Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 302
Filtrar
1.
Med Sci Sports Exerc ; 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38595212

RESUMEN

INTRODUCTION: Endurance exercise at altitude can increase cardiac output and pulmonary vascular pressure to levels that may exceed the stress-tolerability of the alveolar-capillary unit. This study examined the effect of ultra-marathon trail racing at different altitudes (ranging from <1000 m to between 1500 - 2700 m) on alveolar-capillary recruitment and lung diffusion. METHODS: Cardiac and lung function were examined before and after an ultra-marathon in 67 runners (age:41 ± 9y, BMI:23 ± 2 kg/m2, 10 females), and following 12-24 h of recovery in a subset (n = 27). Cardiac biomarkers (cTnI & BNP) were assessed from whole blood, while lung fluid accumulation (comet tails), stroke volume (SV) and cardiac output (Q) were quantified via echocardiography. Lung diffusing capacity for carbon monoxide (DLco) and its components, alveolar membrane conductance (Dm) and capillary blood volume (Vc), were determined via a single-breath method at rest and during three stages of submaximal semi-recumbent cycling (20, 30, & 40 W). RESULTS: Average race time was 25 ± 12 h. From pre- to post-race, there was an increase in cardiac biomarkers (cTnI: 0.04 ± .02 vs 0.13 ± .03 ng/ml; BNP: 20 ± 2 vs 112 ± 21 pg/ml, p < 0.01) and lung comet tails (2 ± 1 vs 7 ± 6, p < 0.01), a decrease in resting and exercise SV (76 ± 2 vs 69 ± 2 ml; 40 W: 93 ± 2 vs 88 ± 2 ml, p < 0.01), and an elevation in Q at rest (4.1 ± 0.1 vs 4.6 ± 0.2 l/min, p < 0.01; 40 W: 7.3 ± 0.2 vs 7.4 ± 0.3 l/min, p = 0.899). Resting DLco and Vc decreased after the race (p < 0.01), while Dm was unchanged (p = 0.465); however, during the three stages of exercise DLco, Vc and Dm were all reduced from pre- to post-race (40 W: 36.3 ± 0.9 vs 33.0 ± 0.8 mL/min/mmHg; 83 ± 3 vs 73 ± 2 mL; 186 ± 6 vs 170 ± 7 mL/min/mmHg, respectively, p < 0.01). When corrected for alveolar volume and Q, DLco decreased from pre- to post-race (p < 0.01), and changes in DLco were similar for all ultra-marathon events (p > 0.05). CONCLUSIONS: Competing in an ultra-marathon leads to a transient increase in cardiac injury biomarkers, mild lung-fluid accumulation, and impairments in lung diffusion. Reductions in DLco are predominantly caused by a reduced Vc and possible pulmonary capillary de-recruitment at rest. However, impairments in alveolar-capillary recruitment and Dm both contribute to a fall in exertional DLco following an ultra-marathon. Perturbations in lung diffusion were evident across a range of event distances and varying environmental exposures.

2.
ESC Heart Fail ; 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38637996

RESUMEN

This case study investigated the impact of SCS on alterations in blood pressure during constant-load exercise in a female patient with heart failure. Three different SCS frequencies [No SCS (~0 Hz), Low SCS (~100 Hz), and High SCS (~1000 Hz)] with and without ischaemic stimulation of the legs (cuffs) were randomly applied during constant-load exercise. To determine cardiovascular and ventilatory responses to exercise following SCS frequencies, BP, heart rate (HR), and respiratory gas exchange were measured. This experiment was duplicated in visit 1 and visit 2 with a random application of SCS frequency order and the data were averaged. There were no significant differences among three frequencies with no leg ischaemia. However, High SCS demonstrated lower BP, HR, and respiratory gas exchange relative to No SCS and Low SCS. SCS may be effective in improving cardiovascular and ventilatory responses in HF and high-frequency stimulation provides more clinical benefit; however, further studies are needed.

3.
Acute Crit Care ; 39(1): 162-168, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38476069

RESUMEN

BACKGROUND: Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. We investigated the relationship between changing common carotid artery Doppler measures and stroke volume (SV), hypothesizing that more consecutively-averaged cardiac cycles would improve SV-carotid Doppler correlation. METHODS: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. RESULTS: In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated-measures linear correlation [Rrm ]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively-averaged cardiac cycles. For ccFT, beyond four consecutively-averaged cardiac cycles the correlation coefficient remained strong (i.e., Rrm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, Rrm remained stable around 25 consecutively-averaged cardiac cycles. CONCLUSIONS: There was a strong linear correlation between changing SV and carotid Doppler measures during central blood volume loss. The strength of this relationship was dependent upon the number of consecutively-averaged cardiac cycles.

4.
J Breath Res ; 18(2)2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38290132

RESUMEN

Exhaustive exercise can induce unique physiological responses in the lungs and other parts of the human body. The volatile organic compounds (VOCs) in exhaled breath are ideal for studying the effects of exhaustive exercise on the lungs due to the proximity of the breath matrix to the respiratory tract. As breath VOCs can originate from the bloodstream, changes in abundance should also indicate broader physiological effects of exhaustive exercise on the body. Currently, there is limited published data on the effects of exhaustive exercise on breath VOCs. Breath has great potential for biomarker analysis as it can be collected non-invasively, and capture real-time metabolic changes to better understand the effects of exhaustive exercise. In this study, we collected breath samples from a small group of elite runners participating in the 2019 Ultra-Trail du Mont Blanc ultra-marathon. The final analysis included matched paired samples collected before and after the race from 24 subjects. All 48 samples were analyzed using the Breath Biopsy Platform with GC-Orbitrap™ via thermal desorption gas chromatography-mass spectrometry. The Wilcoxon signed-rank test was used to determine whether VOC abundances differed between pre- and post-race breath samples (adjustedP-value < .05). We identified a total of 793 VOCs in the breath samples of elite runners. Of these, 63 showed significant differences between pre- and post-race samples after correction for multiple testing (12 decreased, 51 increased). The specific VOCs identified suggest the involvement of fatty acid oxidation, inflammation, and possible altered gut microbiome activity in response to exhaustive exercise. This study demonstrates significant changes in VOC abundance resulting from exhaustive exercise. Further investigation of VOC changes along with other physiological measurements can help improve our understanding of the effect of exhaustive exercise on the body and subsequent differences in VOCs in exhaled breath.


Asunto(s)
Líquidos Corporales , Compuestos Orgánicos Volátiles , Humanos , Pruebas Respiratorias/métodos , Compuestos Orgánicos Volátiles/análisis , Espiración , Cromatografía de Gases y Espectrometría de Masas/métodos , Líquidos Corporales/química
5.
Cardiology ; 149(2): 183-188, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37827127

RESUMEN

BACKGROUND: Although assessment of cardiovascular hemodynamics during exercise can provide clinical insights, it is challenging to acquire it in clinical settings. OBJECTIVES: Accordingly, this preliminary study was to determine whether a novel elaboration on systolic time interval measures (eSTICO) method of quantifying cardiac output and stroke volume was comparable to those obtained using a validated soluble gas (open circuit CO measure [OpCircCO]) method or calculation based on oxygen consumption (oxygen consumption-based CO [VO2CO]) during exercise. METHODS: For the present study, 14 healthy subjects (male: n = 12, female: n = 2) performed incremental exercise on a recumbent cycle ergometer. At rest and during exercise, cardiac output (CO) was obtained via the eSTICO method, while the OpenCircCO and VO2CO measures were obtained at the last minute of each workload. RESULTS: At peak, there was no difference between eSTICO and OpCircCO (12.39 ± 3.06 vs. 13.96 ± 2.47 L/min, p > 0.05), while there was a slight difference between eSTICO and VO2CO (12.39 ± 3.06 vs. 14.28 ± 2.55 L/min, p < 0.05). When we performed correlation analysis with all subjects and all measures of CO at all WL, between eSTICO and OpenCircCO, there was a good relationship (r = 0.707, p < 0.001) with a Bland and Altman agreement analysis demonstrating a -1.6 difference (95% LoA: -6.3-3.5). Between eSTICO and VO2CO, we observed an r = 0.865 (p < 0.001) and a Bland and Altman agreement analysis with a -1.2 difference (95% LoA: -4.8-2.4). CONCLUSION: A novel exploitation of cardiac hemodynamics using systolic timing intervals may allow a relatively good assessment of CO during exercise in healthy adults.


Asunto(s)
Prueba de Esfuerzo , Adulto , Humanos , Masculino , Femenino , Sístole , Estudios de Factibilidad , Gasto Cardíaco , Volumen Sistólico
6.
Respir Physiol Neurobiol ; 320: 104200, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38036081

RESUMEN

BACKGROUND: The forced oscillation technique (FOT) enables non-invasive measurement of respiratory system impedance. Limited data exists on how changes in operating lung volume (OLV) impact FOT-derived measures of airway resistance (Rrs) and reactance (Xrs). OBJECTIVES: This study examined the reproducibility and responsiveness of FOT-derived measures of Rrs and Xrs during simulated changes in OLV. METHODS: Participants simulated breathing at six OLVs: total lung capacity (TLC), ∼50% of inspiratory reserve volume (IRV50), ∼two-times tidal volume (VT2), tidal volume (VT), ∼50% of expiratory reserve volume (ERV50), and residual volume (RV), on a commercially available FOT device. Each simulated OLV manuever was performed in triplicate and in random order. Total Rrs and Xrs were recorded at 5, 11, and 19 Hz. RESULTS: Twelve healthy participants (2 female) completed the study (weight: 76.5 ± 13.6 kg, height: 178.6 ± 9.7 cm, body mass index: 23.9 ± 3.1 kg/m2). Reproducibility of Rrs and Xrs at VT, VT2 and IRV50 was good to excellent (Range: ICC: 0.89-0.98, 95% confidence interval (CI): 0.70-0.98), while reproducibility at TLC, RV, and ERV50 was poor to excellent (Range: ICC: 0.60-0.98, 95% CI: 0.36-0.97). Rrs and Xrs were not different between VT and VT2 at any frequency (P > .05). With lung hyperinflation from VT to TLC, Rrs and Xrs decreased at all three frequencies (e.g., At 5 Hz Rrs: mean difference (MD): - 0.89, 95%CI: - 0.03 to - 1.75, P = .04; Xrs: MD: - 0.56, 95%CI: - 0.25 to - 0.86, P < .01). With lung hypoinflated from VT to RV, Rrs increased, and Xrs decreased for all frequencies (e.g., MD at 5 Hz, Rrs: MD: 2.31, 95%CI: 0.94-3.67, P < .01; Xrs: MD: -2.53, 95%CI: -4.02 to -1.04, P < .01). CONCLUSION: FOT-derived measures of airway Rrs and Xrs are reproducible across a range of OLV's, and are responsive to hyper- and hypo-inflation of the lung. To further understand the impact of lung hyper- and hypo-inflation on FOT-derived airway impedance additional study is required in individuals with pathological variations in operating lung volume.


Asunto(s)
Resistencia de las Vías Respiratorias , Pulmón , Humanos , Femenino , Reproducibilidad de los Resultados , Impedancia Eléctrica , Pruebas de Función Respiratoria/métodos , Mediciones del Volumen Pulmonar
8.
High Alt Med Biol ; 24(3): 230-233, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37722011

RESUMEN

Parks, Jordan K, Courtney M. Wheatley-Guy, Glenn M. Stewart, Caitlin C. Fermoyle, Bryan J. Taylor, Jesse Schwartz, Briana Ziegler, Kay Johnson, Alice Gavet, Loïc Chabridon, Paul Robach, and Bruce D. Johnson. Lung "Comet Tails" in healthy individuals: accumulation or clearance of extravascular lung water? High Alt Med Biol. 24:230-233, 2023-Ultrasound lung comet tails (or B-lines) tend to be limited in number (<5) or absent under ultrasound examination, and the appearance of diffuse B-lines with lung sliding has been suggested to identify pulmonary edema. Clinical evaluation of B-lines has been utilized as a bedside test to assess pulmonary congestion in patients with heart failure. Exposure to altitude or prolonged exercise can alter fluid regulation and can lead to pulmonary congestion or edema. As such, B-lines have been utilized in the field to monitor for pathological lung fluid accumulation. However, ultrasound lung comet lines might not be as reliable for identifying extravascular lung water (EVLW) as previously thought in healthy individuals exercising at altitude where an increase in the number of ultrasound lung comets would reflect fluid buildup in the interstitial space of the alveoli and pulmonary capillaries. This report will focus on reviewing the literature and our data from a group of ultraendurance runners that completed the Ultra Trail Mont Blanc race that demonstrates that lung comet tails may not always be evidence of pathological fluid accumulation in healthy individuals and as such should be used to assess EVLW in concert with other diagnostic testing.


Asunto(s)
Agua Pulmonar Extravascular , Edema Pulmonar , Masculino , Humanos , Agua Pulmonar Extravascular/diagnóstico por imagen , Edema Pulmonar/diagnóstico por imagen , Alveolos Pulmonares , Altitud , Ejercicio Físico
9.
Clin Auton Res ; 33(6): 659-672, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37598401

RESUMEN

PURPOSE: Exercise like any medication requires the correct dose; to be effective the appropriate frequency, duration, and intensity are necessary. This study aimed to assess if a semi-supervised exercise training (ET) program would be more effective at improving aerobic fitness (VO2PEAK), exercise tolerance, and symptoms in individuals with postural orthostatic tachycardia syndrome (POTS) compared to the standard of care (SOC). METHODS: Subjects were randomized to either the ET or SOC groups (n 26 vs. 23; age 33 ± 11 vs. 37 ± 10 years; VO2PEAK 66 ± 15 vs. 62 ± 15% predicted, ET vs. SOC respectively, p > 0.05). Composite Autonomic Symptom Score (COMPASS 31), 10 min stand test, and cardiopulmonary exercise test were performed at baseline and following 12 weeks. The ET group received an exercise consultation and eight semi-supervised in-person or virtual exercise sessions. RESULTS: The ET group demonstrated a greater improvement in VO2PEAK, higher or longer tolerance for baseline peak workload, and more often had a delayed symptom onset with exercise than the SOC group (ΔVO2PEAK 3.4 vs. - 0.2 mL/min/kg, p < 0.0001, ΔWorkload 19 ± 17 vs. 0 ± 10 W; Workload time 63 ± 29 vs. 22 ± 30 s; onset-delay 80% vs. 30%, p < 0.05). Individuals in the ET group reported a significant improvement in orthostatic intolerance domain score (p = 0.02), but there was not a significant difference in the improvement in total COMPASS score (- 11.38 vs. - 6.49, p = 0.09). CONCLUSION: Exercise training was more effective with greater improvements in aerobic fitness, orthostatic symptoms, and exercise tolerance for individuals with POTS when intensity and progression were personalized and delivered with minimal supervision compared to the SOC.


Asunto(s)
Intolerancia Ortostática , Síndrome de Taquicardia Postural Ortostática , Humanos , Adulto Joven , Adulto , Síndrome de Taquicardia Postural Ortostática/terapia , Síndrome de Taquicardia Postural Ortostática/diagnóstico , Ejercicio Físico , Intolerancia Ortostática/terapia , Intolerancia Ortostática/diagnóstico , Sistema Nervioso Autónomo , Prueba de Esfuerzo
10.
Respir Physiol Neurobiol ; 314: 104089, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37269888

RESUMEN

This study investigated the impact of exercise training on major pulmonary vasomotor mediators and receptors including endothelial nitric oxide synthase (eNOS) inducible NOS (iNOS), endothelin-1 (ET-1), ET-1 receptors A (ETA) and-B (ETB) in high-fat-high-carbohydrate (HFHC) induced non-alcoholic fatty liver disease (NAFLD). NAFLD increased iNOS, ET-1 and ETA (p < 0.05), but not ETB (p > 0.05). Exercise attenuated iNOS, ET-1 and ETA (p < 0.05)., but not ETB (p > 0.05) and eNOS (p > 0.05). Exercise training is beneficial for pulmonary vasculature in NAFLD.


Asunto(s)
Óxido Nítrico Sintasa , Enfermedad del Hígado Graso no Alcohólico , Humanos , Óxido Nítrico Sintasa/metabolismo , Enfermedad del Hígado Graso no Alcohólico/terapia , Óxido Nítrico Sintasa de Tipo II , ARN Mensajero , Óxido Nítrico Sintasa de Tipo III , Endotelina-1/metabolismo , Endotelina-1/farmacología , Receptor de Endotelina A , Ejercicio Físico
11.
Diagnostics (Basel) ; 13(9)2023 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-37174981

RESUMEN

A wireless, wearable Doppler ultrasound offers a new paradigm for linking physiology to resuscitation medicine. To this end, the image analysis of simultaneously-acquired venous and arterial Doppler spectrograms attained by wearable ultrasound represents a new source of hemodynamic data. Previous investigators have reported a direct relationship between the central venous pressure (CVP) and the ratio of the internal jugular-to-common carotid artery diameters. Because Doppler power is directly related to the number of red cell scatterers within a vessel, we hypothesized that (1) the ratio of internal jugular-to-carotid artery Doppler power (V/APOWER) would be a surrogate for the ratio of the vascular areas of these two vessels and (2) the V/APOWER would track the anticipated CVP change during simulated hemorrhage and resuscitation. To illustrate this proof-of-principle, we compared the change in V/APOWER obtained via a wireless, wearable Doppler ultrasound to B-mode ultrasound images during a head-down tilt. Additionally, we elucidated the change in the V/APOWER during simulated hemorrhage and transfusion via lower body negative pressure (LBNP) and release. With these Interesting Images, we show that the Doppler V/APOWER ratio qualitatively tracks anticipated changes in CVP (e.g., cardiac preload) which is promising for both diagnosis and management of hemodynamic unrest.

12.
Am J Cardiol ; 199: 44-49, 2023 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-37245249

RESUMEN

There is limited knowledge of pulmonary physiology and pulmonary function after continuous flow-left ventricular assist device (CF-LVAD) implantation. Therefore, this study investigated whether CF-LVAD influenced pulmonary circulation by assessing pulmonary capillary blood volume and alveolar-capillary conductance in addition to pulmonary function in patients with heart failure. Seventeen patients with severe heart failure who were scheduled for CF-LVAD implantation (HeartMate II, III, Abbott, Abbott Park, IL or Heart Ware, Medtronic, Minneapolis, MN) participated in the study. They underwent pulmonary function testing (measures of lung volumes and flow rates) and unique measures of pulmonary physiology using a rebreathe technique that quantified the diffusing capacity of the lungs for carbon monoxide (DLCO) and diffusing capacity of the lungs for nitric oxide before and 3 months after CF-LVAD implantation. After CF-LVAD, pulmonary function was not significantly changed (p >0.05). For lung diffusing capacity, alveolar volume (VA) was not changed (p = 0.47), but DLCO was significantly reduced (p = 0.04). After correcting for VA, DLCO/VA showed a trend toward reduction (p = 0.08). For the alveolar-capillary component, capillary blood volume (Vc) was significantly reduced (p = 0.04), and alveolar-capillary membrane conductance trended toward a reduction (p = 0.06). However, alveolar-capillary membrane conductance/Vc was not altered (p = 0.92). In conclusion, soon after CF-LVAD implantation, Vc is reduced likely because of pulmonary capillary derecruitment, which contributes to the decrease in lung diffusing capacity.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Pulmón , Insuficiencia Cardíaca/terapia , Circulación Pulmonar/fisiología , Capacidad de Difusión Pulmonar/fisiología
13.
JAMA ; 329(10): 801-809, 2023 03 14.
Artículo en Inglés | MEDLINE | ID: mdl-36871285

RESUMEN

Importance: Reduced heart rate during exercise is common and associated with impaired aerobic capacity in heart failure with preserved ejection fraction (HFpEF), but it remains unknown if restoring exertional heart rate through atrial pacing would be beneficial. Objective: To determine if implanting and programming a pacemaker for rate-adaptive atrial pacing would improve exercise performance in patients with HFpEF and chronotropic incompetence. Design, Setting, and Participants: Single-center, double-blind, randomized, crossover trial testing the effects of rate-adaptive atrial pacing in patients with symptomatic HFpEF and chronotropic incompetence at a tertiary referral center (Mayo Clinic) in Rochester, Minnesota. Patients were recruited between 2014 and 2022 with 16-week follow-up (last date of follow-up, May 9, 2022). Cardiac output during exercise was measured by the acetylene rebreathe technique. Interventions: A total of 32 patients were recruited; of these, 29 underwent pacemaker implantation and were randomized to atrial rate responsive pacing or no pacing first for 4 weeks, followed by a 4-week washout period and then crossover for an additional 4 weeks. Main Outcomes and Measures: The primary end point was oxygen consumption (V̇o2) at anaerobic threshold (V̇o2,AT); secondary end points were peak V̇o2, ventilatory efficiency (V̇e/V̇co2 slope), patient-reported health status by the Kansas City Cardiomyopathy Questionnaire Overall Summary Score (KCCQ-OSS), and N-terminal pro-brain natriuretic peptide (NT-proBNP) levels. Results: Of the 29 patients randomized, the mean age was 66 years (SD, 9.7) and 13 (45%) were women. In the absence of pacing, peak V̇o2 and V̇o2 at anaerobic threshold (V̇o2,AT) were both correlated with peak exercise heart rate (r = 0.46-0.51, P < .02 for both). Pacing increased heart rate during low-level and peak exercise (16/min [95% CI, 10 to 23], P < .001; 14/min [95% CI, 7 to 21], P < .001), but there was no significant change in V̇o2,AT (pacing off, 10.4 [SD, 2.9] mL/kg/min; pacing on, 10.7 [SD, 2.6] mL/kg/min; absolute difference, 0.3 [95% CI, -0.5 to 1.0] mL/kg/min; P = .46), peak V̇o2, minute ventilation (V̇e)/carbon dioxide production (V̇co2) slope, KCCQ-OSS, or NT-proBNP level. Despite the increase in heart rate, atrial pacing had no significant effect on cardiac output with exercise, owing to a decrease in stroke volume (-24 mL [95% CI, -43 to -5 mL]; P = .02). Adverse events judged to be related to the pacemaker device were observed in 6 of 29 participants (21%). Conclusions and Relevance: In patients with HFpEF and chronotropic incompetence, implantation of a pacemaker to enhance exercise heart rate did not result in an improvement in exercise capacity and was associated with increased adverse events. Trial Registration: ClinicalTrials.gov Identifier: NCT02145351.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Femenino , Anciano , Masculino , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Volumen Sistólico , Método Doble Ciego , Prueba de Esfuerzo
14.
High Alt Med Biol ; 24(2): 144-148, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-29172727

RESUMEN

Anderson, Paul J., Christina M. Wood-Wentz, Kent R. Bailey, and Bruce D. Johnson. Objective versus self-reported sleep quality at high altitude. High Alt Med Biol. 24:144-148, 2023. Background: Previous studies have found little relationship between polysomnography and a diagnosis of acute mountain sickness (AMS) using the Lake Louise Symptom Questionnaire (LLSQ). The correlation between sleep question responses on the LLSQ and polysomnography results has not been explored. We compared LLSQ sleep responses and polysomnography data from our previous study of workers rapidly transported to the South Pole. Methods: Sixty-three subjects completed a 3-hour flight from sea level to the South Pole (3200 m, 9800 ft). Participants completed limited overnight polysomnography on their first night and completed LLSQ upon awakening. We compared polysomnography results at the South Pole with sleep question responses on the LLSQ to assess their degree of correspondence. Results: Twenty-two (30%) individuals reported no sleep problems whereas 20 (32%) reported some problems and 20 (33%) individuals reported poor sleep and 1 reported no sleep (n = 1). Median sleep efficiency was (94%) among response groups and mean overnight oxygen saturation was 81%. Median apnea hypopnea index (AHI; events/hour) was 10.2 in those who reported no problems sleeping, 5.1 in those reporting some problems sleeping, and 13.7 in those who reported poor sleep. These differences were not statistically significant. Conclusion: Self-reported sleep quality varied but there were no associated significant differences in sleep efficiency, overnight oxygen saturation, nor AHI. Studies that explore the role of objective sleep quality in the development of AMS should remove the sleep question on the LLSQ from AMS scoring algorithms.


Asunto(s)
Mal de Altura , Altitud , Humanos , Calidad del Sueño , Autoinforme , Mal de Altura/diagnóstico , Sueño/fisiología , Enfermedad Aguda
15.
J Med Ultrasound ; 31(4): 309-313, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38264586

RESUMEN

Background: Doppler ultrasound of the common carotid artery is used to infer central hemodynamics. For example, change in the common carotid artery corrected flow time (ccFT) and velocity time integral (VTI) are proposed surrogates of changing stroke volume. However, conflicting data exist which may be due to inadequate beat sample size and measurement variability - both intrinsic to handheld systems. In this brief communication, we determined the correlation between changing ccFT and carotid VTI during progressively severe central blood volume loss and resuscitation. Methods: Measurements were obtained through a novel, wireless, wearable Doppler ultrasound system. Sixteen participants (ages of 18-40 years with no previous medical history) were studied across 25 lower body-negative pressure protocols. Relationships were assessed using repeated-measures correlation regression models. Results: In total, 33,110 cardiac cycles comprise this analysis; repeated-measures correlation showed a strong, linear relationship between ccFT and VTI. The strength of the ccFT-VTI relationship was dependent on the number of consecutively averaged cardiac cycles (R1 cycle = 0.70, R2 cycles = 0.74, and R10 cycles = 0.81). Conclusions: These results positively support future clinical investigations employing common carotid artery Doppler as a surrogate for central hemodynamics.

16.
Front Physiol ; 13: 1018057, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36569769

RESUMEN

Introduction: Aircrew may experience rapidly oscillating inspired O2/N2 ratios owing to fluctuations in the on-board oxygen delivery systems (OBOG). Recent investigations suggest these oscillations may contribute to the constellation of physiologic events in aircrew of high-performance aircraft. Therefore, the purpose of this study was to determine whether these "operationally-relevant" environmental challenges may cause decrements in measures of pulmonary vascular physiology. Methods: Thirty healthy participants (Age: 29 ± 5 years) were recruited and assigned to one of the three exposures. Participants were instrumented for physiologic monitoring and underwent baseline cardiopulmonary physiology testing (ground level) consisting of a rebreathe method for quantifying pulmonary blood flow (Qc), pulmonary capillary blood volume (Vc) and alveolar-capillary conductance (Dm). Ultrasound was used to quantify "comet tails" (measure of lung fluid balance). After baseline testing, the participants had two 45 min exposures to an altitude of 8,000 ft where they breathed from gas mixtures alternating between 80/20 and 30/70 O2/N2 ratios at the required frequency (30 s, 60 s, or 120 s), separated by repeat baseline measure. Immediately and 45 min after the second exposure, baseline measures were repeated. Results: We observed no changes in Qc, Dm or Vc during the 60 s exposures. In response to the 30 s oscillation exposure, there was a significantly reduced Qc and Vc at the post-testing period (p = 0.03). Additionally, exposure to the 120 s oscillations resulted in a significant decrease in Vc at the recovery testing period and an increase in the Dm/Vc ratio at both the post and recovery period (p < 0.01). Additionally, we observed no changes in the number of comet tails. Conclusion: These data suggest "operationally-relevant" changes in inspired gas concentrations may cause an acute, albeit mild pulmonary vascular derecruitment, reduced distention and/or mild pulmonary-capillary vasoconstriction, without significant changes in lung fluid balance or respiratory gas exchange. The operational relevance remains less clear, particularly in the setting of additional environmental stressors common during flight (e.g., g forces).

17.
Artículo en Inglés | MEDLINE | ID: mdl-36554807

RESUMEN

Adults with cardiovascular disease and heart failure are at higher risk of cognitive decline. Cerebral hypoperfusion appears to be a significant contributor, which can result from vascular dysfunction and impairment of cerebral blood flow regulation. In contrast, higher cardiorespiratory fitness shows protection against brain atrophy, reductions in cerebral blood flow, and cognitive decline. Given that high intensity interval training (HIIT) has been shown to be a potent stimulus for improving cardiorespiratory fitness and peripheral vascular function, its utility for improving cognitive aging is an important area of research. This article will review the physiology related to cerebral blood flow regulation and cognitive decline in adults with cardiovascular disease and heart failure, and how HIIT may provide a more optimal stimulus for improving cognitive aging in this population.


Asunto(s)
Capacidad Cardiovascular , Enfermedades Cardiovasculares , Envejecimiento Cognitivo , Cardiopatías , Insuficiencia Cardíaca , Entrenamiento de Intervalos de Alta Intensidad , Adulto , Humanos
18.
BMC Med ; 20(1): 429, 2022 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-36348343

RESUMEN

BACKGROUND: Non-alcoholic fatty liver disease (NAFLD) can lead to pulmonary dysfunction that is associated with pulmonary inflammation. Moreover, little is known regarding the therapeutic role of exercise training on pulmonary pathophysiology in NAFLD. The present study aimed to investigate the effect of exercise training on high-fat high-carbohydrate (HFHC)-induced pulmonary dysfunction in C57BL/6 mice. METHODS: Male C57BL/6 mice (N = 40) were fed a standard Chow (n = 20) or an HFHC (n = 20) diet for 15 weeks. After 8 weeks of dietary treatment, they were further assigned to 4 subgroups for the remaining 7 weeks: Chow (n = 10), Chow plus exercise (Chow+EX, n = 10), HFHC (n = 10), or HFHC plus exercise (HFHC+EX, n = 10). Both Chow+EX and HFHC+EX mice were subjected to treadmill running. RESULTS: Chronic exposure to the HFHC diet resulted in obesity with hepatic steatosis, impaired glucose tolerance, and elevated liver enzymes. The HFHC significantly increased fibrotic area (p < 0.001), increased the mRNA expression of TNF-α (4.1-fold, p < 0.001), IL-1ß (5.0-fold, p < 0.001), col1a1 (8.1-fold, p < 0.001), and Timp1 (6.0-fold, p < 0.001) in the lung tissue. In addition, the HFHC significantly altered mitochondrial function (p < 0.05) along with decreased Mfn1 protein levels (1.8-fold, p < 0.01) and increased Fis1 protein levels (1.9-fold, p < 0.001). However, aerobic exercise training significantly attenuated these pathophysiologies in the lungs in terms of ameliorating inflammatory and fibrogenic effects by enhancing mitochondrial function in lung tissue (p < 0.001). CONCLUSIONS: The current findings suggest that exercise training has a beneficial effect against pulmonary abnormalities in HFHC-induced NAFLD through improved mitochondrial function.


Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Neumonía , Ratones , Masculino , Animales , Enfermedad del Hígado Graso no Alcohólico/terapia , Enfermedad del Hígado Graso no Alcohólico/metabolismo , Ratones Endogámicos C57BL , Hígado/metabolismo , Modelos Animales de Enfermedad , Carbohidratos/farmacología , Mitocondrias/metabolismo
19.
Sensors (Basel) ; 22(19)2022 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-36236381

RESUMEN

Czech physiologist Penaz tried to overcome limitations of invasive pulse-contour methods (PCM) in clinical applications by a non-invasive method (finger mounted BP cuff) for continuous arterial waveform detection and beat-to-beat analysis. This discovery resulted in significant interest in human physiology and non-invasive examination of hemodynamic parameters, however has limitations because of the distal BP recording using a volume-clamp method. Thus, we propose a validation of beat-to-beat signal analysis acquired by novel a brachial occlusion-cuff (suprasystolic) principle and signal obtained from Finapres during a forced expiratory effort against an obstructed airway (Valsalva maneuver). Twelve healthy adult subjects [2 females, age = (27.2 ± 5.1) years] were in the upright siting position, breathe through the mouthpiece (simultaneously acquisition by brachial blood pressure monitor and Finapres) and at a defined time were asked to generate positive mouth pressure for 20 s (Valsalva). For the purpose of signal analysis, we proposed parameter a "Occlusion Cuff Index" (OCCI). The assumption about similarities between measured signals (suprasystolic brachial pulse waves amplitudes and Finapres's MAP) were proved by averaged Pearson's correlation coefficient (r- = 0.60, p < 0.001). The averaged Pearson's correlation coefficient for the comparative analysis of OCCI between methods was r- = 0.88, p < 0.001. The average percent change of OCCI during maneuver: 8% increase, 19% decrease and percent change of max/min ratio is 35%. The investigation of brachial pulse waves measured by novel brachial blood pressure monitor shows positive correlation with Finapres and the parameter OCCI shows promise as an index, which could describe changes during beat-to-beat cardiac cycles.


Asunto(s)
Arteria Braquial , Análisis de la Onda del Pulso , Adulto , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Arteria Braquial/fisiología , Estudios de Factibilidad , Femenino , Dedos , Frecuencia Cardíaca , Humanos , Adulto Joven
20.
Front Psychol ; 13: 959515, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36186373

RESUMEN

Rationale: There are growing concerns over the occurrence of adverse physiologic events (PEs) occurring in pilots during operation of United States Air Force and Navy high-performance aircraft. We hypothesize that a heightened inspiratory work of breathing experienced by jet pilots by virtue of the on-board life support system may constitute a "distraction stimulus" consequent to an increased sensation of respiratory muscle effort. As such, the purpose of this study was to determine whether increasing inspiratory muscle effort adversely impacts on attentional performance. Methods: Twelve, healthy participants (age: 29 ± 6 years) were recruited for this study. Participants completed six repetitions of a modified Masked Conjunctive Continuous Performance Task (MCCPT) protocol while breathing against four different inspiratory threshold loads to assess median reaction times (RTs). A computer-controlled threshold loading device was used to set the inspiratory threshold loads. Repeated measures analysis of variances (ANOVAs) were performed to examine: (i) the efficacy of the threshold loading device to impose significantly higher loading at each loading condition; (ii) the effects of loading condition on respiratory muscle effort sensation; and (iii) the influence of hypercapnia on MCCPT scores during inspiratory threshold loading. Generalized additive mixed effects models (GAMMs) were used to examine the potential non-linear effects of respiratory muscular effort sensation, device loading, and hypercapnia, on MCCPT scores during inspiratory threshold loading. Results: Inspiratory threshold loading significantly augmented (P < 0.05) inspiratory effort sensation and the inspiratory pressure-time product (PTP). Our analyses also revealed that median hit RT was positively associated with inspiratory effort sensation during inspiratory loading trials. Conclusion: The findings of this work suggest that it was not increasing inspiratory muscle effort (i.e., PTP) per se, but rather participant's subjective perception of inspiratory "load" that impacts negatively on attentional performance; i.e., as the degree of inspiratory effort sensation increased, sotoo did median hit RT. As such, it is reasonable to suggest that minimizing inspiratory effort sensation (independent of the mechanical output of the inspiratory muscles) during high-performance flight operations may prove useful in reducing pilot RTs during complex behavioral tasks.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...