Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Appl Opt ; 61(36): 10727-10734, 2022 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-36606932

RESUMEN

This study proposes a refractive index (RI) sensor using a cascaded tapered thin-core microfiber (TTCMF) based on the Vernier effect. The thin-core fiber was made into a TTCMF by arc discharging and flame heating and then sandwiched between two single-mode fibers (SMFs). The two structures with the same SMF-TTCMF-SMF but slightly different free spectral ranges (FSRs) were cascaded to generate the Vernier effect. The FSR varied with the taper parameters of TTCMF. The RI sensitivities of a single TTCMF sensor, series SMF-TTCMF-SMF sensor, and parallel SMF-TTCMF-SMF sensor were compared and analyzed. Using the Vernier effect in the RI measurement range from 1.3313 to 1.3392, a very high RI sensitivity of -15,053.411n m/R I U was obtained using the series SMF-TTCMF-SMF structure, and -16,723.243n m/R I U using the parallel structure, which were basically consistent with the simulation results. Compared with the RI sensitivity of the single TTCMF sensor, the RI sensitivities of series and parallel sensors were increased by 4.65 times and 5.16 times, respectively. In addition, in the temperature range from 35°C to 65°C, temperature sensitivities of -0.196n m/ ∘ C and -0.0489n m/ ∘ C were obtained using series and parallel structures, respectively; the corresponding temperature cross errors were 1.302×10-5 R I U/ ∘ C and 2.92×10-6 R I U/ ∘ C, respectively. Based on the advantages of high RI sensitivity, simple structure, low-temperature cross sensitivity, and convenient fabrication, the proposed sensors have great potential in biosensing fields.

2.
Biomed Opt Express ; 10(10): 5136-5148, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31646036

RESUMEN

Programmed death ligand-1 (PD-L1) plays an important role in tumor evasion from the host immune system. The level of soluble PD-L1 (sPD-L1) in serum is closely related to tumor aggressiveness and outcomes. This study aimed to propose a localized surface Plasmon resonance (LSPR) biosensor based on excessively tilted fiber grating (ExTFG) coated with large-sized (∼160 nm) gold nanoshells for label-free and specific detection of sPD-L1. The experimental results showed that the limit of detection (LOD) of the immunosensor for sPD-L1 in buffer solutions was ∼1 pg/mL due to the enhanced LSPR effect resulting from the interaction between sPD-L1 molecules and anti-sPD-L1 monoclonal antibodies. The detection of sPD-L1 in complex serum media, such as fetal bovine serum, confirmed that the label-free immunosensor was extremely specific to sPD-L1 and could identify it at a concentration as low as 5 pg/mL. Therefore, it can be potentially applied in clinic for the fast and early diagnosis of cancer.

3.
Int J Biomed Imaging ; 2017: 7916260, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28567054

RESUMEN

X-ray fluorescence computed tomography (XFCT) based on sheet beam can save a huge amount of time to obtain a whole set of projections using synchrotron. However, it is clearly unpractical for most biomedical research laboratories. In this paper, polychromatic X-ray fluorescence computed tomography with sheet-beam geometry is tested by Monte Carlo simulation. First, two phantoms (A and B) filled with PMMA are used to simulate imaging process through GEANT 4. Phantom A contains several GNP-loaded regions with the same size (10 mm) in height and diameter but different Au weight concentration ranging from 0.3% to 1.8%. Phantom B contains twelve GNP-loaded regions with the same Au weight concentration (1.6%) but different diameter ranging from 1 mm to 9 mm. Second, discretized presentation of imaging model is established to reconstruct more accurate XFCT images. Third, XFCT images of phantoms A and B are reconstructed by filter back-projection (FBP) and maximum likelihood expectation maximization (MLEM) with and without correction, respectively. Contrast-to-noise ratio (CNR) is calculated to evaluate all the reconstructed images. Our results show that it is feasible for sheet-beam XFCT system based on polychromatic X-ray source and the discretized imaging model can be used to reconstruct more accurate images.

4.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(11): 3020-4, 2014 Nov.
Artículo en Chino | MEDLINE | ID: mdl-25752050

RESUMEN

Eliminating turbidity is a direct effect spectroscopy detection of COD key technical problems. This stems from the UV-visible spectroscopy detected key quality parameters depend on an accurate and effective analysis of water quality parameters analytical model, and turbidity is an important parameter that affects the modeling. In this paper, we selected formazine turbidity solution and standard solution of potassium hydrogen phthalate to study the turbidity affect of UV--visible absorption spectroscopy detection of COD, at the characteristics wavelength of 245, 300, 360 and 560 nm wavelength point several characteristics with the turbidity change in absorbance method of least squares curve fitting, thus analyzes the variation of absorbance with turbidity. The results show, In the ultraviolet range of 240 to 380 nm, as the turbidity caused by particle produces compounds to the organics, it is relatively complicated to test the turbidity affections on the water Ultraviolet spectra; in the visible region of 380 to 780 nm, the turbidity of the spectrum weakens with wavelength increases. Based on this, this paper we study the multiplicative scatter correction method affected by the turbidity of the water sample spectra calibration test, this method can correct water samples spectral affected by turbidity. After treatment, by comparing the spectra before, the results showed that the turbidity caused by wavelength baseline shift points have been effectively corrected, and features in the ultraviolet region has not diminished. Then we make multiplicative scatter correction for the three selected UV liquid-visible absorption spectroscopy, experimental results shows that on the premise of saving the characteristic of the Ultraviolet-Visible absorption spectrum of water samples, which not only improve the quality of COD spectroscopy detection SNR, but also for providing an efficient data conditioning regimen for establishing an accurate of the chemical measurement methods.

5.
Scanning ; 35(4): 277-82, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23168617

RESUMEN

Colorectal carcinoma (CRC) has high mortality and increased incidence rates. An early detection of CRC is very important. Multiphoton microscopy (MPM) with high resolution and high sensitivity is used to effectively distinguish the microstructure changes of normal and mucinous adenocarcinoma slices of ex vivo human colonic tissues. In mucinous adenocarcinoma mucosa, the glands are distorted and elongated, the gland cavity is indistinct, and the mesh collagen fibers are diminished. In the submucosa, the collagens are seriously disordered, elongated, pushed aside, and sparsely visible, the content of elastic fibers is also broken and almost disappearing. Many cancer cells, some in cavity-like shape full of mucus surrounded by some collagen fibers, occupied the submucosa, which are comparable to hematoxylin-eosin (HE) stained images. Second harmonic generation and two-photon excitation fluorescence (SHG/TPEF) intensity ratio can be used further to quantitatively evaluate normality and abnormality. The fast Fourier transform (FFT) images show that the normal collagen fibrils are dense and in random order, and the cancerous collagen is certainly organized. The exploratory results show that it has potential for the development of multiphoton mini-endoscopy in real-time early diagnosis of CRC.


Asunto(s)
Adenocarcinoma Mucinoso/patología , Neoplasias del Colon/patología , Mucosa Intestinal/patología , Microscopía de Fluorescencia por Excitación Multifotónica/métodos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen Óptica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA