Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biomed Imaging Interv J ; 4(1): e4, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21614315

RESUMEN

PURPOSE: To investigate the optimal sensitometric curves of extended dose range (EDR2) radiographic film in terms of depth, field size, dose range and processing conditions for dynamic intensity modulated radiation therapy (IMRT) dosimetry verification with 6 MV X-ray beams. MATERIALS AND METHODS: A Varian Clinac 23 EX linear accelerator with 6 MV X-ray beam was used to study the response of Kodak EDR2 film. Measurements were performed at depths of 5, 10 and 15 cm in MedTec virtual water phantom and with field sizes of 2x2, 3x3, 10x10 and 15x15 cm(2). Doses ranging from 20 to 450 cGy were used. The film was developed with the Kodak RP X-OMAT Model M6B automatic film processor. Film response was measured with the Vidar model VXR-16 scanner. Sensitometric curves were applied to the dose profiles measured with film at 5 cm in the virtual water phantom with field sizes of 2x2 and 10x10 cm(2) and compared with ion chamber data. Scanditronix/Wellhofer OmniPro(TM) IMRT software was used for the evaluation of the IMRT plan calculated by Eclipse treatment planning. RESULTS: Investigation of the reproducibility and accuracy of the film responses, which depend mainly on the film processor, was carried out by irradiating one film nine times with doses of 20 to 450 cGy. A maximum standard deviation of 4.9% was found which decreased to 1.9% for doses between 20 and 200 cGy. The sensitometric curves for various field sizes at fixed depth showed a maximum difference of 4.2% between 2x2 and 15x15 cm(2) at 5 cm depth with a dose of 450 cGy. The shallow depth tended to show a greater effect of field size responses than the deeper depths. The sensitometric curves for various depths at fixed field size showed slightly different film responses; the difference due to depth was within 1.8% for all field sizes studied. Both field size and depth effect were reduced when the doses were lower than 450 cGy. The difference was within 2.5% in the dose range from 20 to 300 cGy for all field sizes and depths studied. Dose profiles measured with EDR2 film were consistent with those measured with an ion chamber. The optimal sensitometric curve was acquired by irradiating film at a depth of 5 cm with doses ranging from 20 to 450 cGy with a 3×3 cm(2) multileaf collimator. The optimal sensitometric curve allowed accurate determination of the absolute dose distribution. In almost 200 cases of dynamic IMRT plan verification with EDR2 film, the difference between measured and calculated dose was generally less than 3% and with 3 mm distance to agreement when using gamma value verification. CONCLUSION: EDR2 film can be used for accurate verification of composite isodose distributions of dynamic IMRT when the optimal sensitometric curve has been established.

2.
J Med Assoc Thai ; 86(7): 603-11, 2003 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12948253

RESUMEN

A retrospective study was performed on 69 patients with intracranial germ cell tumors who were treated at the Division of Radiation Oncology, Department of Radiology, King Chulalongkorn Memorial Hospital from 1990 to 2000. Median age was 15 years. Forty-two cases (60.87%) had histologically confirmed germinoma or nongerminomatous germ cell tumors. Germinoma was the predominate histology followed by mixed germ cell tumors. Pineal and suprasellar regions were the two leading sites, hydrocephalus (85.5%) and diplopia (57.97%) were the two most common clinical presentations. Only 13 cases had the result of cerebrospinal fluid (CSF) cytology or magnetic resonance imagine (MRI) of the spine before initial treatment. Serum tumor markers, Alpha fetoprotein and beta-human chorionic gonadotropin, were available in 66.67 per cent. Total or partial tumor removal were feasible in 24 cases. Whole brain irradiation was given in almost all cases with the median dose of 3,600 cGy. The median total tumor dose was 5,400 cGy. Whole spine radiation was utilized in 17 cases. The mean follow-up time was 41 months. The five-year disease free survival was 73.59 per cent. Overall 3 and 5 year survival rates were 86.45 per cent and 81.64 per cent, respectively.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Germinoma/radioterapia , Adolescente , Adulto , Neoplasias Encefálicas/mortalidad , Neoplasias Encefálicas/patología , Niño , Preescolar , Supervivencia sin Enfermedad , Femenino , Germinoma/mortalidad , Germinoma/patología , Humanos , Masculino , Persona de Mediana Edad , Dosificación Radioterapéutica , Estudios Retrospectivos , Irradiación Corporal Total
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA