customized green-light optical coherence tomography during SC pressurization in cannulated anterior segment wedges. A hyperviscoelastic model quantified TM/JCT/SC complex properties. A fluid-structure interaction model simulated tissue-aqueous humor interaction. FluoSpheres were introduced into the pathway via negative pressure in the SC, with their motion tracked using two-photon excitation microscopy. Tensile test results revealed that the elastic moduli of the LF and HF regions in glaucomatous eyes are 3.5- and 1.5-fold stiffer than the normal eyes, respectively. The FE results also showed significantly larger shear moduli in the TM, JCT, and SC of the glaucomatous eyes compared to the normal subjects. The LF regions in normal eyes demonstrated larger elastic moduli compared to the HF regions in glaucomatous eyes. The resultant strain in the outflow tissues and velocity of the aqueous humor in the FSI models were in good agreement with the digital volume correlation and 3D particle image velocimetry data, respectively. This study uncovers stiffer biomechanical responses in glaucomatous eyes, with LF regions stiffer than HF regions in both normal and glaucomatous eyes. STATEMENT OF SIGNIFICANCE: This study delves into the biomechanics of the conventional aqueous outflow pathway, a crucial regulator of intraocular pressure and ocular health. By analyzing mechanical differences in low-flow and high-flow regions of normal and glaucomatous eyes, this research unveils the stiffer response in glaucomatous eyes. The distinction between regions' properties offers insights into aqueous humor outflow regulation, while the integration of experimental and computational methods enhances credibility. These findings have potential implications for disease management and present a vital step toward innovative ophthalmic interventions. This study advances our understanding of glaucoma's biomechanical basis and its broader impact on ocular health.


Asunto(s)
Glaucoma , Malla Trabecular , Humanos , Fenómenos Biomecánicos , Malla Trabecular/metabolismo , Glaucoma/metabolismo , Humor Acuoso , Esclerótica/metabolismo , Presión Intraocular
5.
Invest Ophthalmol Vis Sci ; 64(14): 6, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37930688

RESUMEN

Purpose: The purpose of this study was to demonstrate the utility of polarization-diversity optical coherence tomography (PD-OCT), a noninvasive imaging technique with melanin-specific contrast, in the quantitative and qualitative assessment of choroidal nevi. Methods: Nevi were imaged with a custom-built 55-degree field-of-view (FOV) 400 kHz PD-OCT system. Imaging features on PD-OCT were compared to those on fundus photography, auto-fluorescence, ultrasound, and non-PD-OCT images. Lesions were manually segmented for size measurement and metrics for objective assessment of melanin distributions were calculated, including degree of polarization uniformity (DOPU), attenuation coefficient, and melanin occupancy rate (MOR). Results: We imaged 17 patients (mean age = 69.5 years, range = 37-90) with 11 pigmented, 3 non-pigmented, and 3 mixed pigmentation nevi. Nevi with full margin acquisition had an average longest basal diameter of 5.1 mm (range = 2.99-8.72 mm) and average height of 0.72 mm (range = 0.37 mm-2.09 mm). PD-OCT provided clear contrast of choroidal melanin content, distribution, and delineation of nevus margins for melanotic nevi. Pigmented nevi were found to have lower DOPU, higher attenuation coefficient, and higher MOR than non-pigmented lesions. Melanin content on PD-OCT was consistent with pigmentation on fundus in 15 of 17 nevi (88%). Conclusions: PD-OCT allows objective assessment of choroidal nevi melanin content and distribution. In addition, melanin-specific contrast by PD-OCT enables clear nevus margin delineation and may improve serial growth surveillance. Further investigation is needed to determine the clinical significance and prognostic value of melanin characterization by PD-OCT in the evaluation of choroidal nevi.


Asunto(s)
Neoplasias de la Coroides , Nevo Pigmentado , Nevo , Neoplasias Cutáneas , Humanos , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Tomografía de Coherencia Óptica , Melaninas , Nevo Pigmentado/diagnóstico por imagen , Nevo/diagnóstico por imagen , Neoplasias de la Coroides/diagnóstico por imagen
6.
Opt Lett ; 48(15): 3921-3924, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37527083

RESUMEN

This pilot study reports the development of optical coherence tomography (OCT) split-spectrum amplitude-decorrelation optoretinography (SSADOR) that measures spatially resolved photoreceptor response to light stimuli. Using spectrally multiplexed narrowband OCT, SSADOR improves sensitivity to microscopic changes without the need for cellular resolution or optical phase detection. Therefore, a large field of view (up to 3 × 1 mm2 demonstrated) using conventional OCT instrument design can be achieved, paving the way for clinical translation. SSADOR promises a fast, objective, and quantifiable functional biomarker for photoreceptor damage in the macula.


Asunto(s)
Tomografía de Coherencia Óptica , Tomografía de Coherencia Óptica/métodos , Proyectos Piloto
7.
IEEE Trans Med Imaging ; 42(11): 3219-3228, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37216244

RESUMEN

We introduce a new concept of panoramic retinal (panretinal) optical coherence tomography (OCT) imaging system with a 140° field of view (FOV). To achieve this unprecedented FOV, a contact imaging approach was used which enabled faster, more efficient, and quantitative retinal imaging with measurement of axial eye length. The utilization of the handheld panretinal OCT imaging system could allow earlier recognition of peripheral retinal disease and prevent permanent vision loss. In addition, adequate visualization of the peripheral retina has a great potential for better understanding disease mechanisms regarding the periphery. To the best of our knowledge, the panretinal OCT imaging system presented in this manuscript has the widest FOV among all the retina OCT imaging systems and offers significant values in both clinical ophthalmology and basic vision science.


Asunto(s)
Retina , Tomografía de Coherencia Óptica , Tomografía de Coherencia Óptica/métodos , Retina/diagnóstico por imagen
8.
Acta Biomater ; 164: 346-362, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37072067

RESUMEN

The aqueous humor actively interacts with the trabecular meshwork (TM), juxtacanalicular tissue (JCT), and Schlemm's canal (SC) through a dynamic fluid-structure interaction (FSI) coupling. Despite the fact that intraocular pressure (IOP) undergoes significant fluctuations, our understanding of the hyperviscoelastic biomechanical properties of the aqueous outflow tissues is limited. In this study, a quadrant of the anterior segment from a normal human donor eye was dynamically pressurized in the SC lumen, and imaged using a customized optical coherence tomography (OCT). The TM/JCT/SC complex finite element (FE) with embedded collagen fibrils was reconstructed based on the segmented boundary nodes in the OCT images. The hyperviscoelastic mechanical properties of the outflow tissues' extracellular matrix with embedded viscoelastic collagen fibrils were calculated using an inverse FE-optimization method. Thereafter, the 3D microstructural FE model of the TM, with adjacent JCT and SC inner wall, from the same donor eye was constructed using optical coherence microscopy and subjected to a flow load-boundary from the SC lumen. The resultant deformation/strain in the outflow tissues was calculated using the FSI method, and compared to the digital volume correlation (DVC) data. TM showed larger shear modulus (0.92 MPa) compared to the JCT (0.47 MPa) and SC inner wall (0.85 MPa). Shear modulus (viscoelastic) was larger in the SC inner wall (97.65 MPa) compared to the TM (84.38 MPa) and JCT (56.30 MPa). The conventional aqueous outflow pathway is subjected to a rate-dependent IOP load-boundary with large fluctuations. This necessitates addressing the biomechanics of the outflow tissues using hyperviscoelastic material-model. STATEMENT OF SIGNIFICANCE: While the human conventional aqueous outflow pathway is subjected to a large-deformation and time-dependent IOP load-boundary, we are not aware of any studies that have calculated the hyperviscoelastic mechanical properties of the outflow tissues with embedded viscoelastic collagen fibrils. A quadrant of the anterior segment of a normal humor donor eye was dynamically pressurized from the SC lumen with relatively large fluctuations. The TM/JCT/SC complex were OCT imaged and the mechanical properties of the tissues with embedded collagen fibrils were calculated using the inverse FE-optimization algorithm. The resultant displacement/strain in the FSI outflow model was validated versus the DVC data. The proposed experimental-computational workflow may significantly contribute to understanding of the effects of different drugs on the biomechanics of the conventional aqueous outflow pathway.


Asunto(s)
Humor Acuoso , Malla Trabecular , Humanos , Fenómenos Biomecánicos , Flujo de Trabajo , Malla Trabecular/metabolismo , Presión Intraocular , Colágeno/metabolismo
9.
JAMA Ophthalmol ; 2022 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-36227622

RESUMEN

Importance: Accurate diagnosis of retinopathy of prematurity (ROP) is essential to provide timely treatment and reduce the risk of blindness. However, the components of an ROP examination are subjective and qualitative. Objective: To evaluate whether optical coherence tomography (OCT)-derived retinal thickness measurements at the vascular-avascular junction are associated with clinical diagnosis of ROP stage. Design, Setting, and Participants: This cross-sectional longitudinal study compared OCT-based ridge thickness calculated from OCT B-scans by a masked examiner to the clinical diagnosis of 2 masked examiners using both traditional stage classifications and a more granular continuous scale at the neonatal intensive care unit (NICU) of Oregon Health & Science University (OHSU) Hospital. Infants who met ROP screening criteria in the OHSU NICU between June 2021 and April 2022 and had guardian consent were included. One OCT volume and en face image per patient per eye showing at least 1 to 2 clock hours of ridge were included in the final analysis. Main Outcomes and Measures: Comparison of OCT-derived ridge thickness to the clinical diagnosis of ROP stage using an ordinal and continuous scale. Repeatability was assessed using 20 repeated examinations from the same visit and compared using intraclass correlation coefficient (ICC) and coefficient of variation (CV). Comparison of ridge thickness with ordinal categories was performed using generalized estimating equations and with continuous stage using Spearman correlation. Results: A total of 128 separate OCT eye examinations from 50 eyes of 25 patients were analyzed. The ICC was 0.87 with a CV of 7.0%. Higher ordinal disease classification was associated with higher axial ridge thickness on OCT, with mean (SD) thickness measurements of 264.2 (11.2) µm (P < .001), 334.2 (11.4) µm (P < .001), and 495.0 (32.2) µm (P < .001) for stages 1, 2, and 3, respectively and with continuous stage labels (ρ = 0.739, P < .001). Conclusions and Relevance: These results suggest that OCT-based quantification of peripheral stage in ROP may be an objective and quantitative biomarker that may be useful for clinical diagnosis and longitudinal monitoring and may have implications for disease classification in the future.

10.
Biomed Opt Express ; 13(9): 5004-5014, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36187260

RESUMEN

Corneal imaging is important for the diagnostic and therapeutic evaluation of many eye diseases. Optical coherence tomography (OCT) is extensively used in ocular imaging due to its non-invasive and high-resolution volumetric imaging characteristics. Optical coherence microscopy (OCM) is a technical variation of OCT that can image the cornea with cellular resolution. Here, we demonstrate a blue-light OCM as a low-cost and easily reproducible system to visualize corneal cellular structures such as epithelial cells, endothelial cells, keratocytes, and collagen bundles within stromal lamellae. Our blue-light OCM system achieved an axial resolution of 12 µm in tissue over a 1.2 mm imaging depth, and a lateral resolution of 1.6 µm over a field of view of 750 µm × 750 µm.

11.
Transl Vis Sci Technol ; 11(8): 11, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35972433

RESUMEN

Purpose: To perform in vivo evaluation of the structural morphology and vascular plexuses of the neurosensory retina and choroid across vertebrate species using swept-source optical coherence tomography (SS-OCT) and SS-OCT angiography (SS-OCTA) imaging. Methods: A custom-built SS-OCT system with an incorporated flexible imaging arm was used to acquire the three-dimensional (3D) retinal OCT and vascular OCTA data of five different vertebrates: a mouse (C57BL/6J), a rat (Long Evans), a gray short-tailed opossum (Monodelphis domestica), a white sturgeon (Acipenser transmontanus), and a great horned owl (Bubo virginianus). Results: In vivo structural morphology of the retina and choroid, as well as en face OCTA images of retinal and choroidal vasculature of all species were generated. The retinal morphology and vascular plexuses were similar between rat and mouse, whereas distinct choroidal and paired superficial vessels were observed in the opossum retina. The retinal and vascular structure of the sturgeon, as well as the pecten oculi and overlying the avascular and choroidal vasculature in the owl retina are reported in vivo. Conclusions: A high-quality two-dimensional and 3D in vivo visualization of the retinal structures and en face visualization of the retina and choroidal vascular plexus of vertebrates was possible. Our studies affirm that SS-OCT and SS-OCTA are viable methods for evaluating the in vivo retinal and choroidal structure across terrestrial, aquatic, and aerial vertebrates. Translational Relevance: In vivo characterization of retinal morphology and vasculature plexus of multiple species using SS-OCT and SS-OCTA imaging can increase the pool of species available as models of human retinal diseases.


Asunto(s)
Coroides , Tomografía de Coherencia Óptica , Animales , Coroides/irrigación sanguínea , Coroides/diagnóstico por imagen , Angiografía con Fluoresceína/métodos , Humanos , Ratones , Ratones Endogámicos C57BL , Ratas , Ratas Long-Evans , Retina/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos
12.
Front Med (Lausanne) ; 9: 860371, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35860728

RESUMEN

Optical coherence tomography (OCT) has changed the standard of care for diagnosis and management of macular diseases in adults. Current commercially available OCT systems, including handheld OCT for pediatric use, have a relatively narrow field of view (FOV), which has limited the potential application of OCT to retinal diseases with primarily peripheral pathology, including many of the most common pediatric retinal conditions. More broadly, diagnosis of all types of retinal detachment (exudative, tractional, and rhegmatogenous) may be improved with OCT-based assessment of retinal breaks, identification of proliferative vitreoretinopathy (PVR) membranes, and the pattern of subretinal fluid. Intraocular tumors both benign and malignant often occur outside of the central macula and may be associated with exudation, subretinal and intraretinal fluid, and vitreoretinal traction. The development of wider field OCT systems thus has the potential to improve the diagnosis and management of myriad diseases in both adult and pediatric retina. In this paper, we present a case series of pediatric patients with complex vitreoretinal pathology undergoing examinations under anesthesia (EUA) using a portable widefield (WF) swept-source (SS)-OCT device.

14.
Biomed Opt Express ; 13(3): 1685-1701, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35414988

RESUMEN

The present paper introduces a numerical calibration method for the easy and practical implementation of multiple spectrometer-based spectral-domain optical coherence tomography (SD-OCT) systems. To address the limitations of the traditional hardware-based spectrometer alignment across more than one spectrometer, we applied a numerical spectral calibration algorithm where the pixels corresponding to the same wavelength in each unit are identified through spatial- and frequency-domain interferometric signatures of a mirror sample. The utility of dual spectrometer-based SD-OCT imaging is demonstrated through in vivo retinal imaging at two different operation modes with high-speed and dual balanced acquisitions, respectively, in which the spectral alignment is critical to achieve improved retinal image data without any artifacts caused by misalignment of the spectrometers.

15.
Biomed Opt Express ; 13(2): 950-961, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-35284155

RESUMEN

Photoreceptor loss and resultant thinning of the outer nuclear layer (ONL) is an important pathological feature of retinal degenerations and may serve as a useful imaging biomarker for age-related macular degeneration. However, the demarcation between the ONL and the adjacent Henle's fiber layer (HFL) is difficult to visualize with standard optical coherence tomography (OCT). A dedicated OCT system that can precisely control and continuously and synchronously update the imaging beam entry points during scanning has not been realized yet. In this paper, we introduce a novel imaging technology, Volumetric Directional OCT (VD-OCT), which can dynamically adjust the incident beam on the pupil without manual adjustment during a volumetric OCT scan. We also implement a customized spoke-circular scanning pattern to observe the appearance of HFL with sufficient optical contrast in continuous cross-sectional scans through the entire volume. The application of VD-OCT for retinal imaging to exploit directional reflectivity properties of tissue layers has the potential to allow for early identification of retinal diseases.

16.
Ophthalmol Sci ; 2(1)2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35128508

RESUMEN

OBJECTIVE: To determine whether handheld widefield optical coherence tomography (OCT) can be used to document retinopathy of prematurity (ROP) stage while using scleral depression to improve peripheral views. DESIGN: Prospective observational study. PARTICIPANTS: Consecutive neonates admitted to the neonatal intensive care unit (NICU) in a single academic medical center who also met criteria for ROP screening and consented for research imaging. METHODS: Scleral depression was combined with widefield OCT using an investigational 400-kHz, 55-degree field of view handheld OCT during routine ROP screening from October 28, 2020 to March 03, 2021. MAIN OUTCOME MEASURES: Acquisition of en face and B-scan imaging of the peripheral retina to objectively assess early vitreoretinal pathology, including the demarcation between vascularized and anterior avascular retina, the presence of early ridge formation, and small neovascular tufts. RESULTS: Various stages of ROP were detected using a rapid acquisition OCT system. In one neonate, serial OCT imaging over a five-week period demonstrated accumulation of neovascular tufts with progression to stage 3 ROP with extraretinal fibrovascular proliferation along the ridge. Videography of this technique is included in this report for instructional purposes. CONCLUSIONS: Serial examinations using widefield OCT and scleral depression is feasible and may improve detection and documentation of ROP disease progression. Earlier detection of ROP-related proliferation may prevent vitreoretinal traction, retinal detachment, and blindness.

17.
Opt Lett ; 46(23): 5878-5881, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34851913

RESUMEN

We demonstrate a handheld swept-source optical coherence tomography (OCT) system with a 400 kHz vertical-cavity surface-emitting laser (VCSEL) light source, a non-contact approach, and an unprecedented single shot 105° field of view (FOV). We also implemented a spiral scanning pattern allowing real-time visualization with improved scanning efficiency. To the best of our knowledge, this is the widest FOV achieved in a portable non-contact OCT retinal imaging system to date. Improvements to the FOV may aid the evaluation of retinal diseases such as retinopathy of prematurity, where important vitreoretinal changes often occur in the peripheral retina.


Asunto(s)
Enfermedades de la Retina , Tomografía de Coherencia Óptica , Humanos , Recién Nacido , Rayos Láser , Retina/diagnóstico por imagen
18.
Opt Lett ; 46(16): 3833-3836, 2021 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-34388753

RESUMEN

Megahertz-rate optical coherence tomography angiography (OCTA) is highly anticipated as an ultrafast imaging tool in clinical settings. However, shot-noise-limited sensitivity is inevitably reduced in high-speed imaging systems. In this Letter, we present a coherent buffer averaging technique for use with a Fourier-domain mode-locked (FDML) laser to improve OCTA contrast at 1060 nm MHz-rate retinal imaging. Full characterization of spectral variations among the FDML buffers and a numerical correction method are also presented, with the results demonstrating a 10-fold increase in the phase alignment among buffers. Coherent buffer averaging provided better OCTA contrast than the conventional multi-frame averaging approach with a faster acquisition time.


Asunto(s)
Rayos Láser , Tomografía de Coherencia Óptica , Angiografía , Retina
19.
Biomed Opt Express ; 12(6): 3553-3570, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-34221678

RESUMEN

Optical coherence tomography (OCT) and OCT angiography (OCTA) enable noninvasive structural and angiographic imaging of the eye. Portable handheld OCT/OCTA systems are required for imaging patients in the supine position. Examples include infants in the neonatal intensive care unit (NICU) and operating room (OR). The speed of image acquisition plays a pivotal role in acquiring high-quality OCT/OCTA images, particularly with the handheld system, since both the operator hand tremor and subject motion can cause significant motion artifacts. In addition, having a large field of view and the ability of real-time data visualization are critical elements in rapid disease screening, reducing imaging time, and detecting peripheral retinal pathologies. The arrangement of optical components is less flexible in the handheld system due to the limitation of size and weight. In this paper, we introduce a 400-kHz, 55-degree field of view handheld OCT/OCTA system that has overcome many technical challenges as a portable OCT system as well as a high-speed OCTA system. We demonstrate imaging premature infants with retinopathy of prematurity (ROP) in the NICU, a patient with incontinentia pigmenti (IP), and a patient with X-linked retinoschisis (XLRS) in the OR using our handheld OCT system. Our design may have the potential for improving the diagnosis of retinal diseases and help provide a practical guideline for designing a flexible and portable OCT system.

20.
Front Pediatr ; 9: 797684, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35118032

RESUMEN

Recent advances in portable optical coherence tomography (OCT) and OCT angiography (OCTA) have resulted in wider fields of view (FOV) and shorter capture times, further expanding the potential clinical role of OCT technology in the diagnosis and management of retinopathy of prematurity (ROP). Using a prototype, handheld OCT device, retinal imaging was obtained in non-sedated infants in the neonatal intensive care unit (NICU) as well as sedated infants in the operating room of Oregon Health & Science University (OHSU) Hospital. In this observational study, we provide an overview of potential advantages of OCT-based disease assessment in ROP. We observed that next-generation OCT imaging (a) may be sufficient for objective diagnosis and zone/stage/plus disease categorization, (b) allows for minimally-invasive longitudinal monitoring of disease progression and post-treatment course, (c) provides three-dimensional mapping of the vitreoretinal interface, and (d) with OCTA, enables dye-free visualization of normal and pathologic vascular development.