Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Radiol ; 79(8): e994-e1002, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38789330

RESUMEN

AIM: To develop and validate a deep learning (DL) algorithm for the automated detection and classification of carotid artery plaques (CAPs) on computed tomography angiography (CTA) images. MATERIALS AND METHODS: This retrospective study enrolled 400 patients (300 in the Center Ⅰ and 100 in Ⅱ). Three radiologists co-labeled CAPs, and their revised calcification status (noncalcified, mixed, and calcified) was regarded as ground truth. Center Ⅰ patients were randomly divided into training and internal validation datasets, while Center Ⅱ patients served as the external validation dataset. Carotid artery regions were segmented using a modified 3D-UNet network, followed by CAPs detection and classification using a ResUNet-based architecture in a two-step DL system. The DL model's detection and classification performance were evaluated on the validation dataset using precision-recall curve, free-response receiver operating characteristic (fROC) curve, Cohen's kappa, and ROC curve analysis. RESULTS: The DL model had achieved 83.4% sensitivity at 3.0 false positives (FPs)/CTA scan in internal validation and 78.9% in external validation. F1-scores were 0.764 and 0.769 at the optimal threshold, and area under fROC curves were 0.756 and 0.738, respectively, indicating good overall accuracy for CAP detection. The DL model also showed good performance for the ternary classification of CAPs, with Cohen's kappa achieved 0.728 and 0.703 in both validation datasets. CONCLUSION: This study demonstrated the feasibility of using a fully automated DL-based algorithm for the detection and ternary classification of CAPs, which could be helpful for the workloads of radiologists.


Asunto(s)
Angiografía por Tomografía Computarizada , Aprendizaje Profundo , Humanos , Angiografía por Tomografía Computarizada/métodos , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Estenosis Carotídea/diagnóstico por imagen , Arterias Carótidas/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Sensibilidad y Especificidad
2.
Zhonghua Yan Ke Za Zhi ; 60(3): 272-274, 2024 Mar 11.
Artículo en Chino | MEDLINE | ID: mdl-38462376

RESUMEN

A 61-year-old male patient presented with blurred vision in the right eye for 1 day. The patient had previously undergone phacoemulsification with intraocular lens implantation (10 years ago) and intravitreal implantation of dexamethasone (due to uveitis) in the eye. There was edema in the inferior cornea, along with Descemet membrane folds. The rod-shaped dexamethasone implant was visible in the inferior anterior chamber. Without pupil dilation, the patient was asked to keep a supine position and avoid head tilting for 1 day. The implant spontaneously relocated into the vitreous cavity, resulting in a reduction of corneal edema. This suggests that the dislocation of the intravitreal implant into the anterior chamber may be caused by a local zonular abnormality, and the dislocated implant has the potential to reposition itself spontaneously.


Asunto(s)
Dexametasona , Glucocorticoides , Masculino , Humanos , Persona de Mediana Edad , Dexametasona/uso terapéutico , Reposicionamiento de Medicamentos , Cámara Anterior , Implantación de Lentes Intraoculares , Inyecciones Intravítreas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA