1.
Sci Rep ; 12(1): 15315, 2022 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-36097151

RESUMEN

One way of early diagnosis of cancer is by detecting the biomarkers that get introduced into easily accessible body fluids. We report the development of portable and rapid electronic biosensors for quantitative detection of two secretive cancer biomarkers-Carcinoembryonic antigen (CEA) and Cytokeratin fragment 19 (CYFRA 21-1). The reduced graphene oxide (rGO)/ melamine (MEL)/antibodies/ bovine serum albumin (BSA) based devices were tested for 1 pg/mL to 800 ng/mL of CEA and CYFRA 21-1. The responses of the sensors ranged from 7.14 to 59.1% and from 6.18 to 64% for 1 pg/mL to 800 ng/mL CEA and CYFRA 21-1 respectively. A read-out circuit was assembled to develop a portable prototype which was used to assess the concentrations of the two antigens present in saliva samples of 14 subjects. The prototype could accurately discriminate between 9 oral squamous cell carcinoma patients and 5 healthy controls.


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias Pulmonares , Neoplasias de la Boca , Antígenos de Neoplasias , Antígeno Carcinoembrionario , Carcinoma de Células Escamosas/patología , Electrónica , Humanos , Queratina-19 , Neoplasias Pulmonares/diagnóstico , Neoplasias de la Boca/diagnóstico , Saliva
2.
Sci Rep ; 12(1): 3006, 2022 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-35194116

RESUMEN

Point-of-care devices are expected to play very critical roles in early diagnosis and better treatment of cancer. Here, we report the end-to-end development of novel and portable biosensors for detecting carcinoembryonic antigen (CEA), a cancer biomarker, almost instantly at room temperature. The device uses reduced graphene oxide (rGO) as the base conducting layer and a novel poly[(1,4-phenylene)-alt-(3,6-(1,2,4,5-tetrazine)/3,6-(1,2,4,5-dihydrotetrazine))] (PhPTz) as an immobilizing matrix for the CEA antibodies. Judiciously introduced nitrogen-rich semiconducting PhPTz brings multiple advantages to the device-(1) efficiently immobilizes anti-CEA via synergistic H-bonding with peptide and N-glycal units and (2) transports the charge density variations, originated upon antibody-antigen interactions, to the rGO layer. The CEA was dropped onto the anti-CEA/PhPTz/rGO devices at ambient conditions, to facilitate binding and the change in current flowing through the sensors was measured. A response of 2.75-33.7 µA was observed when the devices were tested for a broad range of concentrations (0.25 pg/mL to 800 ng/mL) of CEA. A portable read-out circuit was assembled using Arduino UNO and a voltage divider circuit, and a simple algorithm was developed for the classification of the CEA concentrations. The prediction accuracy of the interfacing electronics along with the algorithm was found to be 100%.


Asunto(s)
Anticuerpos Inmovilizados , Biomarcadores de Tumor/análisis , Técnicas Biosensibles/instrumentación , Antígeno Carcinoembrionario/análisis , Grafito , Inmunoensayo/instrumentación , Algoritmos , Técnicas Biosensibles/métodos , Antígeno Carcinoembrionario/inmunología , Inmunoensayo/métodos , Polímeros , Sensibilidad y Especificidad