Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Health Serv Res ; 22(1): 1406, 2022 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-36419040

RESUMEN

BACKGROUND: The management of medical device adverse event (MDAE) is one of the most important aspects of improving medical quality and safety management. Nonetheless, hospitals still lack standardized and unified initiatives to improve MDAE management. METHODS: This study, thus, established a MDAE monitoring system on May 1 in 2011 for suspected adverse events and designed a hospital-based dynamic warning system, aiming to standardize the process of MDAE handling and provide real-time monitoring for MDAEs in a hospital. This system was used in the First Affiliated Hospital of Zhejiang University School of Medicine. Numbers and the compound growth rate of MDAE reports from 2010 to 2020 were compared to test the effectiveness of the MDAE monitoring system. Numbers of MDAE reported to the National Adverse Event Monitoring System were also compared over 2013 to 2020, due to the loss of data before 2013 after shutdown of the old system. Efficacy and usability of the hospital-based dynamic warning system was then verified by analyzing risk and warning levels of MDAEs in 2020. Descriptive statistics was used for data analysis in this study. RESULTS: Results showed that the compound annual growth rates of MDAE reports and those submitted to the National Adverse Event Monitoring System from 2013 to 2020 were 35.0% and 31.5%, respectively. A standardized management of MDAE with full participant, timely response and effective feedback was formed in the hospital by establishment of the MDAE system. CONCLUSIONS: This system effectively improved the monitoring level of MDAEs, helping to improve early detection, early warning, and early intervention of risk of medical device. This study may provide suggestions for medical institutions to establish a MDAE monitoring system, and may promote development of medical quality and safety management for hospitals to some extent.


Asunto(s)
Hospitales , Medicina , Humanos , Administración de la Seguridad , Análisis de Datos , Intervención Educativa Precoz
2.
Front Psychol ; 13: 1070774, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36733883

RESUMEN

Background: Previous studies have emphasized the media as an essential channel for understanding information about depression. However, they have not divided groups according to the degree of media use to study their differences in depression. Therefore, this study aims to explore the influence of media use on depression and the influencing factors of depression in people with different media use degrees. Methods: Based on seven items related to media use, a total of 11, 031 respondents were categorized by the frequency of media use using latent profile analysis (LPA). Secondly, multiple linear regression analyzes were conducted to analyze the effects of depression in people with different degrees of media use. Finally, factors influencing depression among people with different degrees of media use were explored separately. Results: All respondents were classified into three groups: media use low-frequency (9.7%), media use general (67.1%), and media use high-frequency (23.2%). Compared with media use general group, media use low-frequency (ß = 0.019, p = 0.044) and media use high-frequency (ß = 0.238, p < 0.001) groups are significantly associated with depression. The factors influencing depression in the population differed between media use low-frequency, media use general, and media use high-frequency groups. Conclusion: The government and the appropriate departments should develop targeted strategies for improving the overall health status of people with different media use degrees.

3.
Neuropharmacology ; 178: 108250, 2020 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-32726599

RESUMEN

Volitional control is at the core of brain-machine interfaces (BMI) adaptation and neuroprosthetic-driven learning to restore motor function for disabled patients, but neuroplasticity changes and neuromodulation underlying volitional control of neuroprosthetic learning are largely unexplored. To better study volitional control at annotated neural population, we have developed an operant neuroprosthetic task with closed-loop feedback system by volitional conditioning of population calcium signal in the M1 cortex using fiber photometry recording. Importantly, volitional conditioning of the population calcium signal in M1 neurons did not improve within-session adaptation, but specifically enhanced across-session neuroprosthetic skill learning with reduced time-to-target and the time to complete 50 successful trials. With brain-behavior causality of the neuroprosthetic paradigm, we revealed that proficiency of neuroprosthetic learning by volitional conditioning of calcium signal was associated with the stable representational (plasticity) mapping in M1 neurons with the reduced calcium peak. Furthermore, pharmacological blockade of adenosine A2A receptors facilitated volitional conditioning of neuroprosthetic learning and converted an ineffective volitional conditioning protocol to be the effective for neuroprosthetic learning. These findings may help to harness neuroplasticity for better volitional control of neuroprosthetic training and suggest a novel pharmacological strategy to improve neuroprosthetic learning in BMI adaptation by targeting striatal A2A receptors.


Asunto(s)
Antagonistas del Receptor de Adenosina A2/farmacología , Señalización del Calcio/fisiología , Neuroestimuladores Implantables , Aprendizaje/fisiología , Corteza Motora/metabolismo , Receptor de Adenosina A2A/metabolismo , Volición/fisiología , Animales , Interfaces Cerebro-Computador , Señalización del Calcio/efectos de los fármacos , Aprendizaje/efectos de los fármacos , Ratones , Ratones Endogámicos C57BL , Corteza Motora/efectos de los fármacos , Neuronas/efectos de los fármacos , Neuronas/metabolismo , Fotometría/instrumentación , Fotometría/métodos , Purinas/farmacología , Volición/efectos de los fármacos
4.
Adv Exp Med Biol ; 1101: 67-89, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31729672

RESUMEN

Because of high spatial-temporal resolution of neural signals obtained by invasive recording, the invasive brain-machine interfaces (BMI) have achieved great progress in the past two decades. With success in animal research, BMI technology is transferring to clinical trials for helping paralyzed people to restore their lost motor functions. This chapter gives a brief review of BMI development from animal experiments to human clinical studies in the following aspects: (1) BMIs based on rodent animals; (2) BMI based on non-human primates; and (3) pilot BMIs studies in clinical trials. In the end, the chapter concludes with a summary of potential opportunities and future challenges in BMI technology.


Asunto(s)
Interfaces Cerebro-Computador , Animales , Interfaces Cerebro-Computador/normas , Interfaces Cerebro-Computador/tendencias , Ensayos Clínicos como Asunto , Humanos
5.
Behav Neurol ; 2017: 3435686, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29104374

RESUMEN

Electrocorticography (ECoG) has been demonstrated as a promising neural signal source for developing brain-machine interfaces (BMIs). However, many concerns about the disadvantages brought by large craniotomy for implanting the ECoG grid limit the clinical translation of ECoG-based BMIs. In this study, we collected clinical ECoG signals from the sensorimotor cortex of three epileptic participants when they performed hand gestures. The ECoG power spectrum in hybrid frequency bands was extracted to build a synchronous real-time BMI system. High decoding accuracy of the three gestures was achieved in both offline analysis (85.7%, 84.5%, and 69.7%) and online tests (80% and 82%, tested on two participants only). We found that the decoding performance was maintained even with a subset of channels selected by a greedy algorithm. More importantly, these selected channels were mostly distributed along the central sulcus and clustered in the area of 3 interelectrode squares. Our findings of the reduced and clustered distribution of ECoG channels further supported the feasibility of clinically implementing the ECoG-based BMI system for the control of hand gestures.


Asunto(s)
Mapeo Encefálico/métodos , Electrocorticografía/métodos , Movimiento/fisiología , Adulto , Algoritmos , Interfaces Cerebro-Computador , Epilepsia , Femenino , Gestos , Mano/fisiología , Humanos , Masculino , Corteza Motora/fisiología , Proyectos Piloto , Corteza Sensoriomotora/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...