Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 762
Filtrar
1.
Ocul Oncol Pathol ; 10(1): 43-52, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38751499

RESUMEN

Purpose: Ocular dirofilariasis is an uncommon zoonotic infection that is usually associated with a carnivore host. In this case series and literature review, we investigate the clinical presentation, management, and histopathology of ocular dirofilariasis. Methods: The database at the Florida Lions Ocular Pathology Laboratory was searched for surgical specimens at the Bascom Palmer Eye Institute under approval of the Institutional Review Board. Patients with a histopathologic diagnosis of dirofilariasis between the years 1962 and 2022 from the Florida Lions Ocular Pathology Laboratory database were included (n = 3). A systematic PubMed search was conducted by two independent authors to identify published cases of ophthalmic dirofilariasis worldwide. Keywords were used to identify articles, and exclusion criteria were applied. Results: Three patients, two males and one female, were identified from the Florida Lions Ocular Pathology Laboratory database with a diagnosis of ocular dirofilariasis. The mean age was 46.7 years (with a range 33-57 years). There were two eyelid lesions (Cases 1 and 3) and one involving the subconjunctival space (Case 2). All three organisms were excised and presumptively identified as Dirofilaria tenuis. All 3 patients were managed with curative surgical removal and recovered completely. Our review of the literature identified 540 published reports and 142 published reports with 186 cases that met the exclusion criteria. Conclusion: We present a case series and literature review of ocular dirofilariasis. Knowledge of the incidence, risk factors, prevention, and diagnosis of this unique parasitic infection will help in proper management and prevent further ocular complications.

2.
JACC Cardiovasc Interv ; 17(9): 1106-1115, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38749590

RESUMEN

BACKGROUND: Unintended deformation of implanted coronary stents can lead to loss of coronary access, stent thrombosis and coronary events during follow-up. The incidence, mechanisms and clinical outcomes of unintended stent deformations (USD) during complex bifurcation stenting are not well characterized. OBJECTIVES: In a prespecified analysis of the OCTOBER (European Trial on Optical Coherence Tomography Optimized Bifurcation Event Reduction) trial, we aimed to: 1) determine the incidence and characterize mechanisms of USD identified by optical coherence tomography (OCT); and 2) evaluate physician's detection and correction of accidental abluminal rewiring and USD. METHODS: OCT scans were analyzed for accidental abluminal rewiring and USD. When USD was identified, the plausible mechanism was determined by analysis of all procedural OCT scans and the corresponding angiograms. RESULTS: USD was identified by the core lab in 9.3% (55/589) of OCT-guided cases. Accidental abluminal rewiring was the cause in 44% (24/55), and guide catheter collision was the cause in 40% (22/55) of cases. USD was found in 18.5% of all cases with left main bifurcation percutaneous coronary intervention. The total incidence of abluminal rewiring was 33 in 32 OCT-guided cases (5.4%) and was corrected by physicians in 18 of 33 appearances (54.5%). The 2-year major adverse cardiac event rate for patients with untreated USD (n = 30) was 23.3%, whereas patients with confirmed or possibly corrected USD (n = 25) had no events during follow-up. CONCLUSIONS: USD was associated with adverse procedural complications and cardiac events during follow-up when not identified and corrected. The predominant mechanisms were undetected abluminal rewiring and guide catheter collision. Left main bifurcation percutaneous coronary intervention was a particular risk with USD detected in 18.5% of cases.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Diseño de Prótesis , Stents , Tomografía de Coherencia Óptica , Humanos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Masculino , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Persona de Mediana Edad , Anciano , Factores de Riesgo , Europa (Continente) , Factores de Tiempo , Falla de Prótesis , Valor Predictivo de las Pruebas
3.
EuroIntervention ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38752714

RESUMEN

The 2023 European Bifurcation Club (EBC) meeting took place in Warsaw in October, and the latest evidence for the use of intravascular ultrasound (IVUS) and optical coherence tomography (OCT) to optimise percutaneous coronary interventions (PCI) on coronary bifurcation lesions (CBLs) was a major focus. The topic generated deep discussions and general appraisal on the potential benefits of IVUS and OCT in PCI procedures. Nevertheless, despite an increasing recognition of IVUS and OCT capabilities and their recognised central role for guidance in complex CBL and left main PCI, it is expected that angiography will continue to be the primary guidance modality for CBL PCI, principally due to educational and economic barriers. Mindful of the restricted access/adoption of intracoronary imaging for CBL PCI, the EBC board decided to review and describe a series of tips and tricks which can help to optimise angiography-guided PCI for CBLs. The identified key points for achieving an optimal angiography-guided PCI include a thorough analysis of pre-PCI images (computed tomography angiography, multiple angiographic views, quantitative coronary angiography vessel estimation), a systematic application of the technical steps suggested for a given selected technique, an intraprocedural or post-PCI use of stent enhancement and a low threshold for bailout use of intravascular imaging.

4.
Sci Rep ; 14(1): 10028, 2024 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693210

RESUMEN

The benefits of intravascular ultrasonography (IVUS)-guided percutaneous coronary intervention (PCI) in the clinical context of cardiogenic shock (CS) complicating acute myocardial infarction are lacking. We aimed to investigate the impact of IVUS-guided PCI in patients with AMI and CS. From the pooled data based on a series of Korean AMI registries during 2011-2020, we identified 1418 consecutive patients who underwent PCI with second generation drug-eluting stent (DES) for AMI and CS. The primary endpoint was the 1-year rate of target lesion failure (TLF), defined as the composite of cardiac death, target vessel myocardial infarction, and ischemic-driven target lesion revascularization. In total, 294 (20.7%) and 1124 (79.3%) underwent IVUS-guided and angiography-guided PCI with second generation DES implantation, respectively. The 1-year TLF was not significantly different between groups after IPTW analysis (hazard ratio 0.93, 95% confidence interval 0.65-1.34, p = 0.70). Additionally, the adjusted landmark analysis for TLF at 30 days and between 30 days and 1 year after PCI demonstrated no significant difference between the groups. In conclusion, in patients with AMI and CS who underwent PCI with second-generation DES, IVUS-guided PCI did not improve the 1-year TLF compared with angiography-guided PCI.Registration: URL:  http://cris.nih.go.kr . KCT0000863 and KCT0008355.


Asunto(s)
Angiografía Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Choque Cardiogénico , Ultrasonografía Intervencional , Humanos , Intervención Coronaria Percutánea/métodos , Choque Cardiogénico/terapia , Choque Cardiogénico/etiología , Choque Cardiogénico/diagnóstico por imagen , Masculino , Femenino , Ultrasonografía Intervencional/métodos , Infarto del Miocardio/complicaciones , Anciano , Persona de Mediana Edad , Stents Liberadores de Fármacos , Resultado del Tratamiento , Sistema de Registros
5.
Circulation ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38742491

RESUMEN

BACKGROUND: Diffuse coronary artery disease (CAD) impacts the safety and efficacy of percutaneous coronary intervention (PCI). Pathophysiological CAD patterns can be quantified using fractional flow reserve (FFR) pullbacks incorporating the pullback pressure gradient (PPG) calculation. This study aimed to establish the capacity of PPG to predict optimal revascularisation and procedural outcomes. METHODS: This prospective, investigator-initiated, single-arm, multicentre study enrolled patients with at least one epicardial lesion with an FFR ≤ 0.80 scheduled for PCI. Manual FFR pullbacks were employed to calculate PPG. The primary outcome of optimal revascularisation was defined as a post-PCI FFR ≥ 0.88. RESULTS: 993 patients with 1044 vessels were included. The mean FFR was 0.68 ± 0.12, PPG 0.62 ± 0.17, and post-PCI FFR 0.87 ± 0.07. PPG was significantly correlated with the change in FFR after PCI (r=0.65, 95% CI 0.61-0.69, p<0.001) and demonstrated excellent predicted capacity for optimal revascularisation (AUC 0.82, 95% CI 0.79-0.84, p<0.001). Conversely, FFR alone did not predict revascularisation outcomes (AUC 0.54, 95% CI 0.50-0.57). PPG influenced treatment decisions in 14% of patients, redirecting them from PCI to alternative treatment modalities. Periprocedural myocardial infarction occurred more frequently in patients with low PPG (<0.62) compared to those with focal disease (OR 1.71, 95% CI: 1.00-2.97). CONCLUSIONS: Pathophysiological CAD patterns distinctly affect the safety and effectiveness of PCI. The PPG showed an excellent predictive capacity for optimal revascularisation and demonstrated added value compared to a FFR measurement.

6.
Redox Biol ; 73: 103167, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38688060

RESUMEN

Sulfide-releasing compounds reduce reperfusion injury by decreasing mitochondria-derived reactive oxygen species production. We previously characterised ammonium tetrathiomolybdate (ATTM), a clinically used copper chelator, as a sulfide donor in rodents. Here we assessed translation to large mammals prior to clinical testing. In healthy pigs an intravenous ATTM dose escalation revealed a reproducible pharmacokinetic/pharmacodynamic (PK/PD) relationship with minimal adverse clinical or biochemical events. In a myocardial infarction (1-h occlusion of the left anterior descending coronary artery)-reperfusion model, intravenous ATTM or saline was commenced just prior to reperfusion. ATTM protected the heart (24-h histological examination) in a drug-exposure-dependent manner (r2 = 0.58, p < 0.05). Blood troponin T levels were significantly (p < 0.05) lower in ATTM-treated animals while myocardial glutathione peroxidase activity, an antioxidant selenoprotein, was elevated (p < 0.05). Overall, our study represents a significant advance in the development of sulfides as therapeutics and underlines the potential of ATTM as a novel adjunct therapy for reperfusion injury. Mechanistically, our study suggests that modulating selenoprotein activity could represent an additional mode of action of sulfide-releasing drugs.

7.
J Burn Care Res ; 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38666609

RESUMEN

Thermal and chemical burns can result in cicatricial eyelid retraction, characterized by an abnormal resting position of the eyelid margin and increased palpebral fissure height. Eyelid retraction often leads to exposure keratopathy, which can cause complications ranging from mild dry eye to globe-threatening ulceration and perforation. Prompt intervention includes aggressive lubrication, moisture chambers, eyelid tarsorrhaphy and retraction repair surgery. Discussed here is a burn patient with severe cicatricial retraction and ectropion leading to severe exposure keratopathy and infectious corneal ulceration with perforation. The patient required aggressive medical intervention, as well as two surgeries to restore the normal eyelid anatomy to protect the globe.

8.
Interv Cardiol ; 19: e03, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38532946

RESUMEN

Intravascular optical coherence tomography (IVOCT) is a form of intra-coronary imaging that uses near-infrared light to generate high-resolution, cross-sectional, and 3D volumetric images of the vessel. Given its high spatial resolution, IVOCT is well-placed to characterise coronary plaques and aid with decision-making during percutaneous coronary intervention. IVOCT requires significant interpretation skills, which themselves require extensive education and training for effective utilisation, and this would appear to be the biggest barrier to its widespread adoption. Various artificial intelligence-based tools have been utilised in the most contemporary clinical IVOCT systems to facilitate better human interaction, interpretation and decision-making. The purpose of this article is to review the existing and future technological developments in IVOCT and demonstrate how they could aid the operator.

9.
Artículo en Inglés | MEDLINE | ID: mdl-38487961

RESUMEN

BACKGROUND: Current evidence acknowledges guided bone regeneration (GBR) as a predictable therapeutic modality in the augmentation of a deficient alveolar ridge. Such deficiencies often reveal inadequate bone volume to support implant placement in a position amenable to prosthetic reconstruction. Additionally, an evolving body of literature demonstrates that membrane fixation may lead to improved clinical bone gain through positively influencing blood clot formation, stability, and the eventual osteogenic potential of the defect. Alternative benefits to membrane fixation, such as reduced graft displacement and reduction in wound micromotion, have also been cited as mechanisms for an increased regenerative response. METHODS AND RESULTS: The aim of this report was to present a case, including diagnosis, treatment, and follow-up for the reconstruction of a horizontal ridge deficiency. The patient's deficiency in ridge volume was found to be a developmental sequelae of lateral incisor agenesis, resulting in an underdeveloped midfacial region of the alveolar process subjacent to sites #7 and #10. The fixation protocol outlined in this report demonstrated adequate horizontal ridge augmentation to facilitate future prosthetic reconstruction with the use of implants. CONCLUSIONS: Numerous protocols have been established in an attempt to achieve effective barrier membrane stabilization for bone augmentation procedures. However, some techniques are poorly suited for the anatomically challenging region of the anterior maxilla. A case report describing the utilization of the anterior nasal spine for anchorage of a membrane-stabilizing suture may present a novel, safe, and effective technique for stabilizing the intended region of augmentation, as well as preventing graft migration beyond the membrane-maxilla interface. Key points Regarding guided bone regeneration (GBR) procedures, micromotion of the membrane or of the underlying particulate graft may negatively influence the volume of the augmented site. The ability to adequately stabilize the graft-membrane interface is recognized as a necessary prerequisite to predictably achieve optimal surgical outcomes. To the authors' knowledge, there is no clinical or scientific evidence regarding the use of the anterior nasal spine for membrane anchorage in maxillary GBR procedures, and thus a novel approach to membrane stabilization is introduced.

10.
Parasit Vectors ; 17(1): 106, 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38439081

RESUMEN

BACKGROUND: Although whole-genome sequencing (WGS) is the preferred genotyping method for most genomic analyses, limitations are often experienced when studying genomes characterized by a high percentage of repetitive elements, high linkage, and recombination deserts. The Asian tiger mosquito (Aedes albopictus), for example, has a genome comprising up to 72% repetitive elements, and therefore we set out to develop a single-nucleotide polymorphism (SNP) chip to be more cost-effective. Aedes albopictus is an invasive species originating from Southeast Asia that has recently spread around the world and is a vector for many human diseases. Developing an accessible genotyping platform is essential in advancing biological control methods and understanding the population dynamics of this pest species, with significant implications for public health. METHODS: We designed a SNP chip for Ae. albopictus (Aealbo chip) based on approximately 2.7 million SNPs identified using WGS data from 819 worldwide samples. We validated the chip using laboratory single-pair crosses, comparing technical replicates, and comparing genotypes of samples genotyped by WGS and the SNP chip. We then used the chip for a population genomic analysis of 237 samples from 28 sites in the native range to evaluate its usefulness in describing patterns of genomic variation and tracing the origins of invasions. RESULTS: Probes on the Aealbo chip targeted 175,396 SNPs in coding and non-coding regions across all three chromosomes, with a density of 102 SNPs per 1 Mb window, and at least one SNP in each of the 17,461 protein-coding genes. Overall, 70% of the probes captured the genetic variation. Segregation analysis found that 98% of the SNPs followed expectations of single-copy Mendelian genes. Comparisons with WGS indicated that sites with genotype disagreements were mostly heterozygotes at loci with WGS read depth < 20, while there was near complete agreement with WGS read depths > 20, indicating that the chip more accurately detects heterozygotes than low-coverage WGS. Sample sizes did not affect the accuracy of the SNP chip genotype calls. Ancestry analyses identified four to five genetic clusters in the native range with various levels of admixture. CONCLUSIONS: The Aealbo chip is highly accurate, is concordant with genotypes from WGS with high sequence coverage, and may be more accurate than low-coverage WGS.


Asunto(s)
Aedes , Mosquitos Vectores , Humanos , Animales , Genotipo , Mosquitos Vectores/genética , Heterocigoto , Aedes/genética
11.
Am J Cardiol ; 217: 94-101, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38350507

RESUMEN

In the Targeted therapy with a localised abluminal coated, low-dose sirolimus-eluting, biodegreadable polymer coronary stent (TARGET; NCT02520180) All Comers trial the biodegradable polymer (BP) sirolimus-eluting FIREHAWK stent was noninferior to the durable polymer (DP) everolimus-eluting XIENCE stent with respect to target lesion failure (TLF) at 1 and 5 years; however, the long-term safety and efficacy in the setting of acute coronary syndromes (ACS) are not known. We sought to assess the long-term outcomes in ACS versus chronic coronary syndromes (CCS) with BP sirolimus-eluting stent (SES) versus DP everolimus-eluting stent (EES). The TARGET AC study was a multicenter, open-label, noninferiority trial of all comer patients randomly allocated 1:1 to BP SES or DP EES (stratified by ST-elevation myocardial infarction and study site). In this predefined substudy, the outcomes were compared based on clinical presentation (ACS vs CCS) and treatment allocation. A total of 1,653 patients were enrolled (728 with ACS and 922 with CCS), with 94% completing the 5-year follow-up. The baseline characteristics were well-matched between the 2 stent types; however, co-morbidities were more prevalent in the CCS than in the ACS population. TLF (15.5% vs 17.7%, p = 0.24), patient-oriented outcomes (32.0% vs 34.4%, p = 0.31), and stent thrombosis (4.1% vs 3.3%, p = 0.40) were similar between patients with ACS and patients with CCS. In the ACS cohort, the outcomes at 5 years for BP SES versus DP EES were similar for TLF (16.0% vs 14.9%, p = 0.70), ischemia-driven target lesion revascularization (5.6% vs 8.3%, p = 0.17), and definite/probable stent thrombosis (2.7% vs 4.6%, p = 0.18). The same was true for the CCS cohort, with 5-year outcomes for BP SES versus DP EES for TLF (18.0% vs 17.4%, p = 0.82), ischemia-driven target lesion revascularization (6.4% vs 5.0%, p = 0.37), and definite/probable stent thrombosis (3.0% vs 1.8%, p = 0.26). In conclusion, in the TARGET AC trial, 1 in 3 patients had a major adverse event at 5 years, irrespective of CCS or ACS presentation. Long-term, the BP sirolimus-eluting FIREHAWK stent was as safe and effective as the DP everolimus-eluting XIENCE stent across the spectrum of clinical presentations.


Asunto(s)
Síndrome Coronario Agudo , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Trombosis , Humanos , Implantes Absorbibles , Síndrome Coronario Agudo/cirugía , Enfermedad de la Arteria Coronaria/terapia , Everolimus/farmacología , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Diseño de Prótesis , Factores de Riesgo , Sirolimus/farmacología , Sirolimus/uso terapéutico , Infarto del Miocardio con Elevación del ST/etiología , Trombosis/etiología , Resultado del Tratamiento
12.
Clin Exp Dent Res ; 10(1): e849, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38345517

RESUMEN

OBJECTIVES: In periodontology, it is widely recognized that evidence characterizing the incidence and effect of treatment complications is lacking. The objective of this study was to assess the influence of operator-, procedure-, patient-, and site-associated factors on intraoperative and postoperative complication occurrence. MATERIAL AND METHODS: A single investigator reviewed records of patients treated by eight periodontics residents from July 2018 through June 2022. For each procedure, the investigator recorded each intraoperative and postoperative complication or indicated that no complication had occurred. These outcomes were analyzed against a panel of explanatory covariates. In addition, the severity of each postoperative complication was assessed using a standardized grading system. RESULTS: A total of 1135 procedures were included in the analysis. Intraoperative and postoperative complications were identified in 2.8% and 15.2% of procedures, respectively. The most common intraoperative complications were Schneiderian membrane perforation (1.3%) and gingival flap perforation/tear (1%), and the most common postoperative complications were dentin hypersensitivity (2.6%), excessive pain (2.5%), and infection (2.2%). Subepithelial connective tissue graft (odds ratio [OR]: 3.2, 95% confidence interval [CI]: 1.6, 6.1; p < .001), guided bone regeneration (OR: 3.0, 95% CI: 1.4, 6.5; p = .004), and guided bone regeneration with implant placement (OR: 3.1, 95% CI: 1.3, 7.6; p = .011) were associated with higher odds of postoperative complication, whereas lateral sinus elevation (OR: 102.5, 95% CI: 12.3, 852.9; p < .001), transalveolar sinus elevation (OR: 22.4, 95% CI: 2.2, 224.5; p = .008), open flap debridement (OR: 36.4, 95% CI: 3.0, 440.7; p = .005), and surgically facilitated orthodontic therapy (OR: 20.5, 95% CI: 1.2, 358.4; p = .039) were associated with higher odds of intraoperative complication occurrence. CONCLUSIONS: Consistent with previous reports, procedure type appears to be the predominant factor driving complication occurrence. As analyses of treatment complications increase, individualized risk-benefit assessments will become progressively meaningful for patients.


Asunto(s)
Implantes Dentales , Elevación del Piso del Seno Maxilar , Humanos , Elevación del Piso del Seno Maxilar/métodos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Implantación Dental Endoósea , Trasplante Óseo/métodos
13.
Ecol Evol ; 14(2): e10887, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38304275

RESUMEN

Harnessing science-based policy is key to addressing global challenges like the biodiversity and climate crises. Open research principles underpin effective science-based policy, but the uptake of these principles is likely constrained by the politicisation, commoditisation and conflicting motives of stakeholders in the research landscape. Here, using the mission and vision statements from 129 stakeholders from across the research landscape, we explore alignment in open research principles between stakeholders. We find poor alignment between stakeholders, largely focussed around journals, societies and funders, all of which have low open research language-use. We argue that this poor alignment stifles knowledge flow within the research landscape, ultimately limiting the mobilisation of impactful science-based policy. We offer recommendations on how the research landscape could embrace open research principles to accelerate societies' ability to solve global challenges.

14.
EuroIntervention ; 20(3): e216-e223, 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38214677

RESUMEN

The coronary sinus Reducer (CSR) is an hourglass-shaped device which creates an artificial stenosis in the coronary sinus. Whilst placebo-controlled data show an improvement in angina, these results are unreplicated and are the subject of further confirmatory research. The mechanism of action of this unintuitive therapy is unknown. The Coronary Sinus Reducer Objective Impact on Symptoms, MRI Ischaemia, and Microvascular Resistance (ORBITA-COSMIC) trial is a randomised, placebo-controlled, double-blind trial investigating the efficacy of the CSR. Patients with (i) established epicardial coronary artery disease, (ii) angina on maximally tolerated antianginal medication, (iii) evidence of myocardial ischaemia and (iv) no further options for percutaneous coronary intervention or coronary artery bypass grafting will be enrolled. Upon enrolment, angina and quality-of-life questionnaires, treadmill exercise testing and quantitative stress perfusion cardiac magnetic resonance (CMR) imaging will be performed. Participants will record their symptoms daily on a smartphone application throughout the trial. After a 2-week symptom assessment phase, participants will be randomised in the cardiac catheterisation laboratory to CSR or a placebo procedure. After 6 months of blinded follow-up, all prerandomisation tests will be repeated. A prespecified subgroup will undergo invasive coronary physiology assessment at prerandomisation and follow-up. The primary outcome is stress myocardial blood flow on CMR. Secondary outcomes include angina frequency, quality of life and treadmill exercise time. (ClinicalTrials.gov: NCT04892537).


Asunto(s)
Angina Estable , Enfermedad de la Arteria Coronaria , Seno Coronario , Intervención Coronaria Percutánea , Humanos , Angina Estable/diagnóstico , Calidad de Vida , Seno Coronario/cirugía , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/terapia
15.
J Dent Educ ; 88(4): 403-410, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38269493

RESUMEN

PURPOSE/OBJECTIVES: The objectives of this study were to assess the influence of learner- and education-related factors on standardized in-service examination performance and determine whether in-service examination scores predict residency outcomes. METHODS: American Academy of Periodontology (AAP) In-service Examination (AIE) scores from 10 periodontics residency classes at a single center were recorded and compared against a panel of learner- and education-related variables using multiple linear regression models. Defined residency outcome measures were analyzed against AIE scores using binomial logistic regression. RESULTS: No evaluated learner- or education-related variable was a statistically significant predictor of AIE score in this study sample. Likewise, AIE score was not a statistically significant predictor of any assessed residency outcome. CONCLUSIONS: The AAP has performed a tremendous service to periodontics residents and programs by marshaling the leadership and expertise necessary to offer a professionally constructed assessment instrument. However, in the current study, no relationship could be identified between AIE score and any outcome, including first-attempt board certification. The AAP In-service Committee appears well situated to provide additional leadership focusing on exam implementation, which may enhance AIE value in competency decision making.


Asunto(s)
Internado y Residencia , Estados Unidos , Educación de Postgrado en Medicina , Periodoncia , Evaluación Educacional , Competencia Clínica
16.
J Am Heart Assoc ; 13(2): e029051, 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38214256

RESUMEN

BACKGROUND: Patients treated with percutaneous coronary intervention are often considered to be at a high bleeding risk (HBR). Drug-eluting stents have been shown to be superior to bare-metal stents in patients with HBR, even when patients were given abbreviated periods of dual antiplatelet therapy (DAPT). Short DAPT has not been evaluated with the EluNIR ridaforolimus-eluting stent. The aim of this study was to evaluate the safety and efficacy of a shortened period of DAPT following implantation of the ridaforolimus-eluting stent in patients with HBR. METHODS AND RESULTS: This was a prospective, multicenter, binational, single-arm, open-label trial. Patients were defined as HBR according to the LEADERS-FREE (Prospective Randomized Comparison of the BioFreedom Biolimus A9 Drug-Coated Stent versus the Gazelle Bare-Metal Stent in Patients at High Bleeding Risk) trial criteria. After percutaneous coronary intervention, DAPT was given for 1 month to patients presenting with stable angina. In patients presenting with an acute coronary syndrome, DAPT was given for 1 to 3 months, at the investigator's discretion. The primary end point was a composite of cardiac death, myocardial infarction, or stent thrombosis up to 1 year (Academic Research Consortium definite and probable). Three hundred fifteen patients undergoing percutaneous coronary intervention were enrolled, and 56.4% presented with acute coronary syndrome; 33.7% were receiving oral anticoagulation. At 1 year, the primary end point occurred in 15 patients (4.9%), meeting the prespecified performance goal of 14.1% (P<0.0001). Stent thrombosis (Academic Research Consortium definite and probable) occurred in 2 patients (0.6%). Bleeding Academic Research Consortium type 3 and 5 bleeding occurred in 6 patients (1.9%). CONCLUSIONS: We observed favorable results in patients with HBR who underwent percutaneous coronary intervention with a ridaforolimus-eluting stent and received shortened DAPT, including a low rate of ischemic events and low rate of stent thrombosis. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03877848.


Asunto(s)
Síndrome Coronario Agudo , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Sirolimus/análogos & derivados , Trombosis , Humanos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Síndrome Coronario Agudo/tratamiento farmacológico , Estudios Prospectivos , Resultado del Tratamiento , Hemorragia/inducido químicamente , Stents , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Trombosis/etiología , Quimioterapia Combinada , Enfermedad de la Arteria Coronaria/tratamiento farmacológico
17.
Transl Vis Sci Technol ; 13(1): 9, 2024 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-38224327

RESUMEN

Purpose: The Consortium of Student-Led Eye Clinics (CSLEC), founded in 2021, administered a comprehensive survey to document the types of services, most common diagnoses, and follow-up care protocols offered by student-led free vision screening programs (SLFVSP) in the United States. Methods: An 81-question institutional review board (IRB)-approved survey was administered to student-led vision screening eye clinics from October 1, 2022 to February 24, 2023. Results: Sixteen SLFVSPs were included in the final analysis, of which 81% (n = 13) conducted variations of fundoscopic examinations and 75% (n = 12) measured intraocular pressure. Cataracts and diabetic retinopathy were reported as the most frequent diagnoses by the majority of SLFVSPs (n = 9, 56%); non-mobile SLFVSPs more commonly reported cataract as a frequent diagnosis (P < 0.05). Most patients screened at participating programs were uninsured or met federal poverty guidelines. Prescription glasses were offered by 56% of the programs (n = 9). SLFVSPs that directly scheduled follow-up appointments reported higher attendance rates (66.5%) than those that only sent referrals (20%). Transportation was the most cited barrier for follow-up appointment attendance. Conclusions: SLFVSPs, one community vision screening initiative subtype, vary significantly in scope and capabilities of identifying vision threatening disease. The follow-up infrastructure is not uniformly robust and represents a key target for improving care delivery to at-risk populations. Translational Relevance: The CSLEC aims to develop a consensus-based standardization for the scope of screening services, offer guidelines for diagnostic criteria, promote real-time data stewardship, and identify means to improve follow-up care mechanisms in member communities.


Asunto(s)
Catarata , Retinopatía Diabética , Selección Visual , Humanos , Estados Unidos/epidemiología , Examen Físico , Catarata/diagnóstico , Catarata/epidemiología , Presión Intraocular
18.
Ophthalmic Plast Reconstr Surg ; 40(1): e14-e16, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38241629

RESUMEN

Orbital abscesses are rarely encountered in children younger than 1 year. The literature is limited to isolated case reports and a few case series. Most such cases are reported in infants born at term, with the earliest reported gestational birth age at 34 weeks. Children are more prone to orbital cellulitis compared with adults due to their underdeveloped sinuses and immature immune systems, and the origin is most commonly an ethmoid sinus infection. Orbital cellulitis secondary to dacryocystitis is even less common, with only a few isolated cases reported in infants and children. Herein, the authors present a case of a large extraconal and intraconal orbital abscess secondary to nasolacrimal duct obstruction and dacryocystitis in an extremely preterm infant. We discuss the diagnosis and multidisciplinary management of this challenging case.


Asunto(s)
Dacriocistitis , Dacriocistorrinostomía , Obstrucción del Conducto Lagrimal , Conducto Nasolagrimal , Celulitis Orbitaria , Lactante , Adulto , Niño , Humanos , Recién Nacido , Obstrucción del Conducto Lagrimal/diagnóstico , Obstrucción del Conducto Lagrimal/etiología , Celulitis Orbitaria/etiología , Celulitis Orbitaria/complicaciones , Dacriocistorrinostomía/efectos adversos , Recien Nacido Extremadamente Prematuro , Absceso/complicaciones , Absceso/diagnóstico , Dacriocistitis/complicaciones , Dacriocistitis/diagnóstico
19.
Biotechnol Bioeng ; 121(2): 618-639, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37947118

RESUMEN

The recent uptick in the approval of ex vivo cell therapies highlights the relevance of lentivirus (LV) as an enabling viral vector of modern medicine. As labile biologics, however, LVs pose critical challenges to industrial biomanufacturing. In particular, LV purification-currently reliant on filtration and anion-exchange or size-exclusion chromatography-suffers from long process times and low yield of transducing particles, which translate into high waiting time and cost to patients. Seeking to improve LV downstream processing, this study introduces peptides targeting the enveloped protein Vesicular stomatitis virus G (VSV-G) to serve as affinity ligands for the chromatographic purification of LV particles. An ensemble of candidate ligands was initially discovered by implementing a dual-fluorescence screening technology and a targeted in silico approach designed to identify sequences with high selectivity and tunable affinity. The selected peptides were conjugated on Poros resin and their LV binding-and-release performance was optimized by adjusting the flow rate, composition, and pH of the chromatographic buffers. Ligands GKEAAFAA and SRAFVGDADRD were selected for their high product yield (50%-60% of viral genomes; 40%-50% of HT1080 cell-transducing particles) upon elution in PIPES buffer with 0.65 M NaCl at pH 7.4. The peptide-based adsorbents also presented remarkable values of binding capacity (up to 3·109 TU per mL of resin, or 5·1011 vp per mL of resin, at the residence time of 1 min) and clearance of host cell proteins (up to a 220-fold reduction of HEK293 HCPs). Additionally, GKEAAFAA demonstrated high resistance to caustic cleaning-in-place (0.5 M NaOH, 30 min) with no observable loss in product yield and quality.


Asunto(s)
Lentivirus , Estomatitis Vesicular , Animales , Humanos , Lentivirus/genética , Lentivirus/metabolismo , Células HEK293 , Péptidos/metabolismo , Vesiculovirus/genética , Vectores Genéticos
20.
Biotechnol J ; 19(1): e2300230, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37728197

RESUMEN

Adeno-associated viruses (AAVs) have acquired a central role in modern medicine as delivery agents for gene therapies targeting rare diseases. While new AAVs with improved tissue targeting, potency, and safety are being introduced, their biomanufacturing technology is lagging. In particular, the AAV purification pipeline hinges on protein ligands for the affinity-based capture step. While featuring excellent AAV binding capacity and selectivity, these ligands require strong acid (pH <3) elution conditions, which can compromise the product's activity and stability. Additionally, their high cost and limited lifetime has a significant impact on the price tag of AAV-based therapies. Seeking to introduce a more robust and affordable affinity technology, this study introduces a cohort of peptide ligands that (i) mimic the biorecognition activity of the AAV receptor (AAVR) and anti-AAV antibody A20, (ii) enable product elution under near-physiological conditions (pH 6.0), and (iii) grant extended reusability by withstanding multiple regenerations. A20-mimetic CYIHFSGYTNYNPSLKSC and AAVR-mimetic CVIDGSQSTDDDKIC demonstrated excellent capture of serotypes belonging to distinct clones/clades - namely, AAV1, AAV2, AAV5, AAV6, AAV8, and AAV9. This corroborates the in silico models documenting their ability to target regions of the viral capsid that are conserved across all serotypes. CVIDGSQSTDDDKIC-Toyopearl resin features binding capacity (≈1014 vp mL-1 ) and product yields (≈60%-80%) on par with commercial adsorbents, and purifies AAV2 from HEK293 and Sf9 cell lysates with high recovery (up to 78%), reduction of host cell proteins (up to 700-fold), and high transduction activity (up to 65%).


Asunto(s)
Cápside , Dependovirus , Humanos , Dependovirus/genética , Cápside/química , Células HEK293 , Transducción Genética , Péptidos/metabolismo , Ligandos , Cromatografía de Afinidad , Vectores Genéticos/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...