Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Huan Jing Ke Xue ; 41(3): 1393-1400, 2020 Mar 08.
Artículo en Chino | MEDLINE | ID: mdl-32608641

RESUMEN

Using a 150 L moving bed biofilm reactor (MBBR), with the temperature controlled at 28℃ and high NH4+-N concentration (average concentration 350 mg·L-1), inorganic wastewater was used as an influent to start the completely autotrophic nitrogen removal over nitrite (CANON) process. Meanwhile, the flocculent sludge was taken into a 5 L sequencing batch reactor, and the influent NH4+-N concentration was maintained at 90-200 mg·L-1 for the recovery of short-cut nitrification. The results showed that in the MBBR reactor, when the average hydraulic retention time (HRT) was 12 h, short-cut nitrification and total nitrogen (TN) removal rate were mutually constrained, the average TN removal rate was 38.2%, and the average δNO3--N/TN value was 0.274; when the HRT dropped to 6 h, the δNO3--N/TN value decreased from 0.347 to 0.146. The sequencing batch reactor (SBR) maintained aeration and anoxic time for 30 min and 20 min, respectively, by intermittent aeration, while the dissolved oxygen concentration during the aerobic process was 0.5 mg·L-1 to 0.6 mg·L-1, the free nitrous acid concentration was higher than 0.18 mg·L-1 at the end of each cycle, NAR increased from 0 to 99.2% after 12 days, NUR decreased to 0 from an initial 24.8 mg·(g·h)-1, and the TN removal rate decreased from 13% to 3%; the system successfully converted to short-range nitrification. High-throughput sequencing results showed that the abundance of Candidatus Kuenenia in the flocculent sludge and biofilm in the MBBR reactor were 7.91% and 17.38% respectively, Nitrosomonas accounted for 27.43% and 2.55%, respectively, while Nitrospira accounted for 0.30% and 0.28%, respectively. After the recovery of short-cut nitrification in the SBR, the abundance of ammonia-oxidizing bacteria and anaerobic ammonia oxidation decreased to 1.18% and 0.01%, respectively, and the abundance of Nitrospira increased to 1.39%.

2.
Zhongguo Zhong Yao Za Zhi ; 41(2): 250-256, 2016 Jan.
Artículo en Chino | MEDLINE | ID: mdl-28861970

RESUMEN

A quick HPLC-ESI-MS/MS method was established for simultaneous determination of four major diterpenoids in Rabdosia japonica var.glaucocalyx, including glaucocalyxin A, oridonin, hebeirubesensin and enmenol. Analysis was performed on an Agilent ZORBAX SB-C18(4.6 mm×250 mm, 5 µm ) column eluted in a gradient program with methanol and water. The flow rate was 0.8 mL•min⁻¹. Multiple reaction monitoring (MRM) scanning mode was performed in negative ion switching mode to apply for the quantitative determination. The calibration curves for the above four compounds were linear in corresponding injection amount. The average recoveries of the compounds ranged from 92.40% to 105.9%, with RSDs of 1.7%-6.5%. The method is simple, rapid, accurate with good repeatability, which can provide a reference for overcalling evaluation the quality of R. japonica var.glaucocalyx. The result of cluster analysis- showed that the quality of R. japonica glaucocalyx var. greatly varied between areas and parts.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Diterpenos/química , Medicamentos Herbarios Chinos/química , Isodon/química , Espectrometría de Masas en Tándem/métodos
3.
Zhongguo Zhong Yao Za Zhi ; 40(24): 4884-9, 2015 Dec.
Artículo en Chino | MEDLINE | ID: mdl-27245038

RESUMEN

A quick HPLC-ESI-MS/MS method was established for simultaneous determination of three chemical compositions in Usnea, including usnic acid, diffractaic acid, and ramalic acid. The separation was performed on a chromatographic column of Agilent ZORBAX SB-C, (4.6 mm x 250 mm, 5 µm), and the mobile phase was methanol (0.05% formic acid)-0.05% formic acid solution (4 mmol ammonium acetate), with an isocratic elution at a flow rate of 0.8 ml · min⁻¹. Multiple reaction monitoring scanning mode (MRM) was performed combined with the ion switching technology in positive and negative ion switching mode to apply for the quantitative determination. The calibration curves for the above three compounds were linear in corresponding injection amount. Their average recoveries were 95.0%-105.1%, with RSDs of 1.1%-5.2%. The method was simple, rapid, accurate with high repeatability, which could provide a reference for overcalling evaluation the quality of Usnea.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Hidroxibenzoatos/análisis , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masas en Tándem/métodos , Usnea/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...