Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Lasers Med Sci ; 38(1): 234, 2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37831316

RESUMEN

In comparison to other commercially used lasers, the coagulation layer of the novel 450-nm laser is thinner, and this coagulation layer's thickness is a key factor influencing wound healing. In this study, we investigated whether the novel 200W 450-nm laser system (BR6800, Blueray Medical Ltd., Shaanxi, China) is superior to classic transurethral resection of the prostate (TURP) for wound healing in beagles. Twenty-two 6-to 8-year-old male beagles were treated with TURP or blue laser vaporization of the prostate (BLVP). Prostate wounds were observed via cystoscopy at 3 h and at 1, 2, 3, and 5 weeks post-operation (two beagles per group). Additionally, two elderly beagles without surgery served as normal controls. After cystoscopy examination, prostate samples were collected and fixed for hematoxylin and eosin (H&E) and immunofluorescence staining to observe wound healing progression under microscopy. The urethras of prostates under cystoscopy in BLVP groups were healed three weeks after surgery, while in the TURP group, they were healed five weeks after surgery. H&E staining confirmed that the coagulation necrosis layer in the TURP group was thicker than that in the BLVP group and it took longer to remove coagulation necrosis after surgery. Macrophage polarity transformation was also earlier in the BLVP group. The new 200W 450-nm laser was superior to TURP for wound healing. The thinner coagulation layer of the 450-nm laser was the primary reason for this process.


Asunto(s)
Terapia por Láser , Hiperplasia Prostática , Resección Transuretral de la Próstata , Masculino , Humanos , Animales , Perros , Anciano , Próstata/cirugía , Volatilización , Hiperplasia Prostática/cirugía , Rayos Láser , Cicatrización de Heridas , Necrosis/cirugía , Resultado del Tratamiento
2.
World J Urol ; 41(12): 3773-3779, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37833548

RESUMEN

OBJECTIVE: To explore the feasibility, safety and effectiveness of the 450-nm blue diode laser (BL), novel blue laser in the treatment of upper tract urothelial carcinomas (UTUCs) and other lesions in a porcine model. MATERIAL AND METHODS: For in vitro experiment, the ureter tissue was vaporised and coagulated with BL, green-light laser (GL) and Ho:YAG laser (Ho). The efficiency, width and depth of vaporisation, and depth of coagulation were recorded and compared. For in vivo experiments, four swines weighing 70 kg were used. In the acute group, different modes of operations were performed to evaluate the thermal damage, perforation and bleeding. In the chronic group, the overall appearance of the ureter and laser wound healing were observed by the naked eyes and H&E staining 3 weeks after surgery. RESULTS: In in vitro study, the BL showed a higher efficiency of tissue vaporisation and less tissue coagulation for fresh ureter compared to GL and Ho. In the in vivo study, the power of BL set at 7 W was better, and the thickness of thermal damage varied with different surgery types in the range of 74-306 µm. After 3 weeks, the wound healed well static in vaporisation (SV), moving vaporisation (MV) and H&E staining indicated mucosal healing rather than scar healing. CONCLUSION: 5-10W blue diode laser achieved a higher efficiency of tissue vaporisation and less tissue coagulation in a porcine model, indicating its potential application in the endoscopic surgery of UTUC as an optional device with high performance and safety.


Asunto(s)
Terapia por Láser , Láseres de Semiconductores , Porcinos , Animales , Láseres de Semiconductores/uso terapéutico , Sus scrofa , Cicatrización de Heridas , Cicatriz
3.
Phytomedicine ; 118: 154951, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37453193

RESUMEN

BACKGROUND: Hypertension has seriously affected a large part of the adult and elderly population. The complications caused by hypertension are important risk factors for cardiovascular disease accidents. Capsaicin, a pungent component of chili pepper has been revealed to improve hypertension. However, its potential mechanism in improving hypertension remains to be explored. PURPOSE: In the present study, we aimed to investigate whether capsaicin could attenuate the SIRT1/NF-κB/MAPKs pathway in the paraventricular nucleus of hypothalamus (PVN). METHODS: We used spontaneous hypertensive rats (SHRs) as animal model rats. Micro osmotic pump was used to give capsaicin through PVN for 28 days, starting from age12-week-old. RESULTS: The results showed that capsaicin significantly reduced blood pressure from the 16th day of infusion onward. At the end of the experimental period, we measured cardiac hypertrophy index and the heart rate (HR), and the results showed that the cardiac hypertrophy and heart rate of rats was significantly improved upon capsaicin chronic infusion. Norepinephrine (NE) and epinephrine (EPI) in plasma of SHRs treated with capsaicin were also decreased. Additionally, capsaicin increased the protein expression and number of positive cells of SIRT1 and the 67-kDa isoform of glutamate decarboxylase (GAD67), decreased the production of reactive oxygen species (ROS), number of positive cells of NOX2, those of Angiotensin Converting Enzyme (ACE) and p-IKKß, tyrosine hydroxylase (TH), the gene expression levels of NOX4 and pro-inflammatory cytokines. Capsaicin also decreased the relative protein expressions of protein in MAPKs pathway. CONCLUSION: Current data indicated that capsaicin within the PVN improves hypertension and cardiac hypertrophy via SIRT1/NF-κB/MAPKs pathway in the PVN of SHRs, supporting its potential as candidate drug for preventing and improving hypertension.


Asunto(s)
Hipertensión , FN-kappa B , Anciano , Humanos , Ratas , Animales , FN-kappa B/metabolismo , Núcleo Hipotalámico Paraventricular , Capsaicina/farmacología , Sirtuina 1/metabolismo , Hipertensión/tratamiento farmacológico , Hipertensión/metabolismo , Cardiomegalia/tratamiento farmacológico , Cardiomegalia/metabolismo , Ratas Endogámicas SHR
4.
Andrology ; 11(7): 1472-1483, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36869699

RESUMEN

BACKGROUND: Diabetes mellitus-induced erectile dysfunction is difficult to treat. The oxidative stress created by diabetes mellitus is a major cause of injuries to the corpus cavernosum, thereby resulting in erectile dysfunction. Near-infrared laser has already been shown to be effective in treating multiple brain disorders because of its antioxidative stress effect. OBJECTIVES: To investigate whether a near-infrared laser improves the erectile function of diabetes mellitus-induced erectile dysfunction rats through its antioxidative stress effect. MATERIALS AND METHODS: Knowing its advantage of reasonable deep tissue penetration and good photoactivation on mitochondria, a near-infrared laser with wavelength of 808 nm was used in the experiment. Since the internal and external corpus cavernosum were covered by different tissue layers, the laser penetration rates of the internal and external corpus cavernosum were measured separately. Different radiant exposure settings were applied: in the initial experiment, 40 male Sprague-Dawley rats were randomly assigned to five groups, normal controls, and streptozotocin-induced diabetes mellitus rats that 10 weeks later received various radiant exposures (J/cm2 ) from the near-infrared laser (DM0J(DM+NIR 0 J/cm2 ), DM1J, DM2J, and DM4J) in the subsequent 2 weeks. Erectile function was then assessed 1 week after near-infrared treatment. It was found that the initial radiant exposure setting was not optimal according to the Arndt-Schulz rule. We performed a second experiment using a different radiant exposure setting. Forty male rats were randomly divided into five groups (normal controls, DM0J, DM4J, DM8J, and DM16J), and the near-infrared laser was again applied according to the new setting, and erectile function was assessed as in the first experiment. Histologic, biochemical, and proteomic analyses were then conducted. RESULTS: Recovery of erectile function of varying degrees was observed in the near-infrared treatment groups, and radiant exposure of 4 J/cm2 achieved optimal results. The DM4J group showed improvement in mitochondrial function and morphology in diabetes mellitus rats, and it was found that oxidative stress levels were significantly reduced by near-infrared exposure. The tissue structure of the corpus cavernosum was also improved by near-infrared exposure. The proteomics analysis confirming multiple biologic processes were changed by diabetes mellitus and near-infrared. DISCUSSION AND CONCLUSION: Near-infrared laser activated mitochondria, improved oxidative stress, repaired the damage to penile corpus cavernosum tissue structures caused by diabetes mellitus, and improved erectile function in diabetes mellitus rats. These results thus raise the possibility that human patients with diabetes mellitus-induced erectile dysfunction may respond to near-infrared therapy in a manner that parallels the responses we observed in animal study.


Asunto(s)
Diabetes Mellitus Experimental , Disfunción Eréctil , Ratas , Masculino , Humanos , Animales , Disfunción Eréctil/etiología , Disfunción Eréctil/terapia , Ratas Sprague-Dawley , Proteómica , Erección Peniana , Pene/patología , Diabetes Mellitus Experimental/complicaciones , Diabetes Mellitus Experimental/patología
5.
Lasers Surg Med ; 54(7): 1002-1009, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35870192

RESUMEN

BACKGROUND: Due to the precise vaporization of the novel 450 nm blue diode laser in soft tissues (i.e., bladder and colon) in our previous studies, porcine stomach tissues were applied here to certify its efficacy in endoscopic mucosal resection (ESR)/endoscopic submucosal dissection (ESD) for hypothetical lesions ex vivo and in vivo. MATERIALS AND METHODS: In an ex vivo study of ESR, 20 pieces of tissues (8 cm × 6 cm) from 7 fresh stomachs after spraying saline were vaporized with a three-dimensional scanning system using the blue diode laser at a maximum of 30 W, a different treatment speed and working distance (WD). In ex vivo ESD, 18 pieces of tissues from 6 fresh stomachs were used and the same laser parameters were used to perform the procedure. The depth, width, and coagulation of the laser vaporization were measured. Furthermore, the large scales (2.0 cm × 1.5 cm) for 18 hypothetical lesions of the gastric mucosa and submucosa of the 6 fresh stomachs were also resected with a modified flexible endoscope. In vivo, six hypothetical lesions of six porcine were vaporized by the novel blue laser, and the resultant lesions at the acute and chronic stages were assessed by the naked eye and hematoxylin and eosin staining. RESULTS: In the contact mode, more tissue was vaporized, and the thickness of the coagulation was stable when the WD was 0-2 mm, whose value varied from 0.33 to 1.73 mm. In the gastroscopy model, the mean thickness of coagulation from the mucosa was 0.67 mm, and a significant carbonization zone was not observed. In vivo, the laser beam could accurately act on the hypothetical target. No bleeding and clear vision were present in the procedure. After 3 weeks, tissue healing was well recovered after laser coagulation, resection, and submucosal dissection. CONCLUSIONS: In the present study, the novel 450 nm blue diode laser exhibited ideal vaporization and thinner coagulation thickness in the porcine stomach, which indicated that it could be alternately used as a new device for stomach lesions.


Asunto(s)
Resección Endoscópica de la Mucosa , Animales , Endoscopios , Mucosa Gástrica , Láseres de Semiconductores , Estómago , Porcinos
6.
Lasers Med Sci ; 37(1): 555-561, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33770281

RESUMEN

A 450-nm blue laser may be suitable to treat benign prostate hyperplasia (BPH) due to its haemoglobin absorption characteristic. The present study compared a novel high-power 450-nm semiconductor blue laser with other lasers marketed for in vitro soft tissue ablation, to evaluate the safety and efficacy of the 450-nm laser in BPH surgery. With the in vitro tissues on an experimental platform in water, the vaporization efficiency and coagulation layer thickness of the novel 450-nm laser and commercially available 532-nm, 980-nm, and 1470-nm lasers were measured at the same power (120 W). The damage to the adjacent tissue and the working noise were also measured. The vaporization efficiency was proved to be 450-nm laser > 532-nm laser > 1470-nm laser > 980-nm laser. Comparison of coagulation layer thickness was as follow: 980-nm laser > 1470-nm laser > 532-nm laser > 450-nm laser. The degree of tissue damage caused by the 450-nm and 532-nm lasers increased with the decrease in distance and increase in time (these are safe when a sufficient distance and short irradiation time are maintained). The heating ability of 980-nm and 1470-nm lasers was much greater than that of 450-nm and 532-nm lasers. The working noise was lower in 450-nm and 1470-nm lasers. The novel 450-nm laser has the advantages of highly efficient tissue vaporization, creating a thin coagulation layer, and low working noise. These characteristics suggest that the novel 450-nm laser may be a promising choice for the surgical treatment of BPH.


Asunto(s)
Terapia por Láser , Hiperplasia Prostática , Humanos , Hiperplasia/patología , Láseres de Semiconductores/uso terapéutico , Masculino , Próstata/patología , Próstata/cirugía , Hiperplasia Prostática/patología , Hiperplasia Prostática/cirugía , Semiconductores , Resultado del Tratamiento
7.
Front Oncol ; 12: 1065735, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36733358

RESUMEN

Objectives: To be the first to apply a novel 450 nm blue diode laser in transurethral resection of bladder tumor (TURBt) to treat patients with non-muscle invasive bladder cancer (NMIBC) and evaluate its efficacy and safety during the preoperative period compared to the conventional plasmakinetic electrocautery. Materials and Methods: Randomized controlled trial (RCT) in five medical centers was designed as a non-inferiority study and conducted from October 2018 to December 2019. Patients with NMIBC were randomized to the blue laser or plasmakinetic electrocautery group for TURBt. As the first study to evaluate this novel blue laser device, the primary outcome was the effective resection rate of bladder tumors, including effective dissection and hemostasis. The secondary outcomes were the perioperative records, including surgical time, postoperative indwelling catheter time, hospital stay length, blood loss, reoperation rate, wound healing and adverse events. Results: A total of 174 patients were randomized to either the blue laser group (85 patients) or plasmakinetic electrocautery group (89 patients). There was no statistical significance in the clinical features of bladder tumors, including tumor site, number and maximum lesion size. Both the blue laser and plasmakinetic electrocautery could effectively dissect all visible bladder tumors. The surgical time for patients in the blue laser group was longer (p=0.001), but their blood loss was less than that of patients in the control group (p=0.003). There were no differences in the postoperative indwelling catheter time, hospital stay length, reoperation rate or other adverse events. However, the patients undergoing TURBt with the blue laser showed a faster wound healing at 3 months after operation. Conclusion: The novel blue laser could be effectively and safely used for TURBt in patients with NMIBC, and this method was not inferior to plasmakinetic electrocautery during the perioperative period. However, TURBt with the blue laser may provide the benefit to reduce preoperative blood loss and accelerate postoperative wound healing. Moreover, longer follow-up to confirm recurrence-free survival benefit was required.

8.
Cancer Sci ; 111(4): 1156-1164, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31967368

RESUMEN

p62 is associated with 2 major cellular defense mechanisms against metabolic and oxidative stress, autophagy and the Kelch-like ECH-associated protein 1 (KEAP1)-nuclear factor-E2-related factor 2 (NRF2) system. Recent studies indicate that the p62-KEAP1-NRF2 pathway promotes tumorigenesis and tumor growth mediated by NRF2-dependent antioxidative response. However, whether p62 is involved in bladder cancer (BCa) development remains unknown. Here, we found that p62 is overexpressed in BCa tissue and several BCa cell lines. The knockdown of p62 inhibits BCa cell growth both in vitro and in vivo, with increased intracellular reactive oxygen species level. Mechanically, p62 activates NRF2 signaling by sequestrating KEAP1, which leads to the upregulation of antioxidant genes (Gclc, Gstm5, and Gpx2), thus protecting BCa cells from oxidative stress. Our findings indicate that p62 might be involved in the development of BCa and serve as a potential therapeutic target.


Asunto(s)
Proteína 1 Asociada A ECH Tipo Kelch/genética , Factor 2 Relacionado con NF-E2/genética , Proteínas de Unión al ARN/genética , Neoplasias de la Vejiga Urinaria/genética , Animales , Antioxidantes/metabolismo , Autofagia/genética , Línea Celular Tumoral , Proliferación Celular/genética , Regulación Neoplásica de la Expresión Génica , Glutamato-Cisteína Ligasa/genética , Glutatión Peroxidasa/genética , Glutatión Transferasa/genética , Xenoinjertos , Humanos , Ratones , Estrés Oxidativo/genética , Especies Reactivas de Oxígeno/metabolismo , Transducción de Señal/genética , Activación Transcripcional/genética , Neoplasias de la Vejiga Urinaria/patología
9.
Photobiomodul Photomed Laser Surg ; 37(1): 25-30, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31050941

RESUMEN

Objective: Our study aimed to detect whether 450 nm blue laser can be applied effectively and safely in endosocopic submucosal dissection (ESD) system for surgery in colonic tissue. Background data: Semiconductor blue laser has been applied in surgery due to its excellent cutting property, however, whether blue laser can be applied in colonic surgery has not been reported. Materials and methods: Porcine colon tissues were vaporized by 450 nm blue semiconductor laser at 10-25 W and at working distances from 0.5 to 3 mm, with a three-dimensional scanning system. Moreover, we designed an ESD model and applied blue laser at 10 W on porcine colonic tissues with this system. Dimensions of the vaporized tissues and coagulation zones were assessed under microscopy. Results: Since the thickness of colonic wall is no more than 1 mm, first we determined the cutting property and safety of blue laser on porcine colon tissue and found that blue laser at 10 W made lesions shallower than 1 mm and the depth of vaporization can be controlled effectively within muscularis mucosa and submucosa. Moreover, a large scale of porcine colonic tissue was vaporized precisely by blue laser at power of 10 W with the ESD system ex vivo. Conclusions: Our results indicate that 450 nm blue laser at 10 W can be well controlled for laser-tissue interaction with excellent cutting efficiency and less thermal damage in adjacent tissues especially side of the submucosa. Therefore, 450 nm semiconductor blue laser could be a safe alternative approach for colonic surgery.


Asunto(s)
Colon/cirugía , Resección Endoscópica de la Mucosa/instrumentación , Láseres de Semiconductores/uso terapéutico , Animales , Diseño de Equipo , Técnicas In Vitro , Porcinos
10.
Lasers Med Sci ; 34(4): 807-813, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30406852

RESUMEN

Low-power blue laser allows clean cutting with little bleeding and no undesired coagulations in adjacent tissues; however, studies on high-power blue laser soft tissue ablation properties, including vaporization and coagulation, have not been reported yet. The purpose of this study is to evaluate and analyze the ablation efficacy and coagulation properties of bladder epithelium tissues with a 30-W 450-nm wavelength blue laser. Well-designed ex vivo experiments compared blue laser and 532-nm LBO green laser, both with laser power up to 30 W, for porcine bladder tissue vaporization and coagulation at different experimental parameter settings. At working distance of 1 mm and sweeping speed of 1.5 mm/s, the vaporization efficiency of blue laser and green laser was 5.14mm3/s and 1.20mm3/s, while the depth of coagulation layer was 460 ± 70 µm and 470 ± 80 µm, respectively. We found both blue laser and green laser have excellent efficacy of tissue vaporization and similar tissue coagulation properties. Moreover, in a set of in vivo experiments simulated laser transurethral resection (TUR) surgery on dogs, we found both blue laser and green laser exhibited similar and satisfactory vaporization and coagulation outcomes. Taken together, our results demonstrate that a 450-nm wavelength high-power diode blue laser, like 532-nm wavelength green laser, is capable to produce high efficient tissue vaporization, low-laser tissue penetration, good tissue coagulation, and has low thermal damage to adjacent tissues. Therefore, a 30-W blue diode laser could be a new and safe alternative for surgeries of superficial bladder diseases.


Asunto(s)
Terapia por Láser , Láseres de Semiconductores , Vejiga Urinaria/efectos de la radiación , Vejiga Urinaria/cirugía , Animales , Perros , Coagulación con Láser , Masculino , Porcinos
11.
Int J Oncol ; 53(1): 358-370, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29749439

RESUMEN

The present study aimed to examine the effects and mechanisms of exogenous C-X-C motif chemokine 5 (CXCL5) and lentiviral CXCL5 overexpression on the regulation of malignant behaviors of prostate cancer cells in vitro and in a nude mouse xenograft model. The expression levels of CXCL5 and a number of tumor-related genes were assessed by using semi-quantitative reverse transcription-polymerase chain reaction (RT-PCR), western blotting, ELISA, or immunohistochemistry in normal and cancerous prostate cells and tissues. Cell proliferation, colony formation, and Transwell assays were performed to determine the effects of exogenous, autocrine, and paracrine CXCL5 on prostate cancer cell proliferative and migratory capacity. The results indicated that CXCL5 expression was upregulated in PC­3 and DU145 prostate cancer cells, in WPMY­1 normal prostate stromal cells, and in RWPE­1 prostate epithelial cells, as well as in prostate cancer tissue specimens. Exogenous CXCL5 exposure resulted in increase in prostate cancer cell proliferation, colony formation, and migration. In cells transfected with a CXCL5 overexpression vector, in cells cultured in conditioned medium from CXCL5-overexpressing WPMY cells, and in cells co-cultured with CXCL5­OE WPMY cells prostate cancer cell malignant phenotypes were induced in an autocrine/paracrine fashion in vitro; similar results were observed in nude mouse xenografts. CXCL5 overexpression also regulated expression of tumor-related genes, including BAX, N-Myc downstream-regulated gene 3, extracellular signal-regulated kinase 1/2, C-X-C chemokine receptor type 2, interleukin 18, Bcl­2, and caspase­3. These data demonstrated that CXCL5 expression was upregulated in prostate cancer tissues and that exogenous CXCL5 protein exposure or CXCL5 overexpression promoted malignant phenotypes of prostate cancer cells in vitro and in vivo.


Asunto(s)
Proliferación Celular/genética , Quimiocina CXCL5/genética , Proteínas de Neoplasias/genética , Neoplasias de la Próstata/genética , Animales , Comunicación Autocrina/genética , Línea Celular Tumoral , Movimiento Celular/genética , Regulación Neoplásica de la Expresión Génica , Humanos , Lentivirus/genética , Masculino , Ratones , Comunicación Paracrina/genética , Neoplasias de la Próstata/patología , Transducción de Señal/genética , Células Madre , Ensayos Antitumor por Modelo de Xenoinjerto
12.
PLoS One ; 13(1): e0191180, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29370201

RESUMEN

Building evolution model of supply chain networks could be helpful to understand its development law. However, specific characteristics and attributes of real supply chains are often neglected in existing evolution models. This work proposes a new evolution model of supply chain with manufactures as the core, based on external market demand and internal competition-cooperation. The evolution model assumes the external market environment is relatively stable, considers several factors, including specific topology of supply chain, external market demand, ecological growth and flow conservation. The simulation results suggest that the networks evolved by our model have similar structures as real supply chains. Meanwhile, the influences of external market demand and internal competition-cooperation to network evolution are analyzed. Additionally, 38 benchmark data sets are applied to validate the rationality of our evolution model, in which, nine manufacturing supply chains match the features of the networks constructed by our model.


Asunto(s)
Equipos y Suministros , Industria Manufacturera , Comercio , Simulación por Computador , Mercadotecnía , Modelos Teóricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...