Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 93(6): 063503, 2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-35778011

RESUMEN

The Korea Atomic Energy Research Institute has recently proposed and developed a novel cesium-free negative hydrogen/deuterium ion source system based on two pulsed plasma sources for fusion and particle accelerator applications. The main feature of this ion source system is the use of both magnetic filters and plasma pulsing (also called the temporal filter). The system operates with two alternate pulsing sequences related to the respective plasma sources, thereby switching the plasmas in the after-glow state in an alternating manner. This study investigates the temporal behavior of deuterium negative ions in the system in a qualitative way by conducting a time-resolved measurement of laser photodetachment current commensurate with the negative ion density. In preliminary experiments, the current in the initial after-glow state remains higher than in the active-glow state identical to a steady-state continuous wave plasma, and the ratio reaches a maximum of about three times. This indicates that the pulsing gives highly efficient negative ion volume formation. Furthermore, it is observed that the time duration when the current is maintained at high values can be prolonged (or modulated) with the alternate dual pulsing, which is not possible with conventional single pulsing. These results provide a clue that the multi-pulsed ion source system may offer a continuous supply of negative ions at high densities and consequently become an alternative to cesium seeded ion sources.

2.
Rev Sci Instrum ; 85(2): 02B119, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593559

RESUMEN

In a volume-produced negative hydrogen ion source, control of electron temperature is essential due to its close correlation with the generation of highly vibrationally excited hydrogen molecules in the heating region as well as the generation of negative hydrogen ions by dissociative attachment in the extraction region. In this study, geometric effects of the cylindrical discharge chamber on negative ion generation via electron temperature changes are investigated in two discharge chambers with different lengths of 7.5 cm and 11 cm. Measurements with a radio-frequency-compensated Langmuir probe show that the electron temperature in the heating region is significantly increased by reducing the length of the discharge chamber due to the reduced effective plasma size. A particle balance model which is modified to consider the effects of discharge chamber configuration on the plasma parameters explains the variation of the electron temperature with the chamber geometry and gas pressure quite well. Accordingly, H(-) ion density measurement with laser photo-detachment in the short chamber shows a few times increase compared to the longer one at the same heating power depending on gas pressure. However, the increase drops significantly as operating gas pressure decreases, indicating increased electron temperatures in the extraction region degrade dissociative attachment significantly especially in the low pressure regime. It is concluded that the increase of electron temperature by adjusting the discharge chamber geometry is efficient to increase H(-) ion production as long as low electron temperatures are maintained in the extraction region in volume-produced negative hydrogen ion sources.

3.
Rev Sci Instrum ; 83(10): 10D721, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126895

RESUMEN

A dual sensor probe array is designed and constructed for internal magnetic field measurement at Versatile Experiment Spherical Torus (VEST) at the Seoul National University. Simultaneous use of Hall sensors and chip inductors allows cross-calibration among the measurements and compensation for each other's weaknesses while their small sizes are expected to cause only mild plasma perturbations. Calibration of the dual sensor probe array, using a Helmholtz coil, shows good sensitivity for the magnetic field measurement of the VEST. Prior to Ohmic start-up, the magnetic field structure inside the vacuum chamber is measured by using the calibrated probe array. The dual sensor probe array is expected to be useful in analyzing the temporal magnetic field structure change during the magnetic reconnection and in reconstruction of the current profile during the discharge of the VEST device.

4.
Rev Sci Instrum ; 83(2): 02B314, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380293

RESUMEN

A high monatomic beam fraction is an important factor in a hydrogen ion source to increase the application efficiency. The monatomic fraction of hydrogen plasmas with different plasma electrode materials is measured in a helicon plasma ion source, and aluminum shows the highest value compared to that with the other metals such as copper and molybdenum. Formation of an aluminum oxide layer on the aluminum electrode is determined by XPS analysis, and the alumina layer is verified as the high monatomic fraction. Both experiments and numerical simulations conclude that a low surface recombination coefficient of the alumina layer on the plasma electrode is one of the most important parameters for increasing the monatomic fraction in hydrogen plasma ion sources.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...