Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
JAMA Netw Open ; 3(1): e1919896, 2020 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-31977064

RESUMEN

Importance: Approximately one-quarter of adnexal masses detected at ultrasonography are indeterminate for benignity or malignancy, posing a substantial clinical dilemma. Objective: To validate the accuracy of a 5-point Ovarian-Adnexal Reporting Data System Magnetic Resonance Imaging (O-RADS MRI) score for risk stratification of adnexal masses. Design, Setting, and Participants: This multicenter cohort study was conducted between March 1, 2013, and March 31, 2016. Among patients undergoing expectant management, 2-year follow-up data were completed by March 31, 2018. A routine pelvic MRI was performed among consecutive patients referred to characterize a sonographically indeterminate adnexal mass according to routine diagnostic practice at 15 referral centers. The MRI score was prospectively applied by 2 onsite readers and by 1 reader masked to clinical and ultrasonographic data. Data analysis was conducted between April and November 2018. Main Outcomes and Measures: The primary end point was the joint analysis of true-negative and false-negative rates according to the MRI score compared with the reference standard (ie, histology or 2-year follow-up). Results: A total of 1340 women (mean [range] age, 49 [18-96] years) were enrolled. Of 1194 evaluable women, 1130 (94.6%) had a pelvic mass on MRI with a reference standard (surgery, 768 [67.9%]; 2-year follow-up, 362 [32.1%]). A total of 203 patients (18.0%) had at least 1 malignant adnexal or nonadnexal pelvic mass. No invasive cancer was assigned a score of 2. Positive likelihood ratios were 0.01 for score 2, 0.27 for score 3, 4.42 for score 4, and 38.81 for score 5. Area under the receiver operating characteristic curve was 0.961 (95% CI, 0.948-0.971) among experienced readers, with a sensitivity of 0.93 (95% CI, 0.89-0.96; 189 of 203 patients) and a specificity of 0.91 (95% CI, 0.89-0.93; 848 of 927 patients). There was good interrater agreement among both experienced and junior readers (κ = 0.784; 95% CI, 0.743-0824). Of 580 of 1130 women (51.3%) with a mass on MRI and no specific gynecological symptoms, 362 (62.4%) underwent surgery. Of them, 244 (67.4%) had benign lesions and a score of 3 or less. The MRI score correctly reclassified the mass origin as nonadnexal with a sensitivity of 0.99 (95% CI, 0.98-0.99; 1360 of 1372 patients) and a specificity of 0.78 (95% CI, 0.71-0.85; 102 of 130 patients). Conclusions and Relevance: In this study, the O-RADS MRI score was accurate when stratifying the risk of malignancy in adnexal masses.


Asunto(s)
Reacciones Falso Negativas , Reacciones Falso Positivas , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Enfermedades del Ovario/diagnóstico , Ultrasonografía/métodos , Ultrasonografía/normas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Persona de Mediana Edad , Medición de Riesgo , Sensibilidad y Especificidad , Adulto Joven
2.
Radiology ; 262(2): 435-49, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22282182

RESUMEN

PURPOSE: To determine whether adding shear-wave (SW) elastographic features could improve accuracy of ultrasonographic (US) assessment of breast masses. MATERIALS AND METHODS: From September 2008 to September 2010, 958 women consented to repeat standard breast US supplemented by quantitative SW elastographic examination in this prospective multicenter institutional review board-approved, HIPAA-compliant protocol. B-mode Breast Imaging Reporting and Data System (BI-RADS) features and assessments were recorded. SW elastographic evaluation (mean, maximum, and minimum elasticity of stiffest portion of mass and surrounding tissue; lesion-to-fat elasticity ratio; ratio of SW elastographic-to-B-mode lesion diameter or area; SW elastographic lesion shape and homogeneity) was performed. Qualitative color SW elastographic stiffness was assessed independently. Nine hundred thirty-nine masses were analyzable; 102 BI-RADS category 2 masses were assumed to be benign; reference standard was available for 837 category 3 or higher lesions. Considering BI-RADS category 4a or higher as test positive for malignancy, effect of SW elastographic features on area under the receiver operating characteristic curve (AUC), sensitivity, and specificity after reclassifying category 3 and 4a masses was determined. RESULTS: Median participant age was 50 years; 289 of 939 (30.8%) masses were malignant (median mass size, 12 mm). B-mode BI-RADS AUC was 0.950; eight of 303 (2.6%) BI-RADS category 3 masses, 18 of 193 (9.3%) category 4a lesions, 41 of 97 (42%) category 4b lesions, 42 of 57 (74%) category 4c lesions, and 180 of 187 (96.3%) category 5 lesions were malignant. By using visual color stiffness to selectively upgrade category 3 and lack of stiffness to downgrade category 4a masses, specificity improved from 61.1% (397 of 650) to 78.5% (510 of 650) (P<.001); AUC increased to 0.962 (P=.005). Oval shape on SW elastographic images and quantitative maximum elasticity of 80 kPa (5.2 m/sec) or less improved specificity (69.4% [451 of 650] and 77.4% [503 of 650], P<.001 for both), without significant improvement in sensitivity or AUC. CONCLUSION: Adding SW elastographic features to BI-RADS feature analysis improved specificity of breast US mass assessment without loss of sensitivity.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Aumento de la Imagen/métodos , Ultrasonografía Mamaria/métodos , Adulto , Anciano , Anciano de 80 o más Años , Europa (Continente) , Femenino , Humanos , Internacionalidad , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resistencia al Corte , Estados Unidos , Adulto Joven
3.
Int J Gynaecol Obstet ; 107(1): 1-3, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19477444

RESUMEN

OBJECTIVE: To compare the imaging procedures and surgical strategies used to treat placenta accreta at referral centers in France and Argentina. METHOD: A total of 52 women suspected of having placenta accreta underwent ultrasound and placental magnetic resonance imaging evaluations at these centers between May 2003 and October 2006. Findings and management were recorded. RESULTS: The use of the 2 imaging technologies was similar in France and Argentina and conservative surgical treatment was predominant in both groups. The placenta was left in situ in 64.7% of cases at the French center whereas resection of the placenta and invaded area were performed in 91.4% of cases in Argentina. CONCLUSION: The same diagnostic tools were used in the 2 groups, but there were differences in diagnostic accuracy and in the types of surgical procedures performed.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Placenta Accreta/diagnóstico , Ultrasonografía Prenatal/métodos , Adulto , Argentina , Femenino , Francia , Humanos , Placenta Accreta/cirugía , Embarazo , Diagnóstico Prenatal/métodos , Estudios Retrospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...