Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
J Clin Med ; 13(5)2024 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-38592116

RESUMEN

Background: This study aimed to evaluate the accuracy of bone cuts and implant placements, simultaneously, for total knee arthroplasty (TKA) performed using a system with an active robotic arm. Methods: Two experienced orthopaedic surgeons performed TKA on ten cadaveric legs. Computed tomography scans were performed to compare the bone cuts and implant placements with the preoperative planning. The differences between the planned and actual bone cuts and implant placements were assessed using positional and angular errors in the three anatomical planes. Additionally, the cut-implant deviations were calculated. Statistical analysis was performed to detect systematic errors in the bone cuts and implant placements and to quantify the correlations between these errors. Results: The root-mean-square (RMS) errors of the bone cuts (with respect to the planning) were between 0.7-1.5 mm and 0.6-1.7°. The RMS implant placement errors (with respect to the planning) varied between 0.6-1.6 mm and 0.4-1.5°, except for the femur and tibia in the sagittal plane (2.9°). Systematic errors in the bone cuts and implant placements were observed, respectively, in three and two degrees of freedom. For cut-implant deviations, the RMS values ranged between 0.3-2.0 mm and 0.6-1.9°. The bone cut and implant placement errors were significantly correlated in eight degrees-of-freedom (ρ ≥ 0.67, p < 0.05). Conclusions: With most of the errors below 2 mm or 2°, this study supported the value of active robotic TKA in achieving accurate bone cuts and implant placements. The findings also highlighted the need for both accurate bone cuts and proper implantation technique to achieve accurate implant placements.

2.
Front Hum Neurosci ; 18: 1269772, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38524921

RESUMEN

Background: Turning during walking and volitionally modulating walking speed introduces complexity to gait and has been minimally explored. Research question: How do the spatiotemporal parameters vary between young adults walking at a normal speed and a slower speed while making 90°, 180°, and 360° turns? Methods: In a laboratory setting, the spatiotemporal parameters of 10 young adults were documented as they made turns at 90°, 180°, and 360°. A generalized linear model was utilized to determine the effect of both walking speed and turning amplitude. Results: Young adults volitionally reducing their walking speed while turning at different turning amplitudes significantly decreased their cadence and spatial parameters while increasing their temporal parameters. In conditions of slower movement, the variability of certain spatial parameters decreased, while the variability of some temporal parameters increased. Significance: This research broadens the understanding of turning biomechanics in relation to volitionally reducing walking speed. Cadence might be a pace gait constant synchronizing the rhythmic integration of several inputs to coordinate an ordered gait pattern output. Volition might up-regulate or down-regulate this pace gait constant (i.e., cadence) which creates the feeling of modulating walking speed.

3.
Eur J Pain ; 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38299715

RESUMEN

BACKGROUND: The need to improve spinal motor behaviour in chronic low back pain (CLBP) rehabilitation remains unclear. The objective of this study was to test if changes in spinal motor behaviour were associated with changes in disability after an interdisciplinary rehabilitation program (IRP) in patients with CLBP. METHODS: Seventy-one patients with CLBP participating in an IRP were included. Spinal motor behaviour was assessed with biomechanical (lumbar angular amplitude and velocity, erector spinae muscle activity and duration of the task), cognitive-emotional (task-specific fear [PRF]) and pain-related (movement-evoked pain [MEP]) measures during a lifting task before and after the IRP. Disability was measured before and after the IRP, and at 3-month and 1-year follow-ups. RESULTS: After adjusting for confounders, changes in disability were significantly associated with MEP changes (ß adj. = 0.49, p < 0.001) and PRF changes (ß adj. = 0.36, p = 0.008), but not with changes in any of the biomechanical measures. MEP at the end of IRP was also associated with disability at 3 months (ß adj. = 0.37, p = 0.001) and 1 year (ß adj. = 0.42, p = 0.01). Biomechanical measures at the end of the IRP were not associated with disability, except for the duration of the task that was significantly associated with reduction of disability at 3 months (ß non-adj = 0.5, p < 0.001). CONCLUSIONS: Pain-related and cognitive-emotional measures of spinal motor behaviour were associated with reduction in disability following an IRP. Future research is needed to further investigate causal relationships between spinal motor behaviour and disability. SIGNIFICANCE STATEMENT: This study supports a multidimensional understanding and analysis of spinal motor behaviour, integrating the cognitive-emotional, pain-related and biomechanical domains. It also supports the consideration of spinal motor behaviour as a potentially important treatment target in chronic low back pain management. Moreover, it suggests that reducing movement-evoked pain and task-specific fear may have more influence on disability than changing lumbar amplitude, lumbar angular velocity or erector muscle activity, which may have important implications for rehabilitation.

4.
J Clin Med ; 12(16)2023 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-37629350

RESUMEN

According to the World Health Organization (WHO), musculoskeletal conditions are among the most common health problems, affecting approximately 1 [...].

5.
Bioengineering (Basel) ; 10(7)2023 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-37508776

RESUMEN

Sterilization is a prerequisite for biomedical devices before contacting the human body. It guarantees the lack of infection by eliminating microorganisms (i.e., bacteria, spores and fungi). It constitutes the last fabrication process of a biomedical device. The aim of this paper is to understand the effect of different sterilization methods (ethanol-EtOH, autoclave-AC, autoclave + ultraviolet radiation-ACUV and gamma irradiation-G) on the surface chemistry and electrochemical reactivity (with special attention on the kinetics of the oxygen reduction reaction) of CoCrMo and titanium biomedical alloys used as prosthetic materials. To do that, electrochemical measurements (open circuit potential, polarization resistance, cathodic potentiodynamic polarization and electrochemical impedance spectroscopy) and surface analyses (Auger Electron Spectroscopy) of the sterilized surfaces were carried out. The obtained results show that the effect of sterilization on the corrosion behavior of biomedical alloys is material-dependent: for CoCrMo alloys, autoclave treatment increases the thickness and the chromium content of the passive film increasing its corrosion resistance compared to simple sterilization in EtOH, while in titanium and its alloys, autoclave and UV-light accelerates its corrosion rate by accelerating the kinetics of oxygen reduction.

6.
Front Bioeng Biotechnol ; 11: 1176471, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37383522

RESUMEN

Objective: To characterize ambulatory knee moments with respect to medial knee osteoarthritis (OA) severity comprehensively and to assess the possibility of developing a severity index combining knee moment parameters. Methods: Nine parameters (peak amplitudes) commonly used to quantify three-dimensional knee moments during walking were analyzed for 98 individuals (58.7 ± 9.2 years old, 1.69 ± 0.09 m, 76.9 ± 14.5 kg, 56% female), corresponding to three medial knee osteoarthritis severity groups: non-osteoarthritis (n = 22), mild osteoarthritis (n = 38) and severe osteoarthritis (n = 38). Multinomial logistic regression was used to create a severity index. Comparison and regression analyses were performed with respect to disease severity. Results: Six of the nine moment parameters differed statistically significantly among severity groups (p ≤ 0.039) and five reported statistically significant correlation with disease severity (0.23 ≤ |r| ≤ 0.59). The proposed severity index was highly reliable (ICC = 0.96) and statistically significantly different between the three groups (p < 0.001) as well as correlated with disease severity (r = 0.70). Conclusion: While medial knee osteoarthritis research has mostly focused on a few knee moment parameters, this study showed that other parameters differ with disease severity. In particular, it shed light on three parameters frequently disregarded in prior works. Another important finding is the possibility of combining the parameters into a severity index, which opens promising perspectives based on a single figure assessing the knee moments in their entirety. Although the proposed index was shown to be reliable and associated with disease severity, further research will be necessary particularly to assess its validity.

7.
J Clin Med ; 12(5)2023 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-36902803

RESUMEN

Using insoles to modify walking biomechanics is of keen interest for the treatment of medial-compartment knee osteoarthritis. So far, insole interventions have focused on reducing the peak of the knee adduction moment (pKAM) and have led to inconsistent clinical outcomes. This study aimed to evaluate the changes in other gait variables related to knee osteoarthritis when patients walk with different insoles to provide insights into the necessity to enlarge the biomechanical analyses to other variables. Walking trials were recorded for 10 patients in four insole conditions. Changes among conditions were computed for six gait variables, including the pKAM. The associations between the changes in pKAM and the changes in the other variables were also assessed individually. Walking with different insoles had noticeable effects on the six gait variables, with high heterogeneity among patients. For all variables, at least 36.67% of the changes were of medium-to-large effect size. The associations with the changes in pKAM varied among variables and patients. In conclusion, this study showed that varying the insole could globally influence ambulatory biomechanics and that limiting measurement to the pKAM could lead to an important loss of information. Beyond the consideration of additional gait variables, this study also encourages personalized interventions to address inter-patient variability.

8.
J Biomech ; 147: 111449, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36680887

RESUMEN

Walking with a shorter stride length (SL) was recently proposed for gait retraining in medial knee osteoarthritis; however it was never assessed in this patient population. This study tested the hypothesis that shortening SL while maintaining walking speed reduces knee adduction (KAM) and flexion (KFM) moments in patients with medial knee osteoarthritis. Walking trials with normal SL and SL reduced by 0.10 m and 0.15 m were recorded for 15 patients (10 men, 55.5 ± 8.7 years old, 24.6 ± 3.0 kg/m2). SL was modified using an augmented reality system displaying target footprints on the floor. Repeated one-way ANOVAs and post-hoc paired t-tests were performed to compare gait measures between normal and reduced SL. The individual effects of SL reduction were analyzed using descriptive statistics. Group analysis indicated significant decreases in KAM impulse with both SL reductions (p < 0.05). No systematic change was observed in the first peaks KAM and KFM when walking with reduced SL (p > 0.05). Individually, 33 % of the patients decreased the peak KAM, whereas 20 % decreased the KAM impulse. Among these patients with a decrease in peak KAM or in KAM impulse, 0 % and 33 % had a simultaneous increase in peak KFM, respectively. In conclusion, this study showed that SL shortening can decrease kinetic measures associated with the progression of medial knee osteoarthritis in some patients, demonstrating the importance of considering SL modifications on an individual basis. While further research is necessary, notably regarding dose-response relationships and long-term effects, these findings are particularly encouraging because SL reductions could be easily integrated into rehabilitation protocols.


Asunto(s)
Osteoartritis de la Rodilla , Humanos , Masculino , Persona de Mediana Edad , Análisis de Varianza , Fenómenos Biomecánicos , Marcha/fisiología , Articulación de la Rodilla/fisiología , Caminata/fisiología , Femenino
9.
Gait Posture ; 99: 152-159, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36446222

RESUMEN

BACKGROUND: Turning during walking adds complexity to gait and has been little investigated until now. Research question What are the differences in spatiotemporal parameters between young and elderly healthy adults performing quarter-turns (90°), half-turns (180°) and full-turns (360°)? METHODS: The spatiotemporal parameters of 10 young and 10 elderly adults were recorded in a laboratory while turning at 90°, 180° and 360°. Two-way mixed ANOVA were performed to determine the effect of age and turning amplitude. RESULTS: Elderly were slower and needed more steps and time to perform turns of larger amplitude than young adults. Cadence did not differ across age or across turning amplitude. Generally, in the elderly, the spatial parameters were smaller and the temporal parameters enhancing stability (i.e., double-support phase and stance/cycle ratio) were larger, especially for turns of larger amplitudes. In elderly adults, the variability of some spatial parameters was decreased, whereas the variability of some temporal parameters was increased. Stride width of the external leg showed the most substantial difference between groups. Most parameters differed between turning at 90° and turning at larger amplitudes (180°, 360°). Significance This study extends the characterization of turning biomechanics with respect to ageing. It also suggested paying particular attention to the turning amplitude. Finally, the age-related differences may pave the way for new selective rehabilitation protocols in the elderly.


Asunto(s)
Marcha , Caminata , Adulto Joven , Humanos , Anciano , Fenómenos Biomecánicos , Envejecimiento
10.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 1043-1052, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36335473

RESUMEN

PURPOSE: There is a paucity of data available on total knee prostheses combining dual-radius, ultra-congruency, posterior-stabilization and mobile-bearing insert. This prospective cohort study aimed to assess the clinical evolution of the FIRST® prosthesis (Symbios Orthopédie, Yverdon, CH), the earliest prosthesis with this particular design. It was hypothesized that the primary outcomes, evaluating pain, stiffness, function and stability, would improve following arthroplasty and remain improved during the follow-up period of 10 years. METHODS: All patients programmed for a total knee arthroplasty using a FIRST® prosthesis at our university hospital between 2006 and 2008 were invited to participate. Study knees were evaluated pre-operatively as well as one, five and ten years post-operatively. Patients filled out questionnaires at each evaluation point and had a radiographic assessment at the five-year and ten-year follow-ups. Primary outcomes were the total, pain, stiffness and function measures of the Western Ontario and McMaster Universities Osteoarthritis questionnaire (WOMAC) and the knee and function measures of the Knee Society Score (KSS). Friedman and Wilcoxon's rank-sum tests were used to compare measures across time points. RESULTS: Hundred and twenty four prostheses were included (baseline demographics: 69.9 ± 8.3 years old, 28.1 ± 4.3 kg/m2, 54% male) and 68 could be followed during ten years. Five prostheses underwent a revision. All other prostheses lost at follow-up were lost for reasons unrelated to the prosthesis. All primary measures reported statistically and clinically significant improvements between baseline and the three follow-up evaluations. Statistically significant improvements at the three follow-up evaluations were also observed for most secondary measures. There was no implant loosening. At ten-year follow-up, radiolucent lines were observed in 2.9% femoral implants and 1.5% tibial implants. CONCLUSION: The positive results observed in all domains of assessment and the small revision rate demonstrated an effective functioning of the FIRST® prosthesis during the ten-year follow-up period. The results, globally similar to those previously published for other prosthesis designs, encourage the development of assistive methods to select the most appropriate designs on an individual basis. LEVEL OF EVIDENCE: IV, prospective cohort study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Artroplastia de Reemplazo de Rodilla/métodos , Estudios de Seguimiento , Estudios Prospectivos , Radio (Anatomía)/cirugía , Osteoartritis de la Rodilla/cirugía , Diseño de Prótesis , Dolor/cirugía , Falla de Prótesis , Resultado del Tratamiento , Rango del Movimiento Articular
11.
Pain Pract ; 23(3): 290-300, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36479806

RESUMEN

BACKGROUND AND AIMS: While a causal relationship between pain-related fear and spinal movement avoidance in patients with chronic low back pain (CLBP) has frequently been postulated, evidence supporting this relationship is limited. This study aimed to test if decreases in pain-related fear or catastrophizing were associated with improvements in spinal biomechanics, accounting for possible changes in movement-evoked pain. METHODS: Sixty-two patients with CLBP were assessed before and after an interdisciplinary rehabilitation program (IRP). Pain-related fear was assessed with general and task-specific measures. Lower and upper lumbar angular amplitude and velocity as well as paraspinal muscle activity were recorded during five daily-life tasks to evaluate spinal biomechanics. Relationships were tested with multivariable linear regression analyses. RESULTS: The large decreases in pain-related fear and catastrophizing following the IRP were scarcely and inconsistently associated with changes in spinal biomechanics (< 3% of the models reported a statistically significant association). Results remained comparable for activities inducing more or less fear, for specific or general measures of pain-related fear, and for analyses performed on the entire population or limited to subgroups of patients with higher levels of task-specific fear. In contrast, reductions in task-specific pain-related fear were significantly associated with decreases in movement-evoked pain in all tasks (r = 0.26-0.62, p ≤ 0.02). CONCLUSION: This study does not support an association between pain-related fear and spinal movement avoidance. However, it provides evidence supporting a direct relationship between decreased pain-related fear and decreased movement-evoked pain, possibly explaining some mechanisms of the rehabilitation programs.


Asunto(s)
Dolor de la Región Lumbar , Humanos , Dolor de la Región Lumbar/complicaciones , Fenómenos Biomecánicos , Dimensión del Dolor , Miedo , Evaluación de la Discapacidad
12.
Gait Posture ; 95: 100-108, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35468488

RESUMEN

BACKGROUND: Longitudinal research is required to better understand the role of spinal movement alterations in chronic low back pain (CLBP). To this end, it is critical to assess the between-session reliability of spinal movement measures. RESEARCH QUESTION: What is the within/between-session reliability of spinal movement measures in patients with CLBP and asymptomatic controls? METHODS: Spinal movement was recorded prospectively during two sessions, a week apart, for 20 patients with CLBP (60% male; 40.0 ± 12.3 years old) and 20 asymptomatic individuals (55% male; 38.2 ± 10.9 years old). Sagittal-plane angular amplitude and angular velocity at the lower lumbar, upper lumbar, lower thoracic and upper thoracic joints, as well as maximal erector spinae activity were measured during five daily-activity tasks. In addition, task-independent measures were obtained by averaging the measures across tasks. The Intraclass Correlation Coefficient (ICC 2,1) and the minimal detectable change (MDC) were calculated. Pearson correlation was used to compare task-independent and task-specific measures. RESULTS: Between-session ICCs in patients with CLBP were mostly moderate to good for maximal angular amplitude and erector spinae activity measures. Lower ICCs were observed for range of angular motion and angular velocity measures (42% of ICCs < 0.5). Median MDCs were 9.6°, 18.3°/s and 1.0% for angular amplitude, angular velocity and erector spinae activity measures, respectively. The reliability of task-independent and task-specific measures was strongly correlated (r = 0.91, p < 0.001). SIGNIFICANCE: Sagittal-plane maximal angular amplitude and erector spinae activity measures during various daily-activity tasks demonstrated mostly moderate to good between-session ICCs. However, relatively large MDCs suggested that important changes are needed to be detectable. Task-independent measures reported similarly acceptable ICCs than task-specific measures, supporting their use to describe spinal movement.


Asunto(s)
Dolor de la Región Lumbar , Adulto , Fenómenos Biomecánicos , Electromiografía , Femenino , Humanos , Vértebras Lumbares/fisiología , Masculino , Persona de Mediana Edad , Músculo Esquelético/fisiología , Músculos Paraespinales , Rango del Movimiento Articular/fisiología , Reproducibilidad de los Resultados
13.
Materials (Basel) ; 15(5)2022 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-35268957

RESUMEN

In this study, we report results of the interaction of titanium (Ti) with human synovial fluids. A wide palette of electrochemical techniques was used, including open circuit potential, potentiodynamic methods, and electrochemical impedance. After the electrochemical testing, selected surfaces were analyzed using Auger Electron Spectroscopy to provide laterally resolved information on surface chemistry. For comparison purposes, similar tests were conducted in a series of simulated body fluids. This study shows that compared to the tested simulated body fluids, synovial liquids show a large patient variability up to one order of magnitude for some crucial electrochemical parameters such as corrosion current density. The electrochemical behavior of Ti exposed to human synovial fluids seems to be controlled by the interaction with organic molecules rather than with reactive oxygen species.

14.
J Clin Med ; 11(3)2022 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-35160002

RESUMEN

As knee osteoarthritis is a disease of the entire joint, our pathophysiological understanding could be improved by the characterization of the relationships among the knee components. Diverse quantitative parameters can be characterized using magnetic resonance imaging (MRI) and computed tomography (CT). However, a lack of methods for the coordinated measurement of multiple parameters hinders global analyses. This study aimed to design an expert-supervised registration method to facilitate multiparameter description using complementary image sets obtained by serial imaging. The method is based on three-dimensional tissue models positioned in the image sets of interest using manually placed attraction points. Two datasets, with 10 knees CT-scanned twice and 10 knees imaged by CT and MRI were used to assess the method when registering the distal femur and proximal tibia. The median interoperator registration errors, quantified using the mean absolute distance and Dice index, were ≤0.45 mm and ≥0.96 unit, respectively. These values differed by less than 0.1 mm and 0.005 units compared to the errors obtained with gold standard methods. In conclusion, an expert-supervised registration method was introduced. Its capacity to register the distal femur and proximal tibia supports further developments for multiparameter description of healthy and osteoarthritic knee joints, among other applications.

15.
Front Bioeng Biotechnol ; 9: 767974, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34869281

RESUMEN

Despite a large body of evidence demonstrating spinal movement alterations in individuals with chronic low back pain (CLBP), there is still a lack of understanding of the role of spinal movement behavior on LBP symptoms development or recovery. One reason for this may be that spinal movement has been studied during various functional tasks without knowing if the tasks are interchangeable, limiting data consolidation steps. The first objective of this cross-sectional study was to analyze the influence of the functional tasks on the information carried by spinal movement measures. To this end, we first analyzed the relationships in spinal movement between various functional tasks in patients with CLBP using Pearson correlations. Second, we compared the performance of spinal movement measures to differentiate patients with CLBP from asymptomatic controls among tasks. The second objective of the study was to develop task-independent measures of spinal movement and determine the construct validity of the approach. Five functional tasks primarily involving sagittal-plane movement were recorded for 52 patients with CLBP and 20 asymptomatic controls. Twelve measures were used to describe the sagittal-plane angular amplitude and velocity at the lower and upper lumbar spine as well as the activity of the erector spinae. Correlations between tasks were statistically significant in 91 out of 99 cases (0.31 ≤ r ≤ 0.96, all p < 0.05). The area under the curve (AUC) to differentiate groups did not differ substantially between tasks in most of the comparisons (82% had a difference in AUC of ≤0.1). The task-independent measures of spinal movement demonstrated equivalent or higher performance to differentiate groups than functional tasks alone. In conclusion, these findings support the existence of an individual spinal movement signature in patients with CLBP, and a limited influence of the tasks on the information carried by the movement measures, at least for the twelve common sagittal-plane measures analysed in this study. Therefore, this work brought critical insight for the interpretation of data in literature reporting differing tasks and for the design of future studies. The results also supported the construct validity of task-independent measures of spinal movement and encouraged its consideration in the future.

16.
Eur J Phys Rehabil Med ; 57(6): 948-958, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34468109

RESUMEN

INTRODUCTION: There is lack of understanding of the relationship between knee adduction moment (KAM) reductions and improvements in pain or function in patients with knee osteoarthritis (KOA). Moreover, there is no systematic review describing the longitudinal relationship between KAM changes and subsequent changes in pain and/or physical function. WE AIMED TO: 1) investigate the relationship between changes in KAM induced by non-surgical biomechanical interventions and consecutive changes in pain and/or physical function in patients with medial KOA and; 2) compare this relationship for different interventions. EVIDENCE ACQUISITION: We considered eligible all RCTs using biomechanical interventions aimed to reduce KAM in KOA patients, that measured pain/function. We used Cohen's d effect size to quantify outcome measurements. EVIDENCE SYNTHESIS: Fourteen papers reporting 11 studies were identified. Braces were tested in 6 studies, insoles in 5 studies, shoes in 3 studies and gait retraining in 2 studies. Methodological differences were large among studies. Large effect sizes (≥0.8) changes in pain/function were observed with interventions having at least a small KAM effect size (≥0.2), suggesting an association between KAM and pain/function changes. A linear trend was observed between inter-intervention KAM and VAS pain effect sizes, based on 4 studies. No firm conclusions could be drawn for the different intervention types. CONCLUSIONS: There was a trend toward larger KAM reductions leading to larger improvements in pain/function in non-surgical biomechanical interventions. Additional high-quality RCT with consistent methodology are needed to fully characterize the association between KAM and pain/function changes.


Asunto(s)
Osteoartritis de la Rodilla , Tirantes , Marcha , Humanos , Articulación de la Rodilla , Dolor
17.
J Clin Med ; 10(16)2021 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-34442008

RESUMEN

INTRODUCTION: This study aimed to assess the bone cuts accuracy of a system for total knee arthroplasty including an active robotic arm. A second objective was to compare the accuracy among orthopaedic surgeons of different levels of experience. METHODS: Three orthopaedic surgeons cut 10 sawbone knees each. Planned and actual bone cuts were compared using computed tomography. Difference with respect to the planning was expressed as three position and three orientation errors following the anatomical planes. Statistical tests were performed to detect bias and compare surgeons. RESULTS: None of the 30 knees presented an outlier error, meaning an error ≥3 mm or ≥3°. The root-mean-square values of the 12 error types were below 0.8 mm or 0.8°, except for the femoral proximal-distal errors (1.7 mm) and the tibial anterior-posterior errors (1.4 mm). Biases were observed, particularly in femoral proximal-distal and tibial anterior-posterior positions. Median differences between surgeons were all lower than 0.8 mm and 0.5°, with statistically significant differences among surgeons in the femoral proximal-distal errors and the tibial anterior-posterior errors. CONCLUSIONS: The system tested in this study achieved accurate bone cuts independently of the surgeon's level of experience. Biases were observed, suggesting that there might be options to improve the accuracy, particularly in proximal-distal position for the femur and in anterior-posterior position for the tibia.

18.
J Clin Med ; 10(6)2021 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-33801000

RESUMEN

This study tested for longitudinal changes in femoral cartilage T2 relaxation time and thickness in fast-progressing medial femorotibial osteoarthritis (OA). From the Osteoarthritis Initiative (OAI) database, nineteen knees fulfilled the inclusion criteria, which included medial femorotibial OA and sequential progression from Kellgren-Lawrence grade (KL) 1 to KL2 to KL3 within five years. Median T2 value and mean thickness were calculated for six condylar volumes of interest (VOIs; medial/lateral anterior, central, posterior) and six sub-VOIs (medial/lateral anterior external, central, internal). T2 value and thickness changes between severity timepoints were tested using repeated statistics. T2 values increased between KL1 and KL2 and between KL1 and KL3 in the medial compartment (p ≤ 0.02), whereas both increases and decreases were observed between the same timepoints in the lateral compartment (p ≤ 0.02). Cartilage thickness decreased in VOI/subVOIs of the medial compartment from KL1 to KL2 and KL3 (p ≤ 0.014). Cartilage T2 value and thickness changes varied spatially over the femoral condyles. While all T2 changes occurred in the early radiographic stages of OA, thickness changes occurred primarily in the later stages. These data therefore support the use of T2 relaxation time analyses in methods of detecting disease-related change during early OA, a valuable period for therapeutic interventions.

19.
J Orthop Surg Res ; 16(1): 188, 2021 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-33722256

RESUMEN

BACKGROUND: Total knee arthroplasty (TKA) is most frequently planned using conventional two-dimensional weight-bearing lower limb radiographs and is performed with conventional femoral and tibial cutting guides. Questions have been raised about the accuracy of conventional TKA instrumentation and planning for an anatomically standard or complex joint. Use of computed tomography (CT)-based three-dimensional (3D) templating and patient-specific cutting guides printed in 3D has shown improved postoperative lower limb alignment parameters. This case-control study compared costs and operative times of using CT-based, patient-specific, single-use instruments versus conventional metal instruments for TKA. METHODS: In this case-control, retrospective chart review, all TKAs were performed by one senior surgeon, using the F.I.R.S.T. posterior-stabilised knee prosthesis (Symbios, CH), with a similar protocol and identical operating room setup. Group A included 51 TKAs performed with patient-specific cutting guides and conventional metal instruments. Group B included 49 TKAs performed with patient-specific cutting guides and patient-specific, single-use instrumentation. Operation duration, number of instrumentation trays and sterilisation costs were evaluated. RESULTS: The groups were similar for age, body mass index, hip-knee-ankle angle and operation duration. The mean number of instrumentation trays was 8.0 ± 0.8 for group A (controls) and 5.1 ± 0.9 for group B (p<0.001). The mean sterilisation costs were 380 ± 47 Swiss Francs (CHF) for group A and 243 ± 55 CHF for group B (p<0.001), for a mean cost reduction of 130.50 CHF per intervention in group B. The time interval between two consecutive surgeries was 24 min for group A and 18 min for group B. There were no adverse events or complications, instrument-related or otherwise. CONCLUSION: Compared to conventional instrumentation, use of patient-specific, single-use instruments for TKA reduced the number of instrumentation trays by more than one-third and saved 36% in sterilisation costs. If fabrication costs of single-use instruments are included by the company, the total cost is significantly diminished. There was no operative time advantage for single-use instrumentation.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/economía , Artroplastia de Reemplazo de Rodilla/instrumentación , Costos y Análisis de Costo , Equipos Desechables , Esterilización/economía , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Equipos Desechables/economía , Femenino , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Tempo Operativo , Estudios Retrospectivos , Tibia/diagnóstico por imagen , Tibia/cirugía , Tomografía Computarizada por Rayos X
20.
Pain ; 162(3): 672-686, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33591109

RESUMEN

ABSTRACT: This meta-analysis investigated whether more negative psychological factors are associated with less spinal amplitude of movement and higher trunk muscle activity in individuals with low back pain. Furthermore, it examined whether pain intensity was a confounding factor in this relationship. We included studies that provided at least 1 correlation coefficient between psychological (pain-related fear, catastrophizing, depression, anxiety, and self-efficacy) and spinal motor behaviour (spinal amplitude and trunk muscle activity) measures. In total, 52 studies (3949 participants) were included. The pooled correlation coefficients (95% confidence interval; number of participants) were -0.13 (-0.18 to -0.09; 2832) for pain-related fear, -0.16 (-0.23 to -0.09; 756) for catastrophizing, -0.08 (-0.13 to -0.03; 1570) for depression, -0.08 (-0.30 to 0.14; 336) for anxiety, and -0.06 (-0.46 to 0.36; 66) for self-efficacy. The results indicated that higher levels of pain-related fear, catastrophizing, and depression are significantly associated with reduced amplitudes of movement and larger muscle activity and were consistent across subgroup and moderation analyses. Pain intensity did not significantly affect the association between these psychological factors and spinal motor behaviour and had a very small independent association with spinal motor behaviour. In conclusion, the very small effect sizes found in the meta-analyses question the role of psychological factors as major causes of spinal movement avoidance in low back pain. Experimental studies with more specific and individualized measures of psychological factors, pain intensity, and spinal motor behaviour are recommended.


Asunto(s)
Dolor de la Región Lumbar , Ansiedad , Catastrofización , Miedo , Humanos , Encuestas y Cuestionarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...