Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Zhonghua Er Ke Za Zhi ; 61(2): 136-140, 2023 Feb 02.
Artículo en Chino | MEDLINE | ID: mdl-36720595

RESUMEN

Objective: To summarize the outcomes of different types of pulmonary atresia in neonates treated by ductus arteriosus stenting. Methods: This study was a retrospective cohort study. A total of 19 neonates who had pulmonary atresia treated by ductus arteriosus stenting in Xinhua Hospital, Shanghai Jiao Tong University School of Medicine from April 2014 to June 2021 were included. They were divided into the intact ventricular septum (PA-IVS) group and the ventricular septal defect (PA-VSD) group. Ductus arteriosus stents were implanted by different approaches. These children were followed up regularly at the 1, 3, 6, and 12 months after the surgery and annually since then to evaluate the outcome. Independent sample t-test was used for the statistical analysis. Results: There were 12 children in PA-IVS group and 7 in PA-VSD group. All of them were full term in fants. The gestational age of the PA-IVS group and the PA-VSD group was (38.8±1.1) and (37.7±1.8) weeks, the birth weights were (3.2±0.4) and (3.4±1.1) kg, and the age at operation was (10±9) and (12±7) days, respectively, without significant difference (all P>0.05). Among the 12 children with PA-IVS, 9 had stents successfully implanted through the femoral artery and 3 through the femoral vein. Of the 7 children with PA-VSD, 2 had the stents successfully implanted via the femoral artery and 2 failed, and the remaining 3 had stents successfully implanted via the left carotid artery. There was no postoperative thromboembolism, arteriovenous fistula, pseudoaneurysm or other vascular complications. Five children with PA-VSD who had successful operations were followed up at 6 months of age. They all had the operation for pulmonary atresia, repair of the ventricular septal defect, removal of arterial duct stents, and ligation of the arterial duct. All children survived without any stent displacement or stenosis and biventricular circulation was achieved during the follow-up. Conclusions: Ductus arteriosous stenting can be the first-stage treatment for children with PA-IVS and PA-VSD. In addition to the traditional femoral vein and femoral artery approach, the carotid artery can be used as a route for stent placement.


Asunto(s)
Conducto Arterioso Permeable , Conducto Arterial , Cardiopatías Congénitas , Defectos del Tabique Interventricular , Atresia Pulmonar , Niño , Recién Nacido , Humanos , Lactante , Atresia Pulmonar/cirugía , Estudios Retrospectivos , China , Conducto Arterioso Permeable/cirugía , Stents
2.
Zhonghua Er Ke Za Zhi ; 58(2): 96-100, 2020 Feb 02.
Artículo en Chino | MEDLINE | ID: mdl-32102144

RESUMEN

Objective: To investigate the safety and efficacy of transcatheter perforation of pulmonary valve by micro-guidewire and balloon dilation in the treatment of neonatal pulmonary atresia with intact ventricular septum (PA-IVS). Methods: The retrospective study included 21 neonates (14 males and 7 females) with PA-IVS who underwent transcatheter micro-guidewire pulmonary valve perforation and balloon dilation in Xinhua Hospital from January 2012 to December 2018. All patients underwent the pulmonary valve perforation by micro-guidewire through the Simmons catheter. During the follow-up period at 1, 3, 6, 12 months postoperatively and annually thereafter, the operative efficacy and the development of the right ventricle (RV) were evaluated by echocardiography. Statistical analyses were performed using t test. Results: A total of 21 neonates with PA-IVS were enrolled, and 13 cases were diagnosed prenatally. The median age of surgery was 6 days, the weight was (3.2±0.5) kg. The balloon/valve ratio was 1.19±0.12, and the RV pressure measured by catheter was (121±33) mmHg (1 mmHg=0.133 kPa) . The immediate postoperative RV pressure was (47±13) mmHg. The median follow-up time was 30 months. All the cases enrolled achieved biventricular circulation without death and serious complications. According to the last follow-up data including 16 cases who were followed up for 1 year or longer, the pulmonary artery transvalvular pressure was (29±15) mmHg. The postoperation ratio of right to left ventricular transverse diameter was significantly higher than that before operation (0.86+0.10 vs. 0.73+0.13, t=-2.96, P=0.006). Compared with preoperative data, the postoperation pulmonary valvular diameter Z-score was significantly higher (-1.41±0.89 vs. -2.83±1.06, t=-3.65, P=0.001) and the tricuspid valvular diameter Z-score was significantly higher (-0.52±0.29 vs. -1.34±0.81, t=-3.55, P=0.001). Conclusion: Transcatheter perforation of pulmonary valve by micro-guidewire and balloon dilation is a safe and effective initial therapy for neonatal PA-IVS.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Cateterismo/instrumentación , Cardiopatías Congénitas/cirugía , Tabiques Cardíacos/cirugía , Atresia Pulmonar/cirugía , Ablación por Catéter , Cateterismo/métodos , Dilatación , Femenino , Humanos , Recién Nacido , Masculino , Válvula Pulmonar/cirugía , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA