Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 9(1)2020 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-31940840

RESUMEN

This study aimed to determine whether the measured resting energy expenditure (REE) in overweight and obese patients living in a temperate climate is lower than the predicted REE; and to ascertain which equation should be used in patients living in a temperate climate. REE (indirect calorimetry) and body composition (DXA) were measured in 174 patients (88 men and 86 women; 20-68 years old) with overweight or obesity (BMI 27-45 kg m-2). All volunteers were residents in Gran Canaria (monthly temperatures: 18-24 °C). REE was lower than predicted by most equations in our population. Age and BMI were similar in both sexes. In the whole population, the equations of Mifflin, Henry and Rees, Livingston and Owen, had similar levels of accuracy (non-significant bias of 0.7%, 1.1%, 0.6%, and -2.2%, respectively). The best equation to predict resting energy expenditure in overweight and moderately obese men and women living in a temperate climate all year round is the Mifflin equation. In men, the equations by Henry and Rees, Livingston, and by Owen had predictive accuracies comparable to that of Mifflin. The body composition-based equation of Johnston was slightly more accurate than Mifflin's in men. In women, none of the body composition-based equations outperformed Mifflin's.

2.
Front Physiol ; 9: 1764, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30622475

RESUMEN

The main aims of this study were to determine the accuracy of the portable metabolic cart K5 by comparison with a stationary metabolic cart (Vyntus CPX), to check on the validity of Vyntus CPX using a butane combustion test, and to assess the reliability of K5 during prolonged walks in the field. For validation, measurements were consecutively performed tests with both devices at rest and during submaximal exercise (bicycling) at low (60 W) and moderate intensities (130-160 W) in 16 volunteers. For the reliability study, 14 subjects were measured two times during prolonged walks (13 km, at 5 km/h), with the K5 set in mixing chamber (Mix) mode. Vyntus measured the stoichiometric RQ of butane combustion with high accuracy (error <1.6%) and precision (CV <0.5%), at VO2 values between 0.788 and 6.395 L/min. At rest and 60 W, there was good agreement between Vyntus and K5 (breath-by-breath, B×B) in VO2, VCO2, RER, and energy expenditure, while in Mix mode the K5 overestimated VO2 by 13.4 and 5.8%, respectively. Compared to Vyntus, at moderate intensity the K5 in B×B mode underestimated VO2, VCO2, and energy expenditure by 6.6, 6.9, and 6.6%, respectively. However, at this intensity there was an excellent agreement between methods in RER and fat oxidation. In Mix mode, K5 overestimated VO2 by 5.8 and 4.8%, at 60 W and the higher intensity, respectively. The K5 had excellent reliability during the field tests. Total energy expenditure per Km was determined with a CV for repeated measurements of 4.5% (CI: 3.2-6.9%) and a concordance correlation coefficient of 0.91, similar to the variability in VO2. This high reproducibility was explained by the low variation of FEO2 measurements, which had a CV of 0.9% (CI: 0.7-1.5%) combined with a slightly greater variability of FECO2, VE, VCO2, and RER. In conclusion, the K5 is an excellent portable metabolic cart which is almost as accurate as a state-of-art stationary metabolic cart, capable of measuring precisely energy expenditure in the field, showing a reliable performance during more than 2 h of continuous work. At high intensities, the mixing-chamber mode is more accurate than the B×B mode.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...